The response of monoenergetic gamma rays in finite media are investigated

In a study of the transport of radiation in matter, the response parameters of monoenergetic gamma rays incident on various materials with finite geometries were calculated on a CDC 3600 computer. The report includes results for gamma rays normal to cyclindrical germanium and silicon detectors.

Snow, W. J.

A Geant Study of the Scintillating Optical Fiber (SOFCAL) Cosmic Ray Detector

Recent energy measurements by balloon-borne passive emulsion chambers indicate that the flux ratios of protons to helium nuclei and of protons to all heavy nuclei decrease as the primary cosmic ray energy per nucleon increases above approx. 200 GeV/n, and suggest a "break" in the proton spectrum between 200 GeV and 5 TeV. However, these passive emulsion chambers are limited to a lower energy threshold of approx. 5 TeV/n, and cannot fully explore this energy regime. Because cosmic ray flux and composition details may be significant to acceleration models, a hybrid detector system called the Scintillating Optical Fiber Calorimeter (SOFCAL) has been designed and flown. SOFCAL incorporates both conventional passive emulsion chambers and an active calorimeter utilizing scintillating plastic fibers as detectors. These complementary types of detectors allow the balloon-borne SOFCAL experiment to measure the proton and helium spectra from approx. 400 GeV/n to approx. 20 TeV. The fundamental purpose of this study is to use the GEANT simulation package to model the hadronic and electromagnetic shower evolution of cosmic rays incident on the SOFCAL detector. This allows the interpretation of SOFCAL data in terms of charges and primary energies of cosmic rays, thus allowing the determinations of cosmic ray flux and composition as functions of primary energy.

Munroe, Ray B., Jr.

Design, Testing, and Implementation of the Marshall Grazing Incidence X-ray Spectrometer Slit-Jaw Context Imaging System

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a NASA sounding rocket payload providing a 0.6 – 2.5 nm spectrum with unprecedented spatial and spectral resolution. The instrument is comprised of a novel optical design, featuring a Wolter 1 grazing mirror in the telescope module focusing the solar image on a slit plate; two corrective optics, a diffraction grating and a low-noise detector make up the spectrometer module. When MaGIXS flies on a suborbital launch in 2020, a slit-jaw camera system will image the sun in extreme ultraviolet (EUV) to soft x-ray wavelengths, providing a reference for pointing the telescope and aligning the data to supporting observations from satellites.

Phillip Wilkerson

Solar corona studies using normal-incidence X-ray optics

The progress which has been made in constructing a new type of X-ray telescope, which operates at normal incidence in the soft X-ray region by the use of multilayer coatings is described. The principles involved in state-of-the-art multilayer technology and some high-resolution imaging results are discussed. A rocket payload incorporating a multilayer X-ray mirror is presently being constructed. It is of Ritchey-Chretien design and the expected spatial resolution is 1/4 arcsec. The scientific program for solar-coronal studies and future instrumental developments are also discussed.

Golub, L.

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) Solar Sounding Rocket Campaign – Calibration and Performance

The Marshall Grazing Incidence X-ray Spectrometer (MaGIXS) is a sounding rocket experiment that is designed to observe, for the first time, soft X-ray spectra of high-temperature, low-emission plasma of coronal structures spatially resolved along a narrow slit.MaGIXS observation involves a set of high temperature spectral lines in soft X-rays from 0.5 - 2.0 keV from an active region core,which will extend the DEM coverage from 3MK to 10MK constraining the slope of the DEM fall-off. The novel instrument designincludes a Wolter-I type telescope and a 3-optic grazing-incidence spectrometer. The spectrometer consists of a finite conjugatemirror pair and a blazed planar, varied line spaced grating, which disperses the rays on to a CCD and provides a high spatial andspectral resolution. Component level instrument testing, integration of the instrument and end-to-end X-ray calibration are carriedout using the X-ray and Cryogenic Facility (XRCF) at NASA Marshall Space Flight Center. MaGIXS is scheduled for launch in2021. We will present the results of X-ray calibration tests for MaGIXS and discuss the expected inflight performance throughdifferent solar observation scenarios.

P. S. Athiray

Design of grazing-incidence X-ray telescopes. I.

The theoretical and practical constraints on designs of grazing-incidence X-ray telescopes are discussed. It is shown that there is a maximum useful diameter for an X-ray telescope. It is further shown that when practical constraints are considered, the maximum reflecting area is not necessarily achieved by utilizing the largest available area within this diameter. Equations are derived that allow rapid calculation of the effective area of an X-ray telescope before one proceeds to detailed studies utilizing Monte Carlo techniques.

Weisskopf, M. C.

Electroformed grazing incidence X-ray mirrors for a mirror array telescope

Grazing incidence Wolter type I mirrors for higher-energy X-rays have been replicated from two superpolished mandrels by electroforming. Single mirrors and a nested pair were tested with 1.5- and 6.4-keV X-rays, and their subminute of arc resolution and reflectivity close to the theoretical values are confirmed. The design of the mandrels, the mirror mounting scheme, and results of the X-ray test are presented. The microroughnesses of the mirrors measured using an optical profilometer were compared with the X-ray test results.

Ulmer, Melville P.

Bent crystal spectrometer for solar X-ray spectroscopy

A bent crystal spectrometer employs a collimated beam of X-rays incident on the crystal over a range of Bragg angles determined by the orientation and curvature of the crystal surface. It provides continuous and simultaneous coverage of all X-ray wavelengths within its spectral range. In-flight testing for solar X-ray spectroscopy was performed using a small instrument to supplement the wavelength coverage of several scanning spectrometers used to study solar active regions in the 9-24 A range. Later testing included modifications to alleviate problems caused by ultraviolet radiation. Future usage of the device will include studies of time variable emission from solar flares or discrete galactic X-ray sources, and the first major experiment to utilize bent crystal spectrometers will be the Solar Maximum Mission satellite in 1979.

Rapley, C. G.

Optical scanner

An optical scanner for imaging lines in an object plane onto a linear array in a focal plane either continuously or discretely is described. The scanner consists of a set of four mutually perpendicularly oriented plane corner mirrors which provide a reflecting path that describes a parallelogram. In addition, there is a plane parallel scanning mirror with a front and back reflecting surface located midway between the first and fourth corner mirrors. It is oriented so that in the mid-scan position it is parallel to the first corner mirror, and therefore perpendicular to the fourth corner mirror. As the scan mirror rotates, rays incident from a plurality of lines in the object plane are selectively directed through the optical system arriving at a common intersection on the back surface of the scanning mirror where the rays are colinearly directed toward a lens and then imaged onto the linear array in the focal plane. A set of compensating mirrors may be introduced just before the imaging lens to compensate for a small and generally negligible path difference delta sub l between the axial and marginal rays.

Finkel, Mitchell W.

Light ray tracing through a leaf cross section

A light ray, incident at about 5 deg to the normal, is geometrically plotted through the drawing of the cross section of a soybean leaf using Fresnel's equations and Snell's law. The optical mediums of the leaf considered for ray tracing are: air, cell sap, chloroplast, and cell wall. The ray is also drawn through the same leaf cross section with cell wall and air as the only optical mediums. The values of the reflection and transmission found from the ray tracing tests agree closely with the experimental results obtained using a Beckman Dk-2A Spectroreflector.

Kumar, R.

Light ray tracing through a leaf cross section

A light ray, incident at about 5 deg to the normal, is geometrically plotted through the drawing of the cross section of a soybean leaf using Fresnel's equations and Snell's law. The optical mediums of the leaf considered for ray tracing are air, cell sap, chloroplast, and cell wall. The above ray is also drawn through the same leaf cross section considering cell wall and air as the only optical mediums. The values of the reflection and transmission found from ray tracing agree closely with the experimental results obtained using a Beckman DK-2A spectroreflectometer.

Kumar, R.

X-Ray Diffraction Wafer Mapping Method for Rhombohedral Super-Hetero-Epitaxy

A new X-ray diffraction (XRD) method is provided to acquire XY mapping of the distribution of single crystals, poly-crystals, and twin defects across an entire wafer of rhombohedral super-hetero-epitaxial semiconductor material. In one embodiment, the method is performed with a point or line X-ray source with an X-ray incidence angle approximating a normal angle close to 90 deg, and in which the beam mask is preferably replaced with a crossed slit. While the wafer moves in the X and Y direction, a narrowly defined X-ray source illuminates the sample and the diffracted X-ray beam is monitored by the detector at a predefined angle. Preferably, the untilted, asymmetric scans are of {440} peaks, for twin defect characterization.

Park, Yoonjoon

Non-tracking solar energy collector system

A solar energy collector system is described characterized by an improved concentrator for directing incident rays of solar energy on parallel strip-like segments of a flatplate receiver. Individually mounted reflector modules of a common asymmetrical triangular cross-sectional configuration supported for independent orientation are asymmetric included with vee-trough concentrators for deflecting incident solar energy toward the receiver.

Selcuk, M. K.

A model of an X-ray-illuminated accretion disk and corona

The X-ray-illuminated surface of the accretion disk in a low-mass X-ray Binary (LMXRB) and the X-ray-heated corona above the disk produce optical, UV, and soft X-ray emission lines. This paper presents 1D models of the emission line spectra and the vertical temperature and density structures at different radii. The models include a detailed treatment of the important atomic processes and an escape probability treatment of radiative transfer. Soker and Raymond (1993) use the density structure predicted by these models for a 2D Monte Carlo simulation of the photon scattering in the accretion disk corona (ADC) to examine the effects of the ADC on the angular distribution of X-rays and the flux of X-rays incident on the outer disk. This paper concentrates on the emission line fluxes for various elemental abundances and disk parameters. The UV lines of the classic LMXRBs are consistent with the model predictions. Some CNO processing is necessary to account for the nitrogen and helium abundances in Sco X-1 and other LMXRBs. Comparison of the models with observed spectra also points to a soft X-ray component with luminosity comparable to the hard X-rays. The models predict a substantial luminosity in the group of highly ionized iron lines near 100 A.

Raymond, John C.

Differential Deposition to Correct Surface Figure Deviations in Astronomical Grazing-Incidence X-Ray Optics

A coating technique is being developed to correct the surface figure deviations in reflective-grazing-incidence X-ray optics. These optics are typically designed to have precise conic profiles, and any deviation in this profile, as a result of fabrication, results in a degradation of the imaging performance. To correct the mirror profiles, physical vapor deposition has been utilized to selectively deposit a filler material inside the mirror shell. The technique, termed differential deposition, has been implemented as a proof of concept on miniature X-ray optics developed at MSFC for medical-imaging applications. The technique is now being transferred to larger grazing-incidence optics suitable for astronomy and progress to date is reported.

Kilaru, Kiranmayee

Flares observed by the normal incidence X-ray telescope on 1989 September 11

Two solar flare events have been observed in soft X-rays during a sounding-rocket flight of the Normal-Incidence X-ray Telescope payload on September 11, 1989. The flare in X-rays involves a single bright loop crossing the neutral line, and having its footpoints at the southern ends of the ribbons; this loop accounts for more than 66 percent of the emission. Within the remainder of each of the flare ribbons, a complex coronal structure is also observed to be interacting with the main flare loop. A second event, in an active region at the limb, has a strong correlation with H-alpha images obtained at the same time. This indicates the coexistence, and indeed the close proximity, of coronal and chromospheric temperature material. Interpretations of this phenomenon are discussed.

Herant, M.

Grazing Incidence Optics for X-rays Interferometry

Grazing incidence mirror parameters and constraints for x-ray interferometry are described. We present interferometer system tolerances and ray trace results used to define mirror surface accuracy requirements. Mirror material, surface figure, roughness, and geometry are evaluated based on analysis results. We also discuss mirror mount design constraints, finite element analysis, environmental issues, and solutions. Challenges associated with quantifying high accuracy mirror surface quality are addressed and test results are compared with theoretical predictions.

Shipley, Ann