Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HIP”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Herschel Observations of the Debris Disc Around HIP 92043

Context: Typical debris discs are composed of particles ranging from several micron sized dust grains to kilometer-sized asteroidal bodies, and their infrared emission peaks at wavelengths 60-100 microns. Recent Herschel DUNES (Dust Around Nearby Stars) observations have identified several debris discs around nearby Sun-like stars (F, G and K spectral type) with significant excess emission only at 160 microns. Aims: We observed HIP 92043 (110 Her, HD 173667) at far-infrared and sub-millimetre wavelengths with Herschel PACS (Photodetector Array Camera and Spectrometer) and SPIRE (Spectral and Photometric Imaging Receiver).Identification of the presence of excess emission from HIP 92043 and the origin and physical properties of any excess was undertaken through analysis of its spectral energy distribution (SED) and the PACS images. Methods: The PACS and SPIRE images were produced using the HIPE (Herschel Interactive Processing Environment) photProject map maker routine. Fluxes were measured using aperture photometry. A stellar photosphere model was scaled to optical and near infrared photometry and subtracted from the far-infared and sub-mm fluxes to determine the presence of excess emission. Source radial profiles were fitted using a 2D Gaussian and compared to a PSF (Point Spread Function) model based on Herschel observations of alpha Boo to check for extended emission. Results: Clear excess emission from HIP 92043 was observed at 70 and 100 microns. Marginal excess was observed at 160 and 250 microns.Analysis of the images reveals that the source is extended at 160 microns. A fit to the source SED is inconsistent with a photosphere and single temperature black body. Conclusions: The excess emission from HIP 92043 is consistent with the presence of an unresolved circumstellar debris disc at 70and 100 microns, with low probability of background contamination. The extended 160 micron emission may be interpreted as an additional cold component to the debris disc or as the result of background contamination along the line of sight. The nature of the 160 micron excess cannot be determined absolutely from the available data, but we favour a debris disc interpretation, drawing parallels with previously identified cold disc sources in the DUNES sample.

debris discs↗

Hiding-in-Plain-Sight (HiPS) Attack on CLIP for Targetted Object Removal from Images

Machine learning models are known to be vulnerable to adversarial attacks, but prior works have mostly focused on single-modalities. With the rise of large multi-modal models (LMMs) like CLIP, which combine vision and language capabilities, new vulnerabilities have emerged. However, these multimodal targeted attacks aim to completely change the model's output to what the adversary wants. In many realistic scenarios, an adversary might seek to make only subtle modifications to the output, so that the changes go unnoticed by downstream models or even by humans. We introduce Hiding-in-Plain-Sight (HiPS) attacks, a novel class of adversarial attacks that subtly modifies model predictions by selectively concealing target object(s), as if the target object was absent from the scene. We propose two HiPS attack variants, HiPS-cls and HiPS-cap, and demonstrate their effectiveness in transferring to downstream image captioning models, such as CLIP-Cap, for targeted object removal from image captions.

Daw, Arka [ORNL] (ORCID:0009000633191271)↗

A comparative study on the physicochemical characteristics of nanoparticles released in vivo from CoCrMo tapers and cement–stem interfaces of total hip replacements

The good biocompatibility and corrosion resistance of the bulk CoCrMo alloy has resulted in it being used in the manufacture of implants and load bearing medical devices. These devices, however, can release wear and corrosion products which differ from the composition of the bulk CoCrMo alloy. The physicochemical characteristics of the particles and the associated in vivo reactivity are dictated by the wear mechanisms and electrochemical conditions at the sites of material loss. Debris released from CoCrMo hip bearings, taper junctions, or cement–stem interfaces can, therefore, have different chemical and morphological characteristics, which provide them with different in vivo toxicities. Here, we propose to assess and compare the characteristics of the particles released in vivo from CoCrMo tapers and cement–stem interfaces which have received less attention compared to debris originating from the hip bearings. The study uses state–of–art characterization techniques to provide a detailed understanding of the size, morphology, composition, and chemistry of the particles liberated from the wear and corrosion flakes from revised hip replacements, with an enzymatic treatment. The phase analyses identified Cr 2 O 3 nanoparticles released from tapers and cement–stem interfaces, whose composition did not vary with origin or particle morphology. The size distributions showed significantly smaller particles were released from the stems, compared to the particles originating from the corresponding tapers. Furthermore, the investigation demonstrates that the tribocorrosive processes occurring at the taper and stem interfaces both result in Cr 2 O 3 nanoparticle formation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Consolidation of iodine-loaded Ag 0 -functionalized silica aerogel with HUP, HIP and SPS

The U.S. Department of Energy is currently investigating alternative sorbents for the removal and immobilization of radioiodine from the gas streams in a nuclear fuel reprocessing plant. One of these new sorbents, silver-functionalized silica aerogel (Ag 0 -aerogel), shows promise as a potential replacement for silver mordenite because of its high selectivity and sorption capacity for iodine. Moreover, a feasible consolidation of iodine-loaded Ag 0 -aerogel to a durable SiO 2 -based waste form makes this aerogel an attractive choice for sequestering radioiodine. The main purpose of the study reported here was to investigate consolidation of Ag 0 -aerogel powders with or without iodine and with or without sintering additives with hot uniaxial pressing (HUP), HIP, and SPS. The selected densified samples were analyzed with a helium gas pycnometer for apparent density, with the Archimedes method for open porosity and apparent density, with scanning electron microscopy and energy dispersive spectroscopy (SEM-EDS) for the extent of densification, macro- and microstructural changes, and distribution of individual elements, and with X-ray diffraction (XRD) for crystalline phases. To convert the iodine-loaded Ag 0 -silica aerogel to a waste form, rapid consolidation with HUP, HIP, and SPS at moderate temperatures and pressures yields a final waste form consisting of AgI particles encapsulated in fused silica. HUP-processing (1200°C for 30 min under 29 MPa pressure) of Ag 0 -aerogel loaded with 20.2 mass% of iodine provided a product with residual open porosity of 16.9%. However, ~93% of sorbed iodine was retained in the sintered material. Densification with HIP at 1200°C for 30 min under 207 MPa pressure resulted in a fully dense silica-based waste form of 3.3 $\times$ 10 3 kg/m 3 bulk density containing ~22 mass% of iodine. Iodine was retained in the form of nano- and micro-inclusions of AgI dispersed in the silica matrix. Additives were not needed to enhance sintering process as depicted from the lack of open porosity and 100% retention of iodine in the consolidated product. The future tests will tell whether additives such as raw silica aerogel or Ag 0 -aerogel are required for HIPing to produce a fully dense waste form from iodine-loaded Ag 0 -aerogel containing higher concentrations of captured iodine. SPS-processing of samples with or without iodine revealed a benefit of additive-enhanced sintering. The samples containing additives (raw silica aerogel, colloidal silica, and Ag 0 -aerogel) shrunk faster and at lower temperatures. In addition, additives significantly improved distribution of silver compounds in the fully densified products, considerably decreasing the number of micron-sized inclusions of AgI, Ag and Ag 2 S at the grain boundaries.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Near-Net-Shape HIP Manufacturing for sCO2 Turbomachinery Cost Reduction

sCO2 turbomachinery that operates above 650°C requires the use of γ' strengthened Ni-based superalloys, leading to high cost and barrier of market adoption. Near-net-shape (NNS) HIP manufacturing with 282® alloy powder is being developed for sCO2 turbine components, with a significant estimated cost reduction. Tensile, creep, low cycle fatigue properties of argon gas atomized and plasma atomized powders were evaluated and compared to sand cast HAYNES® 282®. While tensile strength and fatigue life outperformed sand cast material, a 10~25% debit in the creep stress capability was observed due to the fine grain size and presence of prior particle boundaries (PPBs). Finite element model calibrated by powder rheological properties accurately predicted the nonuniform shrinkage during HIP, providing HIP tooling design to achieve the target dimension. A 20 lbs. turbine nozzle ring was successfully demonstrated within 0.01 inch dimensional tolerance at the vanes. A 1700lbs. turbine casing with complex internal struts and manifolds was also demonstrated being close to the target dimension.

14 SOLAR ENERGY↗

Perioperative Timing of Infliximab and the Risk of Serious Infection After Elective Hip and Knee Arthroplasty

Objective The optimal timing of tumor necrosis factor antagonists before elective surgery is unknown. This study evaluated the association between infliximab timing and serious infection after elective hip or knee arthroplasty. Methods A retrospective cohort study evaluated US Medicare patients with rheumatoid arthritis, inflammatory bowel disease, psoriasis, psoriatic arthritis, or ankylosing spondylitis who received infliximab within 6 months of elective knee or hip arthroplasty from 2007 to 2013. Propensity‐adjusted analyses examined whether infliximab stop timing (time between the most recent infusion and surgery) was associated with hospitalized infection within 30 days or prosthetic joint infection ( PJI ) within 1 year. Results Hospitalized infection within 30 days occurred after 270 of 4,288 surgeries (6.3%). Infliximab stop timing <4 weeks versus 8–12 weeks was not associated with an increase in infection within 30 days (propensity‐adjusted odds ratio [ OR ] 0.90 [95% confidence interval (95% CI ) 0.60–1.34]). The rate of PJI was 2.9 per 100 person‐years and was not increased in patients with stop timing <4 weeks versus 8–12 weeks (hazard ratio [ HR ] 0.98 [95% CI 0.52–1.87]). Glucocorticoid dosage >10 mg/day was associated with increased risk of 30‐day infection ( OR 2.11 [95% CI 1.30–3.40]) and PJI ( HR 2.70 [95% CI 1.30–5.60]). Other risk factors for infection included elderly age, comorbidities, revision surgery, and previous hospitalized infection. Conclusion Administering infliximab within 4 weeks of elective knee or hip arthroplasty was not associated with a higher risk of short‐ or long‐term serious infection compared to withholding infliximab for longer time periods. Glucocorticoid use, especially >10 mg/day, was associated with an increased infection risk.

George, Michael D.↗

Microstructure characteristics of LPBF&HIP fabricated graded composite transition joint between ferritic steel and austenitic stainless steel

Graded composite transition joints (GCTJs) offer a promising alternative to conventional dissimilar metal welds (DMWs) by enabling smooth compositional and microstructural transitions. However, GCTJs fabricated solely through additive manufacturing (AM) face challenges such as heat accumulation, complex parameter control, and elemental segregation. In this study, we propose a novel approach that relies on AM to design a spatially graded structure in one alloy and then employs hot isostatic pressing (HIP) as a diffusion bonding method to join it with a second alloy. Here, this method combines the flexibility of AM with the powder net-shaping advantage of HIP. Specifically, a series of closely packed austenitic stainless steel 304 conical structures were printed using laser powder bed fusion (LPBF) and then combined with ferritic steel P91 powder via HIP. By using electron backscatter diffraction (EBSD), electron probe microanalysis (EPMA), and transmission electron microscopy (TEM) techniques, the microstructure characteristics of the GCTJ of 304&P91, especially the interdiffusion zone (IDZ), have been systematically investigated. The microstructure at the interface transitions from austenite-ferrite (A+F) to austenite-martensite-ferrite (A+M+F), and finally to martensite-ferrite (M+F) due to diffusion. Additionally, the diffusion width between 304 and P91 increases with the volume fraction of P91. This unique design also ensures a gradual transition in both hardness and thermal expansion coefficient from 304 to P91, thereby enabling a smooth gradient in functional properties. Overall, this study proposes a novel approach for fabricating GCTJs and contributes to advancing design concepts in the field of dissimilar metal joining.

Additively manufacturing (AM)↗

Enhancing the tensile properties of EBM as-built thin parts: Effect of HIP and chemical etching

Highlights: • The EBM process leads to important cross section variations in thin parts. • Stress calculation must be based on the average section in order to be relevant. • As-built state has a detrimental effect on every mechanical property. • Mechanical properties of machined samples are met with chemical etching. • HIP has a beneficial effect on the ductility. - Abstract: As-built Ti-6Al-4 V thin parts were manufactured using Electron Beam Melting (EBM) and characterized by optical microscopy and laboratory X-ray tomography in order to observe their microstructure, pore distribution and surface aspect. Chemical etching and HIP post-treatments were applied to as-built samples and their effect on the material and static mechanical properties were studied. Tensile tests were performed on both as-built and post-treated samples and their results compared to the ones reported in the literature for machined EBM samples. Because of the significant variations of the cross section observed along the gauge length, the calculation of the tensile stresses is not straightforward. Three simple sections were measured from the tomography scans. The average section along the gauge length was considered as the most suitable. The tensile mechanical properties of the as-built samples were studied and a detrimental effect of the surface state on the yield strength, ultimate tensile strength and elongation to failure was observed. Smoothing of the surface irregularities induced by chemical etching provoked an increase of those mechanical properties whereas the change of the microstructure generated by the HIP treatment leads to a decrease of the material strength that goes along with an increase of the ductility. Down scaling factors were proposed in order to take into account the sample state, as-built or post-treated.

36 MATERIALS SCIENCE↗

Intensity-Modulated Radiation Therapy with Noncoplanar Beams for Treatment of Prostate Cancer in Patients with Bilateral Hip Prosthesis-A Case Study

Megavoltage photon intensity-modulated radiation therapy (IMRT) is typically used in the treatment of prostate cancer at our institution. Approximately 1% to 2% of patients with prostate cancer have hip prostheses. The presence of the prosthesis usually complicates the planning process because of dose perturbation around the prosthesis, radiation attenuation through the prosthesis, and the introduction of computed tomography artifacts in the planning volume. In addition, hip prostheses are typically made of materials of high atomic number, which add uncertainty to the dosimetry of the prostate and critical organs in the planning volume. When the prosthesis is bilateral, treatment planning is further complicated because only a limited number of beam angles can be used to avoid the prostheses. In this case study, we will report the observed advantages of using noncoplanar beams in the delivery of IMRT to a prostate cancer patient with bilateral hip prostheses. The treatment was planned for 75.6 Gy using a 7-field coplanar approach and a noncoplanar arrangement, with all fields avoiding entrance though the prostheses. Our results indicate that, compared with the coplanar plan, the noncoplanar plan delivers the prescribed dose to the target with a slightly better conformality and sparing of rectal tissue versus the coplanar plan.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coplanar intensity-modulated radiotherapy class solution for patients with prostate cancer with bilateral hip prostheses with and without nodal involvement

Dose distributions for prostate radiotherapy are difficult to predict in patients with bilateral hip prostheses in situ, due to image distortions and difficulty in dose calculation. The feasibility of delivering curative doses to prostate using intensity-modulated radiotherapy (IMRT) in patients with bilateral hip prostheses was evaluated. Planning target volumes for prostate only (PTV1) and pelvic nodes (PTV2) were generated from data on 5 patients. PTV1 and PTV2 dose prescriptions were 70 Gy and 60 Gy, respectively, in 35 fractions, and an additional nodal boost of 65 Gy was added for 1 plan. Rectum, bladder, and bowel were also delineated. Beam angles and segments were chosen to best avoid entering through the prostheses. Dose-volume data were assessed with respect to clinical objectives. The plans achieved the required prescription doses to the PTVs. Five-field IMRT plans were adequate for patients with relatively small prostheses (head volumes<60 cm{sup 3}) but 7-field plans were required for patients with larger prostheses. Bowel and bladder doses were clinically acceptable for all patients. Rectal doses were deemed clinically acceptable, although the V{sub 50} {sub Gy} objective was not met for 4/5 patients. We describe an IMRT solution for patients with bilateral hip prostheses of varying size and shape, requiring either localized or whole pelvic radiotherapy for prostate cancer.

61 RADIATION PROTECTION AND DOSIMETRY↗

Correlation between Interface Microstructure and Bond Strength of Al6061/Al6061 HIP-Bonded Plates for Fuel Cladding Application

The effects of hot isostatic pressing (HIP) processing parameters on microstructure and bond strength of Al6061/Al6061 plate interfaces were systemically investigated at the micro- and nanoscale. The HIP bonding of the two aluminum plates was performed at four temperatures: 350°C, 400°C, 450°C, and 560°C. The results reveal the formation of micron scaled Mg 2 Si precipitate and uniform nano scaled Mg 2 Al 2 O 5 oxide at the interface. The formation of Mg 2 Al 2 O 5 is closely associated with the fast bulk diffusion of Mg from the Al matrix to the amorphous Al 2 O 3 /Al interface and subsequent reaction between Mg and Al 2 O 3 . Finally, the highest and lowest bond strengths were observed in samples HIP bonded at 450°C and 350°C, respectively.

36 MATERIALS SCIENCE↗

CHARACTERIZING K2 PLANET DISCOVERIES: A SUPER-EARTH TRANSITING THE BRIGHT K DWARF HIP 116454

We report the first planet discovery from the two-wheeled Kepler (K2) mission: HIP 116454 b. The host star HIP 116454 is a bright (V = 10.1, K = 8.0) K1 dwarf with high proper motion and a parallax-based distance of 55.2 ± 5.4 pc. Based on high-resolution optical spectroscopy, we find that the host star is metal-poor with [Fe/H] =–0.16 ± 0.08 and has a radius R {sub *} = 0.716 ± 0.024 R {sub ☉} and mass M {sub *} = 0.775 ± 0.027 M {sub ☉}. The star was observed by the Kepler spacecraft during its Two-Wheeled Concept Engineering Test in 2014 February. During the 9 days of observations, K2 observed a single transit event. Using a new K2 photometric analysis technique, we are able to correct small telescope drifts and recover the observed transit at high confidence, corresponding to a planetary radius of R{sub p} = 2.53 ± 0.18 R {sub ⊕}. Radial velocity observations with the HARPS-N spectrograph reveal a 11.82 ± 1.33 M {sub ⊕} planet in a 9.1 day orbit, consistent with the transit depth, duration, and ephemeris. Follow-up photometric measurements from the MOST satellite confirm the transit observed in the K2 photometry and provide a refined ephemeris, making HIP 116454 b amenable for future follow-up observations of this latest addition to the growing population of transiting super-Earths around nearby, bright stars.

79 ASTRONOMY AND ASTROPHYSICS↗

Automated generation of IMRT treatment plans for prostate cancer patients with metal hip prostheses: Comparison of different planning strategies

Purpose: To compare IMRT planning strategies for prostate cancer patients with metal hip prostheses.Methods: All plans were generated fully automatically (i.e., no human trial-and-error interactions) using iCycle, the authors' in-house developed algorithm for multicriterial selection of beam angles and optimization of fluence profiles, allowing objective comparison of planning strategies. For 18 prostate cancer patients (eight with bilateral hip prostheses, ten with a right-sided unilateral prosthesis), two planning strategies were evaluated: (i) full exclusion of beams containing beamlets that would deliver dose to the target after passing a prosthesis (IMRT{sub remove}) and (ii) exclusion of those beamlets only (IMRT{sub cut}). Plans with optimized coplanar and noncoplanar beam arrangements were generated. Differences in PTV coverage and sparing of organs at risk (OARs) were quantified. The impact of beam number on plan quality was evaluated.Results: Especially for patients with bilateral hip prostheses, IMRT{sub cut} significantly improved rectum and bladder sparing compared to IMRT{sub remove}. For 9-beam coplanar plans, rectum V{sub 60Gy} reduced by 17.5%{+-} 15.0% (maximum 37.4%, p= 0.036) and rectum D{sub mean} by 9.4%{+-} 7.8% (maximum 19.8%, p= 0.036). Further improvements in OAR sparing were achievable by using noncoplanar beam setups, reducing rectum V{sub 60Gy} by another 4.6%{+-} 4.9% (p= 0.012) for noncoplanar 9-beam IMRT{sub cut} plans. Large reductions in rectum dose delivery were also observed when increasing the number of beam directions in the plans. For bilateral implants, the rectum V{sub 60Gy} was 37.3%{+-} 12.1% for coplanar 7-beam plans and reduced on average by 13.5% (maximum 30.1%, p= 0.012) for 15 directions.Conclusions: iCycle was able to automatically generate high quality plans for prostate cancer patients with prostheses. Excluding only beamlets that passed through the prostheses (IMRT{sub cut} strategy) significantly improved OAR sparing. Noncoplanar beam arrangements and, to a larger extent, increasing the number of treatment beams further improved plan quality.

61 RADIATION PROTECTION AND DOSIMETRY↗

Cancer risk estimates from radiation therapy for heterotopic ossification prophylaxis after total hip arthroplasty

Purpose: Heterotopic ossification (HO) is a frequent complication following total hip arthroplasty. This study was conducted to calculate the radiation dose to organs-at-risk and estimate the probability of cancer induction from radiotherapy for HO prophylaxis.Methods: Hip irradiation for HO with a 6 MV photon beam was simulated with the aid of a Monte Carlo model. A realistic humanoid phantom representing an average adult patient was implemented in Monte Carlo environment for dosimetric calculations. The average out-of-field radiation dose to stomach, liver, lung, prostate, bladder, thyroid, breast, uterus, and ovary was calculated. The organ-equivalent-dose to colon, that was partly included within the treatment field, was also determined. Organ dose calculations were carried out using three different field sizes. The dependence of organ doses upon the block insertion into primary beam for shielding colon and prosthesis was investigated. The lifetime attributable risk for cancer development was estimated using organ, age, and gender-specific risk coefficients.Results: For a typical target dose of 7 Gy, organ doses varied from 1.0 to 741.1 mGy by the field dimensions and organ location relative to the field edge. Blocked field irradiations resulted in a dose range of 1.4–146.3 mGy. The most probable detriment from open field treatment of male patients was colon cancer with a high risk of 564.3 × 10{sup −5} to 837.4 × 10{sup −5} depending upon the organ dose magnitude and the patient's age. The corresponding colon cancer risk for female patients was (372.2–541.0) × 10{sup −5}. The probability of bladder cancer development was more than 113.7 × 10{sup −5} and 110.3 × 10{sup −5} for males and females, respectively. The cancer risk range to other individual organs was reduced to (0.003–68.5) × 10{sup −5}.Conclusions: The risk for cancer induction from radiation therapy for HO prophylaxis after total hip arthroplasty varies considerably by the treatment parameters, organ site in respect to treatment volume and patient's gender and age. The presented risk estimates may be useful in the follow-up studies of irradiated patients.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-504: Usefulness of CT-MR Fusion in Radiotherapy Planning for Prostate Cancer Patient with Bilateral Hip Replacements

Purpose: Target localization of prostate for Intensity Modulated Radiation Therapy (IMRT) in patients with bilateral hip replacements is difficult due to artifacts in Computed Tomography (CT) images generated from the prostheses high Z materials. In this study, Magnetic Resonance (MR) images fused with CT images are tested as a solution. Methods: CT images of 2.5 mm slice thickness were acquired on a GE Lightspeed scanner with a flat-topped couch for a prostate cancer patient with bilateral hip replacements. T2 weighted images of 5 mm separation were acquired on a MR Scanner. After the MR-CT registration on a radiotherapy treatment planning system (Eclipse, Varian), the target volumes were defined by the radiation oncologists on MR images and then transferred to CT images for planning and dose calculation. The CT Hounsfield Units (HU) was reassigned to zero (as water) for artifacts. The Varian flat panel treatment couch was modeled for dose calculation accuracy with heterogeneity correction. A Volume Matrix Arc Therapy (VMAT) and a seven-field IMRT plans were generated, each avoiding any beam transversing the prostheses; the two plans were compared. The superior VMAT plan was used for treating the patient. In-vivo dosimetry was performed using MOSFET (Best Canada) placed in a surgical tube inserted into the patient rectum during therapy. The measured dose was compared with planned dose for MOSFET location. Results: The registration of MR-CT images and the agreement of target volumes were confirmed by three physicians. VMAT plan was deemed superior to IMRT based on dose to critical nearby structures and overall conformality of target dosing. In-vivo measured dose compared with calculated dose was -4.5% which was likely due to attenuation of the surgical tube surrounding MOSFET. Conclusion: When artifacts are present on planning CT due to bilateral hip prostheses, MR-CT image fusion is a feasible solution for target delineation.

60 APPLIED LIFE SCIENCES↗

SU-F-T-374: Dosimetric Effects of Irradiation Through a Bilateral Hip Prosthesis in a MRI Linac

Purpose: To evaluate the interface effects when irradiating through a hip prosthesis in the presence of an orthogonal 1.5 T magnetic field using Monte Carlo simulations. Methods: A 20×20×38 cm virtual phantom with two 5×5×5 cm sections of bilateral titanium hip prosthesis was created in GPU-based Monte Carlo (MC) algorithm (GPUMCD, Elekta AB, Stockholm Sweden). The lateral prosthesis spacing was based on a representative patient CT scan. A treatment SAD of 143.5 cm was chosen, corresponding to the Elekta AB MRI Linac and the beam energy distribution was sampled from a histogram representing the true MRI Linac spectrum. A magnetic field of 1.5 T was applied perpendicular to the plane of irradiation. Dose was calculated, in voxels of side 1 mm, for 2×2, 5×5, and 10×10 cm treatment field sizes with normal beam incidence (gantry at 90° or 270°) and at 5° and 10° from normal, representing the range of incidence through the bilateral prosthesis. Results: With magnetic field ON (B-On) and normal beam incidence the backscatter dose at the interfaces of proximal and distal implants is reduced for all the field sizes compared to the magnetic field OFF (B-Off) case. The absolute reduction in doses at the interface was in the range of 12.93% to 13.16% for the proximal implant and 13.57% to 16.12% for the distal implant. Similarly for the oblique incidences of 5o and 10o the dose in the plane adjacent to the prosthetic implants is lower when the magnetic field is ON. Conclusion: The dosimetric effects of irradiating through a hip prosthesis in the presence of a transverse magnetic field have been determined using MC simulation. The backscatter dose reduction translates into significantly lower hot spots at the prosthetic interfaces, which are otherwise substantially high in the absence of the magnetic field. This project was supported through funding provided by ElektaTM.

60 APPLIED LIFE SCIENCES↗

Canless HIP Development for Aluminum Cladding of LEU Fuel Foils using Electron Beam Welding

The conventional canning method for HIP processing of fuel foils requires that foil assemblies be stacked within a stainless steel can, which is then welded shut and the internal air evacuated. A few of the detracting aspects associated with this method include i) the time required to hand construct and disassemble each can, ii) the possibility for bonding between adjacent foil assemblies and backing plates, and iii) the generation of large volumes of contaminated waste (can material and backing plates) that must be disposed. The new “canless” HIP approach discussed in this report involves the hermetic sealing of individual foil assemblies by electron beam welding their outer perimeter. A foil assembly consists of a zirconium-clad LEU (U-10Mo) foil sandwiched between two aluminum 6061 plates. Hermetic sealing is accomplished by making 4 intersecting aluminum-to-aluminum, full-penetration lap welds as shown in Figure 1. Since welds are made in a hard vacuum (10-5 torr), there is no need for a separate air evacuation step. The fuel itself sits within a pocket machined into one of the aluminum plates. Multiple foil assemblies welded in this manner can then be placed in a HIP fixture and batch processed.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Improving 6061-Al Grain Growth and Penetration across HIP-Bonded Clad Interfaces in Monolithic Fuel Plates: Initial Studies

Grain penetration across aluminum-aluminum cladding interfaces in research reactor fuel plates is desirable and was obtained by a legacy roll-bonding process, which attained 20-80% grain penetration. Significant grain penetration in monolithic fuel plates produced by Hot Isostatic Press (HIP) fabrication processing is equally desirable but has yet to be attained. The goal of this study was to modify the 6061-Al in such a way as to promote a much greater extent of crossinterface grain penetration in monolithic fuel plates fabricated by the HIP process. This study documents the outcomes of several strategies attempted to attain this goal. The grain response was characterized using light optical microscopy (LOM) electron backscatter diffraction (EBSD) as a function of these prospective process modifications done to the aluminum prior to the HIP cycle. The strategies included (1) adding macroscopic gaps in the sandwiches to enhance Al flow, (2) adding engineering asperities to enhance Al flow, (3) adding stored energy (cold work), and (4) alternative cleaning and coating. Additionally, two aqueous cleaning methods were compared as baseline control conditions. The results of the preliminary scoping studies in all the categories are presented. In general, none of these approaches were able to obtain >10% grain penetration. Recommended future work includes further development of macroscopic grooving, transferred-arc cleaning, and combinations of these with one another and with other processes.

36 MATERIALS SCIENCE↗