Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HVDC transmission”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Operation and control of hybrid HVDC system with LCC and full-bridge MMC connected in parallel

In this study, a new kind of hybrid high-voltage direct current (HVDC) system is proposed. Each terminal of the proposed system consists of one line commutated converter (LCC) and one full-bridge modular multilevel converter (FB-MMC). The LCC and FB-MMC are connected in parallel so that they can share the same transmission line. The active–reactive power capability of the hybrid HVDC system is extended compared with the conventional LCC-HVDC system, and power reversal control without power interruption can be achieved by the coordination control of LCC and FB-MMC. Besides, the proposed hybrid HVDC system is capable of handling DC fault, because both LCC and FB-MMC have DC fault blocking capability. Moreover, the power rating of FB-MMC can be designed to low value while keeping the bulk-power transmission capability of LCC. A two-terminal bipolar hybrid HVDC system is built in PSCAD/EMTDC. The simulation results verify the effectiveness and feasibility of the proposed hybrid topology and corresponding control strategies.

42 ENGINEERING↗

Developing VSC-HVDC Oscillation Damping Control Constraints in Unit Commitment

High-voltage direct current (HVDC) systems within the existing power grids will play a pivotal role in enabling high share of renewable power integration and transportation electrification. There is a need for transmission planning models to accurately capture the impact of VSC-HVDC oscillation damping control on the system planning and model the constraints in the security constrained unit commitment (SCUC) problem. In this paper, the SCUC problem in a hybrid DC-AC grid considering damping on electromechanical inter-area oscillation is studied. An electromechanical oscillation-driven transmission capability constraints are derived from system swing equation and incorporated into the SCUC. Multiple system damping control scenarios are set based on the extracted plausible bounds of damping coefficient and inertia constant to linearize the nonlinear expressions. The SCUC problem with proposed constraints is tested on the IEEE 73-bus reliability test system (RTS) case via PLEXOS. The impact of the proposed constraints on regional generation, inertia, power flow, annual system cost, and renewable energy curtailment are fully assessed.

damping control↗

Mixed Monopole and Bipole MTdc Architecture

Multi-terminal dc systems (MTdc) are becoming popular at transmission level voltages. High-voltage dc (HVdc) based on voltage-source-converter (VSC) technology is employed in such systems. In this paper, a new MTdc architecture, which is suitable for future expansion and easy operation under overhaul and maintenance of the converter stations is proposed. Steady state and dc fault simulation studies are performed to prove the feasibility of the MTdc architecture. Technical advantages and challenges related to the new architecture are detailed.

Jaldanki, Sreenivasa↗

The Role and Value of Interregional Transmission in a Decarbonized U.S. Electricity System

Decarbonizing the U.S. energy system entails a significant expansion of wind and solar power and electrification of end-use applications. Achieving both is more efficient and less costly when interregional transmission capacity is expanded, but the fractured nature of grid planning in the United States is often a barrier to such expansion. Here, we explore the role of interregional transmission under a variety of decarbonization scenarios, using a capacity-expansion model to generate co-optimized portfolios of generation, storage, and transmission that meet decarbonization targets and electrification-driven demand. We explore portfolio and cost differences across 92 scenarios, from scenarios with limited transmission expansion to those that include a meshed high-voltage direct current (HVDC) network. In the core decarbonization scenarios, wind capacity expands by ~10x and solar by ~20x compared to 2020, hundreds of gigawatts of battery storage are deployed, and interregional transmission expands by 3-6x. Transmission expansion occurs nationwide but is concentrated between the central "wind belt" and eastern load centers. The HVDC scenarios result in hundreds of billions of dollars of savings in total system cost, demonstrating the economic benefits of interregional transmission in support of rapid decarbonization.

capacity expansion↗

Adaptive Fault Current-Limiting Control of MMC for Protection of Multiterminal HVDC Systems: Preprint

For the development of multi-terminal high voltage DC (MTDC) transmission, it is critical to design the protection system that can selectively isolate the faulty area from the healthy part of the dc grid using DC circuit breakers (DCCBs) while ensuring continuous operation of converter stations in the healthy part. However, because of the lack of fault current blocking capability in half-bridge (HB) modular multilevel converters (MMCs), when a dc fault occurs, the rising fault currents can quickly reach the blocking threshold within a few milliseconds and disrupt the operation of MMCs in the healthy part. Large DC reactors are often considered in series with DCCBs to reduce the rate of rise of fault currents and prevent blocking of MMCs in the healthy part of the grid. However, large DC reactors can prohibitively increase the cost of the system, particularly when they are considered in an offshore environment, for instance in offshore wind projects. Large dc reactors can also introduce stability issues and create post-fault oscillations. This paper presents an adaptive fault current limiting control method for MMCs to avoid their blocking and enable continuous operation of MTDC systems. It contains two parts: The first part is based on circulating current feedforward control that emulates virtual reactors in each arm of an MMC, which is immediately activated when the fault current starts to increase, to reduce the rate of rise of the fault current; the second part is triggered when the fault current exceeds a preset threshold by temporarily bypassing the SMs, serving as a complement to the fault current limiting effect of the first part. Both parts do not require fault detection signal and they are activated automatically during faults. Simulation case studies of a four-terminal bipolar MMC-HVDC system are presented to demonstrate the effectiveness of the proposed control methods.

active fault current limiting↗

Virtual Synchronous Generator Control of Multi-port Autonomous Reconfigurable Solar Plants (MARS)

Multi-port autonomous reconfigurable solar power plant (MARS) is an integrated concept for integration of solar photovoltaic (PV) and energy storage systems (ESS) to transmission alternating current (ac) grid and high-voltage direct current (HVdc) links. The integrated development incorporates advanced control methods to provide enhanced grid ancillary services such as fast frequency responses and dynamic voltage support. In this paper, the virtual synchronous generator (VSG) control algorithm of MARS is discussed. The proposed VSG-based control enables enhanced synthetic inertial response and flexible frequency response characteristics of hybrid PV and ESS power plants in accordance with grid ancillary service requirements. Multi-port power electronics interface allows controlled emergency power support from MARS to local transmission ac grid and remote grid through the HVdc link. The performance of VSG control is validated using a reduced-order model of MARS in Simulink. Methods for estimating grid ancillary service capabilities of MARS are also discussed.

Pan, Jiuping↗

Developing VSC-HVDC Oscillation Damping Control Constraints in Unit Commitment

High-voltage direct current (HVDC) systems within the existing power grids will play a pivotal role in enabling high share of renewable power integration and transportation electrification. There is a need for transmission planning models to accurately capture the impact of VSC-HVDC oscillation damping control on the system planning and model the constraints in the security constrained unit commitment (SCUC) problem. In this paper, the SCUC problem in a hybrid DC-AC grid considering damping on electromechanical inter-area oscillation is studied. An electromechanical oscillation-driven transmission capability constraints are derived from system swing equation and incorporated into the SCUC. Multiple system damping control scenarios are set based on the extracted plausible bounds of damping coefficient and inertia constant to linearize the nonlinear expressions. The SCUC problem with proposed constraints is tested on the Reliability Test System Grid Modernization Lab Consortium (RTS-GMLC) via PLEXOS. The impact of the proposed constraints on regional generation, inertia, power flow, annual system cost, and renewable energy curtailment are fully assessed.

damping control↗

Guest Editorial: Control interactions in power electronic converter dominated power systems

The modern power systems have undergone significant transformations at the generation, transmission, distribution, and utilization levels due to the remarkable advancements in power electronic converter technology. Power electronic converters are now prevalent in various applications, including wind turbine converters, photovoltaic inverters, flexible AC transmission systems (FACTS) and high-voltage DC (HVDC) converters, distributed generators, microgrids, and electric vehicles. The widespread adoption of power electronic converters has revolutionized the power system by providing fast and flexible controllability. However, their unique characteristics, such as fast response, multi-time scale dynamics, reconfigurable control, and varying sizes and capacities, have introduced new stability challenges, fundamentally altering the dynamics of modern power systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Improving power grid transient stability and transfer capability using HVDC emergency power controls

In the future, with high levels of renewable energy sources penetration, the transmission corridors will have to be flexible to operate under faster transients and variable power flows. Fast power ramping and overloading capabilities of HVDC system can be utilized to ensure transient stability of the interconnected power grid. In this paper, HVDC auxiliary controllers have been studied that can provide the power grid with additional synchronizing torques through fast DC power changes in response to arising system conditions. The effectiveness of the auxiliary controllers in improving transient stability is demonstrated by performing dynamic simulations on the detailed model of the Western Interconnection system (WECC).

Sundaresh, Lakshmi↗

Capacity contributions of Southern Oregon offshore wind to the Pacific Northwest and California

Variable renewable energy generation poses unique capacity challenges, which increasingly depend on weather events at varying timescales. Facilitated by transmission planning, geographic and technological diversity of the generation fleet may provide a mitigation to capacity shortfalls. In this work, offshore wind (OSW) energy is sited in the areas off the West Coast between Coos Bay, Oregon, and Crescent City, California. Three generation and transmission scenarios are modeled within the Western Interconnection: (i) 3.4 gigawatts (GW) of installed OSW capacity connected to Southern Oregon through a High Voltage Alternating Current (HVAC) Radial Topology in 2030; (ii) 12.9 GW of installed OSW capacity connected to Washington, Oregon, and California through a High Voltage Direct Current (HVDC) Radial Topology post-2030, and (iii) the same 12.9 GW connected to the same locations through a Multi-terminal DC (MTDC) Backbone Topology post-2030. Zonal dispatch simulations assuming coincident wind, solar, and hydropower production and loads over 18 meteorological years, accounting for temperature-dependent equipment derating and forced outages, serve as inputs to the Associated System Capacity Contribution (ASCC) methodology. The capacity credit is 33%, 25% and 34% for the 2030 HVAC Radial Topology, 2030+ HVDC Radial Topology, and 2030+ MTDC Backbone Topology, respectively. Transmission design is shown to mitigate the typical erosion of marginal capacity contribution as more OSW is developed, underscoring the opportunity for grid modernization while decarbonizing the generation mix.

17 WIND ENERGY↗

Interregional Transmission Operational Coordination

This presentation will discuss challenges and opportunities on interregional coordination in the areas of interchange transaction, congestion management, reserve sharing and deliverability across multi-stage operational processes. It will then provide an overview of the interregional transmission operational coordination (IRTOC) project that currently focuses on congestion management, including Inter-regional transmission coordination in real time operations and operational planning, HVDC optimization (intra- and interregional), ancillary service deliverability (intra- and interregional). In addition, it will discuss the Sienna-Decomposition tool development to systematically study interregional coordination methods.

congestion management↗

Design and Stability Analysis of Control System in Multiport Autonomous Reconfigurable Solar Power Plants (MARS)

The Multiport Autonomous Reconfigurable Solar Power Plant (MARS) is an integrated photovoltaic (PV) power generation and energy storage system (ESS), that is designed to connect to both alternating current (AC) transmission grids and high-voltage direct current (HVDC) links. It is a three-phase plant consisting of numerous components with a complex hardware and hierarchical control architecture. This paper presents an approach to decouple the multivariable system of MARS using a recursive reduced-order and boundary layer system methodology. This approach enables efficient computation of the control parameters for the Ll, L2, and L3 controllers. To validate the effectiveness of the proposed control strategy, cyclic tests in accordance with pre-defined performance criteria using controller Hardware-in-the-Loop (cHIL) experiments are conducted. The results demonstrate that the MARS system operates consistently under steady-state conditions. Furthermore, the dynamic response of the MARS system to various grid events is analyzed, underlining the resilience of MARS in presence of faults or loss of generation within the connected WECC system.

Xia, Qian↗

Synchronverter-based Control of Multi-Port Autonomous Reconfigurable Solar Plants (MARS)

Control of integrated photovoltaic (PV) plants with energy storage systems (ESSs) has become an important research and development topic in recent times. In this context, a Multi-port Autonomous Reconfigurable Solar (MARS) plant that integrates PV and ESS to alternating current transmission grid and high-voltage direct current (HVdc) link is studied in this paper. With penetration of power electronic based resources in the grid, the grid’s capability to recover from frequency or voltage disturbances are reduced. Therefore, one of the vital objectives of any new grid integrated power electronic resource is to provide advanced control functions like voltage and frequency support to the grid during disturbances. In this research work, a detailed implementation of a synchronverter-based control algorithm of MARS is presented. The proposed control algorithm and the MARS control architecture are evaluated through simulations on PSCAD/EMTDC simulation platform to showcase the performance in different operating conditions. In addition, they are evaluated in Opal-RT offline simulation models which can also be used to perform control-hardware-in-the-loop (cHIL) tests.

Marthi, Phani Ratna Vanamali↗

Review of hybrid HVDC systems combining line communicated converter and voltage source converter

Hybrid HVDC system, which consists of the advantages of line commutated converter (LCC) and voltage source converter (VSC), is an emerging power transmission system. This paper presents a review of four LCC-VSC hybrid HVDC topologies. The first topology is the pole-hybrid HVDC system, in which the LCC and VSC form the positive- and negative-pole respectively. The second one is the terminal-hybrid HVDC system; in this topology one terminal adopts LCC and the other terminal adopts VSC. The series converter-hybrid HVDC system is the third topology wherein each terminal is formed by LCC and VSC in series. The fourth hybrid topology under consideration is a parallel converter-hybrid HVDC system with LCC and VSC connected in parallel in each terminal. Here, the main contribution of this paper is a comprehensive analysis and comparison of the four mentioned hybrid topologies in terms of PQ operating zone, power flow reversal method, and DC fault ride-through strategy.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Fault location in High Voltage Multi-terminal dc Networks Using Ensemble Learning

Precise location of faults for large distance power transmission networks is essential for faster repair and restoration process. High Voltage direct current (HVdc) networks using modular multi-level converter (MMC) technology has found its prominence for interconnected multi-terminal networks. This allows for large distance bulk power transmission at lower costs. However, they cope with the challenge of dc faults. Fast and efficient methods to isolate the network under dc faults have been widely studied and investigated. After successful isolation, it is essential to precisely locate the fault. The post-fault voltage and current signatures are a function of multiple factors and thus accurately locating faults on a multi-terminal network is challenging. In this paper, we discuss a novel data-driven ensemble learning based approach for accurate fault location. Here we utilize the eXtreme Gradient Boosting (XGB) method for accurate fault location. The sensitivity of the proposed algorithm to measurement noise, fault location, resistance and current limiting inductance are performed on a radial three-terminal MTdc network designed in Power System Computer Aided Design (PSCAD)/Electromagnetic Transients including dc (EMTdc).

24 POWER TRANSMISSION AND DISTRIBUTION↗

Frequency Injection Based HVDC Attack-Defense Control Via Squeeze-Excitation Double CNN

Due to the independent controllability and fast power regulation capability, the High Voltage Direct Current (HVDC) system could be a prospective technology to provide multiple ancillary services to the system besides conventional bulk power transmission. However, with the increase of False Data Injection Attacks (FDIAs) on PMU data, the HVDC system could have the wrong response once the collected data that the HVDC system relied on is attacked, thus threatening the system operating security. How to ensure the security of the PMU-based HVDC ancillary service control become an urgent issue. To mitigate the risk, this paper proposed an HVDC attack-defense control based on the FDIAs detection method. Firstly, the Squeeze-Excitation based Double Convolutional Neural Networks (SE-DCNN) is proposed to realize fast identification of the attacking frequency type based on the time and frequency domain signals. Furthermore, the duration time of FDIAs is detected by the local outlier factor. Then, utilizing the results from SE-DCNN, HVDC ancillary service control framework is reorganized and an HVDC attack defense control is proposed for suppressing the potential influence of various types of FDIAs on the HVDC system ancillary service. Different experiments results demonstrate that the proposed method has the ability to significantly mitigate the frequency deviation and oscillation under the FDIA.

42 ENGINEERING↗

Multiterminal High-Voltage dc Systems with Series-Parallel Valve Group-Based High-Voltage dc Substations

To transfer large amount of power over long distances, multiterminal direct current (MTdc) system based on bipole high-voltage direct current (HVdc) technology is a viable option. However, such system results in large dc transmission loss. The same can be reduced by increasing the dc voltage level. This paper introduces a new MTdc system architecture comprising of series (for increasing dc voltage level) and parallel (for increasing dc current capability) connected HVdc converters. The new architecture is compared with the bipole MTdc architecture in terms of equipment needed and dc transmission loss. The control modifications needed for the MTdc system are identified and the performance of the developed control is verified through electromagnetic transient (EMT) simulations.

Jaldanki, Sreenivasa↗

Creation of Synthetic Electric Grids (SPP/MISO) Supporting PERFORM (Final Report)

Over the course of the project, two “realistic but not real” synthetic transmission-level grid models over the SPP-MISO and ERCOT footprints were created to provide more realistic data and increase the reliability and resiliency of the grids under a variety of scenarios. The synthetic ERCOT transmission grid is compatible with the distribution grid developed in collaboration with NREL. All generators are based on the EIA 860 data and a column with EIA plant code and Gen ID is added to generators of both grids so that they can be easily mapped. The improvements are also made to electric grids including N-1 contingencies with some remedial actions, improving the transmission lines to avoid lines in lakes, including an HVDC line to the SPP-MISO case, providing several generator parameters and their temporal constraints that were not included in EIA 860 form, generators’ cost curves, load offer curves, adding phase shifters and tap changers with impedance correction tables, adding reactive power control and partitioning the grids into active and reactive reserve zones and determine different types of the required reserve for each zone. Hourly load time series at the bus level were generated to create scenarios for solving power flow in different loading conditions. Weather measurement information and the models of renewable generators are used to directly include the impact of weather on the grids. Based on a variety of load and weather conditions the grids are improved to accommodate different conditions. The ERCOT 7k-bus grids were also modeled for the year 2030 with predicted improvements in renewable resources. The renewable generation model was also improved with historic weather data included. The impact of electric vehicles on the ERCOT grid is also modeled.

24 POWER TRANSMISSION AND DISTRIBUTION↗