Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ICD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Comparison of several inflow control devices for flight simulation of fan tone noise using a JT15D-1 engine

The paper describes the tests of four devices intended to reduce inflow disturbances and turbulences using a JT15D-1 turbofan engine. The tests were made to simulate the in-flight fan tone noise; the inflow control devices (ICD's) consisted of honeycomb/screen structures mounted over the engine inlet. The ICD's ranged from 1.6 to 4 fan diameters in size, and were made with several fabrication methods. All the ICD's significantly reduced the BPF tone in the far-field directivity patterns, but the smallest ICD's introduced propagating modes which could be recognized by additional lobes in the patterns. The JT15D-1 engine had a tone source which generated a strong propagating mode at fan speeds corresponding to 'approach' power and higher. Data from a typical transducer showed that the unsteady inflow distortion modes were eliminated or reduced when either of the ICD's was installed.

Mcardie, J. G.↗

Turbomachinery noise studies of the AiResearch QCGAT engine with inflow control

The AiResearch Quiet Clean General Aviation Turbofan engine was tested on a vertical lift fan facility to measure the acoustic performance of two inflow control devices (ICD) of similar design, and three inlet lips of different external shape. Far-field directivity patterns calculated by existing analyses were compared with the measured fan fundamental blade passing frequency (BPF/F/) and broadband data. Installing an ICD on an engine with hardwall ducts reduced the BPF(F) tone everywhere in the far-field. When the ICD was installed on an engine with active acoustic panels, tone reduction in the forward quadrant was comparable to that in the hardwall tests; in the aft quadrant, however, tone noise was attenuated by the large acoustic panels in the bypass duct to such a degree that the ICD had little effect. Tests to compare performance of ICDs with hardwall inlet ducts showed only minor differences in the BPF(F) directivity patterns, while broadband noise was the same for both. Forward-quadrant BPF(F) and broadband directivity patterns were found to be similar for the inlet lips tested with a hardwall inlet duct. At high fan speeds, however, the shape of the analytical multimodal tone pattern from the exhaust nozzle was flatter than the measured patterns. The sources of lobes from several propagating single modes found in the forward-quadrant BPF(F) data were attributed to rotor/strut interaction and the rotor-alone pressure field.

Mcardle, J. G.↗

Density functional study of the variants of inter-Coulombic decay resonances in the photoionization of Cl@C 60

Inter-Coulombic decay (ICD) resonances in the photoionization of Cl@C 60 endofullerene molecule are calculated using a perturbative density functional theory (DFT) method. This is the first ICD study of an open shell atom in a fullerene cage. Here, three classes of resonances are probed: (i) Cl inner vacancies decaying through C 60 outer continua, (ii) C 60 inner vacancies decaying through Cl outer continua, and (iii) inner vacancies of either system decaying through the continua of Cl-C 60 hybrid levels, the hybrid Auger-ICD resonances. Comparisons with Ar@C 60 results reveal that the properties of hybrid Auger-ICD resonances are affected by the extent of level hybridization.

74 ATOMIC AND MOLECULAR PHYSICS↗

Evaluation of two inflow control devices for flight simulation of fan noise using a JT15D engine

Two inflow control devices, (ICD's) one in-duct and the other external to the duct, were tested on a JT15D engine to determine their ability to remove inflow turbulence without altering the sound transmission to the far field. The objective of the program was to develop means of accurately simulating flight fan noise on ground static test stands. The results generally indicated that both the in-duct and external ICD's were effective in reducing the inflow turbulence and the fan blade passing frequency tone generated by the turbulence. The external ICD was essentially transparent to the propagating fan tone but the in-duct ICD caused attenuation under most conditions.

Jones, W. L.↗

A compact inflow control device for simulating flight fan noise

Inflow control device (ICD's) of various shapes and sizes have been used to simulate inflight fan tone noise during ground static tests. A small, simple inexpensive ICD design was optimized from previous design and fabrication techniques. This compact two-fan-diameter ICD exhibits satisfactory acoustic performance characteristics without causing noise attenuation or redirection. In addition, it generates no important new noise sources. Design and construction details of the compact ICD are discussed and acoustic performance test results are presented.

Homyak, L.↗

A compact inflow control device for simulating flight fan noise

Inflow control device (ICD's) of various shapes and sizes have been used to simulate inflight fan tone noise during ground static tests. A small, simple inexpensive ICD design was optimized from previous design and fabrication techniques. This compact two-fan-diameter ICD exhibits satisfactory acoustic performance characteristics without causing noise attenuation or redirection. In addition, it generates no important new noise sources. Design and construction details of the compact ICD are discussed and acoustic performance test results are presented.

Homyak, L.↗

Tracing intermolecular Coulombic decay of carbon-dioxide dimers and oxygen dimers after valence photoionization

In this study, we have conducted an experimental study on the photo double ionization (PDI) of carbon-dioxide dimers at photon energies of 37 and 55 eV and oxygen dimers at photon energies of 38, 41.5, and 46 eV, while focusing on the dissociation dynamics upon single-photon absorption. The investigation was performed by applying the cold-target recoil-ion momentum spectroscopy method in order to collect and record the three-dimensional momenta of the ionic fragments and emitted electrons from the dissociating dimer in coincidence. The kinetic-energy release upon fragmentation and the electron angular distributions in the laboratory and body-fixed frames, as well as the relative electron-electron emission angle, show unambiguous experimental evidence of intermolecular Coulombic decay (ICD) in carbon-dioxide dimers upon photoionization below and above the double-ionization threshold of CO 2 monomers. The PDI of oxygen dimers is less conclusive and shows contributions from ICD and knock-off ionization mechanisms. As for atomic dimers, the present results reveal that ICD in CO 2 dimers after valence PDI can also serve as a source for low-energy electrons, known to be very relevant in biological systems, cells, and tissues.

74 ATOMIC AND MOLECULAR PHYSICS↗

Exploring the Value of Learned Representations for Automated Syndromic Definitions

Objective: To better define and automate biosurveillance syndrome categorization using modern unsupervised vector embedding techniques. Introduction: Comprehensive medical syndrome definitions are critical for outbreak investigation, disease trend monitoring, and public health surveillance. However, because current definitions are based on keyword string-matching, they may miss important distributional information in free text and medical codes that could be used to build a more general classifier. Here, we explore the idea that individual ICD codes can be categorized by examining their contextual relationships across all other ICD codes. We extend previous work in representation learning with medical data [1] by generating dense vector embeddings of these ICD codes found in emergency department (ED) visit records. The resulting representations capture information about disease co-occurrence that would typically require SME involvement and support the development of more robust syndrome definitions.

60 APPLIED LIFE SCIENCES↗

MR Imaging of Patients with Cardiac Implantable Electronic Devices (CIEDs): Implementing a Program and Optimizing CMR

Purpose of review: How to implement a program for MRI in patients with conditional and non-conditional (“legacy”) CIED. How to optimize safety and image quality in CMR? What the radiologists need to know: device programming, pre- and post-MRI CIED parameters. Recent findings: New Center for Medicare and Medicaid Services (CMS) guidelines have opened MRI to many patients with nonconditional devices. Newer pulse sequences for cardiac MRI (CMR) in device patients, including modified cine, late gadolinium enhancement and T1 mapping sequences, have resulted in improved image quality in device patients. We present several cases of CMR in device patients, including imaging of leadless pacemakers subcutaneous ICDs. Imaging pitfalls/artifacts in CMR interpretation are also presented. Summary: An organized institutional workflow with an established protocol involving proper patient screening, device programming, scan monitoring, and pre- and post-ICD interrogation minimizes risk in patients with conditional and non-conditional CIEDs. Although rare, significant changes in lead performance, power-on/reset, inappropriate pacing or ICD discharges and battery voltage depletion should be documented. High-quality scans with accurate scar characterization in CIED patients require the use of wideband sequences. CMS has recently acknowledged MRI as a reasonable test necessary for the diagnosis and treatment of beneficiaries with implanted CIEDs, improving the financial prospects and encouraging future developments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The interface character distribution of cold-rolled and annealed duplex stainless steel

The interface character distributions (ICDs) of cold-rolled and annealed duplex stainless steel specimens, previously solid-solution-heated (SHT) at 1573 K and 1323 K, are investigated using electron backscatter diffraction (EBSD) and five-parameter analysis (FPA). For the δ-ferrite phase, high concentrations of low angle grain boundaries (LAGBs) are developed, and the boundary planes are predominantly oriented on (111). High angle grain boundaries (HAGBs) with misorientations ranging from 50{sup o} to 60° are mostly pure tilt boundaries, and the boundary planes are primarily located on (112). For the austenite phase, very high density of coherent twin boundaries are introduced, implying that the boundary planes are exactly oriented on (111). The phase boundary character distribution (PBPD) appears to be connected with the K-S and N-W orientation relationships (ORs) terminating on (110) {sub F}‖(111) {sub A} and (110){sub F}‖(hkl){sub A}, respectively. - Highlights: •Five-parameter analysis was used to determine interface character distribution. •ICD results of statistical meaning were achieved. •Initial microstructure has a significant effect on ICD. •Low and high angle GBs in δ phase prefer in (111) and (112) planes, respectively. •K-S phase boundaries terminate on (110){sub F}‖(111){sub A} while N-W ones on (110){sub F}‖(hkl){sub A}.

36 MATERIALS SCIENCE↗

Efficient Intermolecular Energy Exchange and Soft-ionization of Water at Nanoplatelet Interfaces

X-ray, energetic photon and electron irradiation can ionize and electronically excite target atoms and molecules. These excitations undergo complicated relaxation and energy transfer processes that ultimately determine the manifold of system responses to the deposited excess energy. In weakly bound gas- and solution-phase samples, intermolecular Coulomb decay (ICD) and electron-transfer mediated decay (ETMD) can occur with neighboring atoms or molecules leading to efficient transfer of the excess energy to the surroundings. In ionic solids such as metal-oxides, intra- and inter-atomic Auger decay produces localized final states that lead to lattice damage and typically removal of cations from the substrate. The relative importance of Auger stimulated damage (ASD) versus ICD and ETMD in micro-solvated nanoparticle interfaces is not known. Though ASD is generally expected, essentially no lattice damage and very efficient ICD and ETMD resulting from ionization and electronic excitation of micro-solvated boehmite (AlOOH) nanoplatelets has been observed. Efficient energy transfer and soft ionization of interfacial molecules is likely a general phenomenon at gas-oxyhydroxide nanoparticle interfaces where the density of states of the ionized chemisorbed species significantly overlap the core hole states of the solid.

Jones, Brant M.↗

A systematic review of validated suicide outcome classification in observational studies

Abstract Background Suicidal outcomes, including ideation, attempt, and completed suicide, are an important drug safety issue, though few epidemiological studies address the accuracy of suicidal outcome ascertainment. Our primary objective was to evaluate validated methods for suicidal outcome classification in electronic health care database studies. Methods We performed a systematic review of PubMed and EMBASE to identify studies that validated methods for suicidal outcome classification published 1 January 1990 to 15 March 2016. Abstracts and full texts were screened by two reviewers using prespecified criteria. Sensitivity, specificity, and predictive value for suicidal outcomes were extracted by two reviewers. Methods followed PRISMA-P guidelines, PROSPERO Protocol: 2016: CRD42016042794. Results We identified 2202 citations, of which 34 validated the accuracy of measuring suicidal outcomes using International Classification of Diseases (ICD) codes or algorithms, chart review or vital records. ICD E-codes (E950-9) for suicide attempt had 2–19% sensitivity, and 83–100% positive predictive value (PPV). ICD algorithms that included events with ‘uncertain’ intent had 4–70% PPV. The three best-performing algorithms had 74–92% PPV, with improved sensitivity compared with E-codes. Read code algorithms had 14–68% sensitivity and 0–56% PPV. Studies estimated 19–80% sensitivity for chart review, and 41–97% sensitivity and 100% PPV for vital records. Conclusions Pharmacoepidemiological studies measuring suicidal outcomes often use methodologies with poor sensitivity or predictive value or both, which may result in underestimation of associations between drugs and suicidal behaviour. Studies should validate outcomes or use a previously validated algorithm with high PPV and acceptable sensitivity in an appropriate population and data source.

Swain, Richard S.↗

Automatic information extraction from childhood cancer pathology reports

The International Classification of Childhood Cancer (ICCC) facilitates the effective classification of a heterogeneous group of cancers in the important pediatric population. However, there has been no development of machine learning models for the ICCC classification. We developed deep learning-based information extraction models from cancer pathology reports based on the ICD-O-3 coding standard. In this article, we describe extending the models to perform ICCC classification. We developed 2 models, ICD-O-3 classification and ICCC recoding (Model 1) and direct ICCC classification (Model 2), and 4 scenarios subject to the training sample size. We evaluated these models with a corpus consisting of 29206 reports with age at diagnosis between 0 and 19 from 6 state cancer registries. Our findings suggest that the direct ICCC classification (Model 2) is substantially better than reusing the ICD-O-3 classification model (Model 1). Applying the uncertainty quantification mechanism to assess the confidence of the algorithm in assigning a code demonstrated that the model achieved a micro-F1 score of 0.987 while abstaining (not sufficiently confident to assign a code) on only 14.8% of ambiguous pathology reports. Our experimental results suggest that the machine learning-based automatic information extraction from childhood cancer pathology reports in the ICCC is a reliable means of supplementing human annotators at state cancer registries by reading and abstracting the majority of the childhood cancer pathology reports accurately and reliably.

60 APPLIED LIFE SCIENCES↗

SU-F-I-49: Vendor-Independent, Model-Based Iterative Reconstruction On a Rotating Grid with Coordinate-Descent Optimization for CT Imaging Investigations

Purpose: Iterative reconstruction methods show promise for improving image quality and lowering the dose in helical CT. We aim to develop a novel model-based reconstruction method that offers potential for dose reduction with reasonable computation speed and storage requirements for vendor-independent reconstruction from clinical data on a normal desktop computer. Methods: In 2012, Xu proposed reconstructing on rotating slices to exploit helical symmetry and reduce the storage requirements for the CT system matrix. Inspired by this concept, we have developed a novel reconstruction method incorporating the stored-system-matrix approach together with iterative coordinate-descent (ICD) optimization. A penalized-least-squares objective function with a quadratic penalty term is solved analytically voxel-by-voxel, sequentially iterating along the axial direction first, followed by the transaxial direction. 8 in-plane (transaxial) neighbors are used for the ICD algorithm. The forward problem is modeled via a unique approach that combines the principle of Joseph’s method with trilinear B-spline interpolation to enable accurate reconstruction with low storage requirements. Iterations are accelerated with multi-CPU OpenMP libraries. For preliminary evaluations, we reconstructed (1) a simulated 3D ellipse phantom and (2) an ACR accreditation phantom dataset exported from a clinical scanner (Definition AS, Siemens Healthcare). Image quality was evaluated in the resolution module. Results: Image quality was excellent for the ellipse phantom. For the ACR phantom, image quality was comparable to clinical reconstructions and reconstructions using open-source FreeCT-wFBP software. Also, we did not observe any deleterious impact associated with the utilization of rotating slices. The system matrix storage requirement was only 4.5GB, and reconstruction time was 50 seconds per iteration. Conclusion: Our reconstruction method shows potential for furthering research in low-dose helical CT, in particular as part of our ongoing development of an acquisition/reconstruction pipeline for generating images under a wide range of conditions. Our algorithm will be made available open-source as “FreeCT-ICD”. NIH U01 CA181156; Disclosures (McNitt-Gray): Institutional research agreement, Siemens Healthcare; Past recipient, research grant support, Siemens Healthcare; Consultant, Toshiba America Medical Systems; Consultant, Samsung Electronics.

60 APPLIED LIFE SCIENCES↗

Evaluation of two inflow control devices for flight simulation of fan noise using a JT15D engine

The program was developed to accurately simulate flight fan noise on ground static test stands. The results generally indicated that both the induct and external ICD's were effective in reducing the inflow turbulence and the fan blade passing frequency tone generated by the turbulence. The external ICD was essentially transparent to the propagating fan tone but the induct ICD caused attenuation under most conditions.

Jones, W. L.↗

Orbiter middeck/payload standard interfaces control document

The interfaces which shall be provided by the baseline shuttle mid-deck for payload use within the mid-deck area are defined, as well as all constraints which shall be observed by all the users of the defined interfaces. Commonality was established with respect to analytical approaches, analytical models, technical data and definitions for integrated analyses by all the interfacing parties. Any payload interfaces that are out of scope with the standard interfaces defined shall be defined in a Payload Unique Interface Control Document (ICD) for a given payload. Each Payload Unique ICD will have comparable paragraphs to this ICD and will have a corresponding notation of A, for applicable; N/A, for not applicable; N, for note added for explanation; and E, for exception. On any flight, the STS reserves the right to assign locations to both payloads mounted on an adapter plate(s) and payloads stored within standard lockers. Specific locations requests and/or requirements exceeding standard mid-deck payload requirements may result in a reduction in manifesting opportunities.

Source record↗

Liquid hydrogen turbopump ALS advanced development program. Volume 1: Hot fire unit

The interface criteria for the Turbopump Test article (TPA) and the Component Test Facility located at NASA, Stennis Space Center is defined by this interface Control Document (ICD). TPA ICD Volume 2 is submitted for the Cold Gas Drive Turbopump Test Article, which is generally similar but incorporates certain changes, particularly in fluid requirements and in instrumentation needs. For the purposes of this ICD, the test article consists of the Hot Fire Drive Turbopump mounted on its test cart, readied for installation in the component test facility. It should be emphasized that the LH2 turbopump program is still in its early concept design phase. Design of the turbopump, test cart, and spools are subject to revisions until successful conclusion of the Detail Design Review (DDR).

Lindley, Bruce↗

Inflight Medical Events in the Shuttle Program

Since the first launch of the Space Shuttle in 1981, the astronauts and their flight surgeons have dealt with a variety of inflight medical issues. A review will be provided of these issues as well as medications used in the treatment of these medical problems. Detailed medical debriefs are conducted by the flight ,surgeon with the individual crewmembers three days after landing. These debriefs were review for Shuttle flights from 1988 through 1999 to determine the frequency of inflight medical events. Medical events were grouped by ICD category and the frequency of medical events within those categories were reviewed. The ICD category of Symptoms, Signs and Ill-defined Conditions had the most medical events. Facial fullness and headache were the most common complaints within this category. The ICD category of Respiratory System had the next most common medical events with sinus congestion being the most common complaint. This was followed by Digestive System complaints and Nervous System/Sense Organ complaints. A variety of inflight medical events have occurred throughout the Shuttle program. Fortunately, the majority of these problems have been minor and have been well within the capability of the medical equipment flown and the skills of the Crew Medical Officers. Medical ,problems/procedures that are routine on the ground often present unique problems in the space flight environment. It is important that the flight surgeon understand the common medical problems encountered.

Baisden, Denise L.↗