Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Switch”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

A Bioinspired Artificial Injury Response System Based on a Robust Polymer Memristor to Mimic a Sense of Pain, Sign of Injury, and Healing

Abstract Flexible electronic skin with features that include sensing, processing, and responding to stimuli have transformed human–robot interactions. However, more advanced capabilities, such as human‐like self‐protection modalities with a sense of pain, sign of injury, and healing, are more challenging. Herein, a novel, flexible, and robust diffusive memristor based on a copolymer of chlorotrifluoroethylene and vinylidene fluoride (FK‐800) as an artificial nociceptor (pain sensor) is reported. Devices composed of Ag/FK‐800/Pt have outstanding switching endurance >10 6 cycles, orders of magnitude higher than any other two‐terminal polymer/organic memristors in literature (typically 10 2 –10 3 cycles). In situ conductive atomic force microscopy is employed to dynamically switch individual filaments, which demonstrates that conductive filaments correlate with polymer grain boundaries and FK‐800 has superior morphological stability under repeated switching cycles. It is hypothesized that the high thermal stability and high elasticity of FK‐800 contribute to the stability under local Joule heating associated with electrical switching. To mimic biological nociceptors, four signature nociceptive characteristics are demonstrated: threshold triggering, no adaptation, relaxation, and sensitization. Lastly, by integrating a triboelectric generator (artificial mechanoreceptor), memristor (artificial nociceptor), and light emitting diode (artificial bruise), the first bioinspired injury response system capable of sensing pain, showing signs of injury, and healing, is demonstrated.

36 MATERIALS SCIENCE↗

Data center coolant switch

A data center cooling system has an indoor portion wherein heat is absorbed from components in the data center, and an outdoor heat exchanger portion wherein outside air is used to cool a first heat transfer fluid (e.g., water) present in at least the outdoor heat exchanger portion of the cooling system during a first mode. When an appropriate time has been reached to switch from the first mode to a second mode, the outdoor heat exchanger portion of the data cooling system is switched to a second heat transfer fluid, which is a relatively low performance heat transfer fluid (compared to the first fluid). It has a second heat transfer fluid freezing point, lower than the first heat transfer fluid freezing point, and sufficiently low to operate without freezing when the outdoor air temperature drops below a first predetermined relationship with the first heat transfer fluid freezing point.

Iyengar, Madhusudan Krishnan↗

Data center coolant switch

A data center cooling system has an indoor portion wherein heat is absorbed from components in the data center, and an outdoor heat exchanger portion wherein outside air is used to cool a first heat transfer fluid (e.g., water) present in at least the outdoor heat exchanger portion of the cooling system during a first mode. When an appropriate time has been reached to switch from the first mode to a second mode, the outdoor heat exchanger portion of the data cooling system is switched to a second heat transfer fluid, which is a relatively low performance heat transfer fluid (compared to the first fluid). It has a second heat transfer fluid freezing point, lower than the first heat transfer fluid freezing point, and sufficiently low to operate without freezing when the outdoor air temperature drops below a first predetermined relationship with the first heat transfer fluid freezing point.

Iyengar, Madhusudan K.↗

Turbulent Heating in Collisionless Low-beta Plasmas: Imbalance, Landau Damping, and Electron–Ion Energy Partition

An understanding of how turbulent energy is partitioned between ions and electrons in weakly collisional plasmas is crucial for modeling many astrophysical systems. Using theory and simulations of a four-dimensional reduced model of low-beta gyrokinetics (the “Kinetic Reduced Electron Heating Model”), we investigate the dependence of collisionless heating processes on plasma beta and imbalance (normalized cross-helicity). These parameters are important because they control the helicity barrier, the formation of which divides the parameter space into two distinct regimes with remarkably different properties. In the first, at lower beta and/or imbalance, the absence of a helicity barrier allows the cascade of injected power to proceed to small (perpendicular) scales, but its slow cascade rate makes it susceptible to significant electron Landau damping, in some cases leading to a marked steepening of the magnetic spectra on scales above the ion Larmor radius. In the second, at higher beta and/or imbalance, the helicity barrier halts the cascade, confining electron Landau damping to scales above the steep “transition-range” spectral break, resulting in dominant ion heating. We formulate quantitative models of these processes that compare well to simulations in each regime, and combine them with results of previous studies to construct a simple formula for the electron–ion heating ratio as a function of beta and imbalance. This model predicts a “winner takes all” picture of low-beta plasma heating, where a small change in the fluctuations' properties at large scales (the imbalance) can cause a sudden switch between electron and ion heating.

Interplanetary turbulence↗

Cavity-assisted magnetization switching in a quantum spin-phonon chain

Néel order switching in antiferromagnets has typically required intense optical driving, leading to substantial heating and limited efficiency. By placing antiferromagnets inside a terahertz-driven optical cavity, we propose a multi-particle mechanism for Néel order switching that benefits from reduced heating. Our analysis reveals that phonons are indispensable to this mechanism. A driven cavity mode couples to a spin-phonon chain, with all excitations dissipating energy through external baths. Mean-field analysis shows that cavity photons induce sublattice spin-density imbalance—an intrinsic symmetry-breaking effect absent without the cavity. Contrary to known (1–10 V/nm) laser fields required to switch the Néel order, our mechanism enables switching at remarkably low laser fields (1–5 V/μm), selectively targeting low-energy and perpendicular magnon modes. By virtue of the suppressed heating, the switching remains highly tunable through laser fluence, damping, and photon loss, establishing a low-dissipation route toward cavity-assisted opto-spintronics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Demonstration and characterization of insertable passive thermal switches for dynamic building envelopes

A dynamic building envelope integrated with thermal energy storage, such as phase change material (PCM), is an emerging technology that offers a promising solution to improve the energy efficiency of buildings. This study reports the development of insertable thermal switches, which modulate thermal resistance, thereby making building envelopes dynamic and enhancing the use of free ambient heating and cooling. The reported thermal switches are passive, meaning they work solely based on indoor and outdoor temperatures. A single switch when inserted into 10 × 10-in (0.064-m 2 ) XPS foam board insulation demonstrates effective thermal conductivity of 0.050 W/m-K in the resistive state and 0.285 W/m-K in the conductive state. Thermal switches exhibit an effective switching ratio of 5.7, with no noticeable degradation in performance over 770 cycles. Additionally, when integrated into a wall sample containing a PCM layer, switches significantly reduce the PCM solidification time by 43.2% during the cooling process.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of fluorite-structured ferroelectrics using transmission electron microscopy: Techniques, challenges, and recent advances

Fluorite-structured ferroelectrics, such as hafnium oxide and its alloyed variants, are key candidates for next-generation memory devices. Yet, fundamental questions about switching mechanisms, domain dynamics, and phase evolution remain open. Transmission electron microscopy (TEM) provides unique capabilities to address these challenges by simultaneously resolving the positions of anions and cations, chemical variations, and structural transformations. Recent advances—including in situ heating, electron beam-induced switching, electron energy loss spectroscopy, and differential phase contrast imaging—have revealed critical insights into phase transitions, potential switching pathways, and oxygen vacancy behavior. However, experimental barriers such as TEM sample-preparation-induced artifacts, high coercive fields, and imaging constraints persist, especially for polycrystalline films. By offering a focused overview of current TEM developments in fluorite ferroelectrics, this work outlines how TEM contributes to understanding key phenomena and proposes a roadmap for future studies.

36 MATERIALS SCIENCE↗

Nonlinear electrical transport near the metal–insulator transition in V 4 O 7 thin films

Nonlinear electrical transport associated with correlated electronic states has been widely investigated in transition-metal oxides near metal–insulator transitions. Here, in this study, we investigate nonlinear transport and threshold switching in sputter-deposited V 4 O 7 thin films grown on fused silica substrates. Temperature-dependent transport measurements show a metal–insulator transition near 240 K with negligible thermal hysteresis, defining the temperature scale that governs the nonlinear electrical response. Current–voltage measurements reveal reproducible bipolar threshold switching over a broad temperature range, with the threshold voltage decreasing systematically as the transition temperature is approached. Electrothermal finite-element simulations reproduce the measured switching characteristics and show that switching occurs when localized Joule heating drives a confined region of the device toward the transition temperature. The simulated peak local temperature at threshold lies close to the intrinsic metal–insulator transition temperature of V 4 O 7 , establishing that the nonlinear electrical response originates from electrothermal feedback acting on the strongly temperature-dependent conductivity near the transition. These results identify V 4 O 7 thin films as a model correlated-oxide system in which volatile threshold switching emerges from proximity to an extended metal–insulator transition.

25 ENERGY STORAGE↗

Hybrid Heat Pump Controls: Conventional Dual Fuel versus Seamlessly Fuel Flexible Heat Pump

This paper compares the performance of a novel seamlessly fuel flexible heat pump (SFFHP) and conventional dual fuel heat pump (DFHP) for space heating. The conventional dual fuel systems either run on the gas furnace or electric heat pump at any given moment, as a comparison, the proposed seamlessly fuel flexible heat pump simultaneously consumes gas and electricity by continuously optimizing the proportion of each. The process air flows across the heat pump condenser first and then flows across the furnace coil, therefore, the heat pump temperature lift is reduced. SFFHP delivers energy savings by allowing each subsystem, i.e., gas furnace and electric heat pump, to operate where it performs best.For DFHP, two operation control strategies, i.e., non-restricted control and restricted control, are available on market. For the non-restricted mode, the thermostat has a switching temperature-programmed according to the balancing point of heating load and capacity curve. Heat pump operates above the switching temperature, while the furnace takes over under the switching temperature. For the restricted control, the compressor of a heat pump is disabled below a predefined lockout outdoor temperature to let the furnace take over. For SFFHP, a model predictive control strategy is developed to continuously adjust the capacities of the electric heat pump and gas furnace based on the foreseen weather data, utility price signals, and marginal grid emission signals with the goal of minimizing the utility cost and CO2 emission while guaranteeing comfort requirements.In this paper, DFHP and SFFHP are simulated using high-fidelity heat pump performance curves generated from DOE/ORNL heat pump design model. Performance comparison of DFHP and SFFHP during 2019-2020 heating season in Los Angeles shows that SFFHP with model predictive control achieves 23% utility cost reduction and 17 % CO2 emission reduction. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. As a result, SFFHP can deliver superior benefits for utility cost reduction and CO2 emission reduction over conventional dual fuel heat pump.

Li, Zhenning↗

Sensitivity-based voltage constraints for optimal power flow in low-voltage distribution feeders

The optimal power flow (OPF) problem for distribution systems can include network details down to the low-voltage (LV) points of interconnection of individual customers. This paper addresses the implementation of voltage magnitude constraints, and sets forth a practicable approach for capturing the effects on voltage from the switching behavior of loads (e.g., heat pumps, air conditioners, water heaters, or pool pumps) and from the variability of renewable generation (e.g., rooftop solar). The proposed method adjusts the OPF voltage constraints based on forecasts of load and generation upper and lower bounds, in conjunction with sensitivity factors derived from the power flow equations. An illustrative OPF formulation is also provided, which incorporates transformer models that include core loss. We demonstrate that accurate modeling of these LV network components is critical to avoid voltage violations at customer points of interconnection. Furthermore, the ideas are validated through numerical case studies on a realistic distribution feeder.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Imaging of Electrothermal Filament Formation in a Mott Insulator

Resistive switching—the current- and voltage-induced change of electrical resistance—is at the core of memristive devices, which play an essential role in the emerging field of neuromorphic computing. This study is about resistive switching in a Mott insulator, which undergoes a thermally driven metal-to-insulator transition. Two distinct switching mechanisms are reported for such a system: electric-field-driven resistive switching and electrothermal resistive switching. The latter results from an instability caused by Joule heating. Here, we present the visualization of the reversible resistive switching in a planar V 2 O 3 thin-film device using high-resolution wide-field microscopy in combination with electric transport measurements. We investigate the interaction of the electrothermal instability with the strain-induced spontaneous phase separation in the V 2 O 3 thin film at the Mott transition. The photomicrographs show the formation of a narrow metallic filament with a minimum width ≲500 nm. Although the filament formation and the overall shape of the current-voltage characteristics (IVCs) are typical of an electrothermal breakdown, we also observe atypical effects such as oblique filaments, filament splitting, and hysteretic IVCs with sawtoothlike jumps at high currents in the low-resistance regime. We are able to reproduce the experimental results in a numerical model based on a two-dimensional resistor network. This model demonstrates that resistive switching in this case is indeed electrothermal and that the intrinsic heterogeneity is responsible for the atypical effects. This heterogeneity is strongly influenced by strain, thereby establishing a link between switching dynamics and structural properties.

42 ENGINEERING↗

Quantification of Energy Savings and Demand Reduction for a Heat Pump Integrated with Thermal Energy Storage (Final Report)

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries or installing new peaking power plants. Stakeholders and policy makers across the United States have expressed interests in promoting TES, as demonstrated by the US Department of Energy’s Grid-Interactive Efficient Buildings program and the efforts of various state legislatures. However, the cost value provided by TES are unclear. If reliable cost benefits were determined, stakeholders would have a clearer picture of the financial returns that can be gained from their investment in TES. The study in this report is conducted by ORNL with collaboration with Emerson the Helix Innovation Center. In the first part of this report, EnergyPlus was used to perform whole-building simulations for two residential buildings in Indianapolis and Atlanta. The HVAC system in both buildings were equipped with phase change material TES. The TES tank was charged in off-peak hours and discharged in peak hours to perform load shifting. First, the economic value implied by existing time-of-use (TOU) rates offered by utility companies was analyzed via whole-building simulation. Second, existing demand reduction (DR) incentives sourced from 3 different electrical grid administrators (i.e., California, Texas, and New England region) were surveyed to determine their implied value. The study suggests that the traditional value analysis that focuses on ROI for the building owner significantly undervalues TES technology making economic viability difficult. A more comprehensive value analysis that includes peak demand management and deferred capital for peaking power plants shows that TES should be economically viable but here the value is greater for the utility and requires large market penetration and aggregation to fully realize the benefits. Therefore, to facilitate commercialization, new business models are needed that include a broader range of stakeholders and distribute the value of TES proportionally. In the 2 nd part of this project, the benefits of a novel phase change material (PCM) integrated heat pump configuration were evaluated via detailed component based simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation. To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Simulation of a PCM Integrated Heat Pump Using Time-of-Use Utility Structure based Control Strategy for Demand Response

To mitigate the variation in demand on the electric grid, thermal energy storage (TES) is an alternative to electric batteries and constructing new peaking power plants. The aggressive carbon reduction goals of the United States are accelerating the electrification of building equipment. If space heating and cooling in the US were electrified using conventional heat pump technologies, the winter electric grid peak would approximately double. Integrating TES with heat pump (HP) enables electrification of space cooling and heating devices without overtaxing the grid.This paper evaluates the benefits of a novel phase change material (PCM) integrated heat pump configuration via simulation. A one-dimensional PCM heat exchanger model which discretizes the PCM tank and refrigerant tubes into small control volumes is developed. Each control volume can have different PCM temperatures, PCM properties, and heat transfer coefficients. The PCM tank is charged by a wrapped tank condenser and discharged by an internal refrigerant coil. The PCM heat exchanger model is integrated into DOE/ORNL Heat Pump Design Model for heat pump system simulation.To demonstrate the performance of the PCM integrated heat pump, a case study in Chicago was performed. A Time-of-Use utility structure-based control strategy is implemented to schedule the PCM tank charging and discharging mode switching. Compared with a conventional electric heat pump, the PCM integrated heat pump shows superior performance on load shifting and utility cost reduction. As a result, the proposed system demonstrates 24.6% utility saving for cooling application and 25.8% utility saving for heating application.

Li, Zhenning↗

Converter-Interfaced CHP Plant for Improved Grid-Integration, Flexibility and Resiliency

GE Research and its partner GE Renewables have proposed the use of an interface converter solution to increase the penetration of small to medium-sized CHP (1MWe to 20MWe) into distribution grids and improve their flexibility and grid support capability. Indeed, the proposed interface converter solution thanks to presence of the grid-ready inverter, allows to streamline the compliance to grid codes requirements, reduce the interconnection delays and costs and ultimately one of the main barriers for CHP adoption by commercial and industrial facilities. An additional benefit provided by the interface converter is the use of the grid-ready inverter for reactive power which eliminates the need of sizing the generator for that capability. These two benefits highly favor the economic feasibility of converter-interfaced CHP. Five user cases, each in one of the leading U.S states for CHP potential reported by the DOE in its estimation of the U.S Technical Potential of CHP, were selected to compare the economic performances of converter-interfaced CHP as compared with directly-coupled. They include a college campus in California, a hospital in New York, a water reclamation plant in Texas, a hotel in Minnesota, and a large office building in Pennsylvania. Results showed that, the presence of the interface converter allows to increase the return on investment (ROI) by 0.5 to 2 percentage points in most of the cases (4 of 5). Indeed, the interface converter by shortening the interconnection process allows to accelerate revenues while reducing interconnection costs. Added to the reduced cost of the required generator these savings trade favorably the capital cost of the converter. The analysis also showed that the profitability of the converter-interfaced CHP is highly sensitive to the energy price, interconnection delay, and converter cost. However, it appears that if the interface converter can shorten the interconnection process by at least 6 months, adopting this solution will be more economically viable than directly-coupled configuration in almost all the +23,000 sites of the U.S Technical Potential CHP. The evaluation of the benefits of a converter-interfaced CHP also showed that it enables higher ROI when coupled with other distributed energy resources (DER) such as battery energy systems (BESS) or solar photovoltaic (PV). Indeed, in those scenario, the grid-ready inverter included in the interface converter eliminates the need of separate inverters if DC-coupling is used. On the technical performance, it has been verified that the presence of the interface converter allows to reduce by 70% to 80% the CHP short-circuit contribution to grid faults. This not only reduces the mechanical and thermal stresses exposed to the CHP electrical components but also increases the grid hosting capacity which ultimately enables higher penetrations CHP. Another key benefit of the interface converter validated with hardware-in-the-loop simulations and testing is its superior capability for reactive power support. Indeed, using a power hardware testbed with two +700kW inverters configured in back-to-back, a microgrid controller and actual facilities loads it was demonstrated that the presence of the interface converter can help maintain a power factor near ~1 or regulate the voltage to ~1.0pu at the point of common coupling. This benefit can be highly valuable if in the future, due to higher penetration of renewable distributed energy resources (DER), utilities start billing demand charge based on kVA instead of kW as currently. It was also validated that converter-interfaced CHP can dispatch heat and power commands and seamlessly switch between the two modes while consistently controlling the power factor or voltage at PCC. Indeed, the power hardware testing showed that grid-connected converter-interfaced CHP can follow either the power or heat demand while maintaining a unity power factor at converter output. This research proved that the adoption of an interface converter as the solution for interconnection of CHP system into the distribution grid can greatly improve the economic feasibility of small to medium-sized CHP as well as the plant power quality, flexibility and resiliency. Additionally, it allows increased penetrations of CHP into the distribution grid, extends their grid support capability, and facilitates the integration of BESS and PV DER by streamlining their collocation within the same facilities. This ultimately provides an opportunity for commercial and small industrial facilities in the U.S to accelerate their energy transition thanks to the high energy efficiency of CHP systems and its reliable, flexible, and resilient microgrid operation when interconnected with an interface converter.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Direct Laser Writing Crystal Polymorphs of Organic Semiconductors for Phase Change Electronics

The many diverse polymorphic behaviors observed in organic electronic materials offer opportunities to modulate electronic properties through reversibly switching crystal structures. Here, we access the prolific polymorphism observed in two-dimensional quinoidal terthiophene via laser writing to locally heat and direct the phase transitions. We access a metastable polymorph IV through rapid cooling and observe distinct symmetry as well as packing through grazing incidence X-ray diffraction (GIXD). Using our open-source PolyChemPrint patterning platform, we direct laser heating to initiate the IV-I transition, switching the conductance by >2 orders of magnitude. Here, this is confirmed via a combination of GIXD and Raman spectroscopy. Finally, we demonstrate switching of transistor devices as well as discrete tuning of conductance via laser writing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal Modeling and Limitations for Power Electronics Embedded in Medium-Voltage Cables

As next-generation energy technologies gain traction and power demand increases, the existing electrical infrastructure faces significant stress, prompting innovative solutions to enhance the grid's capacity and lifespan. This work explores the possibility of embedding medium-voltage (MV) power electronics directly inline with the cable, and the resulting thermal challenges. Since the majority of power distribution cables installed in the U.S. are passively cooled, the work focuses primarily on passive cooling, with an emphasis on the limitations of axial heat spreading within the cable. To date, literature on axial spreading of high incident heat loads on cables and cable environments is limited, typically reporting cases with <10 W of incident heat load. This work will explore the considerations, limits, and tradeoffs of cable-embedded heat loads significantly larger than the cable losses. Both external and internal effects are modeled analytically in nondimensional terms via a Biot number analysis, allowing fundamental limits and tradeoffs to be derived. The work culminates in the design and experimental validation of a cable-embedded thermal system capable of passively dissipating 300 W of heat from a coaxial SiC mosfet switch module over a length of 20 cm, thus validating the possibility of MV cable-embedded power electronics from a thermal standpoint.

24 POWER TRANSMISSION AND DISTRIBUTION↗

White Paper: Research & Development for the Time at Temperature Approach

Recent advancements in nuclear power research are greatly improving reactor safety and performance through the development of Accident Tolerant Fuel (ATF) and Low-Enriched Uranium Plus (LEU+). These innovations can address Departure from Nucleate Boiling (DNB) margins, which are vital for reactor safety. DNB happens when the coolant switches to film boiling, significantly decreasing heat transfer and posing a risk of fuel cladding failure. The U.S. Nuclear Regulatory Commission (NRC) employs conservative DNB criteria, which can potentially restrict the operational flexibility and efficiency of reactors. The Time at Temperature (TaT) approach could provide a more detailed and adaptable operational guideline by establishing acceptable time-temperature limits, accounting for the duration a material can withstand elevated temperatures without losing its integrity. This method allows reactors to operate more efficiently and safely, offering additional operational margins, faster power adjustments, and improved fuel cycle economics. TaT criteria allow for higher power levels and more flexible responses to operational transients, particularly applicable for anticipated operational occurrences (AOOs) that result in short durations of post-DNB conditions. It enhances plant operational flexibility, allows faster startup times, and enables quicker power level adjustments, optimizing fuel loading patterns and improving fuel cycle economics. Implementing TaT limits reduces core design constraints, lowers fuel usage, and reduces costs, essential for the long-term sustainability of Light Water Reactors (LWRs). TaT maximizes the use of advanced fuel technologies like ATF and LEU+, further enhancing their economic and environmental benefits. To apply the TaT approach in existing LWRs, collaborative research activities among various DOE-sponsored programs are essential. These efforts should incorporate fuel experiments, physics-based high-fidelity modeling, ML-based surrogate modeling, and optimization techniques. This whitepaper proposes four research and development areas: 1) Investigation of the feasibility of new operations of LWR with updated safety limits; 2) Assessment of reactor operation limits through uncertainty reduction; 3) Evaluation of power uprate in virtual environment; and 4) Lattice and reactor core design for power uprate. Each area includes why this research is in need and a suggested scope of work. These comprehensive research areas ensure practical and beneficial advancements for existing reactors, translating innovations in nuclear fuel and cladding technology into improved reactor performance and safety.

42 - ENGINEERING↗

A non-volatile thermal switch for building energy savings

Compared with traditional static insulation, a thermally switchable building envelope could reduce annual heating and cooling loads by intermittently coupling to the outside environment when beneficial. Here, we demonstrate a voltage-actuated, contact/non-contact thermal switch that meets the unique challenges of this application. The switch is non-volatile, consuming electricity only briefly while switching and none to hold steady state. The switch ratio is 12, the off state has a low effective thermal conductivity of 0.045 W m -1 K -1 , comparable to fiberglass insulation, and the performance is stable over 1,000 switching cycles. Numerical simulations using real-world climate data show that combining this thermal switch with a thermal storage layer in a building envelope can yield annual energy savings of 9%-55% (heating) and 17%-76% (air conditioning), depending on the climate zone. The greatest benefits are realized when the exterior temperature crosses well above and below the desired interior temperature within a single 24 h period.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗