Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ISO”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The ISO View of Palomar-Green Quasars

Mining the ISO data archive we provide the complete ISO view of PG quasars containing 64 infrared spectral energy distributions between 5 and 200 mu m. About half of the sample was supplemented by MAMBO and SCUBA (sub-)millimeter data. Since the PG quasars were selected optically, the high infrared detection rate of more than 80% suggests that every quasar possesses luminous to hyper-luminous dust emission with dust masses comparable to Seyferts and ultra-luminous IR galaxies (ULIRGs). The gas to-dust mass ratio (of those sources where CO measurements are available in the literature) is consistent with the galactic value providing further evidence for the thermal nature of the IR emission of radio quiet quasars. The SEDs represent templates of unprecedented detail and sensitivity. We suggest that the diversity of the SEDs reflects largely the evolution of the dust distribution, and we propose a classification of the SED shapes as well as an evolutionary scheme in which this variety can be understood. During the evolution the surrounding dust redistributes, settling more and more into a torus/disk like configuration, while the SEDs show an initial FIR bump, then an increasing MIR emission and a steeper near- to mid-infrared slope, both of which finally also decrease. Regarding cosmic evolution, our hyper-luminous quasars in the "local" universe at z=l do not show the hyper-luminous (LFIR >? 10(exp 13) L(sub sun)) starburst activity inferred for z=4 quasars detected in several (sub-)millimeter surveys. In view of several caveats this difference should be established further, but it already suggests that in the early dense universe stronger merger events led to more powerful starbursts accompanying the quasar phenomenon, while at later cosmic epochs any coeval starbursts obviously do not reach that high power and are outshone by the AGN. Additional information is included in the original extended abstract.

Haas, M.↗

Testing the E(sub peak)-E(sub iso) Relation for GRBs Detected by Swift and Suzaku-WAM

One of the most prominent, yet controversial associations derived from the ensemble of prompt-phase observations of gamma-ray bursts (GRBs) is the apparent correlation in the source frame between the peak energy (E(sub peak)) of the nuF(nu) spectrum and the isotropic radiated energy, E(sub iso). Since most gamma-ray bursts (GRBs) have E(sub peak) above the energy range (15-150 keV) of the Burst Alert Telescope (BAT) on Swift, determining accurate E(sub peak) values for large numbers of Swift bursts has been difficult. However, by combining data from Swift/BAT and the Suzaku Wide-band All-Sky Monitor (WAM), which covers the energy range from 50-5000 keV, for bursts which are simultaneously detected ; one can accurately fit E(sub peak) and E(sub iso) and test the relationship between them for the Swift sample. Between the launch of Suzaku in July 2005 and the end of March 2009, there were 45 gamma-ray bursts (GRBs) which triggered both Swift/BAT and WAM and an additional 47 bursts which triggered Swift and were detected by WAM, but did not trigger. A BAT-WAM team has cross-calibrated the two instruments using GRBs, and we are now able to perform joint fits on these bursts to determine spectral parameters. For those bursts with spectroscopic redshifts.. we can also calculate the isotropic energy. Here we present the results of joint Swift/BAT-Suzaku/WAM spectral fits for 86 of the bursts detected by the two instruments. We show that the distribution of spectral fit parameters is consistent with distributions from earlier missions and confirm that Swift, bursts are consistent with earlier reported relationships between Epeak and isotropic energy. We show through time-resolved spectroscopy that individual burst pulses are also consistent with this relationship.

Krimm, H. A.↗

The ISO-IRAS Faint Galaxy Survey: ISOCAM Results

The ISO-IRAS Faint Galaxy Survey (IIFGS) is a program designed to produce one of the largest and deepest samples of luminous galaxies possible with present facilities.

galaxies infrared ISO IRAS↗

ISO 191* Revisions and Amendments

ISO standards have changed recently in response to new requirements from introduced by NASA, NOAA, and other ESIP members. These changes address important uses cases related to identification, parameter metadata, and platform/instrument/sensor metadata. Each change will be described along with discussion of how they may be used.

data quality↗

Estimation of terrain iso-gradients from a stochastic range data measurement matrix

The problem of estimating terrain iso-gradients for an autonomous roving vehicle is complicated by the measurement error inherent in the range data matrix. In this paper, the in-path and cross-path slopes at each data point in the multivariable range matrix are expressed in terms of parameters at that data point and those at its surrounding points. The sensitivity in the change of these slopes - due to the errors in measurements in range, elevation angle and azimuth angle are formulated. These sensitivities are used to determine the appropriate statistics of the gradient, which are then used to describe the terrain with a known probability of accuracy.

Shen, C. N.↗

Panel C report: Standards needed for the use of ISO Open Systems Interconnection - basic reference model

The use of an International Standards Organization (ISO) Open Systems Interconnection (OSI) Reference Model and its relevance to interconnecting an Applications Data Service (ADS) pilot program for data sharing is discussed. A top level mapping between the conjectured ADS requirements and identified layers within the OSI Reference Model was performed. It was concluded that the OSI model represents an orderly architecture for the ADS networking planning and that the protocols being developed by the National Bureau of Standards offer the best available implementation approach.

Source record↗

Imaging Spectrometric Observatory (ISO)

The imaging spectrometric observatory (ISO) is discussed. The objectives of this instrument are to measure the spectral signatures of a large range of minor constituents, metastable, and excited species of both atomic and molecular ions, and neutrals in the atmosphere (from the stratosphere to the upper thermosphere). The instrument is composed of five identical spectrometers, each restricted to a given spectral range between 20 and 1200 nanometers designed for high speed operation as an imaging device. Each module is an imaging scanning spectrometer with coincident 0.5 x 0.007 degree field of view.

Roberts, W. T.↗

Imaging Spectrometric Observatory (ISO)

The imaging spectrometric observatory (ISO) is discussed. The objectives of this instrument are to measure the spectral signatures of a large range of minor constituents, metastable, and excited species of both atomic and molecular ions, and neutrals in the atmosphere (from the stratosphere to the upper thermosphere). The instrument is composed of five identical spectrometers, each restricted to a given spectral range between 20 and 1200 nanometers designed for high speed operation as an imaging device. Each module is an imaging scanning spectrometer with coincident 0.5 x 0.007 degree field of view.

Roberts, B.↗

Detector systems for ISO's photometer ISOPHOT

One of the four focal plane instruments of the Infrared Space Observatory (ISO) is ISOPHOT, a photopolarimeter for the wavelength region 3 to 200 microns. Each experiment occupies a quadrant of the focal plane. The telescope beam is directed into each experiment by means of a pyramid mirror and by tilting the satellite. The diameter of the unvignetted field of view is 3 arcmin or 7.85 mm in the focal plane (1 mm = 23 arcsec). The temperatures provided are 3 K for cooling the detector systems and 8 K for the experiment structure. Available detectors are described along with the current status of the experiment.

Wolf, J.↗

Development of InSb and Si:Ga arrays for ISO camera

The Infrared Space Observatory (ISO) satellite will contain a 60 cm telescope. A 4 faces pyramid mirror feeds each experiment with a 3 arc minute part of the telescope field of view. The camera system is described. The arrays for the 3 to 5 and 5 to 17 micron channel are also discussed.

Sibille, F.↗

Design and status of the detector block for the ISO-SWS

The Short Wave Spectrometer (SWS) is one of the two spectrometers for the Infrared Space Observatory (ISO). It consists of a pair of grating spectrometers and a Fabry-Perot interferometer. Together, the grating spectrometers cover the wavelength range 2.4 to 45 microns, at a resolution between 1000 and 2000. The Fabry-Perot interferometer, in series with one of the grating spectrometers, provides a resolution of about 20,000 at the wavelengths between 15 and 35 microns. The SWS is being built by the Space Research Organization of the Netherlands and the Max Planck Institute for Extraterrestrial Physics in Garching, Germany. The spectrometer has 52 discrete detectors, most of which are bulk detectors. In the design of the spectrometer, the main emphasis is on the sensitivity of the individual channels, rather than on the number of detectors. This was one of the main reasons to select non-destructive read-out circuits, with a separate heated-JFET pre-amplifier for each individual detector. The signals are amplified and filtered in parallel. The engineering tests on the SWS detector block have not yet been completed. The design of the detector block is described and the present problem areas are indicated.

Luinge, W.↗

ISO camera array development status

A short outline is given of the Infrared Space Observatory Camera (ISOCAM), one of the 4 instruments onboard the Infrared Space Observatory (ISO), with the current status of its two 32x32 arrays, an InSb charge injection device (CID) and a Si:Ga direct read-out (DRO), and the results of the in orbit radiation simulation with gamma ray sources. A tentative technique for the evaluation of the flat fielding accuracy is also proposed.

Sibille, F.↗

Cryogenic mechanisms for scanning and interchange of the Fabry-Perot interferometers in the ISO long wavelength spectrometer

The Infrared Space Observatory (ISO) is an ESA cornerstone mission for infrared astronomy. Schedules for launch in 1993, its four scientific instruments will provide unprecedented sensitivity and spectral resolution at wavelengths which are inaccessible using ground-based techniques. One of these, the Long Wavelength Spectrometer (LWS), will operate in the 45 to 180 micron region (Emery et. al., 1985) and features two Fabry-Perot interferometers mounted on an interchange mechanism. The entire payload module of the spacecraft, comprising the 60 cm telescope and the four focal plane instruments, is maintained at 2 to 4 K by an onboard supply of liquid helium. The mechanical design and testing of the cryogenic interferometer and interchange mechanisms are described.

Davis, G. R.↗

Preliminary measurements of mesospheric OH X 2Pi by ISO on Atlas 1

The Imaging Spectrometric Observatory (ISO) carried by the Atlas 1 mission conducted observations of the resonance fluorescence of the OH radical, on whose bases a density profile has been determined at 70-80 km altitude. OH observations were conducted during most of the dayside phases during the mission, covering much of the Northern Hemisphere to 57 deg N latitude. Attention is given to results from an observation at 39 deg N, where OH densities rapidly decreased above 80 km.

Morgan, M. F.↗

The ISO SWS on-line system

The software which is currently being developed for the Short Wavelength Spectrometer (SWS) of the Infrared Space Observatory (ISO) is described. The spectrometer has a wide range of capabilities in the 2-45 micron infrared band. SWS contains two independent gratings, one for the long and one for the short wavelength section of the band. With the gratings a spectral resolution of approximately 1000 to approximately 2500 can be obtained. The instrument also contains two Fabry-Perault's yielding a resolution between approximately 1000 and approximately 20000. Software is currently being developed for the acquisition, calibration, and analysis of SWS data. The software is firstly required to run in a pipeline mode without human interaction, to process data as they are received from the telescope. However, both for testing and calibration of the instrument as well as for evaluation of the planned operating procedures the software should also be suitable for interactive use. Thirdly the same software will be used for long term characterization of the instrument. The software must work properly within the environment designed by the European Space Agency (ESA) for the spacecraft operations. As a result strict constraints are put on I/O devices, throughput etc.

Roelfsema, P. R.↗