Bear Creek High School, Jefferson County, CO
One year of continuous monitoring for Indoor Environmental Quality (IEQ) and energy use on a high school campus
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
One year of continuous monitoring for Indoor Environmental Quality (IEQ) and energy use on a high school campus
In this report, PNNL presents a review of literature and current best practices along the intersection of energy efficiency and occupant health at U.S. healthcare facilities, including federally owned buildings. This report includes a review of building standards and certification systems for healthcare indoor environmental quality (IEQ) and research on building measures that optimize occupant health and energy efficiency. The healthcare industry includes a wide variety of services and thus facility types. This case study focuses primarily on inpatient facilities, such as hospitals.
This report presents a review of literature and current best practices along the intersection of energy efficiency and occupant health at U.S. healthcare facilities, including federally owned buildings. It also includes a review of minimum code requirements for healthcare indoor environmental quality (IEQ) and research on building measures that optimize occupant health and energy efficiency.
This project identified pathways to reduce energy consumption and enhance indoor environmental quality and resilience of a 1,500-square-foot former federal armory building owned by the tribe as it is renovated as a community multipurpose facility. The scope included thermal evaluation of multiple building efficiency measures, and a techno-economic exploration of an on-site renewable energy and integrated energy storage systems.
Fact sheet describes Pacific Northwest National Laboratory’s pilot of its framework for evaluating indoor environmental quality metrics and quantifying the potential financial costs and gains related to improving occupant productivity in federal buildings. The framework was piloted at PNNL’s Richland, Washington, campus to investigate how integrated energy and health analysis could benefit building retrofit and operation strategies.
This paper addresses the framing constraints for building and community energy projects that must be considered when energy master planning (EMP) is conducted. The constraints cover emissions, sustainability, resilience, regulations and directives, and regional and local limitations such as available energy types, local conditions, and project requirements. The paper reflects development results from participants in an International Energy Agency project on energy master planning and in a U.S. Department of Defense project on technology integration to achieve resilient, low-energy use military installations. It identifies a comprehensive list of framing constraints categorized into locational threats, locational resources, energy and water distribution and storage systems, building and facility, indoor environmental, and equipment in buildings and district systems constraints. In addition, it identifies limits for these constraints that exist in seven participating countries. Some framing constraints can profoundly impact technology selection while others impact the installation of technologies (as in hardening) and have little to no impact on technology selection. Furthermore, framing constraints can be assessed in different ways and there are resources available to help EMP stakeholders evaluate them. Finally, a case is made that identifying and applying framing constraints early in EMP can bring efficiencies and better focus to the EMP process. We come to the conclusion that (1) for holistic energy planning, it is essential to identify and assess the framing constraints that bound an optimized EMP solution, (2) framing constraints limits should be evaluated as either hard or soft or promising technologies may fall out of an EMP analysis, (3) to maintain consistent quality in the EMP process, the identification of framing constraints and their limits, and perhaps their evaluation, should be standardized, (4) a standardized approach could establish a baseline that can be used, built upon, and improved, (5) as automated EMP tools are improved or developed, the resources in this paper could possibly contribute to their interworkings relative to technology screening, and (6) continued climate change and resulting aggressive goal setting will likely drive a continued and strong emphasis on EMP.
This fact sheet describes a case study of a federal office building in Fort Worth, Texas, that was used as a test site for indoor environmental quality data collection and analysis.
Providing strong economic and performance value is a primary challenge of convincing homeowners to implement deep energy retrofits to their wall systems. This study combines energy modeling and technoeconomic assessment of six experimental residential retrofit wall systems to typical existing homes in cold climates to evaluate their energy performance and cost effectiveness. Deep energy retrofits can significantly improve the energy performance of a home’s thermal envelope, help manage indoor environmental pollutants, increase homeowner comfort, increase building value, and register significant energy and cost savings in the process. We are evaluating exterior wall retrofit components and construction practices to measure and recommend steps to improve financial performance for manufacturers, installers and consumers. This study leverages a literature review, inputs from an advisory group made up of thermal enclosure experts, and simulations to identify state-of-the-art technologies for energy efficient wall systems that are suitable for cold and very cold climate zones. This paper will present results from energy modeling of six experimental wall systems compared to one baseline, that inform cost and energy performance of the subject wall systems.
The removal of water vapor from the air to reduce relative humidity is a well-known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. Also, the findings from the literature focused mainly on small flow rates on the order of one to two cfm. Electrically-enhanced condensation consists of the use of highly charged particles, preferably highly charged water droplets, that attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. An effect of the electric charge is the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation. Consequently, the equilibrium between evaporation and condensation is shifted towards condensation. Following the application of the modified Kelvin-Thomson theory, we developed a preliminary physics-based model to predict an effective size range of the charged droplets for optimal dehumidification. The range resulted in about 2 to 4 μm in diameter, under few simplifying assumptions. The effect of the size and the charge of the electrosprayed droplets on the overall dehumidification rate was briefly discussed. The use of electrosprays to produce small but highly charged droplets was broadly discussed in this paper. The cone-jet mode was identified as the most suitable electrospray operational mode, and it generated droplets of small size and high electrical charge. The cone-jet stability was also analyzed in detail. The preliminary data of the present work and the model results indicated that several electrospray heads were required to achieve a 5% dehumidification rate for airflow rates of about 5 cfm.
There is a demonstrated need for affordable housing and smaller homes. Reduced square footage new construction projects present a solution for this growing need. Completion of these types of projects is not without challenges however, as high efficiency building measures present problems with proper equipment sizing and indoor environmental quality. This case study describes the support provided by FSEC to the Manatee County Habitat for Humanity to create a small footprint home design that qualifies for Zero Energy Ready Home (ZERH) certification in Florida. Specific measures to address equipment sizing challenges, and interior air quality targets are identified among other construction elements that contribute to qualifying for ZERH certification. Discussion of the approach to meeting these challenges is informative to other efforts to build to above code standards in hot humid climates, and other regions.
The removal of water vapor from the air to reduce relative humidity is a well-known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. Also, the findings from the literature focused mainly on small flow rates on the order of one to two cfm. Electrically-enhanced condensation consists of the use of highly charged particles, preferably highly charged water droplets, that attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. An effect of the electric charge is the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation. Consequently, the equilibrium between evaporation and condensation is shifted towards condensation. Following the application of the modified Kelvin-Thomson theory, we developed a preliminary physics-based model to predict an effective size range of the charged droplets for optimal dehumidification. The range resulted in about 2 to 4 m in diameter, under few simplifying assumptions. The effect of the size and the charge of the electrosprayed droplets on the overall dehumidification rate was briefly discussed. The use of electrosprays to produce small but highly charged droplets was broadly discussed in this paper. The cone-jet mode was identified as the most suitable electrospray operational mode, and it generated droplets of small size and high electrical charge. The cone-jet stability was also analyzed in detail. The preliminary data of the present work and the model results indicated that several electrospray heads were required to achieve a 5% dehumidification rate for airflow rates of about 5 cfm.
The removal of water vapor from the air to reduce relative humidity is a well known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation with the goal to reduce the energy consumption associated with dehumidification. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. In this thesis, a broad theoretical investigation to study the electrostatically enhanced condensation processes was carried out. These processes consist of the use of highly charged particles, preferably highly charged water droplets to attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. The electrical charge promotes the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation on curved surfaces and, consequently, the equilibrium between evaporation and condensation is shifted towards condensation. This investigation resulted in the development of a thermodynamics model, which was able to predict an effective size range of the charged droplets for optimal dehumidification, under ideal conditions. The range resulted in about 2 to 4 m in diameter, while the electrical charge was kept to the maximum limit predicted by the Rayleigh model. A sensitivity analysis on the variation of the size and the charge of the charged droplets was also performed. In terms of dehumidification rates, when six electrospray heads, i.e. the maximum number of heads tested in the experimental campaign, were considered, the model predicted very limited rates, way lower than the target of this research, i.e. a dehumidification rate in terms of relative humidity of 5 % with an air flow rate of 5 cfm. While ways to increase this rate existed, their implementation proved difficult for this initial investigation. According to the requirements predicted by the model, the use of electrosprays appeared the most suitable solution for the production of small but highly charged droplets. The electrospray features and operational modes were studied in detail and an electrospray assembly was designed to be tested in this initial experimental investigation. For this initial investigation, an experimental system was designed and built to validate the thermodynamics model and with the goal to achieve a dehumidification rate of 5 % in terms of relative humidity with an air flow rate of 5 cfm. The experimental system consisted of a wind tunnel test apparatus, dew point sensors, thermocouples for temperature measurements, pressure sensors and other devices. The experimental system was equipped with a computerized data acquisition and storage system. The system was suitable to evaluate the air water content differential before and after the test section where the electrospray heads were installed. The air water content differential was evaluated in terms of the ∆ω/ω_1 ratio, to eliminate the dependence on the dry bulb temperature along the test apparatus. This work presented initial experimental data for electrostatically enhanced dehumidification processes. Working parameters, such as air and water flow rates, high voltage potentials and polarity, deionized water types with different electrical conductivity, were varied to find the best combination for an improved dehumidification. With the set up used and the conditions considered, it was never possible to achieve a 5 % dehumidification rate with 5 cfm. In general, the dehumidification rate was always limited and lower than 1 % for all the air flow rates considered and mainly within the uncertainty of the dew point sensors. These results confirmed the already limited predictions of the thermodynamics model, for ideal conditions and the interesting and promising results obtained in some experimental investigations available in the open literature were not achievable in this thesis. The more probable reasons were the higher air flow rates considered and the complete absence of the use of cooling power, which was mainly implemented to facilitate the vapor condensation.
Human-building interactions significantly influence building energy consumption and affect peak energy demand. For example, heating and cooling contribute 46% of daily peak residential energy demand. Grid-interactive efficient buildings (GEBs) can potentially increase energy-demand flexibility and accelerate the adoption of renewables. However, traditional demand response (DR) programs focused on shedding peak loads disregard the human-building interactions leading to occupant thermal frustration. Specifically, they do not model occupants’ ability to override thermostat controls, nor how indoor environmental conditions and sociocultural factors affect the timing and magnitude of overrides. Studies have found 20% of occupants override thermostat setpoints during DR events longer than 6 hours yet lack detail about the motivation that might guide more successful efforts. Balancing energy-demand flexibility with occupant thermal comfort requires understanding dynamic occupant behavior, the underlying psychophysiological drivers, in the context of homes. This paper presents methods for scalable longitudinal studies of residential occupant behavior dynamics to inform the development of psychophysiological occupant-centric building models. Smart sensors were installed to measure local environmental conditions in 20 homes in two regions of the United States. Just-in-time ecological momentary assessments (EMAs) provided qualitative data on occupant thermal comfort and local environmental conditions not captured in Internet-of-Things (IoT) based studies or existing datasets. Participant interviews provided insight into environmental attitudes, mental models, and the role of economics in comfort and behavior, which in turn may affect thermostat interactions. Based on these data, interventions in the next phase of the study will collect data and monitor occupant behavior during simulated DR events.
Over half of Alaska homes are at risk of poor indoor air quality, which increases the risk of respiratory and other illnesses for people and animals. Heat recovery ventilators (HRVs) provide warm, fresh air to a building interior while minimizing energy use. They can be programmed to provide varying amounts of fresh air to ensure adequate ventilation for occupants and can be configured to filter air during wildfires or other events. In addition to improving the safety of indoor air and extending the life of a building, HRVs can improve surrounding outdoor air because they reduce the amount of fossil fuels needed to heat a building. Recent research by CCHRC has focused on lowering barriers to using HRVs in cold climates through laboratory evaluations and homeowner education. This poster will cover data on indoor air quality in Alaska, results of CCHRC research, and future research questions.
Indoor air cleaning systems that incorporate CO 2 sorbent materials enable HVAC load shifting and efficiency improvements. This study developed a bench-scale experimental system to evaluate the performance of a sorbent under controlled operation conditions. A thermostatic holder containing 3.15 g sorbent was connected to a manifold that delivered CO 2 -enriched air at a known temperature and relative humidity (RH). The air stream was also enriched with 0.8-2.1 ppm formaldehyde. The CO 2 concentration was monitored in real-time upstream and downstream of the sorbent, and integrated formaldehyde samples were collected at different times using DNPH-coated silica cartridges. Sorbent regeneration was carried out by circulating clean air in countercurrent. Almost 200 loading/regeneration cycles were performed in the span of 17 months, from which 104 were carried out at reference test conditions defined by loading with air at 25°C, 38% RH, and 1000 ppm CO 2 , and regenerating with air at 80°C, 3% RH and 400 ppm CO 2 . The working capacity decreased slightly from 43-44 mg CO 2 per g sorbent to 39-40 mg per g over the 17 months. The capacity increased with lower loading temperature (in the range 15-35°C) and higher regeneration temperature, between 40 and 80°C. The CO 2 capacity was not sensitive to the moisture content in the range 6-9 g/m 3 , and decreased slightly when dry air was used. Loading isothermal breakthrough curves were fitted to three simple adsorption models, verifying that pseudo-first-order kinetics appropriately describes the adsorption process. The model predicted that equilibrium capacities decreased with increasing temperature from 15 to 35°C, while adsorption rate constants slightly increased. The formaldehyde adsorption efficiency was 80%-99% in different cycles, corresponding to an average capacity of 86 ± 36 µg/g. Formaldehyde was not quantitatively released during regeneration, but its accumulation on the sorbent did not affect CO 2 adsorption.
Charcoal canisters are a common method of 222 Rn screening. The calibrations of different batches of activated charcoal used in different canister designs are typically performed in large volume controlled environmental chambers with known and controlled radon concentration, temperature, and humidity. Radon screening could be facilitated in locations without ready access to environmental chambers if canisters could be accurately calibrated and undergo quality control in less controlled environments. This study compares charcoal canister calibrations from a highly controlled radon chamber with calibrations from a basement storage area experiencing temporally varying radon. In addition, the impacts of exposure time and spectral region of interest selection on calibration accuracy are investigated by comparing calibrations calculated using three different choices. Approximately 30 mo after calibrations were completed, groups of canisters were exposed for different durations of time to investigate measurement accuracy and calibration validity over an extended time. A digital simulation of charcoal canister kinetics was also performed to establish limits on how stable radon must be in a space for equilibrium-based calibration to be performed there. Overall, the accuracy of measurements using calibrations from each space differed by less than 10% after 2 d exposure time, showing that carefully controlled conditions are not necessary for the accurate calibration of charcoal canisters. Furthermore, measurement accuracy differed by less than 2% for different spectral region selections. Accuracy improved slightly with canister exposure duration. Simulations suggest that radon instability is most tolerable near the beginning of canister calibration exposures, but this merits further experimental study.
Fine particulate matter (PM2.5) air quality index (AQI) data from outdoor stationary monitors and Hazard Mapping System (HMS) smoke density data from satellites are often used as proxies for personal chemical exposure. Silicone wristbands can quantify more individualized exposure data than stationary air monitors or smoke satellites. However, it is not understood how these proxy measurements compare to chemical data measured from wristbands. We hypothesized that predictive models for personal chemical exposure would be significantly improved by expanding beyond stationary PM2.5 AQI data or satellite HMS data to also include environmental and behavioral information. In Eugene, Oregon, participants wore daily wristbands, carried a phone that recorded locations, and answered daily questionnaires for a seven-day period in multiple seasons. We gathered publicly available daily PM2.5 AQI data and HMS data. We analyzed wristbands for 94 organic chemicals, including 53 polycyclic aromatic hydrocarbons (PAHs). Wristband chemical detections and concentrations, behavioral variables (e.g., time spent indoors), and environmental conditions (e.g., PM2.5 AQI) significantly differed between seasons. Machine learning models were fit to predict personal chemical exposure using PM2.5 AQI only, HMS only, and a multivariate feature set including PM2.5 AQI, HMS, and other environmental and behavioral information. On average, the multivariate models increased predictive accuracy by approximately 70% compared to either the AQI model or the HMS model for all chemicals modeled. This study provides evidence that PM2.5 AQI data alone or HMS data alone is insufficient to explain personal chemical exposures. Our results identify additional key predictors of personal chemical exposure.
To understand how chemical exposure can impact health, researchers need tools that capture the complexities of personal chemical exposure. In practice, fine particulate matter (PM 2.5 ) air quality index (AQI) data from outdoor stationary monitors and Hazard Mapping System (HMS) smoke density data from satellites are often used as proxies for personal chemical exposure, but do not capture total chemical exposure. Silicone wristbands can quantify more individualized exposure data than stationary air monitors or smoke satellites. However, it is not understood how these proxy measurements compare to chemical data measured from wristbands. In this study, participants wore daily wristbands, carried a phone that recorded locations, and answered daily questionnaires for a 7-day period in multiple seasons. We gathered publicly available daily PM 2.5 AQI data and HMS data. We analyzed wristbands for 94 organic chemicals, including 53 polycyclic aromatic hydrocarbons. Wristband chemical detections and concentrations, behavioral variables (e.g., time spent indoors), and environmental conditions (e.g., PM 2.5 AQI) significantly differed between seasons. Machine learning models were fit to predict personal chemical exposure using PM 2.5 AQI only, HMS only, and a multivariate feature set including PM 2.5 AQI, HMS, and other environmental and behavioral information. On average, the multivariate models increased predictive accuracy by approximately 70% compared to either the AQI model or the HMS model for all chemicals modeled. This study provides evidence that PM 2.5 AQI data alone or HMS data alone is insufficient to explain personal chemical exposures. Our results identify additional key predictors of personal chemical exposure.