Application of artificial intelligence methods in the international roughness index prediction of rigid and composite pavements: a systematic review

The International Roughness Index (IRI) is a widely adopted metric for quantifying pavement roughness, directly influencing vehicle safety, ride comfort, and overall roadway performance. In recent years, the use of Machine Learning (ML) models for IRI prediction has gained momentum, with the goal of improving the allocation of maintenance and rehabilitation resources by enabling accurate assessments of pavement conditions. Most prior reviews, however, have concentrated on flexible pavements, leaving a notable gap regarding rigid and composite pavements. To address this gap, the present study conducts a systematic review of Artificial Intelligence (AI) methods applied to IRI prediction for rigid and composite pavements. Literature published between 2004 and 2025 is synthesized to highlight prevailing trends, methodological contributions, and directions for future research. Particular attention is given to the types of models employed, the datasets used for training and validation, and the role of input variables and data-processing strategies. Across the included studies, ensemble learning methods (especially gradient boosting variants such as XGBoost), artificial neural networks, and hybrid architectures frequently achieved high predictive skill, with several models reporting test-set coefficients of determination approaching 0.9–0.96, indicating strong potential for capturing the influence of traffic, pavement structure, and climatic factors. Since these results are obtained from heterogeneous datasets and evaluation protocols, they are interpreted qualitatively rather than as strict cross-study rankings. Analysis of input variables revealed that pavement age and initial IRI were included in 91% (21 of 23) and 78% (18 of 23) of studies, respectively. Climatic variables such as the freezing index appeared in 57% (13 of 23), while traffic-related factors were considered in 65% (15 of 23). The findings underscore the importance of standardized, high-quality datasets, such as those from the Long-Term Pavement Performance (LTPP) program, along with data consistency, model interpretability, computational efficiency, and replicability in enhancing IRI prediction. Future research should focus on incorporating input variable selection techniques to identify the most influential predictors, thereby improving accuracy and robustness. Integrating these approaches with advanced non-linear data-driven models, coupled with robust hyperparameter optimization, holds considerable promise for strengthening the reliability of IRI prediction and supporting resilient pavement management strategies.

42 ENGINEERING↗

Ice Recrystallization Inhibition Activity of Soy Protein Hydrolysates

Identifying and developing ice recrystallization inhibitors from sustainable food proteins such as soy protein isolate (SPI) can lead to practical applications in both pharmaceutical and food industries. Here, the objective of this study was to investigate the ice recrystallization inhibition (IRI) activity of SPI hydrolysates, and this was achieved by using an IRI activity-guided fractionation approach and relating IRI activity to interfacial molecular activity measured by vibrational sum frequency generation (VSFG). In addition, the impact of molecular weight (MW) and enzyme specificity was analyzed using three different proteases (Alcalase, trypsin, and pancreatin) and varying hydrolysis times. Using preparative chromatography, hydrolysates from each enzyme treatment were fractionated into five different MW fractions (F1–F5), which were then characterized by high-performance liquid chromatography (HPLC). All SPI hydrolysates had IRI activity, resulting in a 57–29% ice crystal diameter reduction when compared to native SPI. The F1 fraction (of 4–14 kDa) was most effective among all tested hydrolysates, while the lower MW peptide fractions lacked activity. One sample (SPI-ALC 20-F1) had a 52% reduction of ice crystal size at a lower concentration of 2% compared to the typical 4% used. SFG showed a difference in H-bonding and hydrophobic interactions of the molecules on the water/air interface, which may be linked to IRI activity. This study demonstrates for the first time the ability of SPI hydrolysates to inhibit ice crystal growth and the potential application of SFG to study molecular interaction at the interface that may help illustrate the mechanism of action.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Safe Operations at Roadway Junctions: Intelligent Roadway Infrastructure as Functional Interlocking

Automated vehicle (AV) technology is quickly maturing, and the corresponding infrastructure systems that evaluate traffic and communicate to vehicles requires sophisticated sensing and perception technologies, referred to as intelligent roadway infrastructure (IRI), to complement emerging AV capabilities. IRI provides signals to vehicles, indicating right-of-way for vehicles and communicating to approaching AVs that no other vehicle is failing to yield. This capability, denoted as safety-affirmative signaling, provides a green light or a green arrow as appropriate and affirms through communication links to connected vehicles when it is safe to proceed. About 36% of collisions occur at intersections, with most occurring upon left turns (22.2%) or crossing over (12.6%), and only a small percentage (1.2%) while turning right at an intersection. Of all intersection crashes about half (52.5%) of those vehicles were traveling through a signalized intersection 2. Safety-affirmative signaling would guarantee safety of AV fleet vehicles, by providing the interlocking principle, a term from automated train control that only allows progression through a railway intersection after affirming no opportunity for a crash exists. IRI through safety-affirmative signaling would bring performance and safety to complex roadway intersections where AV transit fleet service is most needed, as well as safety benefits to traditional, non-automated vehicles and vulnerable road users. The implementation of IRI has functional, programmatic, and technical challenges. Research work performed at the National Renewable Energy Laboratory (NREL) in an integrative approach encapsulating these themes, and termed infrastructure perception and control (IPC) is motivated by improved performance (travel time), improved safety (reduced collisions), and improved energy efficiency (less fuel burned and minimized production of greenhouse gases). IPC is intended not only for roadway and intersection applications but also in extension to inform complementary buildings and grid systems to enable better co-management, as vehicles and their charging needs become increasingly integrated into the built environment. The NREL IPC project presents an open-source framework, architecture, and supporting technology to implement IRI, addressing critical issues such as fusion of data, reliability, standardization of data interfaces, and confidence of detection. The framework is informed by previous experience in U.S. Department of Defense research technology, specifically in the use of radar to detect, identify, and track aerial threats. These principles combined with multi-sensor fusion provides for a complete digital twin with known and measurable confidence and accuracy from which safety-affirmative signaling can be developed and deployed.

ADVANCED PROPULSION SYSTEMS,MATHEMATICS AND COMPUT↗

Development of a strip-shaped X-ray mapping system for 9-cell superconducting cavities

Electrons emitted via field emission during superconducting (SC) radio-frequency (RF) cavity tests at vertical test stands often collide with the iris region inside the cavity, generating X-rays at these locations. In 1.3 GHz 9-cell SC RF cavities designed for the International Linear Collider (ILC), stiffener rings located outside the iris region between cells can interfere with X-ray detection, complicating the precise identification of field emission sites. Hence, in this study, we developed a high-density strip X-ray mapping systems (sX-map) that can be inserted into the iris region of ILC-type 9-cell SC RF cavities. This sX-map facilitates efficient and accurate detection of X-rays generated near the irises, unaffected by the presence of stiffener rings. The sX-map consisted of 32 sensors per strip, with sensors spaced approximately 10 mm apart. It was deployed in every iris of the 9-cell cavity, using a total of 320 sensors. A multiplexer was employed to facilitate the readout of a large number of detectors using a minimal number of signal lines, connecting the strips inside within the vertical test cryostat. In a vertical test conducted at Jefferson Lab (JLab), we demonstrated the capability of sX-map to detect X-rays despite the presence of a stiffener ring. This paper presents the detailed design of the sX-map and the results from the vertical test at JLab.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Using an Absolute Cavity Pyrgeometer to Calibrate Pyrgeometers Outdoors with Respect to the International System of Units

Accurate measurement of the atmospheric longwave irradiance is important for renewable energy and atmospheric science applications. Pyrgeometers are deployed outdoors all over the world to measure the atmospheric longwave irradiance and presently are calibrated with traceability to the interim standards for atmospheric longwave radiation measurement, the standards are based on four pyrgeometers and their average irradiance is the World InfraRed Standard Group (WISG) which is developed and maintained by The Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC). Since 2013 the InfraRed Integrating Sphere (IRIS) developed by PMOD/WRC and the Absolute Cavity Pyrgeometer (ACP) developed by the National Renewable Energy Laboratory (NREL) have been compared outdoors six times at different locations and the difference between the measured atmospheric longwave irradiance by ACP and IRIS was less than 2 W/m2 with traceability to the International System of Units (SI). During the six comparisons the irradiance measured by the interim WISG was 5 W/m2 lower than the irradiance measured by the average irradiance measured by the ACP and IRIS [1]. Based on this discrepancy, the World Meteorological Organization's Commission for Instruments and Methods of Observation (CIMO) recommended that the interim WISG should be adjusted to be traceable to SI units [2]. In anticipation of CIMO's expert team agreement on establishing the world reference using the average irradiance measured by ACP and IRIS in this article we describe a procedure to calibrate pyrgeometers with traceability to SI. One Absolute Cavity Pyrgeometer (ACP95F3) was used to calibrate four pyrgeometers traceable to SI units. Three Eppley PIRs and one Kipp&Zonen CG4 were originally calibrated with traceability to the interim WISG. Using the described procedure below, the responsivity of each pyrgeometer was then adjusted to match the irradiance measured by ACP. Outdoor data was collected during one clear sky nights monitored by the output thermopile voltage of ACP95F3. The irradiance measured by the PIRs was calculated using NREL equation and the CG4 using NREL equation and PMOD/WRC equation. Using the NREL equation, the calculated uncertainty (U_95) of the PIRs varied from 2.43 W/m2 to 2.67 W/m2, and for the CG4 using the NREL equation U_95 equals 1.97 W/m2, and using the PMOD equation U_95 equals 2.88 W/m2 with respect to SI.

International System of Units↗

New Absolute Cavity Pyrgeometer equation by application of Kirchhoff's law and adding a convection term

An equation for the Absolute Cavity Pyrgeometer (ACP) is derived from application of Kirchhoff's law and the addition of a convection term to account for the thermopile being open to the environment, unlike a domed radiometer. The equation is then used to investigate four methods to characterise key instrumental parameters using laboratory and field measurements. The first uses solar irradiance to estimate the thermopile responsivity, the second uses a minimisation method that solves for the thermopile responsivity and transmission of the cavity, and the third and fourth revisit the Reda et al. (2012) linear least squares calibration technique. Data were collected between January and November 2020, when the ACP96 and two IRIS radiometers monitoring terrestrial irradiances were available. The results indicate good agreement with IRIS irradiances using the new equation. The analysis also indicates that while the thermopile responsivity, concentrator transmission and emissivity of an ACP can be determined independently, as an open instrument, the impact of the convection term is minor in steady-state conditions but significant when the base of the instrument is being subjected to rapid artificial cooling or heating. Using laboratory characterisation of the transmission and emissivity, together with use of an estimated solar calibration of the thermopile, generated mean differences of less than 1.5 Wm -2 to the two IRIS radiometers. A minimisation method using each IRIS radiometer as the reference also provided similar results, and the derived thermopile responsivity was within 0.3 µV W -1 m 2 of the solar-calibration-derived infrared responsivity estimate of 10.5 µV W -1 m 2 estimated using a nominal solar calibration and provide irradiances within ±2 % of the terrestrial irradiance measured by the reference pyrgeometers traceable to the International System of Units (SI). The calibration method using linear least squares regression introduced by Reda et al. (2012) that relies on rapid cooling of the ACP base but utilising the new equation was found to produce consistent results but was dependent on the assumed temperature of the air above the thermopile. This study demonstrates the potential of the ACP as another independent reference radiometer for terrestrial irradiance once the magnitude of the convection coefficient and any potential variations in it have been resolved.

47 OTHER INSTRUMENTATION↗

Handheld multi-sensor biometric imaging device and processing pipeline

A handheld biometric imaging device having an array of cameras configured to simultaneously capture face, iris and fingerprint biometrics of a subject. The device includes a plurality of visible-light cameras and a plurality of infrared-light cameras capable of being triggered simultaneously to obtain a plurality of images from which a 3D image of the light field can be constructed. The device includes a plurality of visible-light illuminators and a plurality of infrared-light illuminators that allow images of a subject to be captured under different lighting profiles. The device may include an onboard control system that is capable of reconstructing a face region, an iris region and a fingerprint region from the 3D light-field image, and then extract a corresponding face template, an iris template, and a fingerprint template from the respective reconstructed regions. The extracted face, iris, and fingerprint templates may be used for enrollment and/or comparison against a biometric-template database associated with one or more watchlists.

Bolme, David S.↗

Using an Absolute Cavity Pyrgeometer to Calibrate Pyrgeometers Outdoors with Respect to the International System of Units

Accurate measurement of the atmospheric longwave irradiance is important for renewable energy and atmospheric science applications. Pyrgeometers are deployed outdoors all over the world to measure the atmospheric longwave irradiance and presently are calibrated with traceability to the interim standards for atmospheric longwave radiation measurement, the standards are based on four pyrgeometers and their average irradiance is the World InfraRed Standard Group (WISG) which is developed and maintained by The Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC). Since 2013 the InfraRed Integrating Sphere (IRIS) developed by PMOD/WRC and the Absolute Cavity Pyrgeometer (ACP) developed by the National Renewable Energy Laboratory (NREL) have been compared outdoors six times at different locations and the difference between the measured atmospheric longwave irradiance by ACP and IRIS was less than 2 w/m2 with traceability to the International System of Units (SI). During the six comparisons the irradiance measured by the interim WISG was 5 w/m2 lower than the irradiance measured by the average irradiance measured by the ACP and IRIS [1]. Based on this discrepancy, the World Meteorological Organization's Commission for Instruments and Methods of Observation (CIMO) recommended that the interim WISG should be adjusted to be traceable to SI units [2]. In anticipation of CIMO's expert team agreement on establishing the world reference using the average irradiance measured by ACP and IRIS in this article we describe a procedure to calibrate pyrgeometers with traceability to SI. One Absolute Cavity Pyrgeometer (ACP95F3) was used to calibrate four pyrgeometers traceable to SI units. Three Eppley PIRs and one Kipp&Zonen CG4 were originally calibrated with traceability to the interim WISG. Using the described procedure below, the responsivity of each pyrgeometer was then adjusted to match the irradiance measured by ACP. Outdoor data was collected during one clear sky night monitored by the output thermopile voltage of ACP95F3. The irradiance measured by the PIRs and CG4 was calculated using NREL equation. The calculated uncertainty (U95) of the PIRs varied from 2.43 w/m2 to 2.67 w/m2 , and for the CG4 equals 1.97 w/m2 with respect to SI.

absolute cavity pyrgeometer↗

Modified split structure particle accelerators

A particle accelerator can include a first waveguide portion and a second waveguide portion. The first waveguide portion can include a first plurality of cell portions and a first iris portion that is disposed between two of the first plurality of cell portions. The first iris portion can include a first portion of an aperture such that the aperture is configured to be disposed about a beam axis. The first waveguide portion can further include a first bonding surface. The second waveguide portion can include a second plurality of cell portions and a second iris portion that is disposed between two of the second plurality of cell portions. The second iris portion can include a second portion of the aperture. The second waveguide portion can include a second bonding surface.

Agustsson, Ronald↗

Modified split structure particle accelerators

A particle accelerator can include a first waveguide portion and a second waveguide portion. The first waveguide portion can include a first plurality of cell portions and a first iris portion that is disposed between two of the first plurality of cell portions. The first iris portion can include a first portion of an aperture such that the aperture is configured to be disposed about a beam axis. The first waveguide portion can further include a first bonding surface. The second waveguide portion can include a second plurality of cell portions and a second iris portion that is disposed between two of the second plurality of cell portions. The second iris portion can include a second portion of the aperture. The second waveguide portion can include a second bonding surface.

Agustsson, Ronald↗

A Procedure to Correct the Historical Atmospheric Longwave Irradiance Data When the World Reference Is Established with Respect to the International System of Units

Historical atmospheric longwave irradiance data sets with traceability to the International System of Units (SI) are essential for renewable energy and atmospheric science research and applications. To date, all pyrgeometers used to measure the irradiance are traceable to the interim World Infrared Standard Group (WISG), not to SI units. In 2013, the Absolute Cavity Pyrgeometer (ACP) (Reda et al. 2012) was developed at the National Renewable Energy Laboratory (NREL) to measure the atmospheric longwave irradiance. The ACP has been compared against the InfraRed Integrating Sphere (IRIS), developed by the Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC) (Grobner 2012). The ACP and the IRIS are absolute instruments traceable to SI units through the International Temperature Scale of 1990. Results of six comparisons between the ACP and the IRIS at different locations have shown that the irradiance measured by WISG pyrgeometers underestimates clear-sky atmospheric longwave irradiance by 2 W/m 2 to 6 W/m 2 (Grobner et al. 2014); therefore, once the world reference is established with traceability to SI units, the WISG would be corrected, then used to calibrate field pyrgeometers with traceability to SI units. The following described method is used to correct the historical atmospheric longwave irradiance data sets in anticipation of the WISG scale change.

47 OTHER INSTRUMENTATION↗

A Procedure to Correct the Historical Atmospheric Longwave Irradiance Data When the World Reference Is Established with Respect to the International System of Units

Historical and traceable atmospheric longwave irradiance data sets with traceability to the International System of units (SI) are essential for renewable energy and atmospheric science research and applications. To date, all pyrgeometers used to measure the irradiance are traceable to the interim World InfraRed Standard Group (WISG) not to SI units. In 2013 the Absolute Cavity Pyrgeometer (ACP), [Reda et al., 2012] was developed at the National Renewable Energy Laboratory (NREL) to measure the atmospheric longwave irradiance. The ACP has been compared against the InfraRed Integrating Sphere (IRIS) developed by the Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC) [J. Grobner, 2012]. ACP and IRIS are absolute instruments traceable to SI units through the International Temperature Scale ITS-90. Results of six comparisons between ACP and IRIS at different location have shown that the irradiance measured by WISG pyrgeometers is underestimating clear-sky atmospheric longwave irradiance by 2 to 6 W/m 2 [Grobner et al., 2014]. Therefore, once the world reference is established with traceability to SI units the WISG would be corrected then used to calibrate field pyrgeometers with traceability to SI units. The described method below is used to correct the historical atmospheric longwave irradiance data sets in anticipation of the WISG scale change.

54 ENVIRONMENTAL SCIENCES↗

NREL Comparison of Absolute Cavity Pyrgeometers, InfraRed Integrating Sphere, and Pyrgeometers Traceable to World Infrared Standard Group: September 26-October 7, 2022

The comparison of the absolute cavity pyrgeometers (ACPs) with the InfraRed Integrating Sphere (IRIS), Eppley Precision Infrared Radiometer (PIR) pyrgeometers, and Kipp & Zonen (KZ) pyrgeometers traceable to the World Infrared Standard Group (WISG) was held during NREL ACP and IRIS Comparisons (NAIC) from September 26 to October 7, 2022. Data from all instruments was collected during nighttime clear sky conditions only. The irradiance measured by the ACPs is collected in 30 seconds intervals during the measurement period of two hours, and 10 seconds intervals during the calibration period of 6 minutes. During the comparison, the average (av) irradiance difference measured by ACPs and IRIS varied from -0.80 W/m2 to 0.29 W/m2 and standard deviation (sd) from 0.98 W/m2 to 1.78 W/m2. The average irradiance difference measured by ACP95F3 minus the irradiance measured by all pyrgeometers varied from 2.07 to 5.03 W/m2 with sd from 2.64 W/m2 to 2.67 W/m2.

14 SOLAR ENERGY↗

NREL Comparison of Absolute Cavity Pyrgeometers, InfraRed Integrating Sphere, and Pyrgeometers Traceable to World Infrared Standard Group: September 23-October 4, 2024

The comparison of the absolute cavity pyrgeometers (ACPs) with the CG4 FT005 pyrgeometer traceable to the InfraRed Integrating Sphere (IRIS) referred to by FT005(IRIS), Eppley Precision Infrared Radiometer (PIR) pyrgeometers, and Kipp & Zonen (KZ) pyrgeometers traceable to the World Infrared Standard Group (WISG) was held during NREL ACP and IRIS Comparisons (NAIC) from September 23 to October 4, 2024. Data from all instruments was collected during nighttime clear sky conditions only. The irradiance measured by the ACPs is collected in 30 seconds intervals during the measurement period of two hours, and 10 seconds intervals during the calibration period of 6 minutes. Two methods described in and were used for the comparison based on original Reda et. al and proposed Forgan et. al.

47 OTHER INSTRUMENTATION↗

PTEN protects kidney against acute kidney injury by alleviating apoptosis and promoting autophagy via regulating HIF1-α and mTOR through PI3K/Akt pathway

Highlights: • PTEN protects kidney against acute kidney injury. • The effect of PTEN works by alleviating apoptosis and promoting autophagy via regulating HIF1-α and mTOR by PI3K/Akt pathway. Phosphatase and tensin homolog (PTEN) deleted on human chromosome 10 is a tumor suppressor with bispecific phosphatase activity, which is often involved in the study of energy metabolism and tumorigenesis. PTEN is recently reported to participate in the process of acute injury. However, the mechanism of PTEN in Ischemia-Reperfusion Injury (IRI) has not yet been clearly elucidated. In this study, mice with bilateral renal artery ischemia-reperfusion and HK-2 cells with hypoxia/reoxygenation (H/R) were used as acute kidney injury models. We demonstrated that PTEN was downregulated in IRI-induced kidney as well as in H/R-induced HK-2 cells. By silencing and overexpressing PTEN with si-PTEN RNA and PHBLV-CMV-PTEN-flag lentivirus before H/R, we found that PTEN protected HK-2 cells against H/R-induced injury reflected by the change in cell activity and the release of LDH. Furthermore, we inhibited HIF1-α with PX-478 and inactivated mTOR with Rapamycin before the silence of PTEN in H/R model. Our data indicated that the renoprotective effect of PTEN worked via PI3K/Akt/mTOR pathway and PI3K/Akt/HIF1-α pathway, hence alleviating apoptosis and improving autophagy respectively. Our findings provide valuable insights into the molecular mechanism underlying renoprotection of PTEN on autophagy and apoptosis induced by renal IRI, which offers a novel therapeutic target for the treatment of AKI.

60 APPLIED LIFE SCIENCES↗

EGS Collab Experiment 2: Continuous Broadband Seismic Waveform Data

Two broadband seismometers were installed on the 4100 level and recorded for the duration of EGS Collab Experiment #2. Inspired by published data from similar instruments installed in the Aspo Hard Rock Lab, these long-period instruments aimed to measure the tilting of the drift in response to the injection of fluid into the testbed. One instrument was installed underneath the wellheads in Site A (aka the "battery" alcove) and the other was installed along the east wall of the drift, south of Site B. Due to the feet of gravel (ballast) laid along the floor of the drift, we were unable to anchor the sensors directly to the rock. As a result, the coupling of the sensors to the experiment rock volume is likely poor. In addition, there are a number of noise sources that complicate the interpretation of the data. For example, sensor BBB is installed adjacent (within 3 ft) to the rail line that runs towards the Ross shaft. Trains (motors) run along this line almost daily and produce a large signal in these data. Careful extraction of periods of interest, as well as filtering for specific signals, is necessary. The sensors are Nanometrics Trillium Compact Posthole seismometers, sensitive down to 120 seconds period. They were installed as close to the drift wall and as deep as we could manually excavate (only about 1 ft or so). The holes were leveled with sand and the sensors were placed on a paver before backfilling with sand. The hole was then covered by a bucket filled with insulation to improve the sensor's isolation from daily temperature variations, which are minor but present due to drift ventilation from the surface. Data were recorded on Nanometrics Centaur digitizers at 100 Hz. The full response information is available in the StationXML file provided here, or by querying the sensors through the IRIS DMC (see links below). These instruments were provided free of charge through the IRIS PASSCAL instrument center. The network code is XP and the station codes are BBA and BBB. The waveform data can be queried through the IRIS FDSN server using any method the user likes. One convenient option is to use the Obspy python package: https://docs.obspy.org/packages/obspy.clients.fdsn.html

15 GEOTHERMAL ENERGY↗

A Procedure to Correct the Historical Atmospheric Longwave Irradiance Data When the World Reference Is Established with Respect to the International System of Units

Historical atmospheric longwave irradiance data sets with traceability to the International System of Units (SI) are essential for renewable energy and atmospheric science research and applications. To date, all pyrgeometers used to measure the irradiance are traceable to the interim World Infrared Standard Group (WISG), not to SI units. In 2013, the Absolute Cavity Pyrgeometer (ACP) (Reda et al. 2012) was developed at the National Renewable Energy Laboratory (NREL) to measure the atmospheric longwave irradiance. The ACP has been compared against the InfraRed Integrating Sphere (IRIS), developed by the Physikalisch-Meteorologisches Observatorium Davos/World Radiation Center (PMOD/WRC) (Gröbner 2012). The ACP and the IRIS are absolute instruments traceable to SI units through the International Temperature Scale of 1990. Results of six comparisons between the ACP and the IRIS at different locations have shown that the irradiance measured by WISG pyrgeometers underestimates clear-sky atmospheric longwave irradiance by 2 W/m 2 to 6 W/m 2 (Gröbner et al. 2014); therefore, once the world reference is established with traceability to SI units, the WISG would be corrected, then used to calibrate field pyrgeometers with traceability to SI units. The following described method is used to correct the historical atmospheric longwave irradiance data sets in anticipation of the WISG scale change.

54 ENVIRONMENTAL SCIENCES↗

OLCF’s Advanced Computing Ecosystem (ACE): FY25 Update for Ongoing Efforts

The advent of widespread use of artificial intelligence (AI) and machine learning (ML) models in science, coupled with fast data production rates of scientific instruments strain the traditional batch-oriented high-performance computing (HPC) environment. As scientific exploration continues to require more data and faster processing and analysis, new emerging technologies and capabilities to enable cross-facility and time-sensitive workflows are required for seamless integration of HPC and experimental facilities. The Advanced Computing Ecosystem (ACE) is a strategic initiative within the Oak Ridge Leadership Computing Facility (OLCF) established in 2024 to support the development of cutting-edge technologies to advance computational research and infrastructure at OLCF and across the Department of Energy (DOE). Several DOE initiatives are spearheading the evolution of the scientific landscape by blurring facility boundaries and connecting the user facilities to advance scientific capabilities and ensure energy dominance. The DOE Integrated Research Infrastructure (IRI) program is one example that is laying a foundation to support complex cross-facility workflows. The IRI program aims to integrate diverse computational resources, data infrastructures, and scientific instruments to facilitate collaboration and accelerate scientific discovery. The Interconnected Science Ecosystem (INTERSECT) initiative at Oak Ridge National Laboratory (ORNL) is another example that aims to revolutionize scientific research through AI-driven, interconnected autonomous laboratories and research facilities. Finally, the American Science Cloud (AmSC), recently announced in the “One Big Beautiful Bill”, aims to leverage prior infrastructure efforts of the IRI and automation and AI efforts of INTERSECT (and others) to build a federated, AI-augmented AmSC platform to unify the DOE’s computing, experimental, and data resources to catalyze scientific innovation.

97 MATHEMATICS AND COMPUTING↗