An Algorithm to Derive Temperature and Humidity Profile Changes Using Spatially and Temporally Averaged Spectral Radiance Differences

A linear inversion algorithm to derive changes of surface skin temperature and atmospheric temperature and specific humidity vertical profiles using spatially and temporally averaged spectral radiance differences is developed. The algorithm uses spectral radiative kernels, which is the top-of-atmosphere spectral radiance change caused by perturbations of skin temperature and air temperature and specific humidity in the atmosphere, and is an improved version of the algorithm used in earlier studies. Two improvements are the inclusion of the residual and cloud spectral kernels in the form of eigenvectors of principal components. Three and six eigenvectors are used for, respectively, the residual and cloud spectral kernels. An underlying assumption is that the spectral shape of the principal components is constant and their magnitude varies temporally and spatially. The algorithm is tested using synthetic spectral radiances with the spectral range of the Atmospheric Infrared Sounder averaged over 16 days and over a 10° × 10° grid box. Changes of skin temperature, air temperature, and specific humidity vertical profiles are derived from the difference of nadir-view all-sky spectral radiances. The root-mean-square difference of retrieved and true skin temperature differences is 0.59 K. The median of absolute errors in the air temperature change is less than 0.5 K above 925 hPa. The median of absolute errors in the relative specific humidity changes is less than 10% above 825 hPa.

Fang Pan

Global seasonal variations of the near-surface relative humidity levels on present-day Mars

We investigate the global seasonal variations of near-surface relative humidity and relevant attributes, like temperature and water vapor volume mixing ratio on Mars using calculations from modelled and measurement data. We focus on 2 AM local time snapshots to eliminate daily effects related to differences in insolation, and to be able to compare calculations based on modelling data from the Laboratoire de Météorologie Dynamique Mars General Circulation Model with the observations of Mars Global Surveyor Thermal Emission Spectrometer. We study the seasonal effects by examining four specific dates in the Martian year, the northern spring equinox, summer solstice, autumn equinox, and winter solstice. We identify three specific zones, where the near-surface relative humidity levels are systematically higher than in their vicinity regardless of season. We find that these areas coincide with low thermal inertia features, which control surface temperatures on the planet, and are most likely covered with unconsolidated fine dust with grain sizes smaller than ∼ 40 μm. By comparing the data of relative humidity, temperature and water vapor volume mixing ratio at three different heights (near-surface, ∼ 4m and ∼ 23m above the surface), we demonstrate that the thermal inertia could play an important role in determining near-surface humidity levels. We also notice that during the night the water vapor levels drop at ∼ 4m above the surface. This, together with the temperature and thermal inertia values, shows that water vapor likely condenses in the near-surface atmosphere and on the ground during the night at the three aforementioned regions. This condensation may be in the form of brines, wettening of the fine grains by adsorption or deliquescence. This study specifies areas of interest on the surface of present day Mars for the proposed condensation, which may be examined by in-situ measurements in the future.

Bernadett Pál

Regenerable Liquid Desiccants for High Efficiency Humidity Control in Microgravity

The NASA X-Hab project aims to design, manufacture, test, and prove functionality of an air humidity control subsystem to dehumidify and re-humidify air from a space cabin. The method of regulating cabin air humidity utilizes vortex phase separation, which uses an ionic liquid (IL) desiccant for air-water phase separation. This subsystem is intended to be integrated with a CO 2 removal system requiring de-humidified air to operate efficiently. The air humidity control subsystem is composed of a cold-desiccant or cold-side Vortex Phase Separator (VPS) that dehumidifies the cabin air. The dehumidified air exits the cold-side (CS) VPS chamber to flow into the CO 2 removal module, and the cold, water-laden liquid desiccant flows to a regenerative heat exchanger. From the heat exchanger the liquid desiccant continues to the heater. After heating, the desiccant flows into a hot-desiccant or hot-side (HS) VPS as the dehumidified air from CO 2 removal module enters through the HS VPS air inlet. The rehumidified air exits the HS VPS into the space cabin. One pump installed at the liquid exit of the CS VPS and one pump installed at the liquid exit of the HS VPS transport the fluid through the system. To evaluate the system’s efficiency and effectiveness, the temperature, pressure, flow rate and relative humidity are read, recorded, and analyzed at critical points along the module.

Gerardo Castro

Springtime SEA Air Is Consistently Both Smoky and Humid, but This Relationship (and Its Radiative Effects) Varies Spatially and Seasonally

The atmosphere over the southeast Atlantic Ocean (SEA) sees a consistent springtime biomass burning (BB) smoke from widespread agricultural fires on the African continent. This smoke layer is initially lofted high in a continental mixed layer (~5-6km) and is then transported westward in the free troposphere, where it overlies and ultimately mixes into the SEA stratocumulus-topped oceanic boundary layer. Coincident with this smoke is an elevated humidity signal which is present from the time a given airmass is over the continental source region. ORACLES (ObseRvations of Aerosols above CLouds and their intEractionS) was a NASA Earth Venture Suborbital mission with the goal of measuring aerosol, cloud, and atmospheric properties over this region during three deployments in September 2016, August 2017, and October 2018. A previous study discussed the spatial characteristics of the water vapor-BB plume observations in the September 2016 flight data and their degree of agreement with several atmospheric reanalyses and models. In the present work, we first discuss atmospheric chemistry, structure, and aerosol results from all three ORACLES deployments to place these results in a broader seasonal context. Despite the differing locations and season of each deployment, we show that there continues to be good agreement between the airborne ORACLES dataset and large-scale reanalyses, specifically the ECMWF ERA5 and CAMS reanalyses. Other reanalyses (specifically NASA's MERRA-2) preserved the observed correlation between meteorology and biomass burning conditions, but, as was seen for 2016, was frequently displaced spatially relative to the observations. The CAMS reanalysis performs better with water vapor than with CO. Results comparing CAMS column AOD to the field measurements show slight overestimates, consistent with previous analysis, but the good relationship observed between AOD and inlet-based aerosol extinction demonstrates this metric's utility to broader studies. The good ERA5/CAMS/ORACLES agreement allows us to next examine the multi-year seasonal patterns and trends beyond the three ORACLES deployment periods. Looking at seven years of reanalysis data for the BB season, we find distinct variations between each month/deployment in terms of vertical smoke distribution and correlation to atmospheric specific humidity, due to changing conditions through the BB season. Using k-means clustering of these climatological reanalysis, we identify six canonical atmospheric profile types of varying total atmospheric humidity and vertical structure and describe their changing incidence spatially and throughout the season, and six analogous profile types for carbon monoxide, allowing us to characterize the atmospheric structure of both vapor and BB over time throughout the SEA region. This classification will allow for a more complete analysis of the broader radiative and dynamical effects of humid aerosols overlying stratocumulus clouds.

Kristina Marie Myers Pistone

Relative Humidity Measurement Assurance Program Results

During the summer of 1992, the National Conference of Standards Laboratories sponsored a relative humidity measurement assurance program (RHMAP) whose purpose was to enable each participating center to assess the quality of relative humidity calibrations being performed by their respective standards laboratories. This paper presents the data which was submitted by the participants during the first round of the program and shows the multi-laboratory comparisons of the 20%, 50%, and 80% relative humidity meaurements performed.

Humidity

Humidity Testing of PME and BME Ceramic Capacitors with Cracks

Cracks in ceramic capacitors are one of the major causes of failures during operation of electronic systems. Humidity testing has been successfully used for many years to verify the absence of cracks and assure quality of military grade capacitors. Traditionally, only precious metal electrode (PME) capacitors were used in high reliability applications and the existing requirements for humidity testing were developed for this type of parts. With the advance of base metal electrode (BME) capacitors, there is a need for assessment of the applicability of the existing techniques for the new technology capacitors. In this work, variety of different PME and BME capacitors with introduced cracks were tested in humid environments at different voltages and temperatures. Analysis of the test results indicates differences in the behavior and failure mechanisms for BME and PME capacitors and the need for different testing conditions.

reliability

A 6U CubeSat Constellation for Atmospheric Temperature and Humidity Sounding

We are currently developing a 118/183 GHz sensor that will enable observations of temperature and precipitation profiles over land and ocean. The 118/183 GHz system is well suited for a CubeSat deployment as ~10cm antenna aperture provides sufficiently small footprint sizes (is approx. 25km). This project will enable low cost, compact radiometer instrumentation at 118 and 183 GHz that would fit in a 6U CubeSat with the objective of mass-producing this design to enable a suite of small satellites to image the key geophysical parameters that are needed to improve prediction of extreme weather events. We will take advantage of past and current technology developments at JPL viz. HAMSR (High Altitude Microwave Scanning Radiometer), Advanced Component Technology (ACT'08) to enable low-mass and low-power high frequency airborne radiometers. The 35 nm InP enabling technology provides significant reduction in power consumption (Low Noise Amplifier + Mixer Block consumes 24 mW). In this paper, we will describe the design and implementation of the 118 GHz temperature sounder and 183 GHz humidity sounder instrument on the 6U CubeSat. In addition, a summary of radiometer calibration and retrieval techniques of the temperature and humidity will be discussed. The successful demonstration of this instrument on the 6U CubeSat would pave the way for the development of a constellation consisting of suite of these instruments. The proposed constellation of these 6U CubeSat radiometers would allow sampling of tropospheric temperature and humidity with fine temporal (on the order of minutes) and spatial resolution (is approx. 25 km).

radiometer

Effect of inlet-air humidity on the formation of oxides of nitrogen in a gas-turbine combustor

Tests were conducted to determine the effect of inlet-air humidity on the formation of oxides of nitrogen from a gas-turbine combustor. Combustor inlet-air temperature ranged from 450 F to 1050 F. The tests were run at a constant pressure of 6 atmospheres and reference Mach number of 0.065. The NO sub x emission index was found to decrease with increasing inlet-air humidity at a constant exponential rate of 19 percent per mass percent water vapor in the air. This decrease of NO sub x emission index with increasing humidity was found to be independent of inlet-air temperature.

Marchionna, N. R.

Emissions of an AVCO Lycoming 0-320-DIAD air cooled light aircraft engine as a function of fuel-air ratio, timing, and air temperature and humidity

A carbureted aircraft engine was operated over a range of test conditions to establish the exhaust levels over the EPA seven-mode emissions cycle. Baseline (full rich production limit) exhaust emissions at an induction air temperature of 59 F and near zero relative humidity were 90 percent of the EPA standard for HC, 35 percent for NOx, and 161 percent for CO. Changes in ignition timing around the standard 25 deg BTDC from 30 deg BTDC to 20 deg BTDC had little effect on the exhaust emissions. Retarding the timing to 15 deg BTDC increased both the HC and CO emissions and decreased NOx emissions. HC and CO emissions decreased as the carburetor was leaned out, while NOx emissions increased. The EPA emission standards were marginally achieved at two leanout conditions. Variations in the quantity of cooling air flow over the engine had no effect on exhaust emissions. Temperature-humidity effects at the higher values of air temperature and relative humidity tested indicated that the HC and CO emissions increased significantly, while the NOx emissions decreased.

Meng, P. R.

The dependence of the CO2 removal efficiency of LiOH on humidity and mesh size

The effect of humidity on the CO2 removal efficiency of small beds of anhydrous LiOH has been studied. Experimental data taken in this small bed system clearly show that there is an optimum humidity for beds loaded with LiOH from a single lot. The CO2 efficiency falls rapidly under dry conditions, but this behavior is approximately the same in all samples. The behavior of the bed under wet conditions is quite dependent on material size distribution. The presence of large particles in a sample can lead to rapid fall off in the CO2 efficiency as the humidity increases.

Davis, S. H.

Strain rate, temperature, and humidity on strength and moduli of a graphite/epoxy composite

Results of an experimental study of the influence of strain rate, temperature and humidity on the mechanical behavior of a graphite/epoxy fiber composite are presented. Three principal strengths (longitudinal, transverse and shear) and four basic moduli (E1, E2, G12 and U12) of a unidirectional graphite/epoxy composite were followed as a function of strain rate, temperature and humidity. Each test was performed at a constant tensile strain rate in an environmental chamber providing simultaneous temperature and humidity control. Prior to testing, specimens were given a moisture preconditioning treatment at 60 C. Values for the matrix dominated moduli and strength were significantly influenced by both environmental and rate parameters, whereas the fiber dominated moduli were not. However, the longitudinal strength was significantly influenced by temperature and moisture content. A qualitative explanation for these observations is presented.

Lifshitz, J. M.

Crystal Microbalance Monitors Relative Humidity

Sensor monitors water evaporation in industrial drying processes. Measured adsorption isotherm for instrument essentially linear over entire range of relative humidity. Testing at each temperature setting less than half hour for full relative-humidity range, with estimated frequency response time less than 10 seconds. Used to measure relative humidity of ambient atmosphere near drying paper, food textile fabrics and pulp to optimize water-drying portion of processing cycle.

Yang, L. C.

Determination of monthly mean humidity in the atmospheric surface layer over oceans from satellite data

A simple statistical technique is described to determine monthly mean marine surface-layer humidity, which is essential in the specification of surface latent heat flux, from total water vapor in the atmospheric column measured by space-borne sensors. Good correlation between the two quantities was found in examining the humidity soundings from radiosonde reports of mid-ocean island stations and weather ships. The relation agrees with that obtained from satellite (Seasat) data and ship reports averaged over 2 deg areas and a 92-day period in the North Atlantic and in the tropical Pacific. The results demonstrate that, by using a local regression in the tropical Pacific, total water vapor can be used to determine monthly mean surface layer humidity to an accuracy of 0.4 g/kg. With a global regression, determination to an accuracy of 0.8 g/kg is possible. These accuracies correspond to approximately 10 to 20 W/sq m in the determination of latent heat flux with the bulk parameterization method, provided that other required parameters are known.

Liu, W. T.

How similar are temperature and humidity profiles in the unstable boundary layer?

A comparison was made between temperature and humidity profiles obtained from radiosonde measurements under unstable conditions over hilly terrain in northeastern Kansas during the summer and fall of 1987. The summer profiles were found to be similar in a layer over the height range given by z = 65(plus or minus 45) to 124(plus or minus 54)m, where z is the height above the ground surface reference level. Evidence for this similarity was the closeness of the scaled ratio of the temperature and humidity gradients at any given time to the mean Bowen ratio determined at ground-based surface flux stations. Above the layer, in the outer region of the atmospheric boundary layer, it was found that the profiles of humidity and potential temperature are completely dissimilar in terms of the surface Bowen ratio. The profiles of the fall campaign when soil moisture content was low and vegetation senescent displayed a less pronounced similarity.

Sugita, Michiaki

Recent spectroscopic findings concerning clay/water interactions at low humidity: Possible applications to models of Martian surface reactivity

A feasibility study assessing the utility of the adaptation of near infrared correlation spectroscopy to quantifying iron and adsorbed water in some clay-based Mars soil analog materials (MarSAM's). The work was intended to constitute Phase 1 of an approach to identifying optical analytical wavelength regions, not only for important mineral classes, but for chemically active centers within them. Many of these centers are common to unrelated mineral classes and of disproportionate influence relative to the mineral structure as a whole in determining the surface reactivity of mineral surfaces. We previously reported linearity between reflectance and total iron and total moisture over a large range of both key variables. We also discovered interesting relationships between the intensity of iron bands and the relative humidity of the systems. These relationships were confirmed. We also show that, in the low humidity range, reflectance is linearly dependent on a different kind of water from that best representing the full humidity range (the kind of water associated, in clays, with surface acidity). These relationships and the sensitivity and capability of quantitation of near infrared data indicate high promise with the production of reactive surface intermediates of products of surface reactions.

Coyne, L.

Heat pipes for low-humidity applications

A novel application of an air-to-air heat pipe heat exchanger (HPHX) in a cooling and dehumidification process of an air-conditioning system is described which provides significant energy savings in applications requiring reheat of cold supply air to maintain low humidity. The efficiency of the system has been demonstrated in an application requiring a humidity of 40 percent. The use of the HPHX and fine tuning of the air-conditioning system and controls has resulted in significant energy savings. The technology can be advantageously used in many low-humidity applications commonly encountered in high-tech and aerospace facilities.

Khattar, Mukesh K.

Use of sorption technology for treatment of humidity condensate for potable water

This research focused on the testing of the original potable water processor aboard Space Station Freedom that was to produce potable water from the humidity condensate and additional water generated by carbon dioxide reduction. Humidity condensate was simulated by an influent water model 'Ersatz'. The humidity condensate was treated with multifiltration (MF) beds that consisted of a train of sorption beds (referred to as 'Unibed') designed to remove specific contaminants. For the complete simulated MF system runs tested for 100 bed volumes (BV) (volume processed/total column volume), 0.6 percent of the TOC was removed by the SAC/IRN 77 (Strong Acid Cation exchange resin), 39.6 percent of the total organic carbon (TOC) was removed by the WBA/IRA 68 (Weak Base Anion exchange resin), 13.2 percent of the TOC was removed by activated carbon adsorption (580-26), and the remaining sorbent media acted as polishing units to remove an additional 1.6 percent of the TOC at steady state. At steady state, 45 percent of the influent TOC passed through the MF bed.

Ajjarapu, Sundara R. M.