Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Heat Rejection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Production and Characterization of Additively Manufactured Radiator Panels With Integral Branching Heat Pipes for High-Temperature Heat Rejection

Emerging concepts for fission surface power and nuclear electric propulsion necessitate lightweight, mechanically robust, and thermally efficient heat rejection radiators. State-of-the-art intermediate-temperature (~400 K) composite radiator assemblies have been developed based on titanium-water heat pipes bonded to metal, graphite, and carbon-fiber-based panels. NASA has identified a need for new radiator concepts that can operate at even higher temperatures (500 – 600 K), minimize thermal resistances and thermal stress failures at bond interfaces, and approach areal densities of 2 – 3 kg m -2 . To meet these needs, our team is developing additively manufactured (AM) radiator panels with integral branching wicking heat pipe networks. Water is selected as the working fluid for this temperature range. Based on simulations and thermal vacuum experiments, these branching embedded heat pipe networks can efficiently distribute heat over panels for finned surface efficiencies of η f >70% at T H = 500 K input heat. This paper first presents laser powder-bed fusion AM strategies to produce embedded porous structures for wicking heat pipes in Inconel 718 and titanium alloys (commercially pure and Ti-6Al-4V alloys). Post-build chemical and thermal treatments are described that yield hydrophilic wicking surfaces for operation with water. Transient rate-of-rise experiments with water and acetone are reported that yield estimates for AM wick porosity (ϵ), permeability (K), and effective pore radius ( r pore ). Based on the wick characterization results, small prototype radiator panels (75 × 125 mm) with integrated heat pipe networks were manufactured. Heat rejection performance data are presented from cold thermal vacuum testing, with heat input temperatures up to ~510 K. Future efforts will focus on improving heat pipe performance, optimizing radiator mass, and evaluating larger panels to assess scalability.

nuclear electric propulsion↗

Parametric-Based Heat Rejection Trade Study for Lunar and Martian Surface Operations

Establishing and maintaining a sustained presence on the lunar and/or Martian surfaces will require a diverse portfolio of surface elements (e.g., habitation, mobility, power generation, etc.). Many of these systems generate excess heat that must be rejected across a wide range of magnitudes, temperatures, and duty cycles and under variable environmental conditions. To identify the most promising heat rejection approaches for this diverse portfolio, a heat rejection trade study was conducted to evaluate the performance of different technology approaches across a spectrum of surface environments and heat-load requirements. The trade study consisted of three stages: (1) development of a parametric-based modeling framework, (2) creation of a database of heat rejection technologies, surface elements, and environmental conditions for the Moon and Mars, and (3) execution of a quantitative analysis of various heat rejection technologies across different operating conditions and surface elements. The modeling framework is developed in Python and Excel to prioritize small model size and hence low computational cost to enable large parametric sweeps while avoiding the reliance on proprietary software. Individual heat rejection processes are represented as simple Excel models, and a centralized Python script interfaces with the models to coordinate the parametric study. These simple sizing models were developed to take heat load requirements and environmental parameters as inputs and compute mass, power, and volume as outputs. Rather than assess each heat rejection technology separately for each surface element, a unified parametric space was developed to evaluate all technologies across all elements. This parametric space includes factors related to heat load (e.g., magnitude or temperature) and environment (e.g., surface temperature, sky temperature, solar flux). This effort generated a database containing information on over 60 heat rejection technologies and 30 surface elements. For each surface element, the expected heat rejection requirements were documented and analyzed to determine the most common needs shared across all elements. Environmental conditions at various lunar and Martian latitudes were also established for worst-case hot and worst-case cold scenarios. High-fidelity heat rejection models are currently under development. Preliminary trades between heat rejection technologies including radiators, venting technologies, convective coolers, and more have been conducted to identify promising options. This presentation will summarize the preliminary trade results and provide an overview and discussion of the expected heat loads and thermal environments for sustained surface operations on the Moon and Mars.

Heat Rejection↗

Development of advanced high temperature in-cylinder components and tribological systems for low heat rejection diesel engines, phase 1

Analysis and concept design work completed in Phase 1 have identified a low heat rejection engine configuration with the potential to meet the Heavy Duty Transport Technology program specific fuel consumption goal of 152 g/kW-hr. The proposed engine configuration incorporates low heat rejection, in-cylinder components designed for operation at 24 MPa peak cylinder pressure. Water cooling is eliminated by selective oil cooling of the components. A high temperature lubricant will be required due to increased in-cylinder operating temperatures. A two-stage turbocharger air system with intercooling and aftercooling was selected to meet engine boost and BMEP requirements. A turbocompound turbine stage is incorporated for exhaust energy recovery. The concept engine cost was estimated to be 43 percent higher compared to a Caterpillar 3176 engine. The higher initial engine cost is predicted to be offset by reduced operating costs due the lower fuel consumption.

Kroeger, C. A.↗

Development of a Self-contained Heat Rejection Module (SHRM), phase 1

The laboratory prototype test hardware and testing of the Self-Contained Heat Rejection Module are discussed. The purpose of the test was to provide operational and design experience for application to a flight prototype design. It also provided test evaluation of several of the actual components which were to be used in the flight prototype hardware. Several changes were made in the flight prototype design due to these tests including simpler line routing, relocation of remote operated valves to a position upstream of the expansion valves, and shock mounting of the compressor. The concept of heat rejection control by compressor speed reduction was verified and the liquid receiver, accumulator, remote control valves, oil separator and power source were demonstrated as acceptable. A procedure for mode changes between pumped fluid and vapor compression was developed.

Fleming, M. L.↗

Method of Minimizing Size of Heat Rejection Systems for Thermoelectric Coolers to Cool Detectors in Space

A thermal design concept of attaching the thermoelectric cooler (TEC) hot side directly to the radiator and maximizing the number of TECs to cool multiple detectors in space is presented. It minimizes the temperature drop between the TECs and radiator. An ethane constant conductance heat pipe transfers heat from the detectors to a TEC cold plate which the cold side of the TECs is attached to. This thermal design concept minimizes the size of TEC heat rejection systems. Hence it reduces the problem of accommodating the radiator within a required envelope. It also reduces the mass of the TEC heat rejection system. Thermal testing of a demonstration unit in vacuum verified the thermal performance of the thermal design concept.

thermoelectric coolers↗

Development of a self contained heat rejection module, phase 2 and 3

This is the final report for Phases II and III of the Development of a Self Contained Heat Rejection Module Program conducted under NASA contract NAS9-14408. The objective of this program was to perform detail design and construct a prototype test article Self Contained Heat Rejection Module (SHRM). Also to install this test article in the NASA/JSC Space Environment Simulation Laboratory Chamber A and conduct thermal vacuum demonstration and performance testing. The end product of this contract was the prototype hardware, the test article and the test results.

M L Fleming↗

In-Situ Heat Rejection to the Martian Atmosphere

In order to provide in-situ heat rejection to the thin Martian atmosphere, approaches relying on forced convection and buoyancy flow are conceptualized. A convective radiator concept utilizing a fan to draw local atmosphere through an expanded metal foam heat exchanger panel is developed. To provide a pumped fluid loop interface, flow tubes are embedded in the heat exchanger panel and heat is transferred from the tubes to the foam via conduction and subsequently convectively to the environment. To forgo the use of a specialized high throughput fan, a concept utilizing a buoyant chimney tower to draw atmospheric flow through a low pressure drop heat exchanger is also considered. Both concepts may best align with moderate- to high-temperature heat loads that provide a significant delta temperature relative to the ambient atmosphere temperature. While eliminating dust accumulation on radiator surfaces, some type of serviceable filtration or screening may be required to prevent accumulation of dust inside the expanded metal foam heat exchanger for both concepts.

Heat Rejection↗

Hybrid honeycomb panel heat rejection system

The evolution of a hybrid honeycomb panel heat rejection system concept for future high-power spacecraft is described. Performance evaluation of this heat pipe-based hybrid radiator is based on data and prediction models from a developmental component hardware testing program. The concept integrates three high-performance components into an optimized radiator system. These components are the sideflow heat pipe transport leg, honeycomb panel evaporator, and light-weight high-efficiency heat pipe fins. A 3.05 m (10 ft.) long hybrid radiator was designed considering remnant hardware available from other Hughes programs. The key performance objective for the hybrid radiator was to demonstrate high thermal transport capacity, increased radiating fin lengths, improved thermal efficiency across structural boundaries, and reduced weight. Analysis showed that 9000 W can be transported over a 3.05 m radiator and that finlengths of up to 1 m are possible.

Tanzer, H. J.↗

The Liquid Droplet Radiator - an Ultralightweight Heat Rejection System for Efficient Energy Conversion in Space

A heat rejection system for space is described which uses a recirculating free stream of liquid droplets in place of a solid surface to radiate waste heat. By using sufficiently small droplets ( 100 micron diameter) of low vapor pressure liquids the radiating droplet sheet can be made many times lighter than the lightest solid surface radiators (heat pipes). The liquid droplet radiator (LDR) is less vulnerable to damage by micrometeoroids than solid surface radiators, and may be transported into space far more efficiently. Analyses are presented of LDR applications in thermal and photovoltaic energy conversion which indicate that fluid handling components (droplet generator, droplet collector, heat exchanger, and pump) may comprise most of the radiator system mass. Even the unoptimized models employed yield LDR system masses less than heat pipe radiator system masses, and significant improvement is expected using design approaches that incorporate fluid handling components more efficiently. Technical problems (e.g., spacecraft contamination and electrostatic deflection of droplets) unique to this method of heat rejectioon are discussed and solutions are suggested.

A T Mattick↗

Solar dynamic organic Rankine cycle heat rejection system simulation

The use of a rotary fluid management device (RFMD) and shear flow condenser for two-phase fluid management in microgravity organic Rankine cycle (ORC) applications is examined. A prototype of the proposed Space Station ORC heat rejection system was constructed to evaluate the performance of the inventory control method. The design and operation of the RFMD, shear flow condenser, and inventory control fluid accumulator are described. A schematic diagram of the ORC, RFMD, and condenser, and a functional diagram of the heat rejection system for the ORC are presented.

Havens, V. N.↗

Recent Advances in Power Conversion and Heat Rejection Technology for Fission Surface Power

Under the Exploration Technology Development Program, the National Aeronautics and Space Administration (NASA) and the Department of Energy (DOE) are jointly developing Fission Surface Power (FSP) technology for possible use in human missions to the Moon and Mars. A preliminary reference concept was generated to guide FSP technology development. The concept consists of a liquid-metal-cooled reactor, Stirling power conversion, and water heat rejection, with Brayton power conversion as a backup option. The FSP project has begun risk reduction activities on some key components with the eventual goal of conducting an end-to-end, non-nuclear, integrated system test. Several power conversion and heat rejection hardware prototypes have been built and tested. These include multi-kilowatt Stirling and Brayton power conversion units, titanium-water heat pipes, and composite radiator panels.

Mason, Lee↗

The Effect of Transfer Line Length and Heat Rejection Temperature Distribution on the Thales Linear Pulse Tube (LPT) Cryocoolers

Four Thales LPT9310 and four Thales LPT9510 commercial off-the-shelf (COTS) cryocoolers were parametrically performance tested. The LPT9310 coolers had transfer lines of various lengths while the LPT9510 coolers all had the same transfer line geometry. The LPT9510 test results revealed unit-tounit thermodynamic performance variation, quantified the effect of compressor temperature on thermodynamic performance and quantified the heat flow distribution between the compressor and expander as a function of their temperature distribution. The LPT9310 test results revealed the optimal drive frequency as a function of transfer line length, quantified the effect of heat rejection temperature distribution on thermodynamic performance and enabled the development and verification of a thermodynamic performance prediction tool that accounted for cold tip temperature, heat lift, heat rejection temperature and transfer line length.

Rodriguez, J.I.↗