Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heating”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

It's the Heat AND the Humidity -- Assessment of Extreme Heat Scenarios to Enable the Assessment of Climate Impacts on Public Health

In the United States, extreme heat is the most deadly weather-related hazard. In the face of a warming climate and urbanization, which contributes to local-scale urban heat islands, it is very likely that extreme heat events (EHEs) will become more common and more severe in the U.S. In a NASA-funded project supporting the National Climate Assessment, we are providing historical and future measures of extreme heat to enable assessments of the impacts of heat on public health over the coterminous U.S. We use atmospheric temperature and humidity information from meteorological reanalysis and from Global Climate Models (GCMs) to provide data on past and future heat events. The project s emphasis is on providing assessments of the magnitude, frequency and geographic distribution of extreme heat in the U.S. to facilitate public health studies. In our approach, long-term climate change is captured with GCM output, and the temporal and spatial characteristics of short-term extremes are represented by the reanalysis data. Two future time horizons, 2040 and 2090, are the focus of future assessments; these are compared to the recent past period of 1981-2000. We are characterizing regional-scale temperature and humidity conditions using GCM output for two climate change scenarios (A2 and A1B) defined in the Special Report on Emissions Scenarios (SRES). For each future period, 20 years of multi-model GCM output have been analyzed to develop a heat stress climatology based on statistics of extreme heat indicators. Differences between the two future and past periods have been used to define temperature and humidity changes on a monthly time scale and regional spatial scale. These changes, combined with hourly historical meteorological data at a spatial scale (12 km) much finer than that of GCMs, enable us to create future climate realizations, from which we compute the daily heat stress measures and related spatially-specific climatological fields. These include the mean annual number of days above certain thresholds of maximum and minimum air temperatures, heat indices and a new heat stress variable that gives an integrated measure of heat stress (and relief) over the course of a day. Comparisons are made between projected (2040 and 2090) and past (1990) heat stress statistics. All output is being provided at the 12 km spatial scale and will also be aggregated to the county level, which is a popular scale of analysis for public health researchers. County-level statistics will be made available by our collaborators at the Centers for Disease Control and Prevention (CDC) via the Wide-ranging Online Data for Epidemiologic Research (WONDER) system. CDC WONDER makes the information resources of the CDC available to public health professionals and the general public. This addition of heat stress measures to CDC WONDER will allow decision and policy makers to assess the impact of alternative approaches to optimize the public health response to EHEs. It will also allow public health researchers and policy makers to better include such heat stress measures in the context of national health data available in the CDC WONDER system. The users will be able to spatially and temporally query public health and heat-related data sets and create county-level maps and statistical charts of such data across the coterminous U.S.

Crosson, William L↗

Low-cost crushed-rock heat storage with oil or salt heat transfer

The demand for variable electricity and heat is met by fossil-fuel power plants because the power plant capital costs and the cost of storing fossil fuels are low. A low-carbon economy requires replacement of the storage function of fossil fuels to provide variable heat and electricity as needed. The Crushed Rock Ultra-large Stored Heat (CRUSH) system is a new technology with the goal to provide heat storage at an incremental capital cost of $2–4/kWh at scales of 10 s to 100 s of GWhs that enables economic daily to multi-week storage. CRUSH can be coupled to nuclear power plants, concentrated solar power (CSP) plants and thermal energy batteries to provide variable electricity and heat on demand. Sensible heat is stored in crushed rock—the lowest-cost heat-storage material. Heat is transferred to and from the crushed rock using nitrate salt or heat-transfer oils but these fluids do not store heat. Heat from a nuclear reactor, CSP plant or conversion of low-price electricity into heat is used to heat the salt or oil. The hot fluid is poured over the crushed rock, trickles downward by gravity through the rock, heats the rock and is collected by the drain pans under the crushed rock. To recover heat cold salt or oil is poured over hot crushed rock, trickles down by gravity while being heated and is collected by the drain pans under the crushed rock. The system design and engineering trade-offs are described. The technology is in the early stages of development.

20 FOSSIL-FUELED POWER PLANTS↗

Modeling heat transport processes in enhanced geothermal systems: Validation study from EGS Collab Experiment 1

Heat recovery from enhanced geothermal systems (EGS) is a complex process involving heat transport in both fracture networks and rock formations. A comprehensive understanding of and the ability to model the underlying heat transport mechanisms is important for the success of EGS but remains challenging in practice due to the generally insufficient characterization of EGS reservoirs. In the present study, we analyze an extensively monitored intermediate-scale EGS field experiment performed in a well-characterized testbed. The high-resolution, high-quality measurements from the field experiment enable the development of a high-fidelity model incorporating a well-constrained fracture network. Based on the field experiment, we investigate the complex heat transport processes in an EGS-relevant environment and validate the capability of a numerical approach in simulating these inherently coupled heat transport processes. A series of numerical simulations were performed to study the effects of different heat transport mechanisms, including thermal convection with fracture flow, thermal conduction in rock formations, and the Joule-Thomson effect. The agreement of thermal responses between field measurements and simulation results indicates that our numerical approach can appropriately model the heat transport processes pertaining to heat recovery from EGS reservoirs.

Wu, Hui↗

Linking Excessive Heat with Daily Heat-Related Mortality over the Coterminous United States

In the United States, extreme heat is the most deadly weather-related hazard. In the face of a warming climate and urbanization, which contributes to local-scale urban heat islands, it is very likely that extreme heat events (EHEs) will become more common and more severe in the U.S. This research seeks to provide historical and future measures of climate-driven extreme heat events to enable assessments of the impacts of heat on public health over the coterminous U.S. We use atmospheric temperature and humidity information from meteorological reanalysis and from Global Climate Models (GCMs) to provide data on past and future heat events. The focus of research is on providing assessments of the magnitude, frequency and geographic distribution of extreme heat in the U.S. to facilitate public health studies. In our approach, long-term climate change is captured with GCM outputs, and the temporal and spatial characteristics of short-term extremes are represented by the reanalysis data. Two future time horizons for 2040 and 2090 are compared to the recent past period of 1981- 2000. We characterize regional-scale temperature and humidity conditions using GCM outputs for two climate change scenarios (A2 and A1B) defined in the Special Report on Emissions Scenarios (SRES). For each future period, 20 years of multi-model GCM outputs are analyzed to develop a 'heat stress climatology' based on statistics of extreme heat indicators. Differences between the two future and the past period are used to define temperature and humidity changes on a monthly time scale and regional spatial scale. These changes are combined with the historical meteorological data, which is hourly and at a spatial scale (12 km) much finer than that of GCMs, to create future climate realizations. From these realizations, we compute the daily heat stress measures and related spatially-specific climatological fields, such as the mean annual number of days above certain thresholds of maximum and minimum air temperatures, heat indices, and a new heat stress variable developed as part of this research that gives an integrated measure of heat stress (and relief) over the course of a day. Comparisons are made between projected (2040 and 2090) and past (1990) heat stress statistics. Outputs are aggregated to the county level, which is a popular scale of analysis for public health interests. County-level statistics are made available to public health researchers by the Centers for Disease Control and Prevention (CDC) via the Wide-ranging Online Data for Epidemiologic Research (WONDER) system. This addition of heat stress measures to CDC WONDER allows decision and policy makers to assess the impact of alternative approaches to optimize the public health response to EHEs. Through CDC WONDER, users are able to spatially and temporally query public health and heat-related data sets and create county-level maps and statistical charts of such data across the coterminous U.S.

Quattrochi, Dale A.↗

Heat Analysis Manager (HAM), a Thermal Desktop API Based Heat Map Generation Software

Thermal engineers often create custom heat maps to analyze their thermal model. However, generating a heat map is difficult because thermal simulation only readily provide attributes of simulated nodes such as temperature, capacitance, heat generation, and a network of conductances. Heat flow values are a derived quantity from the nodal attributes, and the data processing and management of heat flow between nodes quickly become difficult for large models. Deriving a network of heat flow values requires vast amount of calculations and data handling, heat map generation process generally suffers from processing speed, loss of accuracy, and/or presentation of data in a useful format. Heat Analysis Manager (HAM) is a Thermal Desktop (TD) based free multi-purpose tool developed to aid thermal engineers in analyzing their thermal model, including a heat map generation functionality. HAM’s heat map generator retains accuracy and fast processing speed by utilizing TD’s application programming interface (API) and built-in TD’s “Qflow from Results.” Furthermore, HAM’s heat map output is presented in an easily customizable format in Excel, allowing users to create various custom visual heat maps. A full description of how HAM utilizes TD’s API to create a customizable heat map is provided. A simple model demonstration is included along with step-by-step procedures on creating custom heat maps. HAM’s heat map result has been verified against TD’s and other heat map generation software, and verification methods are also included.

Thermal desktop↗

Hybrid Heat Pump Controls: Conventional Dual Fuel versus Seamlessly Fuel Flexible Heat Pump

This paper compares the performance of a novel seamlessly fuel flexible heat pump (SFFHP) and conventional dual fuel heat pump (DFHP) for space heating. The conventional dual fuel systems either run on the gas furnace or electric heat pump at any given moment, as a comparison, the proposed seamlessly fuel flexible heat pump simultaneously consumes gas and electricity by continuously optimizing the proportion of each. The process air flows across the heat pump condenser first and then flows across the furnace coil, therefore, the heat pump temperature lift is reduced. SFFHP delivers energy savings by allowing each subsystem, i.e., gas furnace and electric heat pump, to operate where it performs best.For DFHP, two operation control strategies, i.e., non-restricted control and restricted control, are available on market. For the non-restricted mode, the thermostat has a switching temperature-programmed according to the balancing point of heating load and capacity curve. Heat pump operates above the switching temperature, while the furnace takes over under the switching temperature. For the restricted control, the compressor of a heat pump is disabled below a predefined lockout outdoor temperature to let the furnace take over. For SFFHP, a model predictive control strategy is developed to continuously adjust the capacities of the electric heat pump and gas furnace based on the foreseen weather data, utility price signals, and marginal grid emission signals with the goal of minimizing the utility cost and CO2 emission while guaranteeing comfort requirements.In this paper, DFHP and SFFHP are simulated using high-fidelity heat pump performance curves generated from DOE/ORNL heat pump design model. Performance comparison of DFHP and SFFHP during 2019-2020 heating season in Los Angeles shows that SFFHP with model predictive control achieves 23% utility cost reduction and 17 % CO2 emission reduction. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. As a result, SFFHP can deliver superior benefits for utility cost reduction and CO2 emission reduction over conventional dual fuel heat pump.

Li, Zhenning↗

Superhydrophobic heat exchangers delay frost formation and enhance efficency of electric vehicle heat pumps

The number of electric vehicles has rapidly expanded as high-performance automotive lithium-ion batteries have become more affordable. However, the range of electric vehicles decreases in cold climates partly because of the additional thermal loads associated with cabin heating. One way to improve the efficiency of cabin heating is to replace resistive heating elements with an air-source heat pump system. However, to gain the full benefit of heat pumping, frost formation on the outdoor heat exchanger must be minimized. In this work, we modified the surface wettability of aluminum louvered-fin automotive heat pump evaporators and tested them under realistic operating conditions in a transcritical carbon dioxide (CO 2 ) heat pump. Each heat exchanger underwent several consecutive frosting and defrosting cycles to understand the cyclic performance of the system. The heat exchanger with a superhydrophobic outer surface was able to delay frost formation and maintain higher heat transfer rates when compared to heat exchangers with higher surface energies (hydrophilic). The delayed frost formation resulted in a system efficiency benefit in the first few frosting cycles but diminished in later cycles due to water retention and incomplete defrosting. However, for most automotive applications the superhydrophobic heat exchanger showed substantial benefits for normal driving trips. We report the scalable and optimized superhydrophobic heat exchangers developed here have the potential to increase the efficiency of automotive heat pumps and consequently increase the range and reduce energy consumption of electric vehicles.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

3D modeling of n = 1 RMP driven heat fluxes on the SPARC tokamak PFCs using HEAT

3D heat flux calculations at the lower outer divertor plate of SPARC using the HEAT code show that 3D fields generated from error field correction coils can lead to enhanced peak heat fluxes up to 15 times larger compared to the axisymmetric case. Previously employed to simulate axisymmetric heat flux on 3D plasma facing components, the HEAT code can now predict 3D heat flux generated by non-axisymmetric plasmas. This is achieved via a new HEAT module which leverages the 3D field line tracing capabilities of MAFOT starting from an M3D-C1 (MHD resistive code) perturbed equilibria. The resulting heat flux is assigned using the magnetic footprint and the heat flux layer model, an extension of the 2D heat flux model also known as the Eich, to 3D non-axisymmetric plasmas. For SPARC, the new capabilities of HEAT are used to calculate the 3D heat loads resulting from n = 1 perturbation fields (with n indicating the toroidal periodicity) applied through a toroidal array of six picture frame coils with different amplitude. The comparison with the unperturbed case shows significant changes in shape and intensity of the heat flux profile. The results show that the application of n = 1 3D field leads to a localized enhancement of the heat flux peak, influenced by the wetted area impacted by the magnetic footprint, and the appearance of a secondary heat flux peak, whose intensity depends on amplitude of the applied 3D field and toroidal location.

3D heat flux↗

Heat Transfer Characteristics of Particle and Air Flow Through Additively Manufactured Lattice Frame Material Based on Octet-Shape Topology

Particle-to-supercritical carbon dioxide (sCO 2 ) heat exchanger is a critical component in next-generation concentrating solar power (CSP) plants. The inherently low heat transfer between falling particles and sCO 2 imposes a challenge toward economic justification of levelized cost of electricity produced through solar energy. Introduction of integrated porous media with the walls bounding particle flow has the potential to enhance the overall particle-to-sCO 2 heat exchanger performance. Here, this paper presents an experimental study on heat transfer characterization of additively manufactured lattice frame material based on Octet-shaped unit cell with particles and air as working fluids. The lattice structures were additively manufactured in stainless steel (SS) 316L and SS420 (with 40% bronze infiltration) via Binder jetting process, where the lattice porosities were varied between 0.75 and 0.9. The mean particle diameters were varied from 266 μm to 966 μm. The effective thermal conductivity and averaged heat transfer coefficient were determined through steady-state experiments. It was found that the presence of lattice enhances the effective thermal conductivity by 2–4 times when compared to packed bed of particles alone. Furthermore, for gravity-assisted particle flow through lattice panel, significantly high convective heat transfer coefficients ranging from 200 W/m2K to 400 W/m2K were obtained for the range of particle diameters tested. The superior thermal transport properties of Octet-shape-based lattice frame for particle flow makes it a very promising candidate for particle-to-sCO 2 heat exchanger for CSP application.

14 SOLAR ENERGY↗

Hybrid Solar Thermal Energy System for District Heating Application

Solar district heating (SDH) systems can be good alternatives to conventional systems when they are optimized with hybrid configurations and thermal energy storage (TES). In this scope, a hybrid renewable thermal energy system (RTES) model has been built combining flat plate collector (FPC) solar system with parabolic trough collector (PTC) system via a heat exchanger and coupled with TES. To undertake the hybridization of the system, System Advisor Model (SAM) software was modified, which allowed control over configurations and more accurate modelling of heat transfer between the collectors. The model is first compared to an existing hybrid solar district heating systems (DHS) system in Taars, Denmark. The results showed a good correlation with an overestimation of only 6.4% compared to most recent heat output. Then the same system configuration was modeled in different geographic locations to investigate the impact of changes in direct normal irradiance (DNI) to the heat sink thermal output of the hybrid system. The results showed that the annual net thermal power output in California, USA can be three times more than the annual net thermal power output in Taars, Denmark. Finally, multiple hybrid configurations with varying solar field sizes were simulated based on the heat demand of two different university campuses DHS. The results showed that, retrofit applications of this hybrid DHS system coupled with TES could reduce the natural gas consumption of the existing systems between 25% and 41%. The use of hybrid RTES highlighted in this paper can be extended to many more opportunities.

district heating↗

Redefining fuel heating value for engines: Accounting for heat of vaporization

Defining a fuel's heating value (i.e., energy content) is fundamental for calculating engine efficiency and for life cycle analysis comparisons between different fuels. Traditional definitions of lower heating value and higher heating value account for the effect of water vapor versus liquid water in the exhaust, which is important when the fuel is used in a furnace or boiler. In an engine, it is equally important to properly account for the energy required to vaporize liquid fuel. Heat of vaporization has a small effect for common hydrocarbon fuels, typically less than 1% of lower heating value, but the effect is much larger for other important fuels such as ethanol (3.4% of lower heating value) and methanol (5.9% of lower heating value). This paper defines a new type of fuel heating value that more accurately reflects the useful fuel energy content for engines. Vaporized heating value is defined as the heating value when starting with a vaporized fuel instead of a liquid fuel. It can be calculated by adding the fuel's heat of vaporization to the traditional lower heating value. This paper illustrates the rationale and benefits of using vaporized heating value using data from the literature.

09 BIOMASS FUELS↗

Chronically underestimated: a reassessment of US heat waves using the extended heat index

Abstract The heat index, or apparent temperature, was never defined for extreme heat and humidity, leading to the widespread adoption of a polynomial extrapolation designed by the United States National Weather Service. Recently, however, the heat index has been extended to all combinations of temperature and humidity, presenting an opportunity to reassess past heat waves. Here, three-hourly temperature and humidity are used to evaluate the extended heat index over the contiguous United States during the years 1984–2020. It is found that the 99.9th percentile of the daily maximum heat index is highest over the Midwest. Identifying and ranking heat waves by the spatially integrated exceedance of that percentile, the Midwest once again stands out as home to the most extreme heat waves, including the top-ranked July 2011 and July 1995 heat waves. The extended heat index can also be used to evaluate the physiological stress induced by heat and humidity. It is found that the most extreme Midwest heat waves tax the cardiovascular system with a skin blood flow that is elevated severalfold, approaching the physiological limit. These effects are not captured by the National Weather Service’s polynomial extrapolation, which also underestimates the heat index by as much as 10 ∘ C (20 ∘ F) during severe heat waves.

54 ENVIRONMENTAL SCIENCES↗

High heat flux single phase heat exchanger

This paper presents the results obtained to date in a program to develop a high heat flux, single-phase heat exchanger for spacecraft thermal management. The intended application is a net generation interface heat exchanger to couple the crew module water thermal bus to the two-phase ammonia main thermal bus in the Space Station Freedom. The large size of the interface heat exchanger is dictated by the relatively poor water-side heat transfer characteristics. The objective of this program is to develop a single-phase heat transfer approach which can achieve heat fluxes and heat transfer coefficients comparable to those of the evaporation ammonia side. A new heat exchanger concept has been developed to meet these objecties. The main feature of this heat exchanger is that it can achieve very high heat fluxes with a pressure drop one to two orders of magnitude lower than those of previous microchannel or jet impingement high heat flux heat exchangers. This paper describes proof-of-concept experiments performed in air and water and presents analytical model of the heat exchanger.

Valenzuela, Javier A.↗

Loop Heat Pipe Operation Using Heat Source Temperature for Set Point Control

The LHP operating temperature is governed by the saturation temperature of its reservoir. Controlling the reservoir saturation temperature is commonly accomplished by cold biasing the reservoir and using electrical heaters to provide the required control power. Using this method, the loop operating temperature can be controlled within +/- 0.5K. However, because of the thermal resistance that exists between the heat source and the LHP evaporator, the heat source temperature will vary with its heat output even if LHP operating temperature is kept constant. Since maintaining a constant heat source temperature is of most interest, a question often raised is whether the heat source temperature can be used for LHP set point temperature control. A test program with a miniature LHP has been carried out to investigate the effects on the LHP operation when the control temperature sensor is placed on the heat source instead of the reservoir. In these tests, the LHP reservoir is cold-biased and is heated by a control heater. Tests results show that it is feasible to use the heat source temperature for feedback control of the LHP operation. Using this method, the heat source temperature can be maintained within a tight range for moderate and high powers. At low powers, however, temperature oscillations may occur due to interactions among the reservoir control heater power, the heat source mass, and the heat output from the heat source. In addition, the heat source temperature could temporarily deviate from its set point during fast thermal transients. The implication is that more sophisticated feedback control algorithms need to be implemented for LHP transient operation when the heat source temperature is used for feedback control.

Ku, Jentung↗

Heat Exchanger Design for Waste Heat Recovery using Additive Manufacturing

With anticipated increases in global energy use and their associated emissions, there are many efforts to improve the emissions and efficiency of many industrial processes through waste heat recovery (WHR). To maximize improvements, the heat exchangers in WHR power cycles must be designed and optimized for a given heat source. Meanwhile, additive manufacturing (AM) is a single part manufacturing technique that provides the opportunity to develop unique and complex heat exchanger designs. Consequently, this work centers on the modeling, design, optimization, and testing of AM shell and tube heat exchangers for WHR. Specifically, a modified one-dimensional (1+1-D) and three-dimensional (3-D) heat exchanger models were developed and validated, with the 1+1-D model serving as the basis for design optimization. After modifications to the design to allow for AM, heat exchanger geometry optimizations were completed, targeting increased effectiveness across a range of physical parameters. Of the designs considered, nine were additively manufactured using Ti5553, and then tested using an external heat source and working fluid. Experimentally, the nineteen-tube, zero-baffle heat exchanger displayed the best overall performance, with the effects of dimensional accuracy, surface roughness, and baffles in the other designs also indicated. Next, the experimental results were used as inputs for the 1+1-D model. Although the original model was able to predict fluid outlet temperatures within 5% differences, larger variations in the heat exchanger performance parameters, temperature differences, and pressure drop necessitated optimizing the pressure drop and heat transfer calculations within the model. Thus, the resulting improved model was able to predict the heat transfer rates, heat source temperature difference, and effectiveness within 15% differences, while showing improvements in the pressure drops and working fluid temperature differences. The improved model serves as the foundation for future work to improve the design and performance of AM heat exchangers.

Spickler, Bailey Ann↗

Heat Pipe Heat Exchanger for Nuclear Electric Propulsion Power Conversion System

Heat pipe reactors have been considered by the Space Nuclear Propulsion program for Nuclear Electric Propulsion (NEP) power conversion systems and will require the use of heat exchangers to transfer heat via heat pipes to the Brayton working fluid from the reactor. Sodium (Na) and lithium (Li) were considered as viable working fluids inside the heat pipes which were assumed to have the same geometry based on studies and information from the Los Alamos National Laboratory. The heat exchanger was assumed to be a rectangular duct with heat pipes serving as tubes from previous NEP work and recommendations. Based on this geometry, Zukauskas correlations were used to model the convective heat transfer and pressure losses. Parametric sizing of the reactor component involved operational limits-based heat pipe thermal hydraulic modeling in cohesion with required user input geometry for the in-core lattice and various subcomponents. This work considered various power conversion inlet temperatures (PCIT) of 1100 K, 1150 K, and 1200 K for Na heat pipes and 1100 K, 1150 K, 1200 K, and 1400 K for Li heat pipes based on recommendations from prior work. Using these different PCITs, the subsystem masses and pressure losses were determined and analyzed. Na showed a lower overall operating temperature and about a fifth of the maximum heat throughput capability than that of Li for the same geometry. Due to this, the entire Na-based subsystem ended up being three times more massive than the Li-based subsystem given five times the required number of heat pipes. At the low PCIT of 1100 K, the Na-based subsystem exhibited the lowest pressure losses given the large overall cross sectional flow area and relatively low frictional pressure losses. However, as the PCIT increased, the frictional pressure losses increased resulting in higher pressure losses at the 1200 K PCIT than Li-based subsystem. However, the Li-based subsystem exhibited the largest pressure losses of all analyzed cases at the 1400 K PCIT due to the low density of the Brayton working fluid at this temperature.

electric↗

Dynamic optimization with flexible heat integration of a solar parabolic trough collector plant with thermal energy storage used for industrial process heat

There is an increasing need to reduce fossil fuel consumption used for industrial process heat to slow the effects of climate change. Using solar thermal heat is a viable way to replace fossil fuel use, but solar industrial process heat plants have limited implementation due to large upfront costs and inefficiencies from the inherent variability from solar energy. Having more flexible and optimized control over these plants can enable them to be more efficient. Here in this work, a solar industrial process heat plant with thermal energy storage that can flexibly collect and deliver heat to two industrial processes (flexible heat integration) is dynamically modeled with control setpoints found by a dynamic optimization method. The optimized case can increase the solar efficiency of the plant by 7.5% on average relative to a base case. The results show that it is best to collect heat at lower temperatures for all but ideal solar conditions, only medium to high quality heat should be stored in large quantities, and exchanging heat with a lower temperature heat sink is generally more efficient. The optimized case is able to reduce the levelized cost of heat of the plant to $31.83/MWh th compared to a base case value of $34.10/MWh th . The optimized case can reduce emissions by 22.2% compared to a plant which uses only natural gas. This work shows that dynamic optimization with flexible heat integration can be a cost-effective way to increase efficiency so that more of these types of plants can be implemented.

14 SOLAR ENERGY↗

Thermal Performance of High Temperature Titanium -- Water Heat Pipes by Multiple Heat Pipe Manufacturers

Titanium - water heat pipes are being investigated for use in heat rejection systems for lunar and Mars fission surface power systems. Heat pipes provide an efficient and reliable means to transfer heat to a radiator heat rejection system. NASA Glenn Research Center requisitioned nine titanium water heat pipes from three vendors. Each vendor supplied three heat pipes 1.25 cm diameter by 1.1 meter long with each vendor selecting a different wick design. Each of the three heat pipes is slightly different in construction. Additional specifications for the heat pipes included 500 K nominal operating temperature, light weight, and freeze tolerance. The heat pipes were performance tested gravity-aided, in the horizontal position and at elevations against gravity at 450 K and 500 K. Performance of the three heat pipes is compared. The heat pipe data will be used to verify models of heat pipe radiators that will be used in future space exploration missions.

Sanzi, James L.↗