Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Impact of Ligands on the Ion–Ion Selectivity of Ligand-Appended-Pillar[ n ]arene Channels

Ligand-appended pillar[5]arene (LAP) channels are emerging as a promising platform for ion-selective membranes. In this study, we investigated the ion selectivities of three LAP channels functionalized with distinct ligands: diglycolamine, carbamoylmethyl phosphine oxide, and propionamide phosphonic acid. These ligands were chosen based on their demonstrated affinities for lanthanides in solvent extraction studies. We examined the selectivity of each channel toward a series of monovalent, divalent, and trivalent ions: Li + , Na + , K + , Mg 2+ , Ca 2+ , La 3+ , Eu 3+ , and Yb 3+ . To quantify ion-channel interactions and the energetics of translocation, we computed the potential of mean force (PMF) profiles for each ion. These PMFs were subsequently recast into permeability coefficients, enabling a direct evaluation of ion permselectivity. Our results reveal distinct selectivity patterns governed by the chemical nature of the appended ligands. The diglycolamine-functionalized channel exhibits strong interactions with monovalent ions, leading to replication of the Li + bulk hydration shell within the channel. This promotes preferential transport Li + ions while effectively excluding divalent and trivalent species. In contrast, the carbamoylmethyl phosphine oxide-functionalized channel displays a reduced selectivity between monovalent ions while similarly exhibiting an effective rejection of divalent and trivalent ions. This arises from steric hindrance around channel-lining oxygens imposed by the ligand's bulky phenyl groups which limits heavy ion coordination and promotes retention of hydration shells effectively increasing effective ion size. The propionamide phosphonic acid-functionalized channel exhibits a different trend, favoring ions with lower hydration free energies, with K + ions showing enhanced permeation. These findings highlight the critical role of ligand-ion interactions in modulating ion selectivity within LAP channels. In particular, the strong coordination exhibited by diglycolamine and propionamide phosphonic acid ligands significantly influences the ion transport energetics and selectivity profiles.

hydration↗

In-Situ FTIR Detection of Transition Metal (TM)-Ion Dissolution From Cathodes in Li-Ion Batteries

Transition metal (TM) ions, commonly Ni and Mn, play a crucial role in Li-ion battery cathodes as the reaction centers for rapid redox reactions. A major challenge with TM-based cathodes is capacity degradation, particularly at higher operating voltages. This degradation is closely linked to the dissolution of TMs from the cathode materials and their subsequent deposition on the anode. This process not only modifies the surface structure of the cathode but, more significantly, alters the SEI composition on the anode [1-2]. The dissolution of TMs cations into a liquid electrolyte from cathode materials, such as Mn-ion dissolution from Mn-rich cathode (LMR), is detrimental to the cycling performance of Li-ion batteries [3-4]. Much attention has been paid to this issue but there remains a lack of characterization techniques which can detect the TM-ion dissolution from the cathode during electrochemical measurements. In our study, we use in-situ ATR-FTIR as an effective technique to probe the TM-ion dissolution from the cathode. We have first demonstrated the detrimental effects of TM ions on the electrochemical performance of Li-ion batteries by adding a small amount of TM salt (50 mM Mn(PF6)) to the electrolyte of a Li-ion coin cell with LFP and graphite electrode. We observed a rapid capacity fade after the first delithiation cycle. To investigate TM ion dissolution, we established a baseline IR spectrum for various TM solvation states (such as Mn and Ni) by measuring concentration-dependent IR spectra. This baseline spectrum helps us detect TM ion dissolution during battery cycling. In this work, we discuss in detail the effect of TM ions on the electrochemical performance of Li-ion batteries and the detection of TM ions during battery cycling using in-situ FTIR spectroscopy. We will compare TM dissolution between coated and uncoated cathodes to examine the effect of cathode coatings to mitigate degradation due to TM dissolution and cross-over from cathode to anode. References: (1) Zhan, C.; Wu, T.; Lu, J.; Amine, K. Dissolution, migration, anddeposition of transition metal ions in Li-ion batteries exemplified byMn-based cathodes - a critical review. Energy Environ. Sci. 2018, 11,243-257. (2) Jung, R.; Linsenmann, F.; Thomas, R.; Wandt, J.; Solchenbach,S.; Maglia, F.; Stinner, C.; Tromp, M.; Gasteiger, H. A. Nickel,Manganese, and Cobalt Dissolution from Ni-Rich NMC and TheirEffects on NMC622-Graphite Cells. J. Electrochem. Soc. 2019, 166,A378-A389. (3) Zhao, L.; Chenard, E.; Capraz, O. O.; Sottos, N. R.; White, S.R. Direct Detection of Manganese Ions in Organic Electrolyte by UV-Vis Spectroscopy. J. Electrochem. Soc. 2018, 165, A345-A348 (4) Zhang, Y.; Hu, A.; Xia, D.; Hwang, S.; Sainio, S.; Nordlund, D.;Michel, F. M.; Moore, R. B.; Li, L.; Lin, F. Operando characterization and regulation of metal dissolution and redeposition dynamics nearbattery electrode surface. Nat. Nanotechnol. 2023, 18, 790.

25 ENERGY STORAGE↗

Evaluating Ion Accumulation and Storage in Traveling Wave Based Structures for Lossless Ion Manipulations

Structures for lossless ion manipulations (SLIM) technology has demonstrated high resolving power ion mobility separation and flexibility to integrate complex ion manipulations into a single experimental platform. To enable IMS separations, trapping/accumulating ions inside SLIM (or in-SLIM) prior to injection of a packet for separations provides ease of operation and reduces the need for dedicated ion traps external to SLIM. To fully characterize the ion accumulation process, we have evaluated the effect of TW amplitudes, ion collection times, and storage times on the “in-SLIM” accumulation process. The study utilized a SLIM module comprising 5 distinct tracks, each with a specific ion accumulation configuration. The effect of the TW conditions on the accumulation process was investigated for a 3-peptide mixture: kemptide, angiotensin II, and neurotensin at a TW speed of 106 m/s. The effect of ion accumulation time/collection time and storage time was investigated, in addition to TW amplitude. Overall, the signal of the analyte ions increased when the ion collection time increased from 49 to 163 ms but decreased when the ion collection time increased further to 652 ms due to the space charge effects. Ion losses were observed at high TW amplitudes (e.g., 15 V p–p and 20 V p–p ). In addition, under space charge conditions (e.g., collection times of 163 and 652 ms), the signal of the analyte ions decreased with an increase in storage times for all TW amplitudes applied to the trapping region. For ion accumulation, the data indicate that gentler TW conditions must be utilized to minimize ion losses and fragments to benefit from the “in-SLIM” accumulation process. Finally, wider SLIM tracks provided better performance than those with narrower tracks.

59 BASIC BIOLOGICAL SCIENCES↗

Data for Selected Ion Monitoring for Orbitrap-Based Metabolomics

Orbitrap mass spectrometry in full scan mode enables the simultaneous detection of hundreds of metabolites and their isotope-labeled forms. Yet, sensitivity remains limiting for many metabolites, including low-concentration species, poor ionizers, and low-fractional-abundance isotope-labeled forms in isotope-tracing studies. Here, we explore selected ion monitoring (SIM) as a means of sensitivity enhancement. The analytes of interest are enriched in the orbitrap analyzer by using the quadrupole as a mass filter to select particular ions. In tissue extracts, SIM significantly enhances the detection of ions of low intensity, as indicated by improved signal-to-noise (S/N) ratios and measurement precision. In addition, SIM improves the accuracy of isotope-ratio measurements. SIM, however, must be deployed with care, as excessive accumulation in the orbitrap of similar m/z ions can lead, via space-charge effects, to decreased performance (signal loss, mass shift, and ion coalescence). Ion accumulation can be controlled by adjusting settings including injection time and target ion quantity. Overall, we suggest using a full scan to ensure broad metabolic coverage, in tandem with SIM, for the accurate quantitation of targeted low-intensity ions, and provide methods deploying this approach to enhance metabolome coverage.f

Mass Spectrometry↗

Improving the Total Impulse Capability of the NSTAR Ion Thruster With Thick-Accelerator-Grid Ion Optics

The results of performance tests with thick-accelerator-grid (TAG) ion optics are presented. TAG ion optics utilize a 50 percent thicker accelerator grid to double ion optics' service life. NSTAR ion optics were also tested to provide a baseline performance for comparison. Impingement-limited total voltages for the TAG ion optics were only 0 to 15 V higher than those of the NSTAR ion optics. Electron backstreaming limits for the TAG ion optics were 3 to 9 V higher than those for the NSTAR optics due to the increased accelerator grid thickness for the TAG ion optics. Screen grid ion transparencies for the TAG ion optics were only about 2 percent lower than those for the NSTAR optics, reflecting the lower physical screen grid open area fraction of the TAG ion optics. Accelerator currents for the TAG ion optics were 19 to 43 percent greater than those for the NSTAR ion optics due, in part, to a sudden increase in accelerator current during TAG ion optics' performance tests for unknown reasons and to the lower-than-nominal accelerator aperture diameters. Beam divergence half-angles that enclosed 95 percent of the total beam current and beam divergence thrust correction factors for the TAG ion optics were within 2 degrees and 1 percent, respectively, of those for the NSTAR ion optics.

Soulas, George C.↗

Forward silicon vertex/tracking detector design and R$\&$D for the future Electron-Ion Collider

The proposed high-luminosity high-energy Electron-Ion Collider (EIC) will provide a clean environment to precisely study several fundamental questions in the fields of high-energy and nuclear physics . A low material budget and high granularity silicon vertex/tracking detector is critical to carry out a series of hadron and jet measurements at the future EIC especially for the heavy flavor product reconstruction or tagging. The conceptual design of a proposed forward silicon tracking detector with the pseudorapidity coverage from 1.2 to 3.5 has been developed in integration with different magnet options and the other EIC detector sub-systems. The tracking performance of this detector enables precise heavy flavor hadron and jet measurements in the hadron beam going direction. The detector R&D for the proposed silicon technology candidates: Low Gain Avalanche Diode (LGAD) and radiation hard depleted Monolithic Active Pixel Sensor (MALTA), which can provide good spatial and timing resolutions, is underway. Bench test results of the LGAD and MALTA prototype sensors will be discussed.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

A compact dication source for Ba 2+ tagging and heavy metal ion sensor development

Here, we present a tunable metal ion beam that delivers controllable ion currents in the picoamp range for testing of dry-phase ion sensors. Ion beams are formed by sequential atomic evaporation and single or multiple electron impact ionization, followed by acceleration into a sensing region. Controllability of the ionic charge state is achieved through tuning of electrode potentials that influence the retention time in the ionization region. Barium, lead, and cadmium samples have been used to test the system, with ion currents identified and quantified using a quadrupole mass analyzer. Realization of a clean Ba 2+ ion beam within a bench-top system represents an important technical advance toward the development and characterization of barium tagging systems for neutrinoless double beta decay searches in xenon gas. This system also provides a testbed for investigation of novel ion sensing methodologies for environmental assay applications, with dication beams of Pb 2+ and Cd 2+ also demonstrated for this purpose.

47 OTHER INSTRUMENTATION↗

Simulations of ion heating due to ion-acoustic instabilities in presheaths

Particle-in-cell, direct simulation Monte Carlo simulations reveal that ion-acoustic instabilities excited in presheaths can cause significant ion heating. Ion-acoustic instabilities are excited by the ion flow toward a sheath when the neutral gas pressure is small enough and the electron temperature is large enough. A series of 1D simulations were conducted in which neutral plasma (electrons and ions) was uniformly sourced with an ion temperature of 0.026 eV and different electron temperatures (0.1 eV–50 eV). Ion heating was observed when the electron-to-ion temperature ratio exceeded the minimum value predicted by linear response theory to excite ion-acoustic instabilities at the sheath edge (T e /T i ≈ 28). When this threshold was exceeded, the temperature equilibration rate between ions and electrons rapidly increased near the sheath so that the local temperature ratio did not significantly exceed the threshold for instability. This resulted in significant ion heating near the sheath edge, which also extended back into the bulk plasma; presumably due to wave reflection from the sheath. Furthermore, this ion-acoustic wave heating mechanism was found to decrease for higher neutral pressures, where ion-neutral collisions damp the ion-acoustic waves and ion heating is instead dominated by inelastic collisions in the presheath.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Performance Evaluation of 40 cm Ion Optics for the NEXT Ion Engine

The results of performance tests with two 40 cm ion optics sets are presented and compared to those of 30 cm ion optics with similar aperture geometries. The 40 cm ion optics utilized both NSTAR and TAG (Thick-Accelerator-Grid) aperture geometries. All 40 cm ion optics tests were conducted on a NEXT (NASA's Evolutionary Xenon Thruster) laboratory model ion engine. Ion optics performance tests were conducted over a beam current range of 1.20 to 3.52 A and an engine input power range of 1.1 to 6.9 kW. Measured ion optics' performance parameters included near-field radial beam current density profiles, impingement-limited total voltages, electron backstreaming limits, screen grid ion transparencies, beam divergence angles, and start-up transients. Impingement-limited total voltages for 40 cm ion optics with the NSTAR aperture geometry were 60 to 90 V lower than those with the TAG aperture geometry. This difference was speculated to be due to an incomplete burn-in of the TAG ion optics. Electron backstreaming limits for the 40 cm ion optics with the TAG aperture geometry were 8 to 19 V higher than those with the NSTAR aperture geometry due to the thicker accelerator grid of the TAG geometry. Because the NEXT ion engine provided beam flatness parameters that were 40 to 63 percent higher than those of the NSTAR ion engine, the 40 cm ion optics outperformed the 30 cm ion optics.

Soulas, George C.↗

Quantitative Measurement of Positive and Negative Ion Species Ejected from a Li–O–H Surface by Hydrogen and Noble Gas Ion Irradiation

We report sputtering yields of Li + , H - , O - , and OH x - ion species from an Li–O–H surface for H, D, He, Ne, and Ar ion irradiation at 45° incidence in the energy range of 30–2000 eV. A Li film was deposited on a stainless steel target using Li evaporators in the LTX-β vessel, using the LTX-β Sample Exposure Probe (SEP), which includes an ultrahigh vacuum suitcase for transferring targets without significant contamination from air exposure. The SEP was used to transfer the Li-coated target from LTX-β to a separate Sample Exposure Station (SES) to perform ion exposure measurements. The SEP was also used for characterization of the Li-coated target utilizing X-ray photoelectron spectroscopy in a different chamber, showing that the lithium film surface was oxidized. Ion exposures were performed using an electron cyclotron resonance plasma source in the SES. Sputtered/ejected species were sampled by a quadrupole mass spectrometer with capabilities for detecting positive and negative ions, and an energy filter for determining the mean kinetic energy of the ejected ion species. All ion irradiations caused Li + ions to be ejected, while causing impurity ions such as H + , H - , O - and OH - to be ejected. Measured ion energies of Li + ions from a Li–O–H surface suggested that the typical sheath potential on the divertor surface can trap sputtered Li + ions, which were previously reported as ~ 60% of total sputtered Li species from Li targets (Allain and Ruzic in Nucl Fusion 42:202, 2002). Hence, our results for the sputtering yields of ejected ion species and their associated ion energies from a Li–O–H surface indicates that lithium sputtering is suppressed and impurity removal is enhanced due to the sheath potential at the divertor surface for fusion reactor applications.

Plasma-material interaction↗

Charging and ion ejection dynamics of large helium nanodroplets exposed to intense femtosecond soft xray pulses

Ion ejection from charged helium nanodroplets exposed to intense femtosecond soft X-ray pulses is studied by single-pulse ion time-of-flight (TOF) spectroscopy in coincidence with small-angle X-ray scattering. Scattering images encode the droplet size and absolute photon flux incident on each droplet, while ion TOF spectra are used to determine the maximum ion kinetic energy, Ekin, of He+ j fragments (j = 1-4). Measurements span HeN droplet sizes between N similar to 10(7) and similar to 10(10) (radii R-0 = 78-578 nm), and droplet charges between similar to 9x10(-5) and similar to 3x10(-3) e/atom. Conditions encompass a wide range of ionization and expansion regimes, from departure of all photoelectrons from the droplet, leading to pure Coulomb explosion, to substantial electron trapping by the electrostatic potential of the charged droplet, indicating the onset of hydrodynamic expansion. The unique combination of absolute Xray intensities, droplet sizes, and ion Ekin on an event-by-event basis reveals a detailed picture of the correlations between the ionization conditions and the ejection dynamics of the ionic fragments. The maximum E-kin of He+ is found to be governed by Coulomb repulsion from unscreened cations across all expansion regimes. The impact of ion-atom interactions resulting from the relatively low charge densities is increasingly relevant with less electron trapping. The findings are consistent with the emergence of a charged spherical shell around a quasineutral plasma core as the degree of ionization increases. The results demonstrate a complex relationship between measured ion E-kin and droplet ionization conditions that can only be disentangled through the use of coincident single-pulse TOF and scattering data.

Helium↗

Molecular dynamics simulations of alkaline earth metal ions binding to DNA reveal ion size and hydration effects

The identity of metal ions surrounding DNA is key to its biological function and materials applications. In this work, we compare atomistic molecular dynamics simulations of double strand DNA (dsDNA) with four alkaline earth metal ions (Mg 2+ , Ca 2+ , Sr 2+ , and Ba 2+ ) to elucidate the physical interactions that govern DNA–ion binding. Simulations accurately model the ion–phosphate distance of Mg 2+ and reproduce ion counting experiments for Ca 2+ , Sr 2+ , and Ba 2+ . Our analysis shows that alkaline earth metal ions prefer to bind at the phosphate backbone compared to the major groove and negligible binding occurs in the minor groove. Larger alkaline earth metal ions with variable first solvation shells (Ca 2+ , Sr 2+ , and Ba 2+ ) show both direct and indirect binding, where indirect binding increases with ion size. Mg 2+ does not fit this trend because the strength of its first solvation shell predicts indirect binding only. Ions bound to the phosphate backbone form fewer contacts per ion compared to the major groove. Within the major groove, metal ions preferentially bind to guanine–cystosine base pairs and form simultaneous contacts with the N7 and O6 atoms of guanine. Overall, we find that the interplay among ion size, DNA–ion interaction, and the size and flexibility of the first solvation shell are key to predicting how alkaline earth metal ions interact with DNA.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Concentration-dependent ion correlations impact the electrochemical behavior of calcium battery electrolytes.

Ion interactions strongly determine the solvation environments of multivalent electrolytes even at concentrations below that required for practical battery-based energy storage. This statement is particularly true of electrolytes utilizing ethereal solvents due to their low dielectric constants. These solvents are among the most commonly used for multivalent batteries based on reactive metals (Mg, Ca) due to their reductive stability. Recent developments in multivalent electrolyte design have produced a variety of new salts for Mg2+ and Ca2+ that test the limits of weak coordination strength and oxidative stability. Such electrolytes have great potential for enabling full-cell cycling of batteries based on these working ions. However, the ion interactions in these electrolytes exhibit significant and non-intuitive concentration relationships. In this work, we investigate a promising exemplar, calcium tetrakis(hexafluoroisopropoxy)borate (Ca(BHFIP)(2)), in the ethereal solvents 1,2-dimethoxyethane (DME) and tetrahydrofuran (THF) across a concentration range of several orders of magnitude. Surprisingly, we find that effective salt dissociation is lower at relatively dilute concentrations (e.g. 0.01 M) than at higher concentrations (e.g. 0.2 M). Combined experimental and computational dielectric and X-ray spectroscopic analyses of the changes occurring in the Ca2+ solvation environment across these concentration regimes reveals a progressive transition from well-defined solvent-separated ion pairs to de-correlated free ions. This transition in ion correlation results in improvements in both conductivity and calcium cycling stability with increased salt concentration. Comparison with previous findings involving more strongly associating salts highlights the generality of this phenomenon, leading to important insight into controlling ion interactions in ether-based multivalent battery electrolytes.

Hahn, Nathan T.↗

High Ion Conductive and Selective Membrane Achieved through Dual Ion Conducting Mechanisms

Conventional ion-selective membranes, that is ion-exchange and porous membranes, are unable to perform high conductivity and selectivity simultaneously due to the contradictions between their ion selecting and conducting mechanisms. Here, in this work, a bifunctional ion-selective layer is developed via the combination of nanoporous boron nitride (PBN) and ion exchange groups from Nafion to achieve high ion conductivity through dual ion conducting mechanisms as well as high ion selectivity. A template-free method is adopted to synthesize flake-like PBN, which is further enmeshed with Nafion resin to form the bifunctional layer coated onto a porous polyetherimide membrane. The double-layer membrane exhibits excellent ion selectivity (1.49 × 10 8 mS cm –3 min), which is 22 times greater than that of the pristine porous polyetherimide membrane, with outstanding ion conductivity (64 mS cm –1 ). In a vanadium flow battery, the double-layer membrane achieves a high Coulombic efficiency of 97% and outstanding energy efficiency of 91% at 40 mA cm –2 with a stable cycling performance for over 700 cycles at 100 mA cm –2 . PBN with ion exchange groups may therefore offer a potential solution to the limitation between ion selectivity and conductivity in ion-selective membranes.

36 MATERIALS SCIENCE↗

Extended Donnan-Manning theory for selective ion partition and transport in ion exchange membrane

The use of ion exchange membranes (IEMs) for electrochemical ion-ion separation leverages the selectivity of the IEMs toward like-charged species via valence difference and/or other ion membrane interactions. A mechanistic model that relates selectivity with membrane structural and chemical properties is lacking in the literature. Here, in this study, we extend the Manning’s counter-ion condensation model for describing ion partition and ion mobility inside IEMs to mixed salts scenarios. We evaluate the extended Donnan-Manning model against experimental data from literature and compare the performance the Donnan-Manning model to that of the ideal Donnan model and the Donnan-Affinity model. Our analysis shows that, despite its structural complexity, the Donnan-Manning model has less fitting parameters than the Donnan-Affinity model and generally outperforms the two other models in predicting counter-ion and co-ion partition. With the assumption of a higher mobility of condensed ions than that of uncondensed ions, the generalized Manning’s model can also predict counter-ion mobility selectivity for cation exchange membranes, but its performance for predicting mobility selectivity for anion exchange membranes is still unsatisfactory.

42 ENGINEERING↗

The effect of ion pairing on speciation and transport in ion exchange membranes at varying hydration levels: A four-state model

Understanding ion pairing in ion exchange membranes (IEMs) is essential for advancing IEM applications in energy and environmental technologies. Here, this study introduces a four-state molecular dynamics model to quantify speciation and transport within Nafion-117, specifically examining the role of ion pairing in monovalent and divalent counterions (NaCl, Na 2 SO 4 , and MgSO 4 ). By analyzing radial distribution functions (RDFs) and molecular snapshots, we distinguish ion pairing modes and classify counterions into four states: condensed counterion, condensed ion pair, free ion pair, and free counterion. A key finding is that while divalent counterions (e. g., Mg 2+ ) maintain stable speciation across hydration levels, monovalent counterions (e.g., Na + ) show notable speciation shifts with hydration. Both monovalent and divalent counterions are not diffusive when condensed onto the polymer (sorbed to membrane functional groups). In contrast, free counterions are diffusive across all hydration levels. To evaluate the overall diffusivity of counterions, four-state fractions and diffusivities are computed, each contributing to counterion transport. The condensed/free ion speciation for multivalent sulfate salts aligns with previous revisions to the Donnan-Manning framework that include ion pairing, thereby validating its relevance to established membrane theories. The four-state model's diffusivity results support several current ion exchange assumptions, including that the condensed counterions are immobile, while uncondensed counterions are mobile. The four-state model offers insights into contact ion pairing within IEMs, highlighting its potential even when undetected in aqueous solution experiments. This work advances the theoretical understanding of counterion speciation in IEMs while identifying model limitations that suggest avenues for refinement, such as distinguishing water-mediated ion pairs between fully hydrated ions.

Ion exchange membranes↗