Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Indoor environmental”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Scaling Up to Zero Energy Ready - and Down to 530 ft2

There is a demonstrated need for affordable housing and smaller homes. Reduced square footage new construction projects present a solution for this growing need. Completion of these types of projects is not without challenges however, as high efficiency building measures present problems with proper equipment sizing and indoor environmental quality. This case study describes the support provided by FSEC to the Manatee County Habitat for Humanity to create a small footprint home design that qualifies for Zero Energy Ready Home (ZERH) certification in Florida. Specific measures to address equipment sizing challenges, and interior air quality targets are identified among other construction elements that contribute to qualifying for ZERH certification. Discussion of the approach to meeting these challenges is informative to other efforts to build to above code standards in hot humid climates, and other regions.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Analysis of New Data of Electro-static Assisted Air Dehumidification Processes

The removal of water vapor from the air to reduce relative humidity is a well-known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. Also, the findings from the literature focused mainly on small flow rates on the order of one to two cfm. Electrically-enhanced condensation consists of the use of highly charged particles, preferably highly charged water droplets, that attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. An effect of the electric charge is the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation. Consequently, the equilibrium between evaporation and condensation is shifted towards condensation. Following the application of the modified Kelvin-Thomson theory, we developed a preliminary physics-based model to predict an effective size range of the charged droplets for optimal dehumidification. The range resulted in about 2 to 4 m in diameter, under few simplifying assumptions. The effect of the size and the charge of the electrosprayed droplets on the overall dehumidification rate was briefly discussed. The use of electrosprays to produce small but highly charged droplets was broadly discussed in this paper. The cone-jet mode was identified as the most suitable electrospray operational mode, and it generated droplets of small size and high electrical charge. The cone-jet stability was also analyzed in detail. The preliminary data of the present work and the model results indicated that several electrospray heads were required to achieve a 5% dehumidification rate for airflow rates of about 5 cfm.

Morcelli, Stefano↗

Thermodynamic Model and Initial Experimental Investigation of Air Dehumidification through Electrically Charged Vapor Capturing Electrostatic Droplets

The removal of water vapor from the air to reduce relative humidity is a well known indoor environmental comfort requirement. Common dehumidification approaches require a substantial amount of energy and usually involve the cooling of atmospheric humid air below its dew point or the use of absorbent/adsorbent materials to extract water vapor out of the air. More recently, researchers investigated the effect of electrostatic forces for enhancing water vapor condensation with the goal to reduce the energy consumption associated with dehumidification. However, the studies are limited, and there is a lack of correlations that can predict the dehumidification rate. In this thesis, a broad theoretical investigation to study the electrostatically enhanced condensation processes was carried out. These processes consist of the use of highly charged particles, preferably highly charged water droplets to attract polar water vapor molecules to their surfaces and promote condensation, a phenomenon known as dielectrophoresis. The electrical charge promotes the reduction of the vapor pressure on the droplets' surface with respect to the saturated pressure predicted by the Kelvin equation on curved surfaces and, consequently, the equilibrium between evaporation and condensation is shifted towards condensation. This investigation resulted in the development of a thermodynamics model, which was able to predict an effective size range of the charged droplets for optimal dehumidification, under ideal conditions. The range resulted in about 2 to 4 m in diameter, while the electrical charge was kept to the maximum limit predicted by the Rayleigh model. A sensitivity analysis on the variation of the size and the charge of the charged droplets was also performed. In terms of dehumidification rates, when six electrospray heads, i.e. the maximum number of heads tested in the experimental campaign, were considered, the model predicted very limited rates, way lower than the target of this research, i.e. a dehumidification rate in terms of relative humidity of 5 % with an air flow rate of 5 cfm. While ways to increase this rate existed, their implementation proved difficult for this initial investigation. According to the requirements predicted by the model, the use of electrosprays appeared the most suitable solution for the production of small but highly charged droplets. The electrospray features and operational modes were studied in detail and an electrospray assembly was designed to be tested in this initial experimental investigation. For this initial investigation, an experimental system was designed and built to validate the thermodynamics model and with the goal to achieve a dehumidification rate of 5 % in terms of relative humidity with an air flow rate of 5 cfm. The experimental system consisted of a wind tunnel test apparatus, dew point sensors, thermocouples for temperature measurements, pressure sensors and other devices. The experimental system was equipped with a computerized data acquisition and storage system. The system was suitable to evaluate the air water content differential before and after the test section where the electrospray heads were installed. The air water content differential was evaluated in terms of the ∆ω/ω_1 ratio, to eliminate the dependence on the dry bulb temperature along the test apparatus. This work presented initial experimental data for electrostatically enhanced dehumidification processes. Working parameters, such as air and water flow rates, high voltage potentials and polarity, deionized water types with different electrical conductivity, were varied to find the best combination for an improved dehumidification. With the set up used and the conditions considered, it was never possible to achieve a 5 % dehumidification rate with 5 cfm. In general, the dehumidification rate was always limited and lower than 1 % for all the air flow rates considered and mainly within the uncertainty of the dew point sensors. These results confirmed the already limited predictions of the thermodynamics model, for ideal conditions and the interesting and promising results obtained in some experimental investigations available in the open literature were not achievable in this thesis. The more probable reasons were the higher air flow rates considered and the complete absence of the use of cooling power, which was mainly implemented to facilitate the vapor condensation.

Morcelli, Stefano↗

‪A Novel Methodology for Longitudinal Studies of Home Thermal Comfort Perception and Behavior

Human-building interactions significantly influence building energy consumption and affect peak energy demand. For example, heating and cooling contribute 46% of daily peak residential energy demand. Grid-interactive efficient buildings (GEBs) can potentially increase energy-demand flexibility and accelerate the adoption of renewables. However, traditional demand response (DR) programs focused on shedding peak loads disregard the human-building interactions leading to occupant thermal frustration. Specifically, they do not model occupants’ ability to override thermostat controls, nor how indoor environmental conditions and sociocultural factors affect the timing and magnitude of overrides. Studies have found 20% of occupants override thermostat setpoints during DR events longer than 6 hours yet lack detail about the motivation that might guide more successful efforts. Balancing energy-demand flexibility with occupant thermal comfort requires understanding dynamic occupant behavior, the underlying psychophysiological drivers, in the context of homes. This paper presents methods for scalable longitudinal studies of residential occupant behavior dynamics to inform the development of psychophysiological occupant-centric building models. Smart sensors were installed to measure local environmental conditions in 20 homes in two regions of the United States. Just-in-time ecological momentary assessments (EMAs) provided qualitative data on occupant thermal comfort and local environmental conditions not captured in Internet-of-Things (IoT) based studies or existing datasets. Participant interviews provided insight into environmental attitudes, mental models, and the role of economics in comfort and behavior, which in turn may affect thermostat interactions. Based on these data, interventions in the next phase of the study will collect data and monitor occupant behavior during simulated DR events.

Kane, Michael↗

Clean Indoor Air and Lower Environmental Impacts: Heat Recovery Ventilation in Cold Climates

Over half of Alaska homes are at risk of poor indoor air quality, which increases the risk of respiratory and other illnesses for people and animals. Heat recovery ventilators (HRVs) provide warm, fresh air to a building interior while minimizing energy use. They can be programmed to provide varying amounts of fresh air to ensure adequate ventilation for occupants and can be configured to filter air during wildfires or other events. In addition to improving the safety of indoor air and extending the life of a building, HRVs can improve surrounding outdoor air because they reduce the amount of fossil fuels needed to heat a building. Recent research by CCHRC has focused on lowering barriers to using HRVs in cold climates through laboratory evaluations and homeowner education. This poster will cover data on indoor air quality in Alaska, results of CCHRC research, and future research questions.

buildings↗

Radon-222 Charcoal Canister Steady State Model Calibrations Performed in a Highly Controlled Environmental Chamber and a Natural Indoor Environment

Charcoal canisters are a common method of 222 Rn screening. The calibrations of different batches of activated charcoal used in different canister designs are typically performed in large volume controlled environmental chambers with known and controlled radon concentration, temperature, and humidity. Radon screening could be facilitated in locations without ready access to environmental chambers if canisters could be accurately calibrated and undergo quality control in less controlled environments. This study compares charcoal canister calibrations from a highly controlled radon chamber with calibrations from a basement storage area experiencing temporally varying radon. In addition, the impacts of exposure time and spectral region of interest selection on calibration accuracy are investigated by comparing calibrations calculated using three different choices. Approximately 30 mo after calibrations were completed, groups of canisters were exposed for different durations of time to investigate measurement accuracy and calibration validity over an extended time. A digital simulation of charcoal canister kinetics was also performed to establish limits on how stable radon must be in a space for equilibrium-based calibration to be performed there. Overall, the accuracy of measurements using calibrations from each space differed by less than 10% after 2 d exposure time, showing that carefully controlled conditions are not necessary for the accurate calibration of charcoal canisters. Furthermore, measurement accuracy differed by less than 2% for different spectral region selections. Accuracy improved slightly with canister exposure duration. Simulations suggest that radon instability is most tolerable near the beginning of canister calibration exposures, but this merits further experimental study.

07 ISOTOPE AND RADIATION SOURCES↗

Plants Clean Air and Water for Indoor Environments

Wolverton Environmental Services Inc., founded by longtime government environmental scientist B.C. "Bill" Wolverton, is an environmental consulting firm that gives customers access to the results of his decades of cutting-edge bioremediation research. Findings about how to use plants to improve indoor air quality have been published in dozens of NASA technical papers and in the book, "How to Grow Fresh Air: 50 Houseplants That Purify Your Home or Office." The book has now been translated into 12 languages and has been on the shelves of bookstores for nearly 10 years. A companion book, "Growing Clean Water: Nature's Solution to Water Pollution," explains how plants can clean waste water. Other discoveries include that the more air that is allowed to circulate through the roots of the plants, the more effective they are at cleaning polluted air; and that plants play a psychological role in welfare in that people recover from illness faster in the presence of plants. Wolverton Environmental is also working in partnership with Syracuse University, to engineer systems consisting of modular wicking filters tied into duct work and water supplies, essentially tying plant-based filters into heating, ventilation, and air conditioning (HVAC) systems. Also, the company has recently begun to assess the ability of the EcoPlanter to remove formaldehyde from interior environments. Wolverton Environmental is also in talks with designers of the new Stennis Visitor's Center, who are interested in using its designs for indoor air-quality filters

Source record↗

Data to Accompany: PM2.5 is insufficient to explain personal PAH exposure

Fine particulate matter (PM2.5) air quality index (AQI) data from outdoor stationary monitors and Hazard Mapping System (HMS) smoke density data from satellites are often used as proxies for personal chemical exposure. Silicone wristbands can quantify more individualized exposure data than stationary air monitors or smoke satellites. However, it is not understood how these proxy measurements compare to chemical data measured from wristbands. We hypothesized that predictive models for personal chemical exposure would be significantly improved by expanding beyond stationary PM2.5 AQI data or satellite HMS data to also include environmental and behavioral information. In Eugene, Oregon, participants wore daily wristbands, carried a phone that recorded locations, and answered daily questionnaires for a seven-day period in multiple seasons. We gathered publicly available daily PM2.5 AQI data and HMS data. We analyzed wristbands for 94 organic chemicals, including 53 polycyclic aromatic hydrocarbons (PAHs). Wristband chemical detections and concentrations, behavioral variables (e.g., time spent indoors), and environmental conditions (e.g., PM2.5 AQI) significantly differed between seasons. Machine learning models were fit to predict personal chemical exposure using PM2.5 AQI only, HMS only, and a multivariate feature set including PM2.5 AQI, HMS, and other environmental and behavioral information. On average, the multivariate models increased predictive accuracy by approximately 70% compared to either the AQI model or the HMS model for all chemicals modeled. This study provides evidence that PM2.5 AQI data alone or HMS data alone is insufficient to explain personal chemical exposures. Our results identify additional key predictors of personal chemical exposure.

Bramer, Lisa M↗

PM 2.5 Is Insufficient to Explain Personal PAH Exposure

To understand how chemical exposure can impact health, researchers need tools that capture the complexities of personal chemical exposure. In practice, fine particulate matter (PM 2.5 ) air quality index (AQI) data from outdoor stationary monitors and Hazard Mapping System (HMS) smoke density data from satellites are often used as proxies for personal chemical exposure, but do not capture total chemical exposure. Silicone wristbands can quantify more individualized exposure data than stationary air monitors or smoke satellites. However, it is not understood how these proxy measurements compare to chemical data measured from wristbands. In this study, participants wore daily wristbands, carried a phone that recorded locations, and answered daily questionnaires for a 7-day period in multiple seasons. We gathered publicly available daily PM 2.5 AQI data and HMS data. We analyzed wristbands for 94 organic chemicals, including 53 polycyclic aromatic hydrocarbons. Wristband chemical detections and concentrations, behavioral variables (e.g., time spent indoors), and environmental conditions (e.g., PM 2.5 AQI) significantly differed between seasons. Machine learning models were fit to predict personal chemical exposure using PM 2.5 AQI only, HMS only, and a multivariate feature set including PM 2.5 AQI, HMS, and other environmental and behavioral information. On average, the multivariate models increased predictive accuracy by approximately 70% compared to either the AQI model or the HMS model for all chemicals modeled. This study provides evidence that PM 2.5 AQI data alone or HMS data alone is insufficient to explain personal chemical exposures. Our results identify additional key predictors of personal chemical exposure.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Vanderbilt Alumni Hall

This dataset includes processed and raw data from the Vanderbilt Alumni Hall Building (VAH) located on the University of Vanderbilt Campus in Nashville, TN. VAH is a mixed use commercial building (LEED Gold Certified) that consists of classrooms, meeting rooms, office rooms, conference rooms, an exercise room, and others. This dataset spans one year of time-series data from 2019 and includes measurements corresponding to whole building electrical power, thermal power, zone level thermal power, set-point, indoor temperature, humidity, water and air side supply and return temperatures and flow rates as CSV files. In addition to the measurements, a metadata .json file, and a .ttl file to visualize the data as per BRICK schema are also included.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

National Renewable Energy Laboratory, South Table Mountain Campus, Golden, Colorado

The National Renewable Energy Laboratory (NREL) South Table Mountain campus, located in Golden, Colorado, has multiyear datasets from buildings with approximately 1,100,000 sq ft of floor area. These 16 buildings include a large office, nine laboratories, and other education or public assembly facilities such as an education center, a warehouse, quick service restaurants, two site entrance security buildings, and a parking garage—all constructed and improved from 1982 to 2014. These datasets are also available from the NREL data storage and management platform SkySparks. The datasets contain electricity meter data (poser, voltage, and current) with 1-minute resolution and building automation system (BAS) data with resolutions of 5 or 15 minutes. Some subsystems (e.g., lighting) or equipment electricity data have the same intervals as above. Some mechanical equipment state or condition data, such as flow and temperature, are captured with 5- to 15-minute intervals. The types of measurement points (i.e., electrical meter power and zone temperature) and associated data quality across the campus are typical, which helps reduce the unreliability of data quality.

STM, Systems and equipment operational, Energy use↗

Ecobee Donate Your Data 1,000 homes in 2017

This dataset is a subset of the Ecobee Donate Your Data (DYD) dataset. The Ecobee DYD data comprises user-reported metadata (of home and occupant characteristics), and data collected by Ecobee thermostats (reported in 5-minute intervals). Participant data are pulled from the Ecobee servers, and then anonymized to remove any personally identifiable information. This subset selects 1,000 single family homes in four states - California, Texas, New York, and Illinois, and span the entire year of 2017. In addition to the measurements, a metadata JSON file is included to illustrate the high-level contextual information of the dataset. The dataset can be analyzed to understand how a single-family heating, ventilation, and air-conditioning (HVAC) system operates, occupant behavior, and building thermal dynamics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Citywide indoor air sampling mirrors wastewater and clinical for environmental surveillance of respiratory viruses

Wastewater surveillance of respiratory pathogens can provide timely estimates of viral activity and disease trends in a population. Indoor air surveillance could be used similarly with some advantages but remains largely unvalidated at the community -scale. Here, an indoor air surveillance program was employed as part of public health environmental surveillance in Chicago, Illinois, USA. Ten air samplers were placed in healthcare and congregate living settings across the city. Weekly air samples were evaluated for influenza A, influenza B, respiratory syncytial virus, and SARS -CoV-2 over two respiratory virus seasons (2023 -2025). Citywide, aggregated air sample positivity and viral load were closely correlated with local clinical case and wastewater surveillance data across all respiratory viruses. Virus trends in air data often preceded clinical and wastewater, although this varied across pathogens and respiratory virus seasons. Further, whole -genome sequencing of SARS -CoV-2 showed close correlation of variant proportions across all datasets. At the building -scale, air samples obtained from a single sampling device provided efficient respiratory virus surveillance, with respiratory pathogen levels mirroring citywide clinical surveillance data. These data demonstrate that air surveillance can provide respiratory virus case and variant trend data at a building or community -scale, serving as an alternative or complementary tool for public health environmental surveillance.

Wilton, Rosemarie↗

A three-year dataset supporting research on building energy management and occupancy analytics

Abstract This paper presents the curation of a monitored dataset from an office building constructed in 2015 in Berkeley, California. The dataset includes whole-building and end-use energy consumption, HVAC system operating conditions, indoor and outdoor environmental parameters, as well as occupant counts. The data were collected during a period of three years from more than 300 sensors and meters on two office floors (each 2,325 m 2 ) of the building. A three-step data curation strategy is applied to transform the raw data into research-grade data: (1) cleaning the raw data to detect and adjust the outlier values and fill the data gaps; (2) creating the metadata model of the building systems and data points using the Brick schema; and (3) representing the metadata of the dataset using a semantic JSON schema. This dataset can be used in various applications—building energy benchmarking, load shape analysis, energy prediction, occupancy prediction and analytics, and HVAC controls—to improve the understanding and efficiency of building operations for reducing energy use, energy costs, and carbon emissions.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Nuclear Safety [Vol. 32, No. 4, October-December 1991]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 477 Report on the International Symposium on the Use of Probabilistic Safety Assessment for Operational Safety—PSA '91, S. Chakraborty and M. Khatib-Rahbar; 488 Good Relationships Are Pivotal in Nuclear Data Bases, A. S. Heger and B. V. Koen; 494 Technical Note: The Interagency Nuclear Safety Review Panel's Evaluation of the Ulysses Space Mission, J. A. Sholtis, Jr., D. A. Huff, L. B. Gray, N. P. Klug, and R. O. Winchester; ACCIDENT ANALYSIS: 502 The Severe Accident Analysis Program for the Savannah River Nuclear Production Reactors, M. L. Hyder; CONTROL AND INSTRUMENTATION: 511 A Framework for Selecting Suitable Control Technologies for Nuclear Power Plant Systems, R. A. Kisner; DESIGN FEATURES: 521 Containments for Gas-Cooled Power Reactors History and Status, P.W. Williams; ENVIRONMENTAL EFFECTS: 537 Indoor Radon: A Natural Risk, N. H. Harley and J.H. Harley; On the Importance of the Atmospheric Parameters in the Fission Products Distribution of a Severe Reactor Accident, M. C. Barla and A. R. Bayulken; Book Review: Health Effects of Exposure to Low Levels of Ionizing Radiation BEIR V, C. R. Richmond; WASTE AND SPENT FUEL MANAGEMENT: 555 Activities Related to Waste and Spent Fuel Management, M. D. Muhlheim and E. G. Silver OPERATING EXPERIENCES: 567 Effects of Component Aging on the Westhinghouse Control Rod Drive System, K. Sullivan and W. Gunther; 577 Reactor Shutdown Experience, Compiled by J. W. Cletcher, 580 Selected Safety-Related Events, Compiled by G. A. Murphy; 582 Operating U 8 Power Reactors, Compiled by M. D. Muhlheim and E. G. Silver, RECENT DEVELOPMENTS: 596 General Administrative Activities, Compiled by M. D. Muhlheim and E. G. Silver; 610 Reports, Standards, and Safety Guides, D. S. Queener; 614 Proposed Rule Changes as of June 30, 1991; ANNOUNCEMENTS: 520 Workshop on PC PRAISE: A Probabilistic Fracture Mechanics Personal Computer Code for Nuclear Power Plant Piping Reliability Assessment; 536 Fifth Workshop on Nuclear Power Plant Containment Integrity; 624 New OECD "International Information System on Occupational Exposure (ISOE)"; 625 Harvard School of Public Health Announces Short Courses; 625 Eighth Power Plant Dynamics, Control and Testing Symposium; 626 Second Training Course on Off-Site Emergency Planning and Response for Nuclear Accidents; 618 The Authors; 622 Reviewers of Nuclear Safety, Vol 32.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Cold Climate Field Study of the Effect of Defrost Controls on the Integrated Performance of a Ductless Air-Source Heat Pump

Residential heat pumps have advanced over the past decade to allow for operation at colder temperatures. However, the challenges of frost accumulation and defrosting the outdoor coil remain. The goal of this study was to evaluate the impact of the control algorithms that determine when a heat pump needs to defrost and when the base pan heater runs on the overall heating efficiency of the heat pump. In this study, which occurred during the 2023–2024 heating season, we measured the performance of a ductless air-source heat pump installed in Fairbanks, Alaska, USA. The heat pump was instrumented to measure the electrical input and the thermal output, as well as selected internal variables and indoor and outdoor environmental conditions. The heat pump was first operated with factory default control algorithms associated with the initiation of defrost and control of the base pan heater. These factory default algorithms focused on aggressively defrosting the outdoor coil and keeping the base pan ice-free. In the middle of the winter, these algorithms were changed to focus on reducing defrost cycles and increasing efficiency, while the heat pump continued to be operated and monitored. The results showed that significant increases in efficiency are possible by improving the defrost and base pan heater control algorithms.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Nuclear Safety [Vol. 32, No. 4, October-December 1991]

Nuclear Safety is a review journal that covers significant developments in the field of nuclear safety. Its scope includes the analysis and control of hazards associated with nuclear energy, operations involving fissionable materials, and the products of nuclear fission and their effects on the environment. Primary emphasis is on safety in reactor design, construction, and operation; however, the safety aspects of the entire fuel cycle, including fuel fabrication, spent-fuel processing, nuclear waste disposal, handling of radioisotopes, and environmental effects of these operations, are also treated. Table of Contents for this issue follows. GENERAL SAFETY CONSIDERATIONS: 477 Report on the International Symposium on the Use of Probabilistic Safety Assessment for Operational Safety—PSA '91, S. Chakraborty and M. Khatib-Rahbar; 488 Good Relationships Are Pivotal in Nuclear Data Bases, A. S. Heger and B. V. Koen; 494 Technical Note: The Interagency Nuclear Safety Review Panel's Evaluation of the Ulysses Space Mission, J. A. Sholtis, Jr., D. A. Huff, L. B. Gray, N. P. Klug, and R. O. Winchester; ACCIDENT ANALYSIS: 502 The Severe Accident Analysis Program for the Savannah River Nuclear Production Reactors, M. L. Hyder; CONTROL AND INSTRUMENTATION: 511 A Framework for Selecting Suitable Control Technologies for Nuclear Power Plant Systems, R. A. Kisner; DESIGN FEATURES: 521 Containments for Gas-Cooled Power Reactors History and Status, P.W. Williams; ENVIRONMENTAL EFFECTS: 537 Indoor Radon: A Natural Risk, N. H. Harley and J.H. Harley; On the Importance of the Atmospheric Parameters in the Fission Products Distribution of a Severe Reactor Accident, M. C. Barla and A. R. Bayulken; Book Review: Health Effects of Exposure to Low Levels of Ionizing Radiation BEIR V, C. R. Richmond; WASTE AND SPENT FUEL MANAGEMENT: 555 Activities Related to Waste and Spent Fuel Management, M. D. Muhlheim and E. G. Silver OPERATING EXPERIENCES: 567 Effects of Component Aging on the Westhinghouse Control Rod Drive System, K. Sullivan and W. Gunther; 577 Reactor Shutdown Experience, Compiled by J. W. Cletcher, 580 Selected Safety-Related Events, Compiled by G. A. Murphy; 582 Operating U 8 Power Reactors, Compiled by M. D. Muhlheim and E. G. Silver, RECENT DEVELOPMENTS: 596 General Administrative Activities, Compiled by M. D. Muhlheim and E. G. Silver; 610 Reports, Standards, and Safety Guides, D. S. Queener; 614 Proposed Rule Changes as of June 30, 1991; ANNOUNCEMENTS: 520 Workshop on PC PRAISE: A Probabilistic Fracture Mechanics Personal Computer Code for Nuclear Power Plant Piping Reliability Assessment; 536 Fifth Workshop on Nuclear Power Plant Containment Integrity; 624 New OECD "International Information System on Occupational Exposure (ISOE)"; 625 Harvard School of Public Health Announces Short Courses; 625 Eighth Power Plant Dynamics, Control and Testing Symposium; 626 Second Training Course on Off-Site Emergency Planning and Response for Nuclear Accidents; 618 The Authors; 622 Reviewers of Nuclear Safety, Vol 32.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗