Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISOTOPE RATIO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

ICP-MS For Analysis of Lithium Isotopic Ratios in Materials Highly Enriched in 7Li - CRADA 626 (Abstract)

The purpose of this project is to develop analytical methods that can be deployed for analysis of lithium isotope enrichment products. One method involves rapid, high-throughput, relatively low precision analysis for direct monitoring of enrichment processes. A second method involves slower, but more precise analysis of final products of the enrichment process. We will use commercially available analytical equipment (quadrupole base inductively coupled plasma mass spectrometry and multi-collector magnetic sector inductively coupled plasma mass spectrometry) so that the analytical methods developed can be applied broadly.

07 ISOTOPE AND RADIATION SOURCES↗

Characterizing the Uncertainty of Measurement of Traceable Isotope Ratios with Bayesian Statistical Techniques

Analytical techniques such as multicollector—inductively coupled plasma—mass spectrometry (MC-ICP-MS) are routinely employed at SRNL, other National Laboratories, and in academia to determine the precise isotopic composition of diverse natural and anthropogenic samples (e.g., rocks and nuclear materials). Quantifying and reporting uncertainty in such analyses, while regularly performed, have a rigorous statistical foundation. The Guide to the Expression of Uncertainty in Measurement 4 (GUM) outlines conventional techniques used to assess such uncertainty. As the accessibility and speed of statistical computing increase, there is a need to modernize conventional techniques. For example, Supplement 1 to the 3rd to the GUM suggests the use of approximation methods as an updated approach to the GUM.

McLarty, Ellis C.↗

Method Development for Measuring U Isotope Ratios by Laser Ablation MC-ICP-MS. Task 1: Hardware Setup

The aim of this project is to develop methodology to identify and analyze U and Pu containing particles using laser ablation MC-ICP-MS. The final methodology will ultimately be described in a detailed procedural document that will be shared with IAEA-NWAL laboratories. In this report, we describe the Task-1 deliverable; the setup and optimization of hardware required to perform U isotopic analyses by laser ablation MC-ICP-MS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of U Isotope Ratios by Laser Ablation MC-ICP-MS for IAEA Safeguards

This project will develop methodology to identify and analyze U and Pu containing particles using laser ablation MC-ICP-MS. The proposed work will involve: i) setup and optimization of the LA-MC-ICP-MS system, ii) testing and validation by analysis of QC standards, iii) designing analytical protocols for single particles, and iv) developing a data processing system. Ultimately, this project will output a detailed operating procedure documenting the experimental techniques and data processing routines required to perform particle identification and analysis by laser ablation MC-ICP-MS, that can be shared with IAEANWAL laboratories.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Certification of Uranium Isotope Amount Ratios in a Suite of Uranium Ore Concentrate Certified Reference Materials

Here, in this study, data from thirteen laboratories from around the world are presented for a successful certification of uranium isotope ratios in uranium ore concentrate (UOC) certified reference materials from the National Research Council Canada. Different mass spectrometric measurement principles (including SF-ICP-MS, quadruple ICP-MS, TIMS, MC-ICP-MS, SIMS and AMS) and measurement procedures were employed. In general, data from all sources exhibit good consistency with TIMS and MC-ICP-MS showing superior performance. The three candidate UOC CRMs (UCLO-1, UCHI-1 and UPER-1) have natural uranium isotope ratios with certified values of 0.5304(7) x 10 -4 , 0.5475(2) x 10 -4 and 0.5361(4) x 10 -4 for n( 234 U)/n( 238 U) and 0.007 2563(13), 0.007 2563(10) and 0.007 2542(11) for n( 235 U)/n( 238 U), respectively, with expanded uncertainty (k = 2) applicable to the last digit of the value given in the parentheses. Information values for n( 236 U)/n( 238 U) in these three CRMs, measured by AMS, are also provided: 10 x 10 -12 , 200 x 10 -12 and 22 x 10 -12 . The uncertainties of the proposed certified values of uranium isotope ratios in UOC CRMs are superior to available reference materials, and the values of n( 234 U)/n( 238 U) and n( 236 U)/n( 238 U) show significant variation among the three CRMs.

58 GEOSCIENCES↗

Evaluation of several relevant fractionation processes as possible explanation for radioxenon isotopic activity ratios in samples taken near underground nuclear explosions in shafts and tunnels

Gas samples taken from two historic underground nuclear tests done in 1989 at the Nevada National Security Site (NNSS), formerly the Nevada Test Site (NTS), were examined to determine how xenon isotopes fractionate because of early-time cavity processes, transport through the rock, or dispersal through tunnels. Xenon isotopes are currently being used to distinguish civilian sources of xenon in the atmosphere from sources associated with underground nuclear explosions (UNEs). The two nuclear tests included (1) BARNWELL, a test conducted in a vertical shaft approximately 600 m below ground surface at Pahute Mesa, and (2) DISKO ELM, a horizontal line-of-sight test done in P-tunnel approximately 261 m below the surface of Aqueduct Mesa. Numerical flow and transport models developed for the two sites had mixed success when attempting to match the observed xenon isotope ratios. At the BARNWELL site, the simulated xenon isotope ratios were consistent with measurements from the chimney and ground surface and appeared to have been affected primarily by fractionation during subsurface transport. At the DISKO ELM site, samples taken from two elevations in the chimney failed to show the degree of fractionation predicted by the models during transport and did not show evidence for significant fractionation due to early-time condensation of refractory xenon-precursor radionuclides into the melt glass. Gas samples taken from the adjacent tunnels in the days following the test showed mixed evidence for early-time separation of xenon isotopes from their iodine precursors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

LANL contributions to isoWater R package

The ratio of heavy-to-light stable isotope abundance in water vapor is a tracer of atmospheric processes including evapotranspiration, condensation, mixing, and transport. Measurements of these isotope ratios at the surface, in the atmospheric column, or from satellites provide insights into atmospheric processes that cannot be gained from measurements of water vapor mixing ratios alone. A number of theoretical models for how water vapor isotope ratios should vary in response to atmospheric processes have been developed, and LANL contributions to the isoWater R package provides a simplified interface for calculating expected vapor isotope ratios based on these models and adding them to plots of water vapor isotope ratios.

Fiorella, Richard↗

A Machine Learning Method for the Forensics Attribution of Separated Plutonium

Plutonium (Pu) source attribution would be a powerful tool to support nuclear nonproliferation efforts. This capability to find the source of a Pu sample would act as a deterrent to smuggling efforts, and also help regulatory agencies verify declared nuclear activities. Work at Texas A&M University yielded a nuclear forensics methodology, which is capable of determining separated Pu’s reactor of origin, fuel burnup, and the time since irradiation (TSI)—three parameters of interest. The methodology used a set of ten intra-element isotopic ratios found in separated Pu, which was compared to a library of isotopic ratio values produced using neutronics simulations for reactors of interest. By calculating the probability that unknown Pu sample’s isotopic ratio set matched a set in the library, the methodology could predict the three parameters of interest of the sample. One shortcoming of this methodology was an inability to correctly attribute spoofed Pu, where Pu sourced from two different reactors or two different fuel burnup levels are mixed. A new methodology to rectify this vulnerability using machine learning (ML) technique is developed, instead of the maximum likelihood calculation previously used and the results are satisfactory. The ML approach leverages the existing simulated data for training the algorithm, but use them efficiently by only using intra-element isotope ratios that contribute to the attribution one of the three parameters at a time. Previously, all isotope ratios were used to attribute all three parameters together. The new methodology attributes the Pu parameters in three steps, one for each parameter, rather than resolving all of the three parameters simultaneously like the previous maximum likelihood approach. First, a support vector machine classifier with a set of seven isotopic ratios finds the reactor of origin and a set of regression models trained using gaussian process predicts the burnup with a different set of seven isotopes. Finally, TSI is calculated analytically using decay equations. Thus far, the new methodology is capable of attributing pure Pu samples and has been validated using experimental data. The next step will to be augment the classifier training data set with spoofed Pu data.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Accuracy and precision of ESI-Orbitrap-IRMS observations of hours to tens of hours via reservoir injection

Here, orbitrap isotope ratio mass spectrometry (Orbitrap-IRMS) has recently been applied to high-precision, natural-abundance isotope ratio measurements of a diverse range of compounds, including amino acids, oxyanions, fatty acids, and metals. These measurements can characterize many isotope ratios simultaneously at high (≈1.0‰) precision. In a successful experiment, observed precision will track the shot-noise limit and be limited by experimental time. Some isotope ratios, for example those involving 17 O in organic compounds or multiply-substituted (‘clumped’) isotopologues, require experimental times of hours to tens of hours to achieve desired precision, while current sample introduction techniques focus on observations on the order of seconds to tens of minutes. In this study, we characterize Orbitrap-IRMS performance for three long duration measurements (individual acquisitions ≥1 h and as long as 24 h) using an automated reservoir injection system coupled to a Q Exactive HF Orbitrap with an electrospray ionization (ESI) source. First, we characterize long-term intra-measurement stability through a 24-h long measurement of acetone. We report the following isotope ratios and precisions (as acquisition errors, errors on the observed ratio within this measurement (σ AE )): 13 C/ 12 C (σ AE = 0.07‰), 17 O/ 16 O (σ AE = 1.1‰), 18 O/ 16 O (σ AE = 0.3‰), and 13 C 13 C/ 12 C (σ AE = 0.65‰). The σ AE of each tracks the shot noise limit throughout and is limited by the challenging conditions (high resolution and low numbers of ions per scan) required for 17 O/ 16 O measurement in the presence of 13 C via Orbitrap. Second, we characterize inter-measurement stability via a sequence of seven 75-min analyses of perchlorate. We observe the following ratios and acquisition errors: 37 Cl/ 35 Cl (σ AE = 0.09‰); 17 O/ 16 O (σ AE = 1.6‰); 18 O/ 16 O (σ AE = 0.7‰), 37 Cl 17 O/ 35 Cl 16 O (σ AE = 2.7‰), and 37 Cl 18 O/ 35 Cl 16 O (σ AE = 1.2‰). However, we find that inter-measurement drift between acquisitions limits our accuracy and precision for standardized measurements (i.e., error on reported δ values) to ≈1‰ for the 37 Cl/ 35 Cl measurement. Hence, the benefits of low σ AE may not be fully realized. Third, we demonstrate accuracy via sample/standard comparisons of a methionine sample with 13 C enrichment of ≈20‰ relative to a known standard. Using a sequence of seven 60-min analyses, we recover the following isotope ratios and standardized precisions (i.e., error on reported δ values, denoted propagated acquisition errors, σ PAE ): 33 S/ 32 S (σ PAE = 1.0‰), 34 S/ 32 S (σ PAE = 0.7‰), 15 N/ 14 N (σ PAE = 2.1‰), 2 H/ 1 H (σ PAE = 3.2‰), 13 C/ 12 C (σ PAE = 0.4‰), 18 O/ 16 O (σ PAE = 1.6‰), & 13 C 13 C/ 12 C (σ PAE = 2.8‰) with confirmation of accurate results for the known 13 C/ 12 C and 13 C 13 C/ 12 C enrichments. Together, our results demonstrate the viability of Orbitrap-IRMS for long duration measurements of diverse sample types via an automated reservoir injection system. Inter-measurement stability remains a challenge; we expect our methods to be most applicable to extended measurements of hard-to-observe properties, such as 17 O in organics and clumped isotopologues.

58 GEOSCIENCES↗

Organic contamination detection for isotopic analysis of water by laser spectroscopy

Hydrogen and oxygen stable isotope ratios (δ 2 H, δ 17 O, and δ 18 O values) are commonly used tracers of water. These ratios can be measured by isotope ratio infrared spectroscopy (IRIS). However, IRIS approaches are prone to errors induced by organic compounds present in plant, soil, and natural water samples. A novel approach using 17 O-excess values has shown promise for flagging spectrally contaminated plant samples during IRIS analysis. A systematic assessment of this flagging system is needed to prove it useful. Errors induced by methanol and ethanol water mixtures on measured IRIS and isotope ratio mass spectrometry (IRMS) results were evaluated. For IRIS analyses both liquid- and vapour-mode (via direct vapour equilibration) methods are used. The δ 2 H, δ 17 O, and δ 18 O values were measured and compared with known reference values to determine the errors induced by methanol and ethanol contamination. In addition, the 17 O-excess contamination detection approach was tested. This is a post-processing detection tool for both liquid and vapour IRIS triple-isotope analyses, utilizing calculated 17 O-excess values to flag contaminated samples. Organic contamination induced significant errors in IRIS results, not seen in IRMS results. Methanol caused larger errors than ethanol. Results from vapour-IRIS analyses had larger errors than those from liquid-IRIS analyses. The 17 O-excess approach identified methanol driven error in liquid- and vapour-mode IRIS samples at levels where isotope results became unacceptably erroneous. For ethanol contaminated samples, a mix of erroneous and correct flagging occurred with the 17 O-excess method. Here our results indicate that methanol is the more problematic contaminant for data corruption. The 17 O-excess method was therefore useful for data quality control. Organic contamination caused significant errors in IRIS stable isotope results. These errors were larger during vapour analyses than during liquid IRIS analyses, and larger for methanol than ethanol contamination. The 17 O-excess method is highly sensitive for detecting narrowband (methanol) contamination error in vapour and liquid analysis modes in IRIS.

60 APPLIED LIFE SCIENCES↗

A new highly enriched 233 U reference material for improved simultaneous determination of uranium amount and isotope amount ratios in trace level samples

A highly-enriched 233 U reference material (>0.99987 n( 233 U)/n(U)) has been prepared and characterized for use as an isotope dilution mass spectrometry spike. An ion exchange separation was performed on 1 g of high purity 233 U to further reduce trace amounts of contaminant Pu in the material. The purified 233 U was then prepared as a master solution which was analyzed for molality of uranium by modified Davies and Gray titration. A portion of the master solution was quantitatively diluted and dispensed for reference material units. Selected units were analyzed for verification of uranium amount and to characterize uranium isotope amount ratios by multi-collector inductively couple plasma mass spectrometry. Furthermore, modelling of spike-corrected isotopic data show that the new spike will enable simultaneous measurements of uranium amount and isotope amount ratios with resulting uncertainties that are substantially less sensitive to over spiking than widely used 233 U certified reference materials.

233U↗

Real-Time Inventory Change Detection for the Protactinium Decay Inventory of the Molten Salt Breeder Reactor

This work presents a novel monitoring method for detecting material loss from the decay inventory of the molten salt breeder reactor (MSBR) by monitoring for changes to the system dynamics using an isotopic ratio. Here the isotopic masses in the decay inventory of a MSBR were simulated under several material loss scenarios. In each case, the ratio of 231 Pa to 233 Pa served as a sensitive and lasting indicator of material loss. This isotope ratio quickly decreased outside the normal range after a material loss, and the ratio remained depressed for several years after the loss. The dynamics of this ratio were driven by the periodic batch discard from the decay inventory every 220 days, which was specified in the MSBR design to periodically remove fission product buildup. For this method, isotopic ratios were found to be rapid and enduring indicators of inventory change if they comprise a pair with a short half-life (e.g., 233 Pa) and a long half-life (e.g., 231 Pa) relative to the effective half-life induced by the driving system process (e.g., the batch discard cycle). Using such an isotope pair enabled a method to monitor for changes to the effective half-life of the system and by extension changes to the system inputs and outputs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗