Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Ignition delay time”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Shock tube ignition delay times and methane time-histories measurements during excess CO 2 diluted oxy-methane combustion

The combustion of methane in air results in large amounts of CO 2 and NO X emissions. In order to reduce the NO X emissions, one possible solution is the oxy-methane combustion with large CO 2 dilution so that the combustion products can be reduced mainly to CO 2 and H 2 O. However, there are very few studies on the chemical kinetics of oxy-methane combustion in a CO 2 diluted environment. In this study, methane time-histories, CH* emission profiles, and pressure time-histories measurements were conducted behind reflected shock waves to gain insight into the effects of CO 2 dilution of the gas mixtures on the ignition of methane. The measurements were carried out for mixtures of CH 4 , CO 2 and O 2 in argon bath gas at temperatures of 1577–2144 K, pressures of 0.53–4.4 atm, equivalence ratios (Φ) of 0.5, 1, and 2, and CO 2 mole fractions (X CO2 ) of 0, 30, and 60%. The laser absorption measurements were conducted using a continuous wave distributed feedback interband cascade laser (DFB ICL) centered at 3403.4 nm. The results showed the decrease of activation energy and the increase of ignition delay time as the amount of CO 2 dilution was increased. However, the changes were minor and within the experimental uncertainties of the measurements. Also, the results were compared to the predictions of two different natural gas mechanisms: GRI 3.0 and AramcoMech 1.3 mechanisms. In general the predictions were reasonable when compared to the experimental data; however, there were discrepancies at some conditions. Three different influences of CO 2 addition to the argon bath gas in regards to chemistry, collision efficiencies, and heat capacities were examined. In addition, the present study included experimentally obtained correlations for absorption cross sections of methane for its P(8) line in the v3 band in argon bath gas with and without carbon-dioxide dilutions at temperatures between 1200 < T < 2000 K and pressures between 0.7 < P < 1.2 atm.

42 ENGINEERING↗

Ignition delay time and CO time-history measurements in a shock tube during high performance jet fuel surrogate combustion

The chemical kinetics of diisobutylene, a proposed biofuel, has been studied behind reflected shock waves near 10 atm over a temperature range of 1186 – 1414 K. A stoichiometric mixture consisting of 0.15% diisobutylene was used to investigate ignition behavior and speciation during oxidation experiments performed in a shock tube. Time resolved measurements of carbon monoxide were measured behind reflected shock waves with a continuous wave quantum cascade laser centered at a frequency of 2046.20 cm^-1 using a fixed-wavelength spectroscopy scheme.

09 BIOMASS FUELS↗

Ignition delay times of cyclopentene oxygen argon mixtures

The oxidation of cyclopentene was studied experimentally to expand the database on pyrolysis and the reaction products of five carbon unsaturated ring compounds. Pyrolysis was carried out in a single-pulse shock tube. Data were gathered on the shock speed, wall pressure, and reflected shock temperatures. Four different mixtures of C5H8, O2 and Ar, ranging from 0.25-1 percent cyclopentene and 1.75-7 percent O2, were examined in 76 different trials. The data showed a shock temperature range of 1323-1816 K and a pressure range of 1.67-7.36 atmospheres. A student-t test analysis of the results led to definition of an ignition delay equation accurate to the 2-sigma level.

Burcat, A.↗

High-Fuel Loading Ignition Delay Time Characterization of Hydrogen/Natural Gas/Ammonia at Gas Turbine-Relevant Conditions Inside a High-Pressure Shock Tube

Abstract This study explores the combustion characterization of high-fuel percentage, air-diluted mixtures of H2 mixed with natural gas (NG) as well as mixtures of H2 and NH3 at temperatures and pressures relevant to turbine operating conditions (20–30 bar, 1000–1500 K). Lower temperatures (below 1070 K) exhibit preignition characteristics due to non-homogeneity. An attempt to mitigate these occurrences at high pressures is investigated using the constrained reaction volume (CRV) stage-filling technique. Due to the need to further refine the facility CRV stage-filling uncertainty, only higher temperature data will be interpreted at this time. The test conditions in this study closely replicate the temperatures, pressures, and mixtures that would be seen in hydrogen-powered gas turbines, making it the first to explore such conditions. The experimental IDTs were compared against the current state-of-the-art chemical kinetic models for mechanism validation. The current work will advance H2-powered turbines and aims to determine the optimum molecular ratio of H2 when mixed with natural gas.

Pierro, Michael↗

Co-optima fuels combustion: A comprehensive experimental investigation of prenol isomers

Carbon monoxide time-histories, ignition delay times, and laminar burning velocity measurements are reported for the oxidation of 3-methyl-2-buten-1-ol (prenol) and 3-methyl-3-buten-1-ol (isoprenol). These prenols are fuel candidates outlined by the U.S. Department of Energy’s Co-Optimization of Fuels and Engines (Co-Optima) program. The laminar burning velocity measurements were conducted for two fuels with synthetic air within a constant-volume spherical combustion chamber at initial conditions of 428 K and 1 atm for a range of equivalence ratios from 0.75 to 1.50. The laminar burning velocities of the two fuels were found to be similar, and the maximum value occurred at an equivalence ratio near 1.0. Carbon monoxide time-histories and ignition delay times were recorded behind reflected shockwaves in a double-diaphragm, heated shock tube over the temperature range 1269–1472 K near 9.4 atm with a mixture of 0.05% fuel/0.35% O 2 /99.6% Ar. Comparisons with predictions of a detailed chemical kinetic mechanism from the literature were provided. Current model predictions overpredicted both the ignition delay time and the max CO yield; however, the model captured the profile of CO formation well. Detailed uncertainty and sensitivity analyses were carried out to identify important reactions that need attention for accurate prediction of these fuel’s chemistry. Further investigation into the rate of C 3 H 3 + O 2 = CH 2 CO + HCO reaction was suggested based on current experiments. In conclusion, the experimental data and analysis presented here is critical in the development, validation and improvement of kinetic models of these promising Co-Optima fuels.

09 BIOMASS FUELS↗

Auto-ignition during instationary jet evolution of dimethyl ether (DME) in a high-pressure atmosphere

The auto-ignition process during transient injection of gaseous dimethyl ether (DME) in a constant high-pressure atmosphere is studied experimentally by laser-optical methods and compared with numerical calculations. With different non-intrusive measurement techniques jet properties and auto-ignition are investigated at high temporal and spatial resolution. The open jet penetrates a constant pressure oxidative atmosphere of up to 4 MPa. During the transient evolution, the fuel jet entrains air at up to 720 K. The subsequent auto-ignition of the ignitable part of the jet occurs simultaneously over a wide spatial extension. The ignition delay times are not affected by variation of the nozzle exit velocity. Thus, the low-temperature oxidation is slow compared with the shorter time scales of mixing, so that chemical kinetics is dominating the process. The typical two-stage ignition is resolved optically with high-speed shadowgraphy at a sampling rate of 10 kHz. The 2D fields of jet velocity and transient mixture fraction are measured phase-coupled with Particle Image Velocimetry (PIV) and Tracer Laser Induced Fluorescence (LIF) during the time-frame of ignition. The instationary Probability Density Functions (PDF) of mixture fraction are described very well by Beta functions within the complete area of the open jet. Additional 1D flamelet simulations of the auto-ignition process are computed with a detailed reaction mechanism for DME [S. Fischer, F. Dryer, H. Curran, Int. J. Chem. Kinet. 32 (12) (2000) 713-740; H. Curran, S. Fischer, F. Dryer, Int. J. Chem. Kinet. 32 (12) (2000) 741-759]. Calculated ignition delay times are in very good agreement with the measured mean ignition delay times of 3 ms. Supplemental flamelet simulations address the influence of DME and air temperature, pressure and strain. Underneath a critical strain rate the air temperature is identified to be the most sensitive factor on ignition delay time. (author)

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗