Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HfC”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

42 records · Page 3

La Reduccion Gradual de Refrigerantes de Hidrofluorocarburos y el Acondicionamiento de Espacios Comerciales: Guia para la Transicion

You may be aware of the hydrofluorocarbon (HFC) phasedown, but the details and its impact on your operations may still be unclear. Or perhaps this is the first you're hearing about the phasedown. In either case, this guide provides information to aid conversations with facility managers and engineers and provides an explanation of how the phasedown affects equipment in commercial buildings. It also includes actions you and your organization can take now to properly plan and prepare. This is the Spanish translation of NREL/FS-5500-85155: The Hydrofluorocarbon Phasedown and Commercial Space Conditioning: A Guide to the Transition.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Thermal-hydraulic Performance of Emerging Low GWP Refrigerant Mixture under Flow Boiling in Brazed Plate Heat Exchangers

The hydrofluorocarbon (HFC) refrigerants used in the current refrigeration systems are facing a phase-down due to their higher greenhouse effect resulting in global warming, and thus HVAC&R industry has undergone a transition to low Global Warming Potential (GWP) refrigerants. Refrigerant mixtures are attractive alternatives since their composition can be tailored to comply with environmental regulations while preserving favorable thermophysical properties. However, the new low-GWP zeotropic mixture refrigerants have two or more components with different saturation temperatures at the same pressure level, known as temperature glide, which can cause the degradation of the overall heat transfer performance. The brazed plate heat exchangers (BPHX) provide excellent heat transfer performance due to a compact design and are used in several air-conditioning and refrigeration applications. In this study, flow boiling heat transfer and the associated pressure drop of the refrigerant mixture in a vertical BPHX were experimentally investigated. The single-phase water-to-water experiments were conducted in the tested heat exchanger with a counter-flow configuration. The flow boiling experiments charged with R-134a and R-454C were then performed in a pumped refrigerant loop to evaluate its thermal-hydraulic performance. Furthermore, parametric studies of various heat fluxes, mass fluxes, vapor qualities, and saturation temperatures were also conducted.

Yang, Cheng-Min↗

Microchannel Geometries for Improved Heat Transfer with Low-GWP refrigerants

Due to efforts aimed at decarbonizing industries, the use of refrigerants with low global warming potential (GWP) is highly recommended in the air-conditioning and refrigeration sectors. Despite possessing low-GWP values of less than 150, hydrofluoroolefins (HFO) exhibit relatively lower heat transfer performance compared to conventional hydrofluorocarbons (HFC) under certain operating conditions. In contrast to HFCs, there is a high demand for enhanced surfaces to meet the needs of heat transfer systems utilizing low GWP refrigerants. Accordingly, this study analyzes the pool boiling performance of low-GWP refrigerants in microchannel geometries. The experiments were carried out at various heat flux levels on both smooth and enhanced surfaces. The pool boiling behavior of low-GWP refrigerant R1234yf was compared to that of R-134a refrigerant in terms of heat transfer coefficient and wall superheat. The results indicate that the heat transfer coefficients of the enhanced surface are significantly higher than those of the smooth surface. Furthermore, the microchannel geometry demonstrated a lower wall superheat compared to the smooth surface. Additionally, a visualization study was performed using a high-speed camera to understand the pool boiling mechanism of low-GWP refrigerants on both smooth and enhanced surfaces.

Murugan, Muneeshwaran↗

SARS-CoV-2 variant nanobodies and constructs comprising such nanobodies

A large and highly diverse nanobody library was constructed and screened against multiple variants of SARS-COV-2 to find nanobodies with high sensitivity and specificity for the variants. Four rounds of positive selection against a panel of six diverse SARS-COV-2 variant RBDs was performed with our high-diversity. At least 59 of these nanobodies were found to work well against Alpha, Beta, Gamma, Delta, Kappa, Lambda and Mu with some overlap efficacy against other variants. These nanobodies have efficacy as stand-alone nanobodies and as a construct comprising nanobodies linked to the human IgG1 constant fragment (Fc) (nanobody-hFc constructions or nb-hFcs) to make enhanced humanized sdAbs with all the attributes of nanobodies with improved half-life and optimized effector functions. Several promising nanobodies that neutralize the original SARS-COV-2 and several of its variants have been identified, including Delta, with high efficacy. In particular, a subset of these nanobodies bind to the Omicron RBD.

Harmon, Brooke Nicole↗

In-situ measurements of chemically and radiatively important atmospheric gases from the Advanced Global Atmospheric Gas Experiment (AGAGE) and affiliated stations.

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found at the AGAGE home page: https://agage.mit.edu/instruments.Compared to the previous version (https://data.ess-dive.lbl.gov/view/doi:10.3334/CDIAC/ATG.DB1001), the latest update (Agage_gcmd_gcms_data_2021_04_07_tar.gz) includes 6 months of new data through the end of March 2020. Two new compounds, HCFC-132b, and HCFC-133a, are also included in this version. For a complete list of released compounds and used standard scales, please see “AGAGE_scale_2021_v1.pdf” file. Additional information can also be found on the AGAGE website (https://agage.mit.edu).

54 ENVIRONMENTAL SCIENCES↗

The Advanced Global Atmospheric Gases Experiment (AGAGE) Data

In the ALE/GAGE/AGAGE global network program, continuous high frequency gas chromatographic measurements of four biogenic/anthropogenic gases (methane, CH4; nitrous oxide, N2O; hydrogen, H2; and carbon monoxide, CO) and several anthropogenic gases that contribute to stratospheric ozone destruction and/or to the greenhouse effect have been carried out at five globally distributed sites for several years. The program, which began in 1978, is divided into three parts associated with three changes in instrumentation: the Atmospheric Lifetime Experiment (ALE), which used Hewlett Packard HP5840 gas chromatographs; the Global Atmospheric Gases Experiment (GAGE), which used HP5880 gas chromatographs; and the present Advanced GAGE (AGAGE). AGAGE uses two types of instruments: a gas chromatograph with multiple detectors (GC-MD), and a gas chromatograph with mass spectrometric analysis (GC-MS). Beginning in January 2004, an improved cryogenic preconcentration system (Medusa) replaced the absorption-desorption module in the GC-MS systems at Mace Head and Cape Grim; this provided improved capability to measure a broader range of volatile perfluorocarbons with high global warming potentials. The Medusa GC-MS systems were subsequently used at other AGAGE stations (Trinidad Head, Barbados, American Samoa, Zeppelin, Jungfraujoch, and Goan) after the initial setup at Mace Head and Cape Grim. More information may be found at the AGAGE home page: https://agage.mit.edu/instruments.Compared to the previous version (https://data.ess-dive.lbl.gov/datasets/doi: doi:10.15485/1781803), the latest update (Agage_gcmd_gcms.data.2022_01_03.tar.gz) includes 6 months of new data through the end of September 2020. For a complete list of released compounds and used standard scales, please see “AGAGE_scale_2021_v1.pdf” file. Additional information can also be found on the AGAGE website (https://agage.mit.edu).

54 ENVIRONMENTAL SCIENCES↗