NASA NTRSDate not supplied
During testing on the E-1 Test Stand, the High Pressure (HP) Liquid Hydrogen (LH) vent line was displaced off its supports, damaging the expansion joints (EJ), piping, and pipe supports of the line. The damage to the vent line is believed to have occurred during Cell 3 testing on Thursday, September 21, during the first test of the day. The fuel systems being used for Cell 3 testing are connected to the LP and HP LH Vent systems and are being used in Liquid Natural Gas (LNG) service. The Cell 3 interface bleed valve that discharges to the HP LH Vent system was inadvertently left at 100% open during the chill-in process for longer than the typical amount of time. Since this valve is usually at a lower set point or intermittently closed during the chill-in process, more than the typical amount of LNG flowed into the vent line as pre-test procedures continued as normal. The open bleed valve was noticed before test preparations were completed and prior to refilling of the HP LH Tank before test. The test sequence was started, run, and shutdown normally. Video of the flare stack showed an atypical discharge of liquid at the flare stack exit. Pressure downstream of the Cell 3 interface bleed valve (a valve connected to the southernmost part of the vent system) spiked to a higher-than-normal level. No evidence of damage was captured at the time of the event. The system was used in a typical fashion after the event and for 4 subsequent tests on Thursday and Friday, before the damage was observed. A drive-by inspection of the flare stack was performed on Friday (September 22nd) morning before sunrise and before test activities began, but no damage of the vent line was observed at that time. No abnormal system behavior was observed during testing on Friday. The damage was discovered and reported to NASA Test Operations on Monday, initiating the Incident Response Team. The Mishap appointment letter was issued September 27th to formally initiate the Mishap Investigation.