Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “High operating temperature”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Evaluation of cermet materials suitable for lithium lubricated thrust bearings for high temperature operation

Cerment materials (HfC - 10 wt% W; HfC - 10 wt% TaC - 10 wt%W; HfC - 2 wt% CbC - 8 wt% Mo;Hfn - 10 wt% W; Hfn - 10 wt% TaN - 10 wt% W; and ZrC - 17 wt% W) were evaluated for possible use as lithium-lubricated bearings in the control system of a nuclear reactor. Tests of compatibility with lithium were made in T-111 (Ta-8W-2Hf) capsules at temperatures up to 1090 C. The tendencies of HfC-TaC-W, HfC-CbC-Mo, and HfN-W to bond to themselves and to the refractory alloys T-111 and TZM when enclosed in lithium-filled capsules under a pressure of 2000 psi at 980 and 1200 C for 1933 hours were evaluated. Thermal expansion characteristics were determined for the same three materials from room temperature to 1200 C. On the basis of these tests, HfC-10 TaC-10W and HfN-10W were selected as the best and second best candidates, respectively, of the materials tested for the bearing application.

Sinclair, J. H.↗

Passive components for high temperature operation

The development of resistors, capacitors, and interconnect metalizations utilizing a low pressure chemical vapor deposition (LPCVD) process is described. The LPCVD process allows the passive components to be fabricated at temperatures higher than their highest operating temperatures. The deposition of thin films by LPCVD is accomplished by reacting one or more gases on the surface of a heated substrate. The substrates to be coated are placed on a graphite susceptor and then loaded into the center of a quartz reaction tube. The RF power is applied to the coil on the outside of the reaction tube which in turn is coupled into the graphite susceptor causing it to heat. Pressures of several torr or less are typical, with carrier flow rates of 0.1 to 2.0 liters/min. Nitrogen, hydrogen, and helium are typical carrier gases. These are controlled with mass flow controllers and the pressure is continuously monitored with a capacitive manometer. Materials selection and device testing are also discussed.

Raymond, L. S.↗

Evaluation of crystal oscillators and frequency dividers for high temperature operation

Active and passive components of crystal oscillators and frequency dividers were tested to determine their performance at temperatures from 300 C to 350 C. The properties of GaAs JFETs were determined and their performance compared with that of silicon devices. Techniques for constructing breadboard circuits were assessed for operation in this temperature range. A Pierce oscillator and a multivibrator (Colorado crystal) oscillator were constructed and tested. Device failures are discussed.

Source record↗

High Operating Temperature Barrier Infrared Detector with Tailorable Cutoff Wavelength

A barrier infrared detector with absorber materials having selectable cutoff wavelengths and its method of manufacture is described. A GaInAsSb absorber layer may be grown on a GaSb substrate layer formed by mixing GaSb and InAsSb by an absorber mixing ratio. A GaAlAsSb barrier layer may then be grown on the barrier layer formed by mixing GaSb and AlSbAs by a barrier mixing ratio. The absorber mixing ratio may be selected to adjust a band gap of the absorber layer and thereby determine a cutoff wavelength for the barrier infrared detector. The absorber mixing ratio may vary along an absorber layer growth direction. Various contact layer architectures may be used. In addition, a top contact layer may be isolated into an array of elements electrically isolated as individual functional detectors that may be used in a detector array, imaging array, or focal plane array.

Ting, David Z.↗

State-of-the-art Thin Film Electrolytes For Solid Oxide Fuel Cells

State-of-the-Art solid oxide fuel cells (SOFC) are amongst the main candidates for clean energy technology due to their high efficiency, fuel flexibility, low air pollution, and minimal greenhouse gas emission. However, high operational temperature of SOFC is a greater challenge in commercialization these devices for low cost and portable applications. High temperature operation of SOFC degrades its performance with aging, limits the selection of materials for fuel cell components, and increases the fabrication cost. Thus, there have been enormous efforts to improve the properties of existing materials and develop new materials for SOFC components in order to lower the operating temperature of SOFC. Recent advances in thin film technology have also been utilized to develop new materials with improved properties for SOFC. One of the key components in SOFC is the electrolyte and several research groups are working on developing new electrolyte materials. In this chapter, we will discuss the recent advances in thin film SOFC electrolytes. This extensive discussion includes the evolution of doped ceria, doped zirconia, and multilayer hetero-structured thin film electrolytes. The newly developed nanoscale thin films and multi-layer hetero-structures with improved oxygen ionic conductivity will have significant impact on SOFC devices.

Thevuthasan, Suntharampillai↗

Electron-Phonon Renormalization in the Proton-Conducting Electrolyte Ba Zr O 3 and Its Implications for High-Temperature Electrolysis

Electrical leakage is an inherent problem in solid-oxide fuel and electrolyzer cells, limiting their energy-conversion efficiency. High concentrations of electrons or holes can exacerbate this issue. However, it is largely unclear how the typical high operating temperatures of the systems influence their charge-carrier concentrations. In this work, we use first-principles calculations to examine how lattice vibrations impact electrical conductivity in conventional electrolytes, using Ba Zr O 3 as a representative material. Our analysis shows that phonon-induced shifts in the band gap and band edges lead to a dramatic increase in p -type carrier concentrations at temperatures above 600 K, compared to models that neglect temperature effects. Additionally, we reveal the importance of oxygen-ion motion on band-edge positions, which makes valence-band-edge shift dominate the band-gap change. Our study provides a protocol for calculating phonon-induced changes in similar oxides, paving the way for interrogating electrical leakage in electrolytes for high-temperature operation. Published by the American Physical Society 2025

25 ENERGY STORAGE↗

"Application of Tunable Diode Laser Spectrometry to Isotopic Studies for Exobiology"

Computer-controlled electrically-activated valves for rapid gas-handling have been incorporated into the Stable Isotope Laser Spectrometer (SILS) which now permits rapid filling and evacuating of the sample and reference gas cells, Experimental protocols have been developed to take advantage of the fast gas handling capabilities of the instrument and to achieve increased accuracy which results from reduced instrumental drift during rapid isotopic ratio measurements. Using these protocols' accuracies of 0.5 del (0.05%) have been achieved in measurements of 13C/12C in carbon dioxide. Using the small stable isotope laser spectrometer developed in a related PIDDP project of the Co-I, protocols for acquisition of rapid sequential calibration spectra were developed which resulted in 0.5 del accuracy also being achieved in this less complex instrument. An initial version of software for automatic characterization of tunable diode lasers has been developed and diodes have been characterized in order to establish their spectral output properties. A new state-of-the-art high operating temperature (200 K) mid infrared diode laser was purchased (through NASA procurement) and characterized. A thermo-electrically cooled mid infrared tunable diode laser system for use with high temperature operation lasers was developed. In addition to isotopic ratio measurements of carbon and oxygen, measurements of a third biologically important element (15N/14N in N2O gas) have been achieved to a preliminary accuracy of about 0.2%. Transfer of the basic SILS technology to the commercial sector is proceeding under an unfunded Space Act Agreement between NASA and SpiraMed, a medical diagnostic instrument company. Two patents have been issued. Foreign patents based on these two US patents have been applied for and are expected to be issued. A preliminary design was developed for a thermo-electrically cooled SILS instruments for application to planetary space flight exploration missions.

Sauke, Todd B.↗