Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “IDS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Time-Based CAN IDS Paper Results Code

Modern vehicles are complex cyber-physical systems made of hundreds of electronic control units (ECUs) that communicate over controller area networks (CANs). This inherited complexity has expanded the CAN attack surface which is vulnerable to message injection attacks. These injections change the overall timing characteristics of messages on the bus, and thus, to detect these malicious messages, time-based intrusion detection systems (IDSs) have been proposed. However, time-based IDSs are usually trained and tested on low-fidelity datasets with unrealistic, labeled attacks. This makes difficult the task of evaluating, comparing, and validating IDSs. Here we detail and benchmark four time-based IDSs against the newly published ROAD dataset, the first open CAN IDS dataset with real (non-simulated) stealthy attacks with physically verified effects. We found that methods that perform hypothesis testing by explicitly estimating message timing distributions have lower performance than methods that seek anomalies in a distribution related statistic. In particular, these “distribution-agnostic” based methods outperform “distribution-based” methods by at least 55% in area under the precision-recall curve (AUC-PR). Our results expand the body of knowledge of CAN time-based IDSs by providing details of these methods and reporting their results when tested on datasets with real advanced attacks. Finally, we develop an after-market plug-in detector using lightweight hardware, which can be used to deploy the best performing IDS method on nearly any vehicle.

Moriano, Pablo [Oak Ridge National Lab. (ORNL), Oa↗

A New Experimental Station for Liquid Interface X-Ray Scattering At NSLS-II Beamline 12-ID

Open Platform and Liquids Scattering (OPLS) is a new experimental station recently built and currently being commissioned at the Soft Matter Interfaces (SMI) beamline 12-ID at NSLS-II. The new instrument expands SMI’s beamline scientific capabilities via the addition of X-ray scattering techniques from liquid surfaces and interfaces. The design of this new instrument, located inside the 12-ID beamline shielding enclosure (hutch B), is based on a single Ge (111) crystal deflector, which bounces the incident x-ray beam downward towards a liquid sample which must be maintained in a horizontal orientation (gravity-driven consideration). The OPLS instrument has a variable deflector-to-sample distance ranging from 0.6 m to 1.5 m. X-ray detectors are mounted on a 2-theta scattering arm located downstream of the sample location. The 2-theta arm is designed to hold up to three X-ray detectors, with fixed 2-theta angular offsets, each dedicated to a different X-ray technique such as X-ray reflectivity, grazing-incidence X-ray scattering, and small- and wide-angle X-ray scattering. Currently, the OPLS experimental station intercepts the SMI beam that otherwise propagates to the experimental endstation located in hutch C and can be retracted to a ’parking’ position laterally out of this beam to allow installation of a removable beam pipe that is needed to support operations in hutch C. The design of OPLS is flexible enough to quickly adapt to a planned future configuration of the SMI beamline in which a OPLS is illuminated separately from the main SMI branch via a second, canted undulator source and a separate photon delivery system. In this future configuration, both branches will be able to operate independently and simultaneously.

36 MATERIALS SCIENCE↗

Level-2 Milestone 3244: Deploy Dawn ID Machine for Initial Science Runs

This report documents the delivery, installation, integration, testing, and acceptance of the Dawn system, ASC L2 milestone 3244: Deploy Dawn ID Machine for Initial Science Runs, due September 30, 2009. The full text of the milestone is included in Attachment 1. The description of the milestone is: This milestone will be a result of work started three years ago with the planning for a multi-petaFLOPS UQ-focused platform (Sequoia) and will be satisfied when a smaller ID version of the final system is delivered, installed, integrated, tested, accepted, and deployed at LLNL for initial science runs in support of SSP mission. The deliverable for this milestone will be a LA petascale computing system (named Dawn) usable for code development and scaling necessary to ensure effective use of a final Sequoia platform (expected in 2011-2012), and for urgent SSP program needs. Allocation and scheduling of Dawn as an LA system will likely be performed informally, similar to what has been used for BlueGene/L. However, provision will be made to allow for dedicated access times for application scaling studies across the entire Dawn resource. The milestone was completed on April 1, 2009, when science runs began running on the Dawn system. The following sections describe the Dawn system architecture, current status, installation and integration time line, and testing and acceptance process. A project plan is included as Attachment 2. Attachment 3 is a letter certifying the handoff of the system to a nuclear weapons stockpile customer. Attachment 4 presents the results of science runs completed on the system.

99 GENERAL AND MISCELLANEOUS↗

INL CRMO XRF Report 2025-02: Provenance Determinations for 1,124 Projectile Points from Lands and Collections Managed by the U.S. Department of Energy-Idaho Operations Office (DOE-ID)

This report presents provenance determinations for 1,124 obsidian and fine-grained volcanic (FGV) projectile points from lands and collections managed by the U.S. Department of Energy-Idaho Operations Office (DOE-ID). These determinations were made using energy-dispersive X-ray fluorescence (ED-XRF) spectrometry at the Idaho National Laboratory (INL) Cultural Resource Management Office (CRMO) under the direction of Dr. Kyle Freund.

58 GEOSCIENCES↗

Determination of Trace Elements in Uranium by HPLC-ID-ICP-MS: NTNFC Final Report

This report covers the FY 16 effort for the HPLC-ID-ICP-MS methodology 1) sub-method validation for the group I&II elements, 2) sub-method stood-up and validation for REE, 3) sub-method development for the transition element, and 4) completion of a comprehensive SOP for three families of elements.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Proposed Confidence Scale and ID Score in the Identification of Known-Unknown Compounds Using High Resolution MS Data

High-resolution (HR) MS instruments recording HR-full scan allow analysts to go further beyond pre-acquisition choices. Untargeted acquisition can reveal unexpected compounds or concentrations and can be performed for preliminary diagnosis attempt. Then, revealed compounds will have to be identified for interpretations. Whereas the need of reference standards is mandatory to confirm identification, the diverse information collected from HRMS allows identifying unknown compounds with relatively high degree of confidence without reference standards injected in the same analytical sequence. However, there is a necessity to evaluate the degree of confidence in putative identifications, possibly before further targeted analyses. This is why a confidence scale and a score in the identification of (non-peptidic) known-unknown, defined as compounds with entries in database, is proposed for (LC-) HRMS data. The scale is based on two representative documents edited by the European Commission (2007/657/EC) and the Metabolomics Standard Initiative (MSI), in an attempt to build a bridge between the communities of metabolomics and screening labs. With this confidence scale, an identification (ID) score is determined as [a number, a letter, and a number] (e.g., 2D3), from the following three criteria: I, a General Identification Category (1, confirmed, 2, putatively identified, 3, annotated compounds/classes, and 4, unknown); II, a Chromatography Class based on the relative retention time (from the narrowest tolerance, A, to no chromatographic references, D); and III, an Identification Point Level (1, very high, 2, high, and 3, normal level) based on the number of identification points collected. Three putative identification examples of known-unknown will be presented. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of multilayer-reflected beam profiles and their coherence properties using beamlines ID19 (ESRF) and 32-ID (APS)

The use of multilayer mirrors is an interesting alternative for reflective X-ray monochromatization with respect to reflection from crystal optics. The increased photon flux density due to the multilayers' larger bandwidth is of crucial importance for, e.g, full-field X-ray imaging applications. Drawbacks are the introduced modifications of the reflected beam profile as well as a certain loss of coherence, summarized as wavefront degradation. Our recent work has shown that the modification of the beam profile can vary with, e.g., the material composition of the coating applied. In order to verify our findings, a beamline round-robin has been initiated, comparing the wavefront profiles after reflection by selected multilayers at beamlines 32-ID (Advanced Photon Source) and ID19 (European Synchrotron Radiation Facility) with our initial results acquired at BM05 (ESRF) [1].

43 PARTICLE ACCELERATORS↗

Design, characterization, and performance of a hard x-ray transmission microscope at the National Synchrotron Light Source II 18-ID beamline

A transmission X-ray microscope (TXM) has been designed and commissioned at the 18-ID Fullfield X-ray Imaging (FXI) beamline at the National Synchrotron Light Source-II (NSLS-II). This instrument operates in the 5-11 keV range, and, with the current set of optics, is capable of 30 nm spatial resolution imaging, with a field of view (FOV) of about 40 microns. For absorption contrast, the minimum exposure time for a single projection image is about 20 ms and an entire 3D tomography data set can be acquired in under one minute. The system enables tomographic reconstructions with sub-50 nm spatial resolution without the use of markers on the sample or corrections for rotation run-outs.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Pair density wave and s ± id superconductivity in a strongly coupled lightly doped Kondo insulator

Here, we investigate the large Kondo coupling limit of the Kondo-Heisenberg model on one- and two-dimensional lattices. Focusing on the possible superconducting states when slightly doping the Kondo insulator state, we identify different pairing modes to be most stable in different parameter regimes. Possibilities include uniform s-wave, pair-density-wave with momentum π (in both one and two dimensions) and uniform s ± id x 2 -y 2 wave (in two dimensions). We attribute these exotic pairing states to the presence of various pair-hopping terms with a "wrong'' sign in the effective model, a mechanism that is likely universal for inducing pairing states with spatially modulated pair wavefunctions.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

High-energy-resolution inelastic X-ray scattering spectrometer at beamline 30-ID of the Advanced Photon Source

Inelastic X-ray scattering is a powerful and versatile technique for studying lattice dynamics in materials of scientific and technological importance. In this article, the design and capabilities of the momentum-resolved high-energy-resolution inelastic X-ray spectrometer (HERIX) at beamline 30-ID of the Advanced Photon Source are reported. The instrument operates at 23.724 keV and has an energy resolution of 1.3–1.7 meV. It can accommodate momentum transfers of up to 72 nm -1 , at a typical X-ray flux of 4.5 × 10 9 photons s -1 meV -1 at the sample. A suite of in situ sample environments are provided, including high pressure, static magnetic fields and uniaxial strains, all at high or cryogenic temperatures.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Combining Laue diffraction with Bragg coherent diffraction imaging at 34-ID-C

Measurement modalities in Bragg coherent diffraction imaging (BCDI) rely on finding a signal from a single nanoscale crystal object which satisfies the Bragg condition among a large number of arbitrarily oriented nanocrystals. However, even when the signal from a single Bragg reflection with ( hkl ) Miller indices is found, the crystallographic axes on the retrieved three-dimensional (3D) image of the crystal remain unknown, and thus localizing in reciprocal space other Bragg reflections becomes time-consuming or requires good knowledge of the orientation of the crystal. Here, the commissioning of a movable double-bounce Si (111) monochromator at the 34-ID-C endstation of the Advanced Photon Source is reported, which aims at delivering multi-reflection BCDI as a standard tool in a single beamline instrument. The new instrument enables, through rapid switching from monochromatic to broadband (pink) beam, the use of Laue diffraction to determine crystal orientation. With a proper orientation matrix determined for the lattice, one can measure coherent diffraction patterns near multiple Bragg peaks, thus providing sufficient information to image the full strain tensor in 3D. The design, concept of operation, the developed procedures for indexing Laue patterns, and automated measuring of Bragg coherent diffraction data from multiple reflections of the same nanocrystal are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

AMX – the highly automated macromolecular crystallography (17-ID-1) beamline at the NSLS-II

The highly automated macromolecular crystallography beamline AMX/17-ID-1 is an undulator-based high-intensity (>5 × 10 12 photons s −1 ), micro-focus (7 µm × 5 µm), low-divergence (1 mrad × 0.35 mrad) energy-tunable (5–18 keV) beamline at the NSLS-II, Brookhaven National Laboratory, Upton, NY, USA. It is one of the three life science beamlines constructed by the NIH under the ABBIX project and it shares sector 17-ID with the FMX beamline, the frontier micro-focus macromolecular crystallography beamline. AMX saw first light in March 2016 and started general user operation in February 2017. At AMX, emphasis has been placed on high throughput, high capacity, and automation to enable data collection from the most challenging projects using an intense micro-focus beam. Here, the current state and capabilities of the beamline are reported, and the different macromolecular crystallography experiments that are routinely performed at AMX/17-ID-1 as well as some plans for the near future are presented.

36 MATERIALS SCIENCE↗

Laser, vacuum and gas reaction chamber for operando measurements at NSLS-II's 28-ID-2

We present a laser reaction chamber that we have developed for in situ/operando X-ray diffraction measurements at the NSLS-II 28-ID-2 X-ray powder diffraction beamline. This chamber allows for rapid and dynamic sample heating under specialized gas environments, spanning ambient conditions down to vacuum pressures. We demonstrate the capabilities of this setup through two applications: laser-driven heating in polycrystalline iron oxide and in single-crystal WTe 2 . Our measurements reveal the ability to resolve chemical reaction kinetics over minutes with 1 s time resolution. This setup advances opportunities for in situ/operando X-ray diffraction studies of both bulk and single-crystal materials.

36 MATERIALS SCIENCE↗

Crystal structures of the three closely related compounds: bis­­[(1H-tetra­zol-5-yl)meth­yl]nitramide, tri­amino­guanidinium 5-({[(1H-tetra­zol-5-yl)meth­yl](nitro)­amino}­meth­yl)tetra­zol-1-ide, and di­ammonium bis­­[(tetra­zol-1-id-5-yl)meth­yl]nitramide monohydrate

In the mol­ecule of neutral bis­[(1H-tetra­zol-5-yl)meth­yl]nitramide, (I), C 4 H 6 N 10 O 2 , there are two intra­molecular N—H∙∙∙O hydrogen bonds. In the crystal, N—H∙∙∙N hydrogen bonds link mol­ecules, forming a two-dimensional network parallel to (-201) and weak C—H∙∙∙O, C—H∙∙∙N hydrogen bonds, and inter­molecular π–π stacking completes the three-dimensional network. The anion in the molecular salt, tri­amino­guanidinium 5-({[(1H-tetra­zol-5-yl)meth­yl](nitro)­amino}­meth­yl)tetra­zol-1-ide, (II), CH 9 N 6 + ·C 4 H 5 N 10 O 2 - , displays intra­molecular π–π stacking and in the crystal, N—H∙∙∙N and N—H∙∙∙O hydrogen bonds link the components of the structure, forming a three-dimensional network. In the crystal of di­ammonium bis­[(tetra­zol-1-id-5-yl)meth­yl]nitramide monohydrate, (III), 2NH 4 + ·C 4 H 4 N 10 O 2 2- ·H 2 O, O—H∙∙∙N, N—H∙∙∙N, and N—H∙∙∙O hydrogen bonds link the components of the structure into a three-dimensional network. In addition, there is inter­molecular π–π stacking. In all three structures, the central N atom of the nitramide is mainly sp 2 -hybridized. Bond lengths indicate delocalization of charges on the tetra­zole rings for all three compounds. Compound (II) was found to be a non-merohedral twin and was solved and refined in the major component.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improving I/O Throughput with PRIMACY: Preconditioning ID-Mapper for Compressing Incompressibility

The ability to efficiently handle massive amounts of data is necessary for the continuing development towards exascale scientific data-mining applications and database systems. Unfortunately, recent years have shown a growing gap between the size and complexity of data produced from scientific applications and the limited I/O bandwidth available on modern high-performance computing systems. Utilizing data compression in order to lower the degree of I/O activity offers a promising means to addressing this problem. However, the standard compression algorithms previously explored for such use offer limited gains on both the end-to-end throughput and storage fronts. In this paper, we introduce an in-situ compression scheme aimed at improving end-to-end I/O throughput as well as reduction of dataset size. Our technique, PRIMACY (Preconditioning Id-MApper for Compressing incompressibility), acts as a preconditioner for standard compression libraries by modifying representation of original floating-point scientific data to increase byte-level repeatability, allowing standard loss less compressors to take advantage of their entropy-based byte-level encoding schemes. We additionally present a theoretical model for compression efficiency in high-performance computing environments and evaluate the efficiency of our approach via comparative analysis. Based on our evaluations on 20 real-world scientific datasets, PRIMACY achieved up to 38% and 22% improvements upon standard end-to-end write and read throughputs respectively in addition to a 25% increase in compression ratios paired with 3-to-4-fold improvement in both compression and decompression throughput over general purpose compressors.

Computer Science↗

Single mimivirus particles intercepted and imaged with an X-ray laser (CXIDB ID 1)

These are the files used to reconstruct the images in the paper "Single Mimivirus particles intercepted and imaged with an X-ray laser". Besides the diffracted intensities, the Hawk configuration files used for the reconstructions are also provided. The files from CXIDB ID 1 are the pattern and configuration files for the pattern showed in Figure 2a in the paper.

AMO↗

Single mimivirus particles intercepted and imaged with an X-ray laser (CXIDB ID 2)

These are the files used to reconstruct the images in the paper "Single Mimivirus particles intercepted and imaged with an X-ray laser". Besides the diffracted intensities, the Hawk configuration files used for the reconstructions are also provided. The files from CXIDB ID 2 are the pattern and configuration files for the pattern showed in Figure 2b in the paper.

AMO↗