Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ION DETECTION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

High-Fidelity Ion State Detection Using Trap-Integrated Avalanche Photodiodes

Integrated technologies greatly enhance the prospects for practical quantum information processing and sensing devices based on trapped ions. High-speed and high-fidelity ion state readout is critical for any such application. Integrated detectors offer significant advantages for system portability and can also greatly facilitate parallel operations if a separate detector can be incorporated at each ion-trapping location. Here, we demonstrate ion quantum state detection at room temperature utilizing single-photon avalanche diodes (SPADs) integrated directly into the substrate of silicon ion trapping chips. Furthermore, we detect the state of a trapped Sr + ion via fluorescence collection with the SPAD, achieving 99.92(1)% average fidelity in 450 μs, opening the door to the application of integrated state detection to quantum computing and sensing utilizing arrays of trapped ions.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ionizing particle detection based on phononic crystals

Most conventional radiation detectors are based on electronic or photon collections. In this work, we introduce a new and novel type of ionizing particle detector based on phonon collection. Helium ion radiation treats tumors with better precision. There are nine known isotopes of helium, but only helium-3 and helium-4 are stable. Helium-4 is formed in fusion reactor technology and in enormous quantities during Big Bang nucleo-synthesis. In this study, we introduce a technique for helium-4 ion detection (sensing) based on the innovative properties of the new composite materials known as phononic crystals (PnCs). PnCs can provide an easy and cheap technique for ion detection compared with conventional methods. PnC structures commonly consist of a periodic array of two or more materials with different elastic properties. The two materials are polymethyl-methacrylate and polyethylene polymers. The calculations showed that the energies lost to target phonons are maximized at 1 keV helium-4 ion energy. There is a correlation between the total phonon energies and the transmittance of PnC structures. The maximum transmission for phonons due to the passage of helium-4 ions was found in the case of making polyethylene as a first layer in the PnC structure. Therefore, the concept of ion detection based on PnC structure is achievable.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Ion and electron detector for use in an ICR spectrometer

A detector for detecting ions and/or electrons present in a resonance cell of an ICR spectrometer is disclosed. The detector which operates on the Q-meter principle is driven by an external rf oscillator capable of providing rf frequencies up to about 15MHz at an adjustable low rf signal level, e.g., below 20mV. The detector is connected across the resonance of the cell to detect ions by detecting their cyclotron frequency. Electrons are detectable by connecting the detector across the cell's trapping plates and thereby detect the electrons' trapping motion, the frequency of which is in the megahertz range.

Huntress, W. T.↗

Effect of Electrode Geometry on the Classification Performance of Rapid Evaporative Ionization Mass Spectrometric (REIMS) Bacterial Identification

The recently developed automated, high-throughput monopolar REIMS platform is suited for the identification of clinically important microorganisms. Although already comparable to the previously reported bipolar forceps method, optimization of the geometry of monopolar electrodes, at the heart of the system, holds the most scope for further improvements to be made. For this, sharp tip and round shaped electrodes were optimized to maximize species-level classification accuracy. Following optimization of the distance between the sample contact point and tube inlet with the sharp tip electrodes, the overall cross-validation accuracy improved from 77% to 93% in negative and from 33% to 63% in positive ion detection modes, compared with the original 4 mm distance electrode. As an alternative geometry, round tube shaped electrodes were developed. Geometry optimization of these included hole size, number, and position, which were also required to prevent plate pick-up due to vacuum formation. Additional features, namely a metal “X”-shaped insert and a pin in the middle were included to increase the contact surface with a microbial biomass to maximize aerosol production. Following optimization, cross-validation scores showed improvement in classification accuracy from 77% to 93% in negative and from 33% to 91% in positive ion detection modes. Supervised models were also built, and after the leave 20% out cross-validation, the overall classification accuracy was 98.5% in negative and 99% in positive ion detection modes. This suggests that the new generation of monopolar REIMS electrodes could provide substantially improved species level identification accuracies in both polarity detection modes. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A Pockels cell enabled heterodyne phase contrast imaging diagnostic for detection of ion cyclotron emission

This work describes a novel optical heterodyne detection scheme that significantly extends the frequency response of the phase contrast imaging method to detect electron density fluctuations in tens of megahertz frequency range. The system employs a variable frequency electro-optic modulator to allow operation at any frequency in the range 10–40 MHz without the need to realign the system. The frequency coverage of the system makes it suitable to measure the radial structure of the electron density component of ion cyclotron emission on devices having confining magnetic field of a few tesla, thus extending the purely temporal measurements provided so far by magnetic probes.

47 OTHER INSTRUMENTATION↗

Measurements of the highest acceleration gradient for ions produced with a long laser pulse

Ultrafast plasma light ion streams have been produced using the 300 ps, kJ-class iodine laser, operating at PALS Centre in Prague. Ion detection was performed through standard ion collectors (IC) in time-of-flight configuration (TOF), shielded by thin metallic absorbers. This new diagnostics technique has been theoretically studied and experimentally tested in order to cut the long photopeak contribution and to analyze the ultrafast particle signal. Processing the obtained experimental IC-TOF data, including deconvolution processes of the TOF signals, UV/soft-x-ray photopeak absorption, and ion transmission calculations for different metallic filters, is shown. Mainly amorphous carbon (graphite) targets have been irradiated in order to limit the maximum number of ion charge states and to focus our study on demonstrating the validity of the proposed investigation technique. Maximum ion energy and acceleration gradient estimations as a function of the laser energy and focal spot diameter are reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Fabrication and characterization of a co-planar detector in diamond for low energy single ion implantation

We demonstrate low energy single ion detection using a co-planar detector fabricated on a diamond substrate and characterized by ion beam induced charge collection. Histograms are taken with low fluence ion pulses illustrating quantized ion detection down to a single ion with a signal-to-noise ratio of approximately 10. We anticipate that this detection technique can serve as a basis to optimize the yield of single color centers in diamond. In conclusion, the ability to count ions into a diamond substrate is expected to reduce the uncertainty in the yield of color center formation by removing Poisson statistics from the implantation process.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Non-destructive single-pass low-noise detection of ions in a beamline

We have conceived, built, and operated a device for the non-destructive single-pass detection of charged particles in a beamline. The detector is based on the non-resonant pick-up and subsequent low-noise amplification of the image charges induced in a cylindrical electrode surrounding the particles’ beam path. The first stage of the amplification electronics is designed to be operated from room temperature down to liquid helium temperature. The device represents a non-destructive charge counter as well as a sensitive timing circuit. We present the concept and design details of the device. We have characterized its performance and show measurements with low-energy highly charged ions (such as Ar{sup 13+}) passing through one of the electrodes of a cylindrical Penning trap. This work demonstrates a novel approach of non-destructive, low noise detection of charged particles which is, depending on the bunch structure, suitable, e.g., for ion traps, low-energy beamlines or accelerator transfer sections.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Positive/negative ion velocity mapping apparatus for electron-molecule reactions

In molecular dissociative ionization by electron collisions and dissociative electron attachment to molecule, the respective positively and negatively charged fragments are the important products. A compact ion velocity mapping apparatus is developed for the angular distribution measurements of the positive or negative fragments produced in the electron-molecule reactions. This apparatus consists of a pulsed electron gun, a set of ion velocity mapping optic lenses, a two-dimensional position detector including two pieces of micro-channel plates, and a phosphor screen, and a charge-coupled-device camera for data acquisition. The positive and negative ion detections can be simply realized by changing the voltage polarity of ion optics and detector. Velocity sliced images can be directly recorded using a narrow voltage pulse applied on the rear micro-channel plate. The efficient performance of this system is evaluated by measuring the angular distribution of O{sup -} from the electron attachments to NO at 7.3 and 8.3 eV and O{sup +} from the electron collision with CO at 40.0 eV.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Ion-induced gamma-ray detection of fast ions escaping from fusion plasmas

A 12 × 12 pixel detector has been developed and used in a laboratory experiment for lost fast-ion diagnostics. With gamma rays in the MeV range originating from nuclear reactions {sup 9}Be(α, nγ){sup 12}C, {sup 9}Be(d, nγ){sup 12}C, and {sup 12}C(d, pγ){sup 13}C, a high purity germanium (HPGe) detector measured a fine-energy-resolved spectrum of gamma rays. The HPGe detector enables the survey of background-gamma rays and Doppler-shifted photo peak shapes. In the experiments, the pixel detector produces a gamma-ray image reconstructed from the energy spectrum obtained from total photon counts of irradiation passing through the detector's lead collimator. From gamma-ray image, diagnostics are able to produce an analysis of the fast ion loss onto the first wall in principle.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Unveiling Venus with VOIR

The goals and intended capabilities of the Venus Orbiting Imaging Radar (VOIR), scheduled for launch in the mid-1980's, are reviewed. Current Pioneer Venus Orbiter data is considered of unsufficient resolution for actual planetary mapping of the geologic terrain of Venus, while the VOIR possesses an SAR which is able to provide a 600 m line pair resolution. The data would yield information of small-scale roughness and the rms slope of surface features, would serve as an efficient altimeter, and help track the planet's gravity field to within 1/5000 cm/sec resolution. Estimations of wind velocity and turbulence would be made available, and a Langmuir probe, a quadrupole mass analyzer, and an ion analyzer will detect ions, electrons, elemental compositions, concentrations, and densities, as well as velocities.

James, W.↗

Pickup Ions at Dione and Enceladus

Voyager images of the icy satellites of Saturn, Dione and Enceladus, suggest they have been geologically active and are not only composed of ice. Recent observations by HST have shown the presence of ozone at both Dione and Rhea which also implies the presence of molecular oxygen at these bodies. The Cassini Plasma Spectrometer (CAPS) will provide the capability to determine the global composition of these bodies by measuring the pickup ions produced by the ionization of their sputter produced atmospheres. We will present a model of these atmospheres and associated pickup ions and demonstrate CAPS ability to distinguish the freshly produced picked up ions from the ambient plasma. Such ions are expected to form a ring distribution that will have a uniquely different energy-angle dependence than the ambient plasma ions. In the case of Dione we expect the potential for a moderate strength interaction for which both Voyager 1 and Pioneer 11 spacecraft measured ion cyclotron waves centered on the Dione L shell and near the equatorial plane. Since Enceladus may be the source of the E-ring, some surprises may be encountered during its close encounter with the Cassini spacecraft. In the case of Dione we will show that a wake pass at 500 km altitude is more than an order of magnitude better than an upstream pass at 500 km altitude. Pickup ion detection for minor ion species such as NH3+ is possible for 500 km altitude wake pass but not for a 500 km altitude upstream pass at closest approach. For navigation reasons a 100 km pass is not allowed and therefore it is essential to have a wake pass to maximize the science return for a targeted flyby with Dione. The CAPS observations when combined with magnetometer, plasma wave and energetic particle observations will allow us to estimate the source of ions into Saturn's magnetosphere due to these two bodies and to characterize the nature of the interaction with Saturn's magnetosphere.

Sittler, E.↗

On the possibility of detection of ions from Venus at 1 AU

The possibility that single ionized helium enhancements observed near 1 AU are the result of ion pickup from Venus is analyzed and found to be implausible. It is still possible, however, that Venus ions are present in the solar wind with sufficiently high fluxes to be detectable by earth-orbiting satellites near the time of inferior conjunction. Because of the inclination of the orbit of Venus to the ecliptic, some inferior conjunctions are more favorable for such a search than others. The inferior conjunctions on June 17, 1972 and June 15, 1980 are most favorable for detection.

Russell, C. T.↗

Electrophoretic device and method to separate and detect analyte ions

This invention is directed to an inexpensive, miniaturized, portable, low-power device and method for electrophoretic separation and electrochemical detection of an analyte, including different isotopes of the same element. The invention replaces a conventional or microfabricated capillary electrophoresis tube with a microchip comprising an array of parallel electrophoretic separation nanotubes or aligned hollow channels fabricated in a porous substrate.

Klavetter, Kyle C.↗

Rigid versus Flexible Ligands on Carbon Nanotubes for the Enhanced Sensitivity of Cobalt Ions

Carbon nanotubes have shown great promise in the fabrication of ultra-compact and highly sensitive chemical and biological sensors. Additional chemical functionalization schemes can controllably improve selectivity of the carbon nanotube-based sensors; however the exact transduction mechanism is still under debate. In this article we detail the synthesis and selective response of single-walled carbon nanotubes (SWNTs) functionalized with polyazomethine (PAM) polymer towards the application of a specific trace metal ion detector. The response of the polymer system was compared to shape persistent macrocycle (MAC) comprised of identical ion coordination ligands. While ion detection with rigid MAC/SWNT chemiresistor was comparable to bare SWNT, flexible PAM offers significant SWNT signal amplification, allowing for picomolar detection of Co{sup 2+} ions with both selectivity and a fast response. We hypothesized that rearrangement of the flexible PAM on the SWNT network is a sensing mechanism which allows for ultrasensitive detection of metal ions. The electron transfer and polymer rearrangement on the SWNT was studied by a combination of optical spectroscopy and electrical measurements - ultimately allowing for a better understanding of fundamental mechanisms that prompt device response.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A magnetic-bottle multi-electron-ion coincidence spectrometer

A novel multi-electron-ion coincidence spectrometer developed on the basis of a 1.5 m-long magnetic-bottle electron spectrometer is presented. Electrons are guided by an inhomogeneous magnetic field to a detector at the end of the flight tube, while a set of optics is used to extract counterpart ions to the same detector, by a pulsed inhomogeneous electric field. This setup allows ion detection with high mass resolution, without impairing the high collection efficiency for electrons. The performance of the coincidence spectrometer was tested with double ionization of carbon disulfide, CS{sub 2} {yields} CS{sub 2}{sup 2+} + e{sup -} + e{sup -}, in ultrashort intense laser fields (2.8 x 10{sup 13} W/cm{sup 2}, 280 fs, 1030 nm) to clarify the electron correlation below the rescattering threshold.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗