Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IONIZATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Aqueous Electrolyte Ionization over Extreme Ranges as Simple Fundamental Relation with Density and Believed Universal; Sodium Chloride Ionization for 0o to 1000oC and to 1000 MPa (10000 Atm.).

The chemical nature of aqueous electrolyte ionization is illustrated by a simple relationship with water as a reactant believed to correlate ionization of aqueous sodium chloride approaching infinite dilution over the entire range of temperature and pressure [0 to 1000oC; 0.1 to 1000 MPa (10000 Atm)]. The derived equation accurately and smoothly describes the ionization constant of sodium chloride [K(NaCl)] in both water and water strongly diluted by inert solvent. Effects of water density on ionization are quantitatively and simply described that oppose conventional theory that ionization is a function only of dielectric constant, and theorists should apply this simplicity with density in understanding aqueous electrolyte ionization. There appears to be no substantive evidence for Pitzer's earlier proposal (1983) that K(NaCl) with decreasing very low densities (if known) would diverge sharply downward by several orders of magnitude. Classical ionization theories are limited in universal application, and it seems that theory must adjust to this observed simple fundamental relationship.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AN EXPERIMENTAL AND THEORETICAL STUDY ON THE IONIZATION ENERGIES OF POLYYNES (H-(C{identical_to}C) {sub n} -H; n = 1-9)

We present a combined experimental and theoretical work on the ionization energies of polyacetylene-organic molecules considered as important building blocks to form polycyclic aromatic hydrocarbons in protoplanetary nebulae such as CRL 618. This set of astrophysical data can be utilized with significant confidence in future astrochemical models of photon-dominated regions and also of the protoplanetary nebulae CRL 618. We recommend ionization energies of polyacetylenes from diacetylene up to heptaacetylene with an experimental accuracy of {+-}0.05 eV: 10.03 eV (diacetylene), 9.45 eV (triacetylene), 9.08 eV (tetraacetylene), 8.75 eV (pentaacetylene), 8.65 eV (hexaacetylene), and 8.50 eV (heptaacetylene). Further, ionization energies with an accuracy of {+-}0.1 eV: 8.32 eV (octaacetylene) and 8.24 eV (nonaacetylene), were computed. Implications of these energies to the redox chemistry involved in the multiply charged metal-ion mediated chemistry of hydrocarbon-rich atmospheres of planets and their moons such as Titan are also discussed.

79 ASTRONOMY AND ASTROPHYSICS↗

Ionization processes in small quasimolecules: He{sub 2}{sup 2+} (He{sup 2+}+ He)

The energy spectra of electrons ejected in He{sup 2+}-He collisions were measured in the ion energy range 6-30 keV. Theoretical analysis of the ionization mechanisms has been performed on the basis of the advanced adiabatic approximation for one-electron processes and perturbation theory for two-electron processes. The ionization channel 2p{sigma}{sup 2}{yields} 1s{sigma}nd{sigma}{yields} 1s{sigma}{epsilon}d{sigma} has been revealed, which makes a considerable contribution to the ionization cross section in the keV ion energy range.

74 ATOMIC AND MOLECULAR PHYSICS↗

Comparison of Internal Energy Distributions of Ions Created by Electrospray Ionization and Laser Ablation-Liquid Vortex Capture-Electrospray Ionization

Recently a number of techniques have combined laser ablation with liquid capture for mass spectrometry spot sampling and imaging applications. The newly developed non-contact liquid-vortex capture probe has been used to efficiently collect 355 nm UV laser ablated material in a continuous flow solvent stream in which the captured material dissolves and then undergoes electrospray ionization. This sampling and ionization approach has produced what appear to be classic electrospray ionization spectra; however, the softness of this sampling/ionization process versus simple electrospray ionization has not been definitely determined. A series of benzlypyridinium salts, known as thermometer ions, were used to compare internal energy distributions between electrospray ionization and the UV laser ablation liquid-vortex capture probe electrospray combination. Measured internal energy distributions were identical between the two techniques, even with differences in laser fluence (0.7-3.1 J cm-2) and when using UV-absorbing or non-UV-absorbing sample substrates. This data indicates ions formed directly by UV laser ablation, if any, are likely an extremely small constituent of the total ion signal observed. Instead, neutral molecules, clusters or particulates ejected from the surface during laser ablation, subsequently captured and dissolved in the flowing solvent stream then electrosprayed are the predominant source of ion signal observed. The electrospray ionization process used controls the softness of the technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Atmospheric Pressure Ionization Using a High Voltage Target Compared to Electrospray Ionization

A new atmospheric pressure ionization (API) source, viz. UniSpray, was evaluated for mass spectrometry (MS) analysis of pharmaceutical compounds by head-to-head comparison with electrospray ionization (ESI) on the same high-resolution MS system. The atmospheric pressure ionization source is composed of a grounded nebulizer spraying onto a high voltage, cylindrical stainless steel target. Molecules are ionized in a similar fashion to electrospray ionization, predominantly producing protonated or deprotonated species. Adduct formation (e.g., proton and sodium adducts) and in-source fragmentation is shown to be almost identical between the two sources. The performance of the new API source was compared with electrospray by infusion of a mix of 22 pharmaceutical compounds with a wide variety of functional groups and physico-chemical properties (molecular weight, logP, and pKa) in more than 100 different conditions (mobile phase strength, solvents, pH, and flow rate). The new API source shows an intensity gain of a factor 2.2 compared with ESI considering all conditions on all compounds tested. Finally, some hypotheses on the ionization mechanism, similarities, and differences with ESI, are discussed. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

CHILI – the Chicago Instrument for Laser Ionization – a new tool for isotope measurements in cosmochemistry

We describe CHILI, the Chicago Instrument for Laser Ionization, a new resonance ionization mass spectrometer developed for isotopic analysis at high spatial resolution and high sensitivity of small samples like contemporary interstellar dust grains returned by the Stardust spacecraft. We explain how CHILI addresses the technical challenges associated with such analyses by pushing most technical specifications towards their physical limits. As an initial demonstration, after many years of designing and developing CHILI, we have analyzed presolar silicon carbide grains for their isotopic compositions of strontium, zirconium, and barium. Subsequently, after further technical improvements, we have used CHILI to analyze, for the first time without interference, all stable isotopes of iron and nickel simultaneously in presolar silicon carbide grains. With a special timing scheme for the ionization lasers, we separated iron and nickel isotopes in the time-of-flight spectrum such that the isobaric interference between Fe-58 and Ni-58 was resolved. In-depth discussion of the astrophysical implications of the presolar grain results is deferred to dedicated later publications. Here we focus on the technical aspects of CHILI, its status quo, and further developments necessary to achieve CHILI's ultimate goals, similar to 10 nm lateral resolution and 30-40% useful yield.

Stephan, Thomas (ORCID:0000000163778731)↗

Ion energies in high power impulse magnetron sputtering with and without localized ionization zones

High speed imaging of high power impulse magnetron sputtering discharges has revealed that ionization is localized in moving ionization zones but localization disappears at high currents for high yield targets. This offers an opportunity to study the effect ionization zones have on ion energies. We measure that ions have generally higher energies when ionization zones are present, supporting the concept that these zones are associated with moving potential humps. We propose that the disappearance of ionization zones is caused by an increased supply of atoms from the target which cools electrons and reduces depletion of atoms to be ionized.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Neutron-impact ionization of He

The time-dependent close-coupling method is used to calculate neutron-impact single and double ionization cross sections of the He atom. Here, we also present the ratio of double to single ionization for He as a guide to experimental checks of theory at low energies and experimental confirmation of the rapid rise of the ratio at high energies unique to neutron-impact ionization of atoms.

74 ATOMIC AND MOLECULAR PHYSICS↗

On the SIMS Ionization Probability of Organic Molecules

The prospect of improved secondary ion yields for secondary ion mass spectrometry (SIMS) experiments drives innovation of new primary ion sources, instrumentation, and post-ionization techniques. The largest factor affecting secondary ion efficiency is believed to be the poor ionization probability (α{sup +}) of sputtered material, a value rarely measured directly, but estimated to be in some cases as low as 10{sup −5}. Our lab has developed a method for the direct determination of α{sup +} in a SIMS experiment using laser post-ionization (LPI) to detect neutral molecular species in the sputtered plume for an organic compound. Here, we apply this method to coronene (C{sub 24}H{sub 12}), a polyaromatic hydrocarbon that exhibits strong molecular signal during gas-phase photoionization. A two-dimensional spatial distribution of sputtered neutral molecules is measured and presented. It is shown that the ionization probability of molecular coronene desorbed from a clean film under bombardment with 40 keV C{sub 60} cluster projectiles is of the order of 10{sup −3}, with some remaining uncertainty arising from laser-induced fragmentation and possible differences in the emission velocity distributions of neutral and ionized molecules. In general, this work establishes a method to estimate the ionization efficiency of molecular species sputtered during a single bombardment event. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Competitive ionization processes of anthracene excited with a femtosecond pulse in the multi-photon ionization regime

To clarify the ionization mechanism of large molecules under multi-photon ionization conditions, photo-electron spectroscopic studies on anthracene have been performed with electron imaging technique. Electron kinetic energy distributions below a few eV reveal that three kinds of ionization channels coexist, viz., vertical ionization, ionization from Rydberg states, and thermionic hot electron emission. Their relative yield is determined by the characteristic of the laser pulse. The duration in particular influences the ratio between the first two processes, while for higher intensities the last process dominates. Our results provide strong evidence that internal conversion plays an important role for the ionization of the molecule.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

STORAGE RING CROSS-SECTION MEASUREMENTS FOR ELECTRON IMPACT SINGLE AND DOUBLE IONIZATION OF Fe{sup 9+} AND SINGLE IONIZATION OF Fe{sup 10+}

We have measured electron impact ionization from the ground state of Fe{sup 9+} and Fe{sup 10+} over the relative electron-ion collision energy ranges 200-1900 eV and 250-1800 eV, respectively. The ions were confined in an ion storage ring long enough for essentially all metastable levels to radiatively relax to the ground state. For single ionization, we find a number of discrepancies between the existing theoretical cross sections and our results. The calculations appear to neglect some excitation-autoionization (EA) channels, particularly from n = 3 to n' excitations, which are important near threshold, and those from n = 2 {yields} 3 excitations, which contribute at about 650 eV. Conversely, at higher energies the calculations appear to overestimate the importance of EA channels due to excitation into levels where n {>=} 4. The resulting experimental rate coefficients agree with the most recent theory for Fe{sup 9+} to within 16% and for Fe{sup 10+} to within 19% at temperatures where these ions are predicted to form in collisional ionization equilibrium. We have also measured double ionization of Fe{sup 9+} forming Fe{sup 11+} in the energy range 450-3000 eV and found that although there is an appreciable cross section for direct double ionization, the dominant mechanism appears to be through direct ionization of an inner shell electron producing an excited state that subsequently stabilizes through autoionization.

74 ATOMIC AND MOLECULAR PHYSICS↗

The MICE Muon Beam on ISIS and the beam-line instrumentation of the Muon Ionization Cooling Experiment

The international Muon Ionization Cooling Experiment (MICE), which is under construction at the Rutherford Appleton Laboratory (RAL), will demonstrate the principle of ionization cooling as a technique for the reduction of the phase-space volume occupied by a muon beam. Ionization cooling channels are required for the Neutrino Factory and the Muon Collider. MICE will evaluate in detail the performance of a single lattice cell of the Feasibility Study 2 cooling channel. The MICE Muon Beam has been constructed at the ISIS synchrotron at RAL, and in MICE Step I, it has been characterized using the MICE beam-instrumentation system. In this paper, the MICE Muon Beam and beam-line instrumentation are described. The muon rate is presented as a function of the beam loss generated by the MICE target dipping into the ISIS proton beam. For a 1 V signal from the ISIS beam-loss monitors downstream of our target we obtain a 30 KHz instantaneous muon rate, with a neglible pion contamination in the beam.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Vibrational Spectroscopy for the Determination of Ionizable Group Content in Ionomer Materials

An approach based on vibrational spectral measurements is described for determining the ionizable group content of ion conducting polymer membrane materials. Aimed at supporting the assessment of membrane stability and wear characteristics, performance is evaluated for attenuated total reflection Fourier transform infrared (ATR FT-IR) spectroscopy, confocal Raman microscopy, and ATR FT-IR microscopy using perfluorinated ionomer membrane standards. One set of ionomer standards contained a sulfonic acid ionizable group and the other a sulfonyl imide group. The average number of backbone tetrafluoroethylene (TFE) units separating the ionizable-group containing side chains was in the range of 7.2–2.1 (sulfonic acid set) and 10.5–4.6 (sulfonyl imide set). A poly(tetrafluoroethylene) (PTFE) sample was included as a blank, representing the limit of zero ionizable group (and maximum TFE) content. Calibration relationships were derived from area-normalized vibrational spectra. For all three methods, calibration models applied to independent spectral measurements of samples predicted the ratio of backbone TFE groups to ionizable groups in the repeat unit ( m) with a standard error of ≤ ±0.3. The confocal Raman and ATR FT-IR microscopy techniques achieved ideal blank responses and the lowest prediction errors, down to m ± 0.1 at the 90% confidence level. With its relative simplicity, low sample size requirements, and potential for quantitative micron-scale spatial mapping of the ionizable group content within a membrane, the approach has application to advancing materials development, including exploratory synthesis, durability and wear assessment, and in situ studies of membrane process.

Korzeniewski, Carol↗

Air resonance enhanced multiphoton ionization tagging velocimetry

Air resonance enhanced multiphoton ionization (REMPI) tagging velocimetry (ART) was demonstrated in quiescent and supersonic flows. The ART velocimetry method utilizes a wavelength tunable laser beam to resonantly ionize molecular oxygen in air and generate additional avalanche-type ionization of molecular nitrogen. The fluorescence emissions from the first negative and first positive bands of molecular nitrogen are, thus, produced and used for flow tagging. Detailed characterization of ART was conducted, including the effects of oxygen resonance to fluoresce nitrogen, nitrogen fluorescence spectrum, laser energy deposition into quiescent flow showing minimal perturbations in flow, fluorescence lifetime study at various pressures, and line tagging without breakdown. Pointwise velocity measurements within a supersonic flow from a nominal Mach 1.5 nozzle have been conducted and characterized.

Clark, Aleksander↗

Laser Resonance Ionization Spectroscopy of the Lanthanides Tb, Dy and Ho as Homologues to Actinides and Super Heavy Elements

Spectroscopic investigations of the rare earth elements Tb, Dy and Ho have been carried out using laser resonance ionization mass spectroscopy. A variety of new intermediate energy levels and autoionizing states were observed in these elements. Efficient and selective excitation and ionization schemes for the elements have been developed for Ti:Sapphire lasers using the spectroscopic data. Resonant ionization schemes for Np were also been studied as the preparation work for related investigations on actinide elements and for the spectroscopy on the heaviest elements, where spectroscopic data so far are scarce or not existing at all.

74 ATOMIC AND MOLECULAR PHYSICS↗