Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HIP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Artifact Reduction in X-Ray CT Images of Al-Steel-Perspex Specimens Mimicking a Hip Prosthesis

X-ray Computed Tomography (CT) is a relatively new technique developed in the late 1970's, which enables the nondestructive visualization of the internal structure of objects. Beam hardening caused by the polychromatic spectrum is an important problem in X-ray computed tomography (X-CT). It leads to various artifacts in reconstruction images and reduces image quality. In the present work we are considering the Artifact Reduction in Total Hip Prosthesis CT Scan which is a problem of medical imaging. We are trying to reduce the cupping artifact induced by beam hardening as well as metal artifact as they exist in the CT scan of a human hip after the femur is replaced by a metal implant. The correction method for beam hardening used here is based on a previous work. Simulation study for the present problem includes a phantom consisting of mild steel, aluminium and perspex mimicking the photon attenuation properties of a hum hip cross section with metal implant.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

CHARACTERIZING K2 PLANET DISCOVERIES: A SUPER-EARTH TRANSITING THE BRIGHT K DWARF HIP 116454

We report the first planet discovery from the two-wheeled Kepler (K2) mission: HIP 116454 b. The host star HIP 116454 is a bright (V = 10.1, K = 8.0) K1 dwarf with high proper motion and a parallax-based distance of 55.2 ± 5.4 pc. Based on high-resolution optical spectroscopy, we find that the host star is metal-poor with [Fe/H] =–0.16 ± 0.08 and has a radius R {sub *} = 0.716 ± 0.024 R {sub ☉} and mass M {sub *} = 0.775 ± 0.027 M {sub ☉}. The star was observed by the Kepler spacecraft during its Two-Wheeled Concept Engineering Test in 2014 February. During the 9 days of observations, K2 observed a single transit event. Using a new K2 photometric analysis technique, we are able to correct small telescope drifts and recover the observed transit at high confidence, corresponding to a planetary radius of R{sub p} = 2.53 ± 0.18 R {sub ⊕}. Radial velocity observations with the HARPS-N spectrograph reveal a 11.82 ± 1.33 M {sub ⊕} planet in a 9.1 day orbit, consistent with the transit depth, duration, and ephemeris. Follow-up photometric measurements from the MOST satellite confirm the transit observed in the K2 photometry and provide a refined ephemeris, making HIP 116454 b amenable for future follow-up observations of this latest addition to the growing population of transiting super-Earths around nearby, bright stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Automated generation of IMRT treatment plans for prostate cancer patients with metal hip prostheses: Comparison of different planning strategies

Purpose: To compare IMRT planning strategies for prostate cancer patients with metal hip prostheses.Methods: All plans were generated fully automatically (i.e., no human trial-and-error interactions) using iCycle, the authors' in-house developed algorithm for multicriterial selection of beam angles and optimization of fluence profiles, allowing objective comparison of planning strategies. For 18 prostate cancer patients (eight with bilateral hip prostheses, ten with a right-sided unilateral prosthesis), two planning strategies were evaluated: (i) full exclusion of beams containing beamlets that would deliver dose to the target after passing a prosthesis (IMRT{sub remove}) and (ii) exclusion of those beamlets only (IMRT{sub cut}). Plans with optimized coplanar and noncoplanar beam arrangements were generated. Differences in PTV coverage and sparing of organs at risk (OARs) were quantified. The impact of beam number on plan quality was evaluated.Results: Especially for patients with bilateral hip prostheses, IMRT{sub cut} significantly improved rectum and bladder sparing compared to IMRT{sub remove}. For 9-beam coplanar plans, rectum V{sub 60Gy} reduced by 17.5%{+-} 15.0% (maximum 37.4%, p= 0.036) and rectum D{sub mean} by 9.4%{+-} 7.8% (maximum 19.8%, p= 0.036). Further improvements in OAR sparing were achievable by using noncoplanar beam setups, reducing rectum V{sub 60Gy} by another 4.6%{+-} 4.9% (p= 0.012) for noncoplanar 9-beam IMRT{sub cut} plans. Large reductions in rectum dose delivery were also observed when increasing the number of beam directions in the plans. For bilateral implants, the rectum V{sub 60Gy} was 37.3%{+-} 12.1% for coplanar 7-beam plans and reduced on average by 13.5% (maximum 30.1%, p= 0.012) for 15 directions.Conclusions: iCycle was able to automatically generate high quality plans for prostate cancer patients with prostheses. Excluding only beamlets that passed through the prostheses (IMRT{sub cut} strategy) significantly improved OAR sparing. Noncoplanar beam arrangements and, to a larger extent, increasing the number of treatment beams further improved plan quality.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cancer risk estimates from radiation therapy for heterotopic ossification prophylaxis after total hip arthroplasty

Purpose: Heterotopic ossification (HO) is a frequent complication following total hip arthroplasty. This study was conducted to calculate the radiation dose to organs-at-risk and estimate the probability of cancer induction from radiotherapy for HO prophylaxis.Methods: Hip irradiation for HO with a 6 MV photon beam was simulated with the aid of a Monte Carlo model. A realistic humanoid phantom representing an average adult patient was implemented in Monte Carlo environment for dosimetric calculations. The average out-of-field radiation dose to stomach, liver, lung, prostate, bladder, thyroid, breast, uterus, and ovary was calculated. The organ-equivalent-dose to colon, that was partly included within the treatment field, was also determined. Organ dose calculations were carried out using three different field sizes. The dependence of organ doses upon the block insertion into primary beam for shielding colon and prosthesis was investigated. The lifetime attributable risk for cancer development was estimated using organ, age, and gender-specific risk coefficients.Results: For a typical target dose of 7 Gy, organ doses varied from 1.0 to 741.1 mGy by the field dimensions and organ location relative to the field edge. Blocked field irradiations resulted in a dose range of 1.4–146.3 mGy. The most probable detriment from open field treatment of male patients was colon cancer with a high risk of 564.3 × 10{sup −5} to 837.4 × 10{sup −5} depending upon the organ dose magnitude and the patient's age. The corresponding colon cancer risk for female patients was (372.2–541.0) × 10{sup −5}. The probability of bladder cancer development was more than 113.7 × 10{sup −5} and 110.3 × 10{sup −5} for males and females, respectively. The cancer risk range to other individual organs was reduced to (0.003–68.5) × 10{sup −5}.Conclusions: The risk for cancer induction from radiation therapy for HO prophylaxis after total hip arthroplasty varies considerably by the treatment parameters, organ site in respect to treatment volume and patient's gender and age. The presented risk estimates may be useful in the follow-up studies of irradiated patients.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-504: Usefulness of CT-MR Fusion in Radiotherapy Planning for Prostate Cancer Patient with Bilateral Hip Replacements

Purpose: Target localization of prostate for Intensity Modulated Radiation Therapy (IMRT) in patients with bilateral hip replacements is difficult due to artifacts in Computed Tomography (CT) images generated from the prostheses high Z materials. In this study, Magnetic Resonance (MR) images fused with CT images are tested as a solution. Methods: CT images of 2.5 mm slice thickness were acquired on a GE Lightspeed scanner with a flat-topped couch for a prostate cancer patient with bilateral hip replacements. T2 weighted images of 5 mm separation were acquired on a MR Scanner. After the MR-CT registration on a radiotherapy treatment planning system (Eclipse, Varian), the target volumes were defined by the radiation oncologists on MR images and then transferred to CT images for planning and dose calculation. The CT Hounsfield Units (HU) was reassigned to zero (as water) for artifacts. The Varian flat panel treatment couch was modeled for dose calculation accuracy with heterogeneity correction. A Volume Matrix Arc Therapy (VMAT) and a seven-field IMRT plans were generated, each avoiding any beam transversing the prostheses; the two plans were compared. The superior VMAT plan was used for treating the patient. In-vivo dosimetry was performed using MOSFET (Best Canada) placed in a surgical tube inserted into the patient rectum during therapy. The measured dose was compared with planned dose for MOSFET location. Results: The registration of MR-CT images and the agreement of target volumes were confirmed by three physicians. VMAT plan was deemed superior to IMRT based on dose to critical nearby structures and overall conformality of target dosing. In-vivo measured dose compared with calculated dose was -4.5% which was likely due to attenuation of the surgical tube surrounding MOSFET. Conclusion: When artifacts are present on planning CT due to bilateral hip prostheses, MR-CT image fusion is a feasible solution for target delineation.

60 APPLIED LIFE SCIENCES↗

SU-F-T-374: Dosimetric Effects of Irradiation Through a Bilateral Hip Prosthesis in a MRI Linac

Purpose: To evaluate the interface effects when irradiating through a hip prosthesis in the presence of an orthogonal 1.5 T magnetic field using Monte Carlo simulations. Methods: A 20×20×38 cm virtual phantom with two 5×5×5 cm sections of bilateral titanium hip prosthesis was created in GPU-based Monte Carlo (MC) algorithm (GPUMCD, Elekta AB, Stockholm Sweden). The lateral prosthesis spacing was based on a representative patient CT scan. A treatment SAD of 143.5 cm was chosen, corresponding to the Elekta AB MRI Linac and the beam energy distribution was sampled from a histogram representing the true MRI Linac spectrum. A magnetic field of 1.5 T was applied perpendicular to the plane of irradiation. Dose was calculated, in voxels of side 1 mm, for 2×2, 5×5, and 10×10 cm treatment field sizes with normal beam incidence (gantry at 90° or 270°) and at 5° and 10° from normal, representing the range of incidence through the bilateral prosthesis. Results: With magnetic field ON (B-On) and normal beam incidence the backscatter dose at the interfaces of proximal and distal implants is reduced for all the field sizes compared to the magnetic field OFF (B-Off) case. The absolute reduction in doses at the interface was in the range of 12.93% to 13.16% for the proximal implant and 13.57% to 16.12% for the distal implant. Similarly for the oblique incidences of 5o and 10o the dose in the plane adjacent to the prosthetic implants is lower when the magnetic field is ON. Conclusion: The dosimetric effects of irradiating through a hip prosthesis in the presence of a transverse magnetic field have been determined using MC simulation. The backscatter dose reduction translates into significantly lower hot spots at the prosthetic interfaces, which are otherwise substantially high in the absence of the magnetic field. This project was supported through funding provided by ElektaTM.

60 APPLIED LIFE SCIENCES↗

Canless HIP Development for Aluminum Cladding of LEU Fuel Foils using Electron Beam Welding

The conventional canning method for HIP processing of fuel foils requires that foil assemblies be stacked within a stainless steel can, which is then welded shut and the internal air evacuated. A few of the detracting aspects associated with this method include i) the time required to hand construct and disassemble each can, ii) the possibility for bonding between adjacent foil assemblies and backing plates, and iii) the generation of large volumes of contaminated waste (can material and backing plates) that must be disposed. The new “canless” HIP approach discussed in this report involves the hermetic sealing of individual foil assemblies by electron beam welding their outer perimeter. A foil assembly consists of a zirconium-clad LEU (U-10Mo) foil sandwiched between two aluminum 6061 plates. Hermetic sealing is accomplished by making 4 intersecting aluminum-to-aluminum, full-penetration lap welds as shown in Figure 1. Since welds are made in a hard vacuum (10-5 torr), there is no need for a separate air evacuation step. The fuel itself sits within a pocket machined into one of the aluminum plates. Multiple foil assemblies welded in this manner can then be placed in a HIP fixture and batch processed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving 6061-Al Grain Growth and Penetration across HIP-Bonded Clad Interfaces in Monolithic Fuel Plates: Initial Studies

Grain penetration across aluminum-aluminum cladding interfaces in research reactor fuel plates is desirable and was obtained by a legacy roll-bonding process, which attained 20-80% grain penetration. Significant grain penetration in monolithic fuel plates produced by Hot Isostatic Press (HIP) fabrication processing is equally desirable but has yet to be attained. The goal of this study was to modify the 6061-Al in such a way as to promote a much greater extent of crossinterface grain penetration in monolithic fuel plates fabricated by the HIP process. This study documents the outcomes of several strategies attempted to attain this goal. The grain response was characterized using light optical microscopy (LOM) electron backscatter diffraction (EBSD) as a function of these prospective process modifications done to the aluminum prior to the HIP cycle. The strategies included (1) adding macroscopic gaps in the sandwiches to enhance Al flow, (2) adding engineering asperities to enhance Al flow, (3) adding stored energy (cold work), and (4) alternative cleaning and coating. Additionally, two aqueous cleaning methods were compared as baseline control conditions. The results of the preliminary scoping studies in all the categories are presented. In general, none of these approaches were able to obtain >10% grain penetration. Recommended future work includes further development of macroscopic grooving, transferred-arc cleaning, and combinations of these with one another and with other processes.

36 MATERIALS SCIENCE↗

Executive Summary to the AFC Regarding the NEAMS ATF HIP

The DOE through its Nuclear Energy Advanced Modeling and Simulation (NEAMS) program introduced so called High Impact Problems (HIPs). A HIP is intended to make significant advancements in a particular area of nuclear research in a short period of time (3 years or less). The first HIP selected by NEAMS was in the area of Accident Tolerant Fuels (ATF). The purpose of this executive summary is to compile the ATF materials investigated, computational models developed, and key findings of using the models in the engineering scale fuel code developed partially by NEAMS called BISON.

10 SYNTHETIC FUELS↗

Processing, Microstructure, and Properties of Bimetallic Steel-Ni Alloy Powder HIP

This work explores technical feasibility in hot isostatic pressing (HIP) manufacturing of an integral bimetallic component using steel and Ni alloy powder for supercritical carbon dioxide (sCO2) turbomachinery. Lab-scale bimetallic HIP specimens using HAYNES® 282® and SS316L or SS415 powder are investigated in powder configuration, heat treatment, microstructure, and tensile properties up to 400 °C. Interdiffusion profiles at dissimilar alloy interfaces caused by HIP cycle is predicted by DICTRA simulations and validated by electron probe microanalysis (EPMA). The interdiffusion distance of most elements is around 100 μm, while C and N have a higher interdiffusion distance. Dense distribution of Ti-rich carbonitrides and alumina particles are found to decorate prior particle boundaries near joining interface on the 282 side, affecting tensile strength across interface as well as tensile failure location. A higher amount of excessive carbonitride formation near interface is observed in SS316L/282 than in SS415/282, which is consistent with the predicted greater degree of interdiffusion effect in SS316L/282. Typical HAYNES® 282® heat treatment condition is applicable to 282/SS316L and 282/SS415 combinations, resulting in a higher strength than cast CF8M and CA6NM. A pilot-scale bimetallic SS415/282 pipe is then demonstrated to show the promise of scaleup.

36 MATERIALS SCIENCE↗

Microscale wear behavior and crosslinking of PEG-like coatings for total hip replacements

The predominant cause of late-state failure of total hip replacements is wear-mediated osteolysis caused by wear particles that originate from the ultrahigh molecular weight polyethylene (UHMWPE) acetabular cup surface. One strategy for reducing wear particle formation from UHMWPE is to modify the surface with a hydrophilic coating to increase lubrication from synovial fluid. This study focuses on the wear behavior of hydrophilic coatings similar to poly(ethylene glycol) (PEG). The coatings were produced by plasma-polymerizing tetraglyme on UHMWPE in a chamber heated to 40C or 50C. Both temperatures yielded coatings with PEG-like chemistry and increased hydrophilicity relative to uncoated UHMWPE; however, the 40C coatings were significantly more resistant to damage induced by atomic force microscopy nanoscratching. The 40C coatings exhibited only one damage mode (delamination) and often showed no signs of damage after repeated scratching. In contrast, the 50C coatings exhibited three damage modes (roughening, thinning, and delamination), and always showed visible signs of damage after no more than two scratches. The greater wear resistance of the 40C coatings could not be explained by coating chemistry or hydrophilicity, but it corresponded to an approximately 26–32% greater degree of crosslinking relative to the 50C surfaces, suggesting that crosslinking should be a significant design consideration for hydrophilic coatings used for total hip replacements and other wear-dependent applications.

36 MATERIALS SCIENCE↗

Prostate treatment with helical TomoTherapy in patients with bilateral hip prostheses—Two case studies

Prostate cancer patients with bilateral hip prostheses require additional planning and treatment considerations. Visualization of the organs at risk (OAR) and the planning target volume (PTV) is hindered by the large amount of artifact streaking between the metallic implants. The density of this area must be accounted for when using heterogeneity correction. Fusion of a megavolt computed tomography (MVCT) to the planning CT aids in viewing the prostate, bladder, and rectum, and implantation of 6 fiducial markers along the posterior border of the prostate helps with the delineation between it and the rectum. When planning, the amount of beam entry angles is limited because of the position of the prostheses and prevents the use of any lateral beams. Therefore, TomoTherapy presents an effective option for these patients because of the ability to use a directional block, which prevents any primary beams from entering through the bilateral hip prostheses (but the beams may exit through the structures), use of MVCT for daily localization, and delivery of radiation with intensity modulation allows for effective sparing of the OAR.

61 RADIATION PROTECTION AND DOSIMETRY↗

Effects of Prosthesis Stem Tapers on Stress Distribution of Cemented Hip Arthroplasty

Aseptic loosening effects are critical issues in encouraging long term stability of cemented hip arthroplasty. Stress shielding is believed to be an important factor that contributes to the aseptic loosening problems. The numerous changes in the prosthesis stem design are intended to minimize the stress shielding and aseptic loosening problems and to improve the long term performance of the implants. In this study, the stress distribution in cemented hip arthroplasty is established using finite element method. The taper of the prosthesis is designed to be 3 deg. at anterior/posterior, 3 deg. at medial/lateral and 10 deg. from wide lateral to narrow medial. Major muscle loads and contact forces are simulated for walking (toe-off phase) and stair climbing load cases. Effects of prosthesis stem tapers on the resulting stress distribution are investigated. Results show that compressive stress dominates in the medial plane while tensile stress in the lateral plane of the femur. The corresponding stress levels of intact femur for walking and stair-climbing load cases are 22 and 29 MPa, respectively. The magnitude of Tresca stress for the THA femur in stair-climbing load case remains higher in the region of 85 MPa while the walking load case induces around 40 MPa. The stress range in the straight and single taper stem prosthesis is lower than 260 MPa, while localized Tresca stress is in the order of the yield strength of Ti-6Al-4V alloy for double and triple taper stem design.

36 MATERIALS SCIENCE↗

THE LICK-CARNEGIE EXOPLANET SURVEY: A SATURN-MASS PLANET IN THE HABITABLE ZONE OF THE NEARBY M4V STAR HIP 57050

Precision radial velocities (RV) from Keck/HIRES reveal a Saturn-mass planet orbiting the nearby M4V star HIP 57050. The planet has a minimum mass of Msin i {approx} 0.3 M{sub J}, an orbital period of 41.4 days, and an orbital eccentricity of 0.31. V-band photometry reveals a clear stellar rotation signature of the host star with a period of 98 days, well separated from the period of the RV variations and reinforcing a Keplerian origin for the observed velocity variations. The orbital period of this planet corresponds to an orbit in the habitable zone of HIP 57050, with an expected planetary temperature of {approx}230 K. The star has a metallicity of [Fe/H] = 0.32 {+-} 0.06 dex, of order twice solar and among the highest metallicity stars in the immediate solar neighborhood. This newly discovered planet provides further support that the well-known planet-metallicity correlation for F, G, and K stars also extends down into the M-dwarf regime. The a priori geometric probability for transits of this planet is only about 1%. However, the expected eclipse depth is {approx}7%, considerably larger than that yet observed for any transiting planet. Though long on the odds, such a transit is worth pursuing as it would allow for high quality studies of the atmosphere via transmission spectroscopy with Hubble Space Telescope. At the expected planetary effective temperature, the atmosphere may contain water clouds.

79 ASTRONOMY AND ASTROPHYSICS↗

M2K. II. A TRIPLE-PLANET SYSTEM ORBITING HIP 57274

Doppler observations from Keck Observatory have revealed a triple-planet system orbiting the nearby K4V star, HIP 57274. The inner planet, HIP 57274b, is a super-Earth with Msin i = 11.6 M{sub Circled-Plus} (0.036 M{sub Jup}), an orbital period of 8.135 {+-} 0.004 days, and slightly eccentric orbit e = 0.19 {+-} 0.1. We calculate a transit probability of 6.5% for the inner planet. The second planet has Msin i = 0.4 M{sub Jup} with an orbital period of 32.0 {+-} 0.02 days in a nearly circular orbit (e = 0.05 {+-} 0.03). The third planet has Msin i = 0.53 M{sub Jup} with an orbital period of 432 {+-} 8 days (1.18 years) and an eccentricity e = 0.23 {+-} 0.03. This discovery adds to the number of super-Earth mass planets with M sin i < 12 M{sub Circled-Plus} that have been detected with Doppler surveys. We find that 56% {+-} 18% of super-Earths are members of multi-planet systems. This is certainly a lower limit because of observational detectability limits, yet significantly higher than the fraction of Jupiter mass exoplanets, 20% {+-} 8%, that are members of Doppler-detected, multi-planet systems.

79 ASTRONOMY AND ASTROPHYSICS↗

HIP 38939B: A NEW BENCHMARK T DWARF IN THE GALACTIC PLANE DISCOVERED WITH Pan-STARRS1

We report the discovery of a wide brown dwarf companion to the mildly metal-poor ([Fe/H] = -0.24), low Galactic latitude (b = 1.{sup 0}88) K4V star HIP 38939. The companion was discovered by its common proper motion with the primary and its red optical (Pan-STARRS1) and blue infrared (Two Micron All Sky Survey) colors. It has a projected separation of 1630 AU and a near-infrared spectral type of T4.5. As such it is one of only three known companions to a main-sequence star which have early/mid T spectral types of (the others being HN Peg B and {epsilon} Indi B). Using chromospheric activity we estimate an age for the primary of 900{+-}{sup 1900}{sub 600} Myr. This value is also in agreement with the age derived from the star's weak ROSAT detection. Comparison with evolutionary models for this age range indicates that HIP 38939B falls in the mass range 38 {+-} 20 M{sub Jup} with an effective temperature range of 1090 {+-} 60 K. Fitting our spectrum with atmospheric models gives a best-fitting temperature of 1100 K. We include our object in an analysis of the population of benchmark T dwarfs and find that while older atmospheric models appeared to overpredict the temperature of the coolest objects compared to evolutionary models, more recent atmospheric models provide better agreement.

79 ASTRONOMY AND ASTROPHYSICS↗

POSSIBLE IMPLICATIONS OF THE PLANET ORBITING THE RED HORIZONTAL BRANCH STAR HIP 13044

We propose a scenario to account for the surprising orbital properties of the planet orbiting the metal-poor red horizontal branch star HIP 13044. The orbital period of 16.2 days implies that the planet went through a common envelope phase inside the red giant branch (RGB) stellar progenitor of HIP 13044. The present properties of the star imply that it maintained a substantial envelope mass of 0.3 M{sub sun}, raising the question of how the planet survived the common envelope before the envelope itself was lost? If such a planet enters the envelope of an RGB star, it is expected to spiral-in to the very inner region within {approx}< 100 yr, and be evaporated or destroyed by the core. We speculate that the planet was engulfed by the star as a result of the core helium flash that caused this metal-poor star to swell by a factor of {approx}3-4. The evolution following the core helium flash is very rapid, and some of the envelope is lost due to the interaction with the planet, and the rest of the envelope shrinks within about a hundred years. This is about equal to the spiraling-in time, and the planet survived.

79 ASTRONOMY AND ASTROPHYSICS↗

SU-G-IeP2-03: Comparison of Dose Calculation On MAR (metal Artifact Reduction) and Non-MAR Datasets for Pelvic Patients with Hip Prosthesis and Head and Neck Patients with Dental Filling

Purpose: Metal artifact reduction (MAR) software in computed tomography (CT) was previously evaluated with phantoms demonstrating the algorithm is capable of reducing metal artifacts without affecting the overall image quality. The goal of this study is to determine the dosimetric impact when calculating with CT datasets reconstructed with and without MAR software. Methods: Twelve head and neck cancer patients with dental fillings and four pelvic cancer patients with hip prosthesis were scanned with a GE Optima RT 580 CT scanner. Images were reconstructed with and without the MAR software. 6MV IMRT and VMAT plans were calculated with AAA on the MAR dataset until all constraints met our clinic’s guidelines. Contours from the MAR dataset were copied to the non-MAR dataset. Next, dose calculation on the non-MAR dataset was performed using the same field arrangements and fluence as the MAR plan. Conformality index, D99% and V100% to PTV were compared between MAR and non-MAR plans. Results: Differences between MAR and non-MAR plans were evaluated. For head and neck plans, the largest variations in conformality index, D99% and V100% were −3.8%, −0.9% and −2.1% respectively whereas for pelvic plans, the biggest discrepancies were −32.7%, −0.4% and -33.5% respectively. The dosimetric impact from hip prosthesis is greater because it produces more artifacts compared to dental fillings. Coverage to PTV can increase or decrease depending on the artifacts since dark streaks reduce the HU whereas bright streaks increase the HU. In the majority of the cases, PTV dose in the non-MAR plans is higher than MAR plans. Conclusion: With the presence of metals, MAR algorithm can allow more accurate delineation of targets and OARs. Dose difference between MAR and non-MAR plans depends on the proximity of the organ to the high density material, the streaking artifacts and the beam arrangements of the plan.

60 APPLIED LIFE SCIENCES↗