Fuel cell crimp-resistant cooling device with internal coil

A cooling assembly for fuel cells having a simplified construction whereby coolant is efficiently circulated through a conduit arranged in serpentine fashion in a channel within a member of such assembly. The channel is adapted to cradle a flexible, chemically inert, conformable conduit capable of manipulation into a variety of cooling patterns without crimping or otherwise restricting of coolant flow. The conduit, when assembled with the member, conforms into intimate contact with the member for good thermal conductivity. The conduit is non-corrodible and can be constructed as a single, manifold-free, continuous coolant passage means having only one inlet and one outlet. The conduit has an internal coil means which enables it to be bent in small radii without crimping.

Wittel, deceased, Charles F.↗

Design Evaluation Using Finite Element Analysis of Cooled Silicon Nitride Plates for a Turbine Blade Application

Two- and three-dimensional finite element analyses were performed on uncoated and thermal barrier coated (TBC) silicon nitride plates with and without internal cooling by air. Steady-state heat-transfer analyses were done to optimize the size and the geometry of the cooling channels to reduce thermal stresses, and to evaluate the thermal environment experienced by the plate during burner rig testing. The limited experimental data available were used to model the thermal profile exerted by the flame on the plate. Thermal stress analyses were performed to assess the stress response due to thermal loading. Contours for the temperature and the representative stresses for the plates were generated and presented for different cooling hole sizes and shapes. Analysis indicates that the TBC experienced higher stresses, and the temperature gradient was much reduced when the plate was internally cooled by air. The advantages and disadvantages of several cooling channel layouts were evaluated.

Abdul-Aziz, Ali↗

Effects of Thermal Barrier Coatings on Approaches to Turbine Blade Cooling

Reliance on Thermal Barrier Coatings (TBC) to reduce the amount of air used for turbine vane cooling is beneficial both from the standpoint of reduced NOx production, and as a means of improving cycle efficiency through improved component efficiency. It is shown that reducing vane cooling from 10 to 5 percent of mainstream air can lead to NOx reductions of nearly 25 percent while maintaining the same rotor inlet temperature. An analysis is given which shows that, when a TBC is relied upon in the vane thermal design process, significantly less coolant is required using internal cooling alone compared to film cooling. This is especially true for small turbines where internal cooling without film cooling permits the surface boundary layer to remain laminar over a significant fraction of the vane surface.

Boyle, Robert J.↗

Modeling Creep-Induced Stress Relaxation at the Leading Edge of SiC/SiC Airfoils

Anticipating the implementation of advanced SiC/SiC composites into internally cooled airfoil components within the turbine section of future aero-propulsion engines, the primary objective of this study was to develop physics-based analytical and finite-element modeling tools to predict the effects of composite creep and stress relaxation at the airfoil leading edges, which will generally experience large thermal gradients at high temperatures. A second objective was to examine how some advanced NASA-developed SiC/SiC systems coated with typical EBC materials would behave as leading edge materials in terms of long-term steady-state operating temperatures. Because of the complexities introduced by mechanical stresses inherent in internally cooled airfoils, a simple cylindrical thin-walled tube model subjected to thermal stresses only is employed for the leading edge, thereby obtaining a best-case scenario for the material behavior. In addition, the SiC/SiC composite materials are assumed to behave as isotropic materials with temperature-dependent viscoelastic creep behavior as measured in-plane on thin-walled panels. Key findings include: (1) without mechanical stresses and for typical airfoil geometries, as heat flux is increased through the leading edge, life-limiting tensile crack formation will occur first in the hoop direction on the inside wall of the leading edge; (2) thermal gradients through all current SiC/SiC systems should be kept below approx.300 F at high temperatures to avoid this cracking; (3) at temperatures near the maximum operating temperatures of advanced SiC/SiC systems, thermal stresses induced by the thermal gradients will beneficially relax with time due to creep; (4) although stress relaxation occurs, the maximum gradient should still not exceed 300oF because of residual tensile stress buildup on the airfoil outer wall during cool-down; and (5) without film cooling and mechanical stresses, the NASA-developed N26 SiC/SiC system with thru-thickness Sylramic-iBN fiber reinforcement and a typical EBC coating has the potential of offering a maximum long-term steady-state operating temperature of approx.3100 F at the surface of the EBC.

Lang, Jerry↗

Fuel Cell Thermal Management Through Conductive Cooling Plates

An analysis was performed to evaluate the concept of utilizing conductive cooling plates to remove heat from a fuel cell stack, as opposed to a conventional internal cooling loop. The potential advantages of this type of cooling system are reduced stack complexity and weight and increased reliability through the reduction of the number of internal fluid seals. The conductive cooling plates would extract heat from the stack transferring it to an external coolant loop. The analysis was performed to determine the required thickness of these plates. The analysis was based on an energy balance between the thermal energy produced within the stack and the heat removal from the cooling plates. To accomplish the energy balance, the heat flow into and along the plates to the cooling fluid was modeled. Results were generated for various numbers of cells being cooled by a single cooling plate. The results provided cooling plate thickness, mass, and operating temperature of the plates. It was determined that utilizing high-conductivity pyrolitic graphite cooling plates can provide a specific cooling capacity (W/kg) equivalent to or potentially greater than a conventional internal cooling loop system.

Colozza, Anthony J.↗

Coolant passage heat transfer with rotation. A progress report on the computational aspects

Turbine airfoils are subjected to increasingly higher heat loads which escalate the cooling requirements in order to satisfy life goals for the component materials. If turbine efficiency is to be maintained, however, cooling requirements should be as low as possible. To keep the quantity of cooling air bounded, a more efficient internal cooling scheme must be developed. One approach is to employ airfoils with multipass cooling passages that contain devices to augment internal heat transfer while limiting pressure drop. Design experience with multipass cooling passage airfoils has shown that a surplus of cooling air must be provided as a margin of safety. This increased cooling air leads to a performance penalty. Reliable methods for predicting the internal thermal and aerodynamic performance of multipass cooling passage airfoils would reduce or eliminate the need for the safety margin of surplus cooling air. The objective of the program is to develop and verify improved analytical methods that will form the basis for design technology which will result in efficient turbine components with improved durability without sacrificing performance. The objective will be met by: (1) establishing a comprehensive experimental data base that can form the basis of an empirical design system; (2) developing computational fluid dynamic techniques; and (3) analyzing the information in the data base with both phenomenological modeling and mathematical modeling to derive a suitable design and analysis procedure.

Aceto, L. D.↗

Data and results from a study of internal convective cooling systems for hypersonic aircraft

An extensive survey of current and future airframe construction materials and coolants was conducted, so that the most promising candidates could be examined for cooled-panel, cooling-system and airframe concepts. Consideration was given to over 100 structural materials, 50 coolants, 6 classes of structural panel concepts, 4 classes of thermal panel concepts with numerous variations, and 3 overall cooled airframe design approaches, including unshielded, shielded, and dual temperature types. The concept identification and parametric comparison phase examined all major elements of the convectively cooled airframe, including the differing requirements at various locations on the aircraft. The parametric results were used for the investigation to two separate vehicles, a hypersonic transport with a length of 96 meters (314 feet) and a weight of 24,000 kg (528,600 lb) and a hypersonic research airplane, with a length of 25m (80 ft) and a weight of 20,300 kg (447,000 lb).

Anthony, F. M.↗

A summary of computational experience at GE Aircraft Engines for complex turbulent flows in gas turbines

This viewgraph presentation summarizes some CFD experience at GE Aircraft Engines for flows in the primary gaspath of a gas turbine engine and in turbine blade cooling passages. It is concluded that application of the standard k-epsilon turbulence model with wall functions is not adequate for accurate CFD simulation of aerodynamic performance and heat transfer in the primary gas path of a gas turbine engine. New models are required in the near-wall region which include more physics than wall functions. The two-layer modeling approach appears attractive because of its computational complexity. In addition, improved CFD simulation of film cooling and turbine blade internal cooling passages will require anisotropic turbulence models. New turbulence models must be practical in order to have a significant impact on the engine design process. A coordinated turbulence modeling effort between NASA centers would be beneficial to the gas turbine industry.

Zerkle, Ronald D.↗

Screen Channel Liquid Acquisition Device Outflow Tests in Liquid Hydrogen

This paper presents experimental design and test results of the recently concluded 1-g inverted vertical outflow testing of two 325x2300 full scale liquid acquisition device (LAD) channels in liquid hydrogen (LH2). One of the channels had a perforated plate and internal cooling from a thermodynamic vent system (TVS) to enhance performance. The LADs were mounted in a tank to simulate 1-g outflow over a wide range of LH2 temperatures (20.3 - 24.2 K), pressures (100 - 350 kPa), and flow rates (0.010 - 0.055 kg/s). Results indicate that the breakdown point is dominated by liquid temperature, with a second order dependence on mass flow rate through the LAD. The best performance is always achieved in the coldest liquid states for both channels, consistent with bubble point theory. Higher flow rates cause the standard channel to break down relatively earlier than the TVS cooled channel. Both the internal TVS heat exchanger and subcooling the liquid in the propellant tank are shown to significantly improve LAD performance.

Liquid Acquisition Device↗

Adjustable Pitot Probe

Probe readily positionable in core of uniform flow in hypersonic wind tunnel. Formed of pair of mating cylindrical housings: transducer housing and pitot-tube housing. Pitot tube supported by adjustable wedge fairing attached to top of pitot-tube housing with semicircular foot. Probe adjusted both radially and circumferentially. In addition, pressure-sensing transducer cooled internally by water or other cooling fluid passing through annulus of cooling system.

Ashby, George C., Jr.↗

Turntable mechanism

In vacuum plasma spraying a turntable must be provided which not only makes it possible to rotate and tilt a heavy workpiece, but to operate at vacuum plasma temperatures to do so. In the vacuum plasma coating of large parts such as combustion chambers of rocket engines, the workpiece must not only be rotated, but it must be tilted. Hence, the turntable must be capable not only of supporting heavy parts, but of angulating such heavy workpieces. And this must be done without drive means failure due to extremely high temperatures under which the turntable mechanism is operated. A turntable mechanism is provided which is capable of operating under such conditions. For cooling the turntable drive mechanism, internal cooling means are included.

Myers, William Neill↗

Status of the US Space Station ECLSS and internal TCS

The U.S. Space Station includes many elements and systems. Responsibility for these have been delegated to four NASA centers via a work packaging concept. Marshall Space Flight Center (MSFC) is responsible for work package one (WPOI) which includes the habitation, laboratory modules, the logistic carrier elements, as well as the environmental control and life support system (ECLSS), the internal thermal control system (ITCS), and the internal audio and video systems. Current status of the ECLSS and internal thermal are the subjects of this paper. The ECLSS is composed of six subsystem groups: the temperature humidity control, the atmosphere control and supply, the air revitalization, water reclamation and management, fecal waste management, and the fire detection and suppression subsystems. The internal TCS consists of all WP01 elements of passive and active thermal measures. The ECLSS and ITCS provide services for the permanently orbiting pressurized modules as well as the pressurized and unpressurized logistics carriers. The logistics carriers are used as ground-to-station ferries for both resupply and initial delivery of selected new equipment and later replacement items. Equipment, which cannot be subjected to the rigors of the space environment, will be carried in the pressurized logistic carrier; while an unpressurized carrier is used to resupply other commodities, such as external fluid consumables. The laboratory module houses the equipment for both payloads and subsystem maintenance and repair. The habitation module is dedicated to providing living and sleeping quarters including a galley, sleeping provisions, hygiene facilities, medical services as well as services for exercise and relaxation. The four nodes that join the two modules at their ends also house electronics as well as work stations and outside viewing cupolas. The airlocks, one providing an emergency hyperbaric chamber capability, are also attached. This assembly constitutes the U.S. provided portion of the initial station. Additional international modules and docking provisions for future attached pressurized payload as well as dual logistic module and growth capabilities are also provided. The primary heat rejection mechanism is achieved via a central set of radiators provided by another work package. The interface with the central TCS at the module heat exchangers defines the active control interface boundary of the ITCS with the central TCS. All internal cooling of the permanent orbital elements are provided via internal active fluid loops within the elements utilizing water as the transport media. Cabin and equipment cooling are provided by forced air flow and cold plate heat sinks. A special active cooling loop is provided in the laboratory module to accommodate experiments and other payloads. Coatings and insulation are used in conjunction with the active components to passively limit heat losses/gains. The most challenging ECLSS new technology issues relate to oxygen and water recovery. Closure of the oxygen loop requires the use of new regenerative CO 2 removal and concentration techniques, CO 2 reduction to convert the CO 2 to water with a waste by-product, and the electrolysis of water to produce breathing oxygen for water recovery. For water recovery three separate loops are currently planned. One loop provides potable water by utilizing a combination of recovered condensate and CO 2 reduction water. A second loop purifies hygiene water from waste from the showers, clothes washer, hygiene/hand wash stations and a dishwasher. The third loop provides hygiene water by the reclamation and purification of urine water. This paper outlines the basic services provided by the ECLSS and ITCS and describes the ECLSS functional distribution throughout the pressurized assembly.

R. Humphries↗

Heat transfer in cooled guide vanes

A numerical study to determine the temperature distribution in the guide vanes of a radial inflow turbine is presented. A computer program has been developed to calculate the temperature distribution when the vanes are cooled internally using a combination of impingement and film cooling techniques. The study is based on the use of the finite difference method in a two dimensional heat conduction problem. The results are then compared to determine the best cooling configuration for a certain coolant to primary mass flow ratio.

Tabakoff, W.↗

An investigation of temperature distribution in cooled guide vanes

A numerical study to determine the temperature distribution in the guide vane blades of a radial inflow turbine is presented. A computer program was developed which permits the temperature distribution to be calculated when the blade is cooled internally using a combination of impingement and film cooling techniques. The study is based on the use of the finite difference method in a two dimensional heat conduction problem. The results are then compared to determine the best cooling configuration for a certain coolant to primary mass flow ratio.