Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Image Plate”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Analytical Bistatic k Space Images Compared to Experimental Swept Frequency EAR Images

A case study of flat plate scattering images obtained by the analytical bistatic k space and experimental swept frequency ISAR methods is presented. The key advantage of the bistatic k space image is that a single excitation is required, i.e., one frequency I one angle. This means that prediction approaches such as MOM only need to compute one solution at a single frequency. Bistatic image Fourier transform data are obtained by computing the scattered field at various bistatic positions about the body in k space. Experimental image Fourier transform data are obtained from the measured response to a bandwidth of frequencies over a target rotation range.

Shaeffer, John↗

Imaging flaws in thin metal plates using a magneto-optic device

An account is given of the capabilities of the magnetooptic/eddy-current imager (MEI) apparatus in the case of aging aircraft structure-type flaws in 2024-T3 Al alloy plates. Attention is given to images of cyclically grown fatigue cracks from rivetted joints in fabricated lap-joint structures, electrical discharge machining notches, and corrosion spots. Although conventional eddy-current methods could have been used, the speed and ease of MEI's use in these tests is unmatched by such means. Results are displayed in real time as a test piece is scanned, furnishing easily interpreted flaw images.

Wincheski, B.↗

Method of obtaining intensified image from developed photographic films and plates

A method is explained of obtaining intensified images from silver images on developed photographic films and plates. The steps involve converting silver of the developed film or plate to a radioactive compound by treatment with an aqueous alkaline solution of an organo-S35 compound; placing the treated film or plate in direct contact with a receiver film which is then exposed by radiation from the activated film; and developing and fixing the resulting intensified image on the receiver film.

Askins, B. S.↗

Meteor44 Video Meteor Photometry

Meteor44 is a software system developed at MSFC for the calibration and analysis of video meteor data. The dynamic range of the (8bit) video data is extended by approximately 4 magnitudes for both meteors and stellar images using saturation compensation. Camera and lens specific saturation compensation coefficients are derived from artificial variable star laboratory measurements. Saturation compensation significantly increases the number of meteors with measured intensity and improves the estimation of meteoroid mass distribution. Astrometry is automated to determine each image's plate coefficient using appropriate star catalogs. The images are simultaneously intensity calibrated from the contained stars to determine the photon sensitivity and the saturation level referenced above the atmosphere. The camera s spectral response is used to compensate for stellar color index and typical meteor spectra in order to report meteor light curves in traditional visual magnitude units. Recent efforts include improved camera calibration procedures, long focal length 'streak' meteor photometry and two-station track determination. Meteor44 has been used to analyze data from the 2001, 2002 and 2003 MSFC Leonid observational campaigns as well as several lesser showers. The software is interactive and can be demonstrated using data from recent Leonid campaigns.

Swift, Wesley R.↗

Meteor44 Video Meteor Photometry

Meteor44 is a software system developed at MSFC for the calibration and analysis of video meteor data. The dynamic range of the (8bit) video data is extended by approximately 4 magnitudes for both meteors and stellar images using saturation compensation. Camera and lens specific saturation compensation coefficients are derived from artificial variable star laboratory measurements. Saturation compensation significantly increases the number of meteors with measured intensity and improves the estimation of meteoroid mass distribution. Astrometry is automated to determine each image s plate coefficient using appropriate star catalogs. The images are simultaneously intensity calibrated from the contained stars to determine the photon sensitivity and the saturation level referenced above the atmosphere. The camera s spectral response is used to compensate for stellar color index and typical meteor spectra in order to report meteor light curves in traditional visual magnitude units. Recent efforts include improved camera calibration procedures, long focal length "streak" meteor photome&y and two-station track determination. Meteor44 has been used to analyze data from the 2001.2002 and 2003 MSFC Leonid observational campaigns as well as several lesser showers. The software is interactive and can be demonstrated using data from recent Leonid campaigns.

Swift, Wesley R.↗

Microchannel plate EUV detectors for the Extreme Ultraviolet Explorer

The design and operating characteristics of the prototype imaging microchannel plate (MCP) detector for the Extreme Ultraviolet Explorer (EUVE) Satellite are discussed. It is shown that this detector has achieved high position resolution performance (greater than 512 x 512 pixels) and has low (less than one percent) image distortion. In addition, the channel plate scheme used has tight pulse height distributions (less than 40 percent FWHM) for UV radiation and displays low (less than 0.2 cnt/sq cm-s) dark background counting rates. Work that has been done on EUV filters in relation to the envisaged filter and photocathode complement is also described.

Siegmund, O. H. W.↗

Multiple-Dynode-Layer Microchannel Plate

Improved microchannel-plate electron image amplifier made of stack of discrete microchannel-plate layers. New plates easier to manufacture because no need to etch long, narrow holes, to draw and bundle thin glass tubes, or to shear plates to give microchannels curvatures necessary for reduction of undesired emission of ions. Discrete dynode layers stacked with slight offset from layer to layer to form microchannel plate with curved channels. Provides for relatively fast recharging of microchannel dynodes, with consequent enhancement of performance.

Woodgate, Bruce E.↗

Crack Imaging and Quantification in Aluminum Plates with Guided Wave Wavenumber Analysis Methods

Guided wavefield analysis methods for detection and quantification of crack damage in an aluminum plate are presented in this paper. New wavenumber components created by abrupt wave changes at the structural discontinuity are identified in the frequency-wavenumber spectra. It is shown that the new wavenumbers can be used to detect and characterize the crack dimensions. Two imaging based approaches, filter reconstructed imaging and spatial wavenumber imaging, are used to demonstrate how the cracks can be evaluated with wavenumber analysis. The filter reconstructed imaging is shown to be a rapid method to map the plate and any existing damage, but with less precision in estimating crack dimensions; while the spatial wavenumber imaging provides an intensity image of spatial wavenumber values with enhanced resolution of crack dimensions. These techniques are applied to simulated wavefield data, and the simulation based studies show that spatial wavenumber imaging method is able to distinguish cracks of different severities. Laboratory experimental validation is performed for a single crack case to confirm the methods' capabilities for imaging cracks in plates.

Yu, Lingyu↗

Imaging characteristics of the Extreme Ultraviolet Explorer microchannel plate detectors

The Extreme Ultraviolet Explorer (EUVE) satellite will conduct an all-sky survey over the wavelength range from 70 A to 760 A using four grazing-incidence telescopes and seven microchannel-plate (MCP) detectors. The imaging photon-counting MCP detectors have active areas of 19.6 cm2. Photon arrival position is determined using a wedge-and-strip anode and associated pulse-encoding electronics. The imaging characteristics of the EUVE flight detectors are presented including image distortion, flat-field response, and spatial differential nonlinearity. Also included is a detailed discussion of image distortions due to the detector mechanical assembly, the wedge-and-strip anode, and the electronics. Model predictions of these distortions are compared to preflight calibration images which show distortions less than 1.3 percent rms of the detector diameter of 50 mm before correction. The plans for correcting these residual detector image distortions to less than 0.1 percent rms are also presented.

Vallerga, J. V.↗

Calibration of the Rosat High Resolution Imager (HRI)

The microchannel plate-based High Resolution Imager (HRI) is one of the focal plane instruments of the Rosat X-ray telescope that was launched on 1 June 1990. The calibration of the HRI is reported and preliminary results from the in-orbit calibration are presented. The quantum efficiency of the detector has been determined as a function of energy, the spatial variation of quantum efficiency, geometric nonlinearities, background, imaging performance, and UV sensitivity. Results of periodic tests of the temporal stability of the instrument are also reported.

Zombeck, M. V.↗

Analysis of the nebulosities near T Tauri using digital computer image processing

Direct plates of T Tauri taken with the 120-inch (3 m) and 36-inch (91 cm) Lick reflectors were digitized and analyzed using digital-computer image-processing techniques. Luminous emission protrusions extending to as far as 13-sec from T Tauri in position angles 170 deg, 210 deg, and 330 deg are shown. These features are variable and may contain a layered structure. The complex reflection nebula west of T Tauri (NGC 1555) appears to be an illuminated portion of a much larger dark nebula whose variability is due to obscuring material near the star.

Lorre, J. J.↗

Least Squares Reverse Time Migration (LSRTM) for Damage Imaging in Composite Laminates

A method for adapting least squares reverse time migration (LSRTM) for ultrasonic guided wave imaging of composite laminates is proposed in this paper. As composites become more widely used in fields such as the aerospace industry, the need for high-resolution imaging in structural health monitoring (SHM) and nondestructive evaluation (NDE) is also growing. For instance, delamination is a common problem in composite laminates, which has led to a certain degree of apprehension in the use of composite materials for load-bearing structures. Although the solver-based imaging techniques using conventional reverse time migration (RTM) methods illuminate damage with a wide range of damage-scattering effects, the resulting images do not fully define the damage regions due to the limited data acquisition aperture, sensor density, frequencies/wavelengths, and incompleteness of adjoint reconstruction. Previously, the LSRTM theory was derived by incorporating a least squares migration (LSM) algorithm into RTM, and benchmarked its high-resolution damage imaging performance for isotropic plates. To improve damage imaging in composite laminates, a process to create an ultrasonic guided wave-based LSRTM method for anisotropic materials is proposed in this paper. The derivation of the forward modeling operator and the adjoint operator is presented. Numerical case studies were conducted to show the improvement of LSRTM over RTM in mapping damage in composite plates. Multiple damage sites or damage with a complex shape were created in the numerical studies based on 1) Born approximation-based modeling or 2) reduction of the plate stiffness-based modeling. LSRTM begins by using a forward modeling process. The forward modeling accuracy for the flexural wave solver used in this study for LSRTM was also compared with the results from a three-dimensional rotated staggered grid (RSG) elastodynamic finite difference solver, previously open-sourced by NASA Langley Research Center. These benchmarking studies have shown that the LSRTM method is more effective in reducing artifacts, improving resolution, and enhancing damage model reconstruction compared to RTM in composite laminates.

Jiaze He↗

Mars 2001 Lander Mission: Measurement Synergy Through Coordinated Operations Planning And Implementation

The 2001 Mars Surveyor Program Mission includes an orbiter with a gamma ray spectrometer and a multispectral thermal imager, and a lander with an extensive set of instrumentation, a robotic arm, and the Marie Curie Rover. The Mars 2001 Science Operations Working Group (SOWG) is a subgroup of the Project Science Group that has been formed to provide coordinated planning and implementation of scientific observations, particularly for the landed portion of the mission. The SOWG will be responsible for delivery of a science plan and, during operations, generation and delivery of conflict-free sequences. This group will also develop an archive plan that is compliant with Planetary Data System (PDS) standards, and will oversee generation, validation, and delivery of integrated archives to the PDS. In this report we cover one element of the SOWG planning activities, the development of a plan that maximizes the scientific return from lander-based observations by treating the instrument packages as an integrated payload. Scientific objectives for the lander mission have been defined. They include observations focused on determining the bedrock geology of the site through analyses of rocks and also local materials found in the soils, and the surficial geology of the site, including windblown deposits and the nature and history of formation of indurated sediments such as duricrust. Of particular interest is the identification and quantification of processes related to early warm, wet conditions and the presence of hydrologic or hydrothermal cycles. Determining the nature and origin of duricrust and associated salts is -very important in this regard. Specifically, did these deposits form in the vadose zone as pore water evaporated from soils or did they form by other processes, such as deposition of volcanic aerosols? Basic information needed to address these questions includes the morphology, topography, and geologic context of landforms and materials exposed at the site, together with quantitative information on material mineralogy, chemistry, and physical properties (rock textures; soil grain size and shape distributions; degree and nature of soil induration; soil magnetic properties). The calibration targets provide radiometric and mineralogical control surfaces. The magnets allow observations of magnetic phases. Patch plates are imaged to determine adhesive and abrasive properties of soils. Coordinated mission planning is crucial for optimizing the measurement synergy among the packages included on the lander. This planning has already begun through generation of multi-sol detailed operations activities. One focus has been to develop a scenario to use the arm to dig a soil trench to a depth of tens of centimeters. The activity will be monitored through use of Pancam and RAC to ensure nominal operations and to acquire data to determine subsurface physical properties (e.g., angle of repose of trench walls). Pancam and Mini-TES observations would also provide constraints on mineralogy and texture for the walls and bottom of the trench during excavation. If desired, soils excavated at depth could be deposited on the surface and Mossbauer and APXS measurements could be acquired for these materials. Soil samples from various depths would be delivered to MECA for characterization of aqueous geochemistry and physical properties of soil grains, particularly size, shape, and hardness. These physical properties would be determined by optical and atomic force microscopy. When completed, detailed information of soil properties as a function of depth would be obtained. These various data sets would constrain our understanding of whether or not there are systematic variations in soil characteristics as a function of depth. These variations might be related, for example, to evaporative moisture losses and formation of salt deposits, thereby indicating water transport processes occurred fairly recently. Many other value-added measurement scenarios are being developed. For example, characterizing the nature and dynamics of dust deposition will be done using MIP/DART to provide deposition rates, Pancam and RAC imaging of lander and rover surfaces to extrapolate these measurements to other areas, and a variety of measurements to determine if the bulk loose soil has the same characteristics as dust that accumulates during the mission. Bedrock geology of the site is primarily an APEX-focus setting, mineralogy, and texture, and APXS data to be we interest will be to determine the extent to which rock hydrothermal processes, given that APEX is the precursor 4 and 2005 rover missions. Additional information is contained in the original.

Arvidson, R.↗

Medical electronics: A need and a challenge

Space programs have led to the development of telemetry pills for diagnosis of diseases of the digestive tract, reusable X-ray image storage plates that require no chemical processing, and muscular augmentation systems for the handicapped. These examples, together with countless other examples of technological innovation that can be drawn from research and development programs supported by government funds, offer a potential opportunity to stimulate growth and to control rising costs in medical electronics.

Dimeoff, J.↗

Optical studies of the regions of the gamma-ray bursts of 19 November, 1978 and 5 March, 1979

Optical studies were made of two well-located gamma-ray burst regions in the Southern Hemisphere using the 1.5 m telescope at the Cerro Tololo Inter-American Observatory in Chile. Multi-filter image tube plates and UBV photometry surveys were made of both regions. The field of the 19 November, 1978 gamma-ray burst shows no early star or star with unusual colors out to several diameters of the nominal error box. The region of the 5 March, 1979 gamma-ray burst, which includes N49, contains several blue giants in the LMC, two of which deserve further study.

Fishman, G. J.↗

The soft X-ray/EUV calibration facility at the University of Colorado

The components of the calibration facility at the University of Colorado are described. The system is capable of analyzing the performance of optical components in the wavelength range from 2.7 to 2500 A. The system uses two light sources: a water-cooled hollow cathode gas discharge source and a soft X-ray source. The 2.2-m grazing incidence monochrometer, slits, large chamber, and computer-controlled manipulator are examined. The NBS aluminum oxide photodiode, a flowing gas proportional counter, and an imaging microchannel plate device are employed to detect the light. The optics, detectors, and data acquisition system are computer controlled. The facility is applicable for evaluating the performance of diffraction gratings, multilayer mirrors, reflective coatings, spectrographs, surface roughness scattering, and absolute detector efficiencies. Examples demonstrating the capabilities of the facility and a diagram of the facility are presented.

Windt, David L.↗