Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Index of Refraction”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Refractive Index of Polyaryletherketone (PEEK) at X- and W-Band

This report details refractive index measurements of polyaryletherketone (PEEK) thermoplastic between X-band (8 to 12 GHz) and W-band (75 to 110 GHz) frequencies. Scattering-parameter data are collected using both traditional waveguide and modified free-space techniques. The complex-valued refractive index is calculated using the standard Nicolson-Ross-Weir method. Results indicate that PEEK’s refractive index is n = 1.783 – 0.001i across X-band and n = 1.792 – 0.007i across W-band. Therefore, PEEK exhibits a moderate real refractive index component and low transmission loss. Coupled with its favorable mechanical and thermal properties, this makes PEEK an ideal material to inspect using NASA’s submillimeter radiofrequency-based technology.

Polyaryletherketone↗

The whistler mode refractive index as a function of gyrofrequency

The refractive index for a constant-frequency whistler mode wave in an electron-proton plasma is considered as a function of position, through the local gyrofrequencies {Omega}{sub e,i}. The full cold plasma dispersion relation is used. The wave frequency can take any value up to the smaller of {Omega}{sub e} and the plasma frequency {omega}{sub pe}, but {omega}{sub pe} is allowed to take any fixed value, as is the wavenormal angle. It is rigorously established that the refractive index is a decreasing function of {Omega}{sub e}. One application of this is to finding locations of Landau and cyclotron resonances, to evaluate the effects of whistler mode waves on radiation belt electrons.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Refractive index of lithium fluoride at high dynamic stresses

Alkali halides are prototypical ionic solids whose refractive index is a fundamental property related to their lattice structure and ionic polarizability. In particular, lithium fluoride (LiF) has the largest band gap of any known transparent material and maintains transparency at high pressures, making it well suited for use as an optical window in dynamic compression experiments. While empirical fits to the measured density dependence of the refractive index have been provided, a model that is valid over the entire pressure range of experiments and based on a polarization-based theoretical description is lacking. We present a refractive index model for dynamically compressed LiF based on the Lorentz-Lorenz equation, where the molecular polarizability is determined using a single oscillator model with a strain polarizability parameter Λ=0.73. Here, we show that our modeling approach provides an excellent match to the LiF refractive index data for both shock and ramp compression experiments to 900 GPa (density compression greater than threefold). Additionally, updated fits are provided to determine the refractive index correction for LiF windows used in dynamic compression experiments.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Thickness-dependent dispersion parameters, energy gap and nonlinear refractive index of ZnSe thin films

Highlights: • Combined experimental and theoretical researches on ZnSe Thin Films. • The film thickness and refractive index were determined using envelope method. • The absorption coefficient and the energy gap were calculated. • Dispersion parameters were determined using Wemple-DiDomenico relation. • The third order susceptibility and nonlinear refractive index were calculated. - Abstract: Zinc selenide (ZnSe) thin films with different thicknesses were evaporated onto glass substrates using the thermal evaporation technique. X-ray diffraction analysis confirmed that both the film and powder have cubic zinc-blende structure. The fundamental optical parameters like absorption coefficient, extinction coefficient and band gap were evaluated in transparent region of transmittance and reflectance spectrum. The optical transition of the films was found to be allowed, where the energy gap increased from 2.576 to 2.702 eV with increasing film thickness. Also, the refractive index value increase with increasing film thickness. The refractive indices evaluated through envelope method were extrapolated by Cauchy dispersion relationship over the whole spectra range. Additionally, the dispersion of refractive index was determined in terms of Wemple-DiDomenico single oscillator model. Third order susceptibility and nonlinear refractive index were determined for different thickness of ZnSe thin films.

36 MATERIALS SCIENCE↗

Rapid assessment of mid-infrared refractive index anisotropy using a prism coupler: chemical vapor deposited ZnS

A state-of-the-art mid-infrared prism coupler was used to study the refractive index properties of forward-looking-infrared (FLIR) grade zinc sulfide samples prepared with unique planar grain orientations and locations with respect to the CVD growth axis. This study was motivated by prior photoluminescence and x-ray diffraction measurements that suggested refractive index may vary according to grain orientation. Measurements were conducted to provide optical dispersion and thermal index (dn/dT) data at discrete laser wavelengths between 0.633 and 10.591 {mu}m at two temperature set points (30 C and 90 C). Refractive index measurements between samples exhibited an average standard deviation comparable to the uncertainty of the prism coupler measurement (0.0004 refractive index units), suggesting that the variation in refractive index as a function of planar grain orientation and CVD deposition time is negligible, and should have no impact on subsequent optical designs. Measured dispersion data at mid-infrared wavelengths was found to agree well with prior published measurements.

36 MATERIALS SCIENCE↗

Giant Kerr nonlinearities using refractive-index enhancement

By utilizing refractive-index enhancement with vanishing absorption, a scheme is suggested that achieves giant Kerr nonlinearities between two weak laser beams. One application of this scheme is discussed and an all-optical distributed Bragg reflector is proposed that works at very low light levels.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Refractive index dispersion sensing using an array of photonic crystal resonant reflectors

Refractive index sensing plays a key role in various environmental and biological sensing applications. Here, a method is presented for measuring the absolute refractive index dispersion of liquids using an array of photonic crystal resonant reflectors of varying periods. It is shown that by covering the array with a sample liquid and measuring the resonance wavelength associated with transverse electric polarized quasi guided modes as a function of period, the refractive index dispersion of the liquid can be accurately obtained using an analytical expression. This method is compact, can perform measurements at arbitrary number of wavelengths, and requires only a minute sample volume. The ability to sense a material's dispersion profile offers an added dimension of information that may be of benefit to optofluidic lab-on-a-chip applications.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Further Studies on the Effect of SiN x Refractive Index and Emitter Sheet Resistance on Potential-Induced Degradation

We present the impacts of silicon nitride (SiNx) antireflection coating refractive index and emitter sheet resistance on potential-induced degradation of the shunting type (PID-s). Previously, it has been shown that the cell becomes more PID-s-susceptible as the refractive index decreases or the emitter sheet resistance increases. To verify the effect of refractive index on PID-s, we fabricated cells with varying SiN x refractive index (1.87, 1.94, 2.05) on typical p-type base solar cells with ~60 Ω/sq emitters. However, none of these cells showed output power degradation, regardless of the refractive index. Further investigation of the emitter showed that the PID-s was suppressed at ~60 Ω/sq due to the extremely high surface phosphorus concentration (6 x 10 21 cm -3 ), as measured by secondary ion mass spectrometry. Furthermore, PID-s was observed on cells possessing a high emitter sheet resistance (~80 Ω/sq). In conclusion, the emitter surface phosphorus concentration plays an important role in determining PID-s susceptibility.

14 SOLAR ENERGY↗

Effects of refractive index mismatch in optical CT imaging of polymer gel dosimeters

Purpose: Proposing an image reconstruction technique, algebraic reconstruction technique-refraction correction (ART-rc). The proposed method takes care of refractive index mismatches present in gel dosimeter scanner at the boundary, and also corrects for the interior ray refraction. Polymer gel dosimeters with high dose regions have higher refractive index and optical density compared to the background medium, these changes in refractive index at high dose results in interior ray bending. Methods: The inclusion of the effects of refraction is an important step in reconstruction of optical density in gel dosimeters. The proposed ray tracing algorithm models the interior multiple refraction at the inhomogeneities. Jacob’s ray tracing algorithm has been modified to calculate the pathlengths of the ray that traverses through the higher dose regions. The algorithm computes the length of the ray in each pixel along its path and is used as the weight matrix. Algebraic reconstruction technique and pixel based reconstruction algorithms are used for solving the reconstruction problem. The proposed method is tested with numerical phantoms for various noise levels. The experimental dosimetric results are also presented. Results: The results show that the proposed scheme ART-rc is able to reconstruct optical density inside the dosimeter better than the results obtained using filtered backprojection and conventional algebraic reconstruction approaches. The quantitative improvement using ART-rc is evaluated using gamma-index. The refraction errors due to regions of different refractive indices are discussed. The effects of modeling of interior refraction in the dose region are presented. Conclusions: The errors propagated due to multiple refraction effects have been modeled and the improvements in reconstruction using proposed model is presented. The refractive index of the dosimeter has a mismatch with the surrounding medium (for dry air or water scanning). The algorithm reconstructs the dose profiles by estimating refractive indices of multiple inhomogeneities having different refractive indices and optical densities embedded in the dosimeter. This is achieved by tracking the path of the ray that traverses through the dosimeter. Extensive simulation studies have been carried out and results are found to be matching that of experimental results.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Determination of average refractive index of spin coated DCG films for HOE fabrication

The refractive index of holographic emulsions is an important parameter needed for designing holographic optical elements (HOE's). Theoretical calculations of the accuracy required for the refractive index and thickness of emulsions needed to meet predetermined Bragg angle conditions are presented. A modified interferometric method is used to find average refractive index of the unexposed and the developed dichromated gelatin holographic films. Slanted transmission HOE's are designed considering the index and thickness variations, and used to verify the index measurement results. The Brewster angle method is used to measure surface index of the unexposed and the developed films. The differences between average index and surface index are discussed. Theoretical calculation of the effects of index variation on diffraction efficiency, and experimental results for index modulation variation caused by process changes are also presented.

Kim, T. J.↗

Observation of acoustic Dirac-like cone and double zero refractive index

Zero index materials where sound propagates without phase variation, holds a great potential for wavefront and dispersion engineering. Recently explored electromagnetic double zero index metamaterials consist of periodic scatterers whose refractive index is significantly larger than that of the surrounding medium. This requirement is fundamentally challenging for airborne acoustics because the sound speed (inversely proportional to the refractive index) in air is among the slowest. Here, we report the first experimental realization of an impedance matched acoustic double zero refractive index metamaterial induced by a Dirac-like cone at the Brillouin zone centre. This is achieved in a two-dimensional waveguide with periodically varying air channel that modulates the effective phase velocity of a high-order waveguide mode. Using such a zero-index medium, we demonstrated acoustic wave collimation emitted from a point source. For the first time, we experimentally confirm the existence of the Dirac-like cone at the Brillouin zone centre.

36 MATERIALS SCIENCE↗

Finite element approximation of the radiative transport equation in a medium with piece-wise constant refractive index

The radiative transport equation can be used as a light transport model in a medium with scattering particles, such as biological tissues. In the radiative transport equation, the refractive index is assumed to be constant within the medium. However, in biomedical media, changes in the refractive index can occur between different tissue types. In this work, light propagation in a medium with piece-wise constant refractive index is considered. Light propagation in each sub-domain with a constant refractive index is modeled using the radiative transport equation and the equations are coupled using boundary conditions describing Fresnel reflection and refraction phenomena on the interfaces between the sub-domains. The resulting coupled system of radiative transport equations is numerically solved using a finite element method. The approach is tested with simulations. The results show that this coupled system describes light propagation accurately through comparison with the Monte Carlo method. It is also shown that neglecting the internal changes of the refractive index can lead to erroneous boundary measurements of scattered light.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Digital and Gradient Refractive Index Planar Optics by Nanoimprinting Mesoporous Silicon

We report the realization of digital and gradient index flat-optics and planar waveguides using the ‘nanoimprinting refractive index’ (NIRI) technique applied to mesoporous silicon. This technique combines the distinct optical and mechanical metamaterial qualities of mesoporous silicon, including its widely tunable effective refractive index and ability to undergo plastic deformation with a near zero Poisson ratio. Nanoimprinting with premastered and reusable stamps containing analog or digital features enables the continuous or discontinuous patterning of refractive index with high contrast Δn ≥ 0.8 and subwavelength resolution. Using NIRI we experimentally demonstrate a wavefront shaping flat microlens array operating in the visible (405–635 nm) and mesoporous silicon and silica waveguides operating near 1310 nm. This study demonstrates the viability of patterning arbitrary refractive index distributions, n(x,y), on the surface of a chip while circumventing the challenges and limitations of top-down lithographic techniques – thus opening a low-cost and scalable approach for the realization of advanced planar optical technologies.

36 MATERIALS SCIENCE↗

High-refractive index acrylate polymers for applications in nanoimprint lithography

The development of polymeric optical materials with a higher refractive index, transparency in the visible spectrum region and easier processability is increasingly desirable for advanced optical applications such as microlenses, image sensors, and organic light-emitting diodes. Most acrylates have a low refractive index (around 1.50) which does not meet the high performance requirements of advanced optical materials. In this research, three novel acrylates were synthesized via a facile one-step approach and used to fabricate optical transparent polymers. All of the polymers reveal good optical properties including high transparency (≥90%) in the visible spectrum region and high refractive index values (1.6363) at 550 nm. Moreover, nanostructures of these acrylate polymers with various feature sizes including nanogratings and photonic crystals were successfully fabricated using nanoimprint lithography. Finally, these results indicate that these acrylates can be used in a wide range of optical and optoelectronic devices where nanopatterned films with high refractive index and transparency are required.

36 MATERIALS SCIENCE↗

Optical CT imaging of solid radiochromic dosimeters in mismatched refractive index solutions using a scanning laser and large area detector

Purpose: The practical use of the PRESAGE® solid plastic dosimeter is limited by the inconvenience of immersing it in high-viscosity oils to achieve refractive index matching for optical computed tomography (CT) scanning. The oils are slow to mix and difficult to clean from surfaces, and the dosimeter rotation can generate dynamic Schlieren inhomogeneity patterns in the reference liquid, limiting the rotational and overall scan speed. Therefore, it would be beneficial if lower-viscosity, water-based solutions with slightly unmatched refractive index could be used instead. The purpose of this work is to demonstrate the feasibility of allowing mismatched conditions when using a scanning laser system with a large acceptance angle detector. A fiducial-based ray path measurement technique is combined with an iterative CT reconstruction algorithm to reconstruct images. Methods: A water based surrounding liquid with a low viscosity was selected for imaging PRESAGE® solid dosimeters. Liquid selection was optimized to achieve as high a refractive index as possible while avoiding rotation-induced Schlieren effects. This led to a refractive index mismatch of 6% between liquid and dosimeters. Optical CT scans were performed with a fan-beam scanning-laser optical CT system with a large area detector to capture most of the refracted rays. A fiducial marker placed on the wall of a cylindrical sample occludes a given light ray twice. With knowledge of the rotation angle and the radius of the cylindrical object, the actual internal path of each ray through the dosimeter can be calculated. Scans were performed with 1024 projections of 512 data samples each, and rays were rebinned to form 512 parallel-beam projections. Reconstructions were performed on a 512 × 512 grid using 100 iterations of the SIRT iterative CT algorithm. Proof of concept was demonstrated with a uniformly attenuating solution phantom. PRESAGE® dosimeters (11 cm diameter) were irradiated with Cobalt-60 irradiator to achieve either a uniform dose or a 2-level “step-dose” pattern. Results: With 6% refractive index mismatching, a circular field of view of 85% of the diameter of a cylindrical sample can be reconstructed accurately. Reconstructed images of the test solution phantom were uniform (within 3%) inside this radius. However, the dose responses of the PRESAGE® samples were not spatially uniform, with variations of at least 5% in sensitivity. The variation appears as a “cupping” artifact with less sensitivity in the middle than at the periphery of the PRESAGE® cylinder. Polarization effects were also detected for these samples. Conclusions: The fiducial-based ray path measurement scheme, coupled with an iterative reconstruction algorithm, enabled optical CT scanning of PRESAGE® dosimeters immersed in mismatched refractive index solutions. However, improvements to PRESAGE® dose response uniformity are required.

60 APPLIED LIFE SCIENCES↗

Methods for Prediction of Refractive Index in Glasses for the Infrared

It is often useful to obtain custom glasses that meet particular requirements of refractive index and dispersion for high-end optical design and applications. In the case of infrared glasses, limited experimental data are available due to difficulties in processing of these glasses and also measuring refractive indices accurately. This paper proposes methods to estimate refractive index and dispersion as a function of composition for selected infrared-transmitting glasses. Methods for refractive index determination are reviewed and evaluated, including Gladstone-Dale, Wemple-DiDomenico single oscillator, Optical basicity, and Lorentz-Lorenz total polarizability. Various estimates for a set of PbO-Bi2O3-Ga2O3 (heavy metal oxide) and As-S (chalcogenide) glasses will be compared with measured values of index and dispersion.

36 MATERIALS SCIENCE↗