Uranium isotopic analysis in unpurified solutions by ICP-MS
Uranium isotope analysis in unpurified samples using ICP-MS provides accurate results across platforms.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Uranium isotope analysis in unpurified samples using ICP-MS provides accurate results across platforms.
This study demonstrates a method for determining the isotopic composition of low-level (sub-pg) plutonium (Pu) directly from a cotton swipe. Environmental sample (ES) swipes are routinely employed as a tool for monitoring activities in nuclear facilities. Traditional ES swipe analysis, as employed in nuclear safeguards, utilizes laborious ashing, digestion, and chemical separation procedures prior to mass spectrometric (MS) analysis. Here, an innovative sample introduction technique employing a microextraction probe to extract Pu directly from the swipe surface is described. The microextraction probe lowers onto the swipe surface, seals on a small area (8 mm 2 ), and delivers solvent (2% HNO 3 ) to extract actinide material that may be present. The extracted analyte is subsequently directed into a sector field inductively coupled plasma (ICP)-MS for isotope ratio determination. This microextraction-ICP-MS method successfully determined the isotopic composition ( 240 Pu/ 239 Pu and 242 Pu/ 239 Pu) of three Pu certified reference materials (CRM 136, 137, and 138) that were deposited (1 pg) onto ES swipes. The percent relative difference from the certified value, uncorrected for instrumental fractionation, was <2% for the 240 Pu/ 239 Pu ratio on all three CRMs and <10% for the 242 Pu/ 239 Pu ratio on CRM 136 and 138. Here, the percent relative standard deviation, an estimate of the sample-to-sample isotopic precision, was <4% for the 240 Pu/ 239 Pu and <15% for the 242 Pu/ 239 Pu. Method limits of detection were determined, based on measurements of an enriched 244 Pu material, to be ~7 fg. Additionally, a mixed uranium (U) and Pu deposition was made to determine the method's ability to simultaneously extract U and Pu and determine the isotopic composition of both analytes.
We present a method for analyzing rare earth elements (REEs) by isotope dilution without separation of individual elements. Utilizing a Nu Plasma 2 multicollector inductively coupled plasma mass spectrometer (MC-ICP-MS) equipped with an Aridus II desolvation nebulizer, sample introduction tuning parameters (torch position, gas flows) were investigated and used to minimize oxide formation (e.g., NdO/Nd <0.05%) and remove the need to analyze the REEs as separated “cuts.” Ratios for spike/sample isotopes in mixed synthetic standards containing varying amounts of Ce, Nd, Sm, Eu, Gd, Dy, Er, and Yb were measured accurately within 1% of IUPAC values. La and Lu in the standards were more than 2% off from expected values due to more demanding interference corrections. A USGS BCR-2 rock standard was also processed with flux fusion, iron coprecipitation and a single column pass bulk separation followed by analysis. The concentrations for Ce, Nd, Sm, Eu, Dy, Er, and Yb fell within 2% of consensus values. A United States Geological Survey (USGS) BIR-1A rock standard was also processed in triplicate by hydrofluoric and nitric acid digestion, yielding rare earth concentrations within 3% of consensus values with 0.3% relative standard deviation (n=3). This demonstrates the ability to produce high quality REE patterns of comparable quality to traditional methods involving labor and time intensive REE separation, with sample preparation and analytical times that are comparable to analyses against isotope dilution by single-collector ICP-MS.
In this study, we use laser ablation MC-ICP-MS as a rapid sampling tool to characterize the isotopic composition of uranium in μm-sized uranium oxide particles.
Trace-level measurements of iodine’s isotopic ( 129 I and 127 I) and chemical species distributions are needed for an accurate understanding of radioiodine migration in the Hanford subsurface. Pacific Northwest National Laboratory (PNNL) previously developed a novel analytical method for iodine characterization that uses ion chromatography (IC) coupled to inductively coupled mass spectrometry (ICP-MS). While the method can measure speciated forms of 129 I at levels below the drinking water standard, an interference from molybdenum (Mo) prevents the assay from quantifying the $\underline{total}$ 129 I concentration in many Hanford sample matrices. In this work, solvent extraction was evaluated as a sample preparation method for eliminating the Mo interference. A series of 10 experiments was conducted in which solutions containing known amounts of iodate or iodide were treated by solvent extraction, and the extracted solutions were analyzed for total iodine concentrations by ICP MS. Several extraction parameters such as reagent concentrations and chemical reaction times were systematically adjusted in attempts to optimize the extraction process. While solvent extraction was shown to be effective at removing Mo, there was a consistent inability to recover more than approximately 75% of the total iodine in most experiments. This would reduce the ability to detect 129 I at levels near the drinking water standard. Additionally, the extraction efficiencies in several experiments were highly variable, suggesting that solvent extraction could add significant uncertainty to radioiodine measurements. We recommend evaluating ion exchange as an alternative sample preparation approach in fiscal year (FY) 2024.
In this study we utilize an all-faraday cup detector configuration on the Neoma MC-ICP-MS to perform uranium isotope ratio determinations from certified reference materials and a nuclear fuel precursor material via solution and laser ablation based sampling methodologies. The goal in performing these measurements is primarily to demonstrate that the all-faraday cup method can produce highly precise and accurate isotope ratios even at relatively low signal intensity levels while also developing a preliminary understanding of how the complex interplay between different amplifier resistor levels (e.g. 10 11 vs 10 13 Ω) and integration times impacts the precision and accuracy of different types of measurements. Our results show that the faraday cups with 1013 Ω resistors in their amplifier feedback loops can be used to produce accurate and relatively precise isotope ratios for ion beams down to ~5 K cps. However, at the lower end of the signal intensities observed in this study, longer integration times are necessary to mitigate the impact of ion beam instability that can occur during laser ablation based sampling. Despite this potential limitation, the all-faraday cup method is highly versatile as exemplified by the analysis of a collection of uranium reference materials with highly variable uranium isotopic compositions.
Coal and coal-related fly ash often contain rare earth elements (REEs) that have the potential to be utilized as valuable mineral resources. Accurately determining the REE content in coal and fly ash is crucial for resource evaluation. The conventional approach involves using hydrofluoric acid (HF) to dissolve silicates and release REEs, which, however, prolongs the digestion process due to the additional step of complexing fluoride ions (F−) with boric acid (H3BO3). Determining the correct amount of H3BO3 for neutralization can be challenging, and in some instances, the binding of fluoride ions with certain lanthanides (Lns) hampers the accurate determination of all 14 naturally occurring rare earth elements in a single digestion batch by inductively coupled plasma mass spectrometry (ICP-MS). In this study, we present an alternative method that achieves the accurate determination of all 14 naturally occurring REEs using tetrafluoroboric acid (HBF4) followed by ICP-MS analysis. This approach eliminates the need for an F− complexing step. We tested this method on certified REE reference materials, including NIST 1632e (coal) and NIST 1633c (fly ash), as well as the REE geological reference material USGS AGV-1 (andesite). Our results demonstrated excellent recovery rates (relative standard deviation, RSD < ±10%), with a correlation coefficient (r2) exceeding 0.99. Using this method, we investigated the concentrations of all 14 REEs in coal and fly ash samples collected from various locations in the southwestern USA. This improved digestion technique streamlines the analysis process and enhances the accuracy of REE determination, facilitating a more comprehensive evaluation of REE-rich coal and fly ash deposits for resource exploration.
We report a tandem ICP-MS/MS method using O 2 gas for chlorine isotopic ratio determinations, with improved accuracy and increased throughput.
Correct function and calibration of instrumentation is a crucial assumption for any scientific experiment. One such instrument, tandem inductively coupled plasma mass spectrometer (ICP-MS/MS), has in-depth calibration settings that range across 30+ different parameters, making it difficult to determine optimal conditions without expertise and some degree of trial and error. Often, these settings are hand-tuned, a time-intensive process prone to local maxima and human error. While some automation is available, the automation also may favor local optimizations over a global optimum. In addition to these difficulties, day to day instrument variability can further complicate the calibration process. We propose a solution to this problem as a machine learning (ML) algorithm that learns how each parameter helps determine the calibration sensitivity across several elements, and re-weights parameters over time as instrument variability changes (e.g., a global neural network (NN) with a time-dependent transfer learning (TL) component). This model would be able to generate a surface of predicted calibration sensitivities and their respective parameters, and a simple multivariate algorithm would be able to pull out the optimum results with the settings associated with them. Here-in, we describe our initial findings in working towards this goal, including data extraction from historical files, exploratory data analysis, and some initial model building to better describe the data and the feasibility of our goal.
A microextraction sampling system coupled to a quadrupole inductively coupled plasma-mass spectrometer (ICP-MS) was utilized to spatially discern uranium particles, isotopically, on a cellulose-based swipe material ( i.e. , J-type swipe).
Dust particulate fallout on materials in use for rare-event searches is a concerning source of radioactive backgrounds due to the presence of the naturally occurring radionuclides 40 K, 232 Th, 238 U, and their progeny in dust. Much effort is dedicated to inform radioactive backgrounds from dust and evaluate the efficacy of mitigation procedures. A great portion of such effort relies on fallout models and assumed dust composition. Here, in this work, an ICP-MS based methodology was employed for a direct determination of fallout rates of radionuclides and stable isotopes of interest from dust particulate at the SNOLAB facility. Hosted in an active mine, the SNOLAB underground laboratory strives to maintain experimental areas at class 2000 cleanroom level. This work validates the mitigation procedures in place at SNOLAB and informs dust backgrounds during laboratory activities. Fallout rates of major constituents of the local rock were measured two to three orders of magnitude lower in the clean experimental areas compared to non-clean transition areas from the mine to the laboratory. An increase of approximately two orders of magnitude in the fallout rate of stable Pb isotopes was determined in an experimental area during activities involving handling of Pb bricks. Increased 40 K, 232 Th, and 238 U fallout rates were measured in clean experimental areas during activities generating particulate.
Use of a microextraction device allows for ready sampling of solid substrates, such as cotton swipes, allowing transfer of sub-microgram quantities for multielement ICP-MS analysis.
Double-Wien filter-selection-aperture and hexapole-collision-cell technologies coupled to laser ablation multicollector inductively coupled plasma mass spectrometry (LA-MC-ICP-MS/MS) enables in situ analysis of 87 Sr variations produced by 87 Rb decay.
Rationale: Mass spectrometric measurement of the 230 Th/ 234 U ratio to calculate the purification age of enriched uranium is typically conducted via a combination of ion counters and faraday detectors, thus requiring an inter-detector calibration scheme. Here, our aim is to understand whether the pursuit of a simplified measurement scheme involving only faraday detectors is feasible. Methods: We investigate the possibility of determining U-Th model ages for two enriched uranium standards (NBL U630 and U850) by direct measurement of the 230 Th/ 234 U ratio (without chromatographic separation or isotope dilution) on a ThermoFisher Scientific Neoma MC-ICP-MS utilizing both solution and laser ablation (LA)-based sampling techniques and an all-faraday detector configuration. Results: For the solution mode analyses conducted on aliquots containing sub μg/mL total U, we produce composite average 230 Th/ 234 U model dates of May 19, 1988 (± 351 days), and March 26, 1961 (± 2.5 years) using the directly measured 230 Th/ 234 U ratios for the NBL U630 and U850 uranium standards, which have certified purification dates of June 6, 1988 (± 190 days), and December 31, 1957 (± 36.5 days), respectively. The ages produced by LA-based sampling of dried residues of the same standards deposited onto cotton TexWipes are less accurate and of poorer precision (June 23, 2004 ± 8.7 years for U630 and December 21, 1965 ± 7.9 years for U850) but still yield meaningful information in regards to the purification date. Conclusions: We believe that further refinement of the all faraday detector measurement approach to include development of a more robust Th/U relative sensitivity factor determination, signal cutoff selection, and data processing protocols will allow for this approach to be confidently applied to enriched uranium materials with unknown purification histories. Potential advantages of the method include the reduced sample handling and infrastructure requirements as well as the ability to simultaneously generate a broad picture of the uranium isotopic composition in tandem with the U-Th age determination.
Carbon dioxide (CO 2 ) was used as a reaction gas to investigate the gas‐phase ion‐molecule interactions using the Agilent 8900 ICP‐MS/MS. A solution containing forty‐five elements representative of the periodic table was used to supply the ions to react with CO 2 in the collision/reaction cell (CRC). The only significant product ions formed were monoxides. The general reactivity was shown to be consistent with density functional theory (DFT)‐predicted reaction enthalpies, such that all predicted exothermic reactions produced product ions at levels of at least 1% of the unreacted ion. Most endothermic reactions observed had sufficient kinetic energy in excess of the reaction enthalpies. Our results suggest that reaction enthalpy is a reasonable predictor of reactivity with CO 2 on the timescales of the interactions in non‐thermal ICP‐MS/MS systems. The ease and rapidity of data collection with the ICP‐MS/MS and DFT calculations using the NWChem suite has value given the scarcity of thermochemical data of CO 2 reactions in the literature. These studies are especially useful for the identification of targeted reaction chemistries to be leveraged for analytical method development, such as for the inline separation of isobaric interferences from analytes of interest.
Information about elemental and isotopic systematics of ultra-trace level actinides (e.g. U and Pu) and main group elements (e.g. Ti) present within nuclear grade graphite is vital to the nuclear community for improved reactor operation and security. In support of this, extensive effort has been placed on improving analysis methods (i.e., inductively coupled plasma-mass spectrometry). However, significantly less effort has been devoted to the optimization of chemical separation methods. Within the separation community, commercially available Eichrom™ resins are often employed, as their elution characteristics for various elements have been well studied, but the direct optimization of actinides and trace metal separations from a single sample have not been widely investigated. Here, methods using various Eichrom pre-packed cartridges were explored to achieve separation of ultra-trace levels of U, Pu, and Ti from a variety of graphite samples. Once the validity of the combined separation scheme was established using certified reference materials, the method was applied to historic, unirradiated and irradiated, graphite samples. For all samples investigated, precise isotope ratio measurements for the titanium isotope systems were made.
A sample introduction technique was developed to allow for online, dropwise injection of effluent into a mass spectrometer (MS). This allowed for the coupling of chromatography systems that were not driven by pumps without altering the set-up or separation performance. This capability combined the benefits of coupling separation and measurement while also enabling accurate chromatographic evaluation that would generally be performed offline. The incorporation of a flowing rinse into the system made dropwise resolution possible for any liquid capable of forming drops under ambient conditions. The technique was demonstrated utilizing gas pressurized extraction chromatography (GPEC) and inductively coupled plasma-time-of-flight mass spectrometry (ICP-TOFMS) to illustrate the qualitative applications for rapid separation development and procedure evaluation. This method's quantitative applications were evaluated using single and double isotope dilution mass spectrometry (IDMS) with an external mass bias correction to measure analytes across entire elutions including volumes as small as single drops. In conclusion, the total neodymium values afforded by both single and double IDMS were within the uncertainty of the calculated value for evaluation of full elution peaks and for most of the single drops analyzed that reached above 10k cps Nd-144.
A comprehensive understanding of when and how 5f orbitals participate in complex chemical bonding is important for a variety of applications. The actinides are unique in that they possess 5f orbitals and can access high oxidation states, which make them attractive for use in catalysis. Fundamental studies of actinide–ligand interactions offer a mechanism to examine the activation of the 5f orbitals so that the selectivity of 5f orbitals can be assessed. A previous study examined the reaction of Pu + + CO 2 and determined that the reaction efficiency is restricted by a barrier, namely, promotion from the Pu + ground-state configuration, 5f 6 7s, to a reactive-state configuration, 5f 5 6d 2 . Here, the present study illustrates the benefit of activation of Pu’s 5f orbitals when studying the reaction of Pu + + NO. In this reaction, PuO + forms in an exothermic, barrierless process. The 5f orbitals can and do participate in forming a linear intermediate, [N-Pu-O] + , and this drives the exothermic reaction. Understanding the conditions under which 5f orbitals are active in chemical bonding is the key to exploiting the actinides’ selective catalytic capabilities.