Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Inverse Compton scattering”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

45 records · Page 3

Quasiclassical Computations of Compton-Scattered Spectra

Quality X-ray sources are crucial to fundamental physics research, medical radiology, humanities research, and materials science. While synchrotron radiation (SR) facilities produce the state-of-the-art emissions with respect to brilliance and frequency tunability, the great expense required to build, maintain, and operate these structures greatly limits their accessibility to researchers. Much of the research conducted at SR facilities, however, may be conducted with inverse Compton sources (ICS). Accelerator-based Compton scattering light sources generate high-energy, high-brilliance emissions. Compton scattering is the process by which a photon scatters o? an electron. ICS offer an affordable, in-lab alternative to SR facilities. Even though SR facilities produce greater intensity emissions, Compton sources provide the same frequency tunability at the intensities suitable for the purposes of many researchers currently fighting for time at SR facilities, i.e., ICS provides intensities suitable for contrast imaging, X-ray fluorescence, X-ray-diffraction, and X-ray spectroscopy. The focus of this work is to create computational models to simulate Compton-scattered spectra. These models have been used to build a theoretical basis for methods of improving the quality of future Compton sources and to preform diagnostic analysis of existing light sources. The theoretical basis of each model is derived from first principles. The numerical methods employed by each model are defined. A full description of the various functionalities of each code will be addressed. Furthermore, an in-depth analysis of spectral bandwidth sources is discussed. The complex physics arising from an extremely high-intensity, nonlinear laser pulse is explored in detail. Methods of frequency modulation of the incident laser, i.e., a method for correcting the nonlinear broadening effects on the scattered spectrum, will also be discussed. The work will conclude with a an exploration of the ongoing research efforts regarding regimes of operation outside of the limits of these current models.

Johnson, Erik↗

Bayesian Neural Network Variational Autoencoder Inverse Mapper (BNN-VAIM) and its application in Compton Form Factors extraction

Abstract We extend the Variational Autoencoder Inverse Mapper (VAIM) framework for the inverse problem of extracting Compton Form Factors (CFFs) from deeply virtual exclusive reactions, such as the unpolarized Deeply virtual exclusive scattering (DVCS) cross section. VAIM is an end-to-end deep learning framework to address the solution ambiguity issue in ill-posed inverse problems, which comprises of a forward mapper and a backward mapper to simulate the forward and inverse processes, respectively. In particular, we incorporate Bayesian Neural Network (BNN) into the VAIM architecture (BNN-VAIM) for uncertainty quantification. By sampling the weights and biases distributions of the BNN in the backward mapper of the VAIM, BNN-VAIM is able to estimate prediction uncertainty associated with each individual solution obtained for an ill-posed inverse problem. We first demonstrate the uncertainty quantification capability of BNN-VAIM in a toy inverse problem. Then, we apply BNN-VAIM to the inverse problem of extracting 8 CFFs from the unpolarized DVCS cross section.

Instruments & Instrumentation↗

A Search for Pulsars around Sgr A* in the First Event Horizon Telescope Data Set

In 2017 the Event Horizon Telescope (EHT) observed the supermassive black hole at the center of the Milky Way, Sagittarius A* (Sgr A*), at a frequency of 228.1 GHz (λ = 1.3 mm). The fundamental physics tests that even a single pulsar orbiting Sgr A* would enable motivate searching for pulsars in EHT data sets. The high observing frequency means that pulsars—which typically exhibit steep emission spectra—are expected to be very faint. However, it also negates pulse scattering, an effect that could hinder pulsar detections in the Galactic center. Additionally, magnetars or a secondary inverse Compton emission could be stronger at millimeter wavelengths than at lower frequencies. We present a search for pulsars close to Sgr A* using the data from the three most sensitive stations in the EHT 2017 campaign: the Atacama Large Millimeter/submillimeter Array, the Large Millimeter Telescope, and the IRAM 30 m Telescope. We apply three detection methods based on Fourier-domain analysis, the fast folding algorithm, and single-pulse searches targeting both pulsars and burst-like transient emission. We use the simultaneity of the observations to confirm potential candidates. No new pulsars or significant bursts were found. Being the first pulsar search ever carried out at such high radio frequencies, we detail our analysis methods and give a detailed estimation of the sensitivity of the search. We conclude that the EHT 2017 observations are only sensitive to a small fraction (≲2.2%) of the pulsars that may exist close to Sgr A*, motivating further searches for fainter pulsars in the region.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Statistical modelling and Bayesian inversion for a Compton imaging system: application to radioactive source localization

Abstract This paper presents a statistical forward model for a Compton imaging system, called Compton imager. This system, under development at the University of Illinois Urbana Champaign, is a variant of Compton cameras with a single type of sensors which can simultaneously act as scatterers and absorbers. This imager is convenient for imaging situations requiring a wide field of view. The proposed statistical forward model is then used to solve the inverse problem of estimating the location and energy of point-like sources from observed data. This inverse problem is formulated and solved in a Bayesian framework by using a Metropolis within Gibbs algorithm for the estimation of the location, and an expectation-maximization algorithm for the estimation of the energy. This approach leads to more accurate estimation when compared with the deterministic standard back-projection approach, with the additional benefit of uncertainty quantification in the low photon imaging setting.

Tarpau, Cécilia (ORCID:0000000286539490)↗

The contribution of Compton ionization to ultrafast x-ray scattering

We investigate the role of Compton ionization in ultrafast non-resonant x-ray scattering using a molecular model system, which includes the ionization continuum via an orthonormalized plane wave ansatz. Elastic and inelastic components of the scattering signal, as well as coherent-mixed scattering that arises from electron dynamics, are calculated. By virtue of a near-quantitative distinction between scattering related to electronic transitions into bound and continuum states, we demonstrate how Compton ionization contributes to the coherent-mixed component. Analogous to inelastic scattering, the contribution to the coherent-mixed signal is significant and particularly manifests at intermediate and high-momentum transfers. Strikingly, for molecules with inversion symmetry, the exclusion of bound or continuum transitions may lead to the prediction of spurious coherent-mixed signals. We conclude that qualitative and quantitative accuracies of predicted scattering signals on detectors without energy resolution require that elements of the two-electron density operator are used. This approach inherently accounts for all accessible electronic transitions, including ionization.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Shedding light on shadow generalized parton distributions

The feasibility of extracting generalized parton distributions (GPDs) from deeply virtual Compton scattering (DVCS) data has recently been questioned because of the existence of an infinite set of so-called “shadow GPDs” (SGPDs). These SGPDs depend on the process and manifest as multiple solutions (at a fixed scale 𝑄 2 ) to the inverse problem that needs to be solved to infer GPDs from DVCS data. SGPDs therefore pose a significant challenge for extracting GPDs from DVCS data. With this motivation we study the extent to which QCD evolution can provide constraints on SGPDs. This is possible because the known classes of SGPDs begin to contribute to observables after evolution, and can then be constrained (at the input scale 𝑄$^{2}_{0}$) by data that has a finite 𝑄 2 range. The impact that SGPDs could have on determining the total angular momentum, pressure and sheer force distributions, and tomography is also discussed. We find that 𝑄 2 evolution, given empirical data over a wide range of skewness (𝜉 ) and 𝑄 2 scales, constrains the SGPDs studied at low 𝑥 and low 𝜉. If this finding generalizes to all SGPDs—and we have not been able to find any SGPDs with qualitatively different behavior—then this potentially makes extraction of GPDs from DVCS possible over a limited range of 𝑥 and 𝜉.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Quantification of LEU Holdup using gamma ray imaging and inverse transport solver

Holdup is the residual amount of special nuclear material (SNM) remaining in a processing facility after the bulk materials have been cleaned out. In commercial uranium processing facilities, quantification of holdup is a major challenge because of the highly variable shapes and sizes of the deposits. Any method that attempts to generalize and calibrate deposit shapes in order to quantify holdup will be prone to high uncertainties. Uncertainties on the order of ±50% are typical in holdup results. In international safeguards applications, a ±50% uncertainty can result in a large amount of material unaccounted for (MUF) thereby increasing the difficulty of detecting material diversion and facility misuse. An imaging-based methodology has been developed with the objective of significantly reducing this uncertainty by using the true deposit shape, instead of relying on oversimplified geometric assumptions. The project is a collaboration between ORNL, Y-12, and the University of Tennessee, Knoxville, TN. Uranium sources of known masses were measured using the Germanium Gamma-ray Imager (GeGI), a high-resolution imaging spectrometer, creating a pixelated map for each spectral bin. Two different gamma imaging methods are employed in this work: coded aperture imaging and Compton imaging. A validated MonteCarlo model of the detector has been developed using the GEANT4 code for determining the intrinsic response of the detector, its enclosure, and the coded aperture mask. An inverse transport solver based on the Markov Chain Monte-Carlo approach known as Differential Evolution Adaptive Metropolis (DREAM) is employed to use the measurement data from the image pixels (coded aperture or Compton) to solve for the mass of 235 U in the deposit. A reliable method based on the DREAM solver has been developed to flag the infinite thickness condition of a uranium deposit. The project team is working towards improving the image reconstruction for Compton imaging so that a better localization of the source can be achieved. Besides treating the coded aperture and Compton imaging methods independently, the project is also evaluating a combined method that uses the Compton scatter data from a coded aperture measurement. GEANT4 simulations are being performed to evaluate the combined approach. The impact on the DREAM optimization as the source thickness progressively approaches infinite thickness is being evaluated. A number of uranium sources available at ORNL have been measured, and the DREAM results have been tested and validated for the coded aperture imaging. A similar effort will be carried out to validate the Compton based method once the development of algorithms for better localization are complete. The imaging based quantification is very amenable to unattended monitoring of holdup accumulation at key measurement points. A proof of concept measurement has been completed to demonstrate this capability The current work used the high energy resolution imager GeGI. However, the approach and methodologies are applicable to other imagers such as the cadmium zin telluride (CZT) based imager manufactured by H3D, Inc.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Laser Frequency Transverse Modulation Might Compensate for the Spectral Broadening Due to Large Electron Energy Spread in Thomson Sources

Compact laser plasma accelerators generate high-energy electron beams with increasing quality. When used in inverse Compton backscattering, however, the relatively large electron energy spread jeopardizes potential applications requiring small bandwidths. We present here a novel interaction scheme that allows us to compensate for the negative effects of the electron energy spread on the spectrum, by introducing a transverse spatial frequency modulation in the laser pulse. Such a laser chirp, together with a properly dispersed electron beam, can substantially reduce the broadening of the Compton bandwidth due to the electron energy spread. We show theoretical analysis and numerical simulations for hard X-ray Thomson sources based on laser plasma accelerators.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗