Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “HEPA Filter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Technical analysis of filter testing at the U.S. Department of Energy Filter Test Facility

The U.S. Department of Energy (DOE) technical standard DOE-STD-3020-2015 requires verification testing at the Filter Test Facility (FTF) of high-efficiency particulate air (HEPA) filters to be installed in nuclear facility (Hazard Category 1, 2, 3, and radiological facilities) confinement ventilation systems, or to be installed in habitability systems (e.g., filters for protection of workers required to act for the control and mitigation of emergency situations). Filters in these applications perform a safety function in accident situations, are designated as important to safety, or are necessary for habitability systems. Different FTFs have operated for decades, and results of tests are available to examine the need for and benefits of continued execution of 100 percent QA verification testing. The objective of this study and resulting report was to assess the need for 100 percent QA testing at the current FTF in Maryland, based on an examination of a database of test results from 2013 to August 2020. Filters that require independent testing per DOE-STD-3020-2015 to be installed in nuclear facilities are sent to the FTF before being shipped to the facilities. The FTF examines the documentation (e.g., certificates of compliance, results of particle penetration and airflow resistance testing by the manufacturers, labels affixed to filters and packages, and other requirements specified in purchase orders by the nuclear facility operators), implements visual inspections of the physical state of the filters, and checks the dimensions of frames. Filters that meet the documentation and visual inspection requirements are subjected to particle penetration and airflow resistance testing. In case of rejections, the filters are shipped back to the manufacturers, at the cost of the manufacturers, for replacement. Filters that pass all tests are shipped to the nuclear facilities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hybrid Filter Membrane

Cabin environmental control is an important issue for a successful Moon mission. Due to the unique environment of the Moon, lunar dust control is one of the main problems that significantly diminishes the air quality inside spacecraft cabins. Therefore, this innovation was motivated by NASA s need to minimize the negative health impact that air-suspended lunar dust particles have on astronauts in spacecraft cabins. It is based on fabrication of a hybrid filter comprising nanofiber nonwoven layers coated on porous polymer membranes with uniform cylindrical pores. This design results in a high-efficiency gas particulate filter with low pressure drop and the ability to be easily regenerated to restore filtration performance. A hybrid filter was developed consisting of a porous membrane with uniform, micron-sized, cylindrical pore channels coated with a thin nanofiber layer. Compared to conventional filter media such as a high-efficiency particulate air (HEPA) filter, this filter is designed to provide high particle efficiency, low pressure drop, and the ability to be regenerated. These membranes have well-defined micron-sized pores and can be used independently as air filters with discreet particle size cut-off, or coated with nanofiber layers for filtration of ultrafine nanoscale particles. The filter consists of a thin design intended to facilitate filter regeneration by localized air pulsing. The two main features of this invention are the concept of combining a micro-engineered straight-pore membrane with nanofibers. The micro-engineered straight pore membrane can be prepared with extremely high precision. Because the resulting membrane pores are straight and not tortuous like those found in conventional filters, the pressure drop across the filter is significantly reduced. The nanofiber layer is applied as a very thin coating to enhance filtration efficiency for fine nanoscale particles. Additionally, the thin nanofiber coating is designed to promote capture of dust particles on the filter surface and to facilitate dust removal with pulse or back airflow.

Laicer, Castro↗

Summary of Martian Dust Filtering Challenges and Current Filter Development

Traditional air particulate filtering in manned spaceflight (Apollo, Shuttle, ISS, etc.) has used cleanable or replaceable catch filters such as screens and High-Efficiency Particulate Arrestance (HEPA) filters. However, the human mission to Mars architecture will require a new approach. It is Martian dust that is the particulate of concern but the need also applies to particulates generated by crew. The Mars Exploration Program Analysis Group (MEPAG) high-lighted this concern in its Mars Science, Goals, Objectives, Investigations and Priorities document [7], by saying specifically that one high priority investigation will be to "Test ISRU atmospheric processing systems to measure resilience with respect to dust and other environmental challenge performance parameters that are critical to the design of a full-scale system." By stating this as high priority the MEPAG is acknowledging that developing and adequately verifying this capability is critical to success of a human mission to Mars. This architecture will require filtering capabilities that are highly reliable, will not restrict the flow path with clogging, and require little to no maintenance. This paper will summarize why this is the case, the general requirements for developing the technology, and the status of the progress made in this area.

O'Hara, William J., IV↗

Submicron and Nanoparticulate Matter Removal by HEPA-Rated Media Filters and Packed Beds of Granular Materials

Contaminants generated aboard crewed spacecraft by diverse sources consist of both gaseous chemical contaminants and particulate matter. Both HEPA media filters and packed beds of granular material, such as activated carbon, which are both commonly employed for cabin atmosphere purification purposes have efficacy for removing nanoparticulate contaminants from the cabin atmosphere. The phenomena associated with particulate matter removal by HEPA media filters and packed beds of granular material are reviewed relative to their efficacy for removing fine (less than 2.5 micrometers) and ultrafine (less than 0.01 micrometers) sized particulate matter. Considerations are discussed for using these methods in an appropriate configuration to provide the most effective performance for a broad range of particle sizes including nanoparticulates.

Perry, J. L.↗

International Space Station Bacteria Filter Element Post-Flight Testing and Service Life Prediction

The International Space Station uses high efficiency particulate air (HEPA) filters to remove particulate matter from the cabin atmosphere. Known as Bacteria Filter Elements (BFEs), there are 13 elements deployed on board the ISS's U.S. Segment. The pre-flight service life prediction of 1 year for the BFEs is based upon performance engineering analysis of data collected during developmental testing that used a synthetic dust challenge. While this challenge is considered reasonable and conservative from a design perspective, an understanding of the actual filter loading is required to best manage the critical ISS Program resources. Thus testing was conducted on BFEs returned from the ISS to refine the service life prediction. Results from this testing and implications to ISS resource management are discussed. Recommendations for realizing significant savings to the ISS Program are presented.

Perry, J. L.↗

Current Activities in the Advanced Exploration Systems ISRU Project

Media Filter MOXIE support: completed flow performance tests and initial dust loading tests of the MOXIE HEPA filter in the Mars Flow Loop Designed and fabricated prototype full-scale scroll filter for testing of renewable filter performance Mars Flow Loop upgrades: installed more sensitive instrumentation, improved imaging, and increased run duration capability Electrostatic Precipitator (ESP) Plasma-physics based model predicts particle charge and trajectory Characterizing dust environment from fluidized-bed injection dust environment using laser sheet visualization and Fine Particle Analyzer Sabatier Design Study Defined the Sabatier design space, including reactor type, thermal management, gas recycling/separation Modeled Sabatier systems with one or two reactors with different types of thermal management Adding thermal management schemes and recycling and gas separation to model Catalyst Screening Performing compression testing on new and used catalyst pellets Performing vibration testing on different catalyst pellet types under different load conditions Preparing to test catalysts for performance and degradation

In-Situ Resource Utilization↗

Assembly Operations Welding Filter(s) in Drum Calculation

This calculation documents the estimation of temperature and pressure rise inside a 55-gal TRU waste drum with a HEPA filter containing Titanium and Tantalum fume dust based on operational history.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Assembly Operations Welding Filter(s) in Drum Calculation

This calculation documents the estimation of temperature and pressure rise inside a 55-gal TRU waste drum with a HEPA filter containing Titanium and Tantalum fume dust based on operational history. Actual Titanium values are believed to be less than 10g on any given filter. Actual Tantalum values are believed to be less than 1g on any given filter

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Code Standard Evaluation for ASME AG-1-2019, Section FL

ASME AG-1 Section FL Deep Bed Sand Filters includes a requirement to use Special Test Sections to provide a representative assessment of the filter efficiency. The SRPPF project design basis is to test the entire filter bed (versus a representative sample) following the same basis methodology to test the existing filters at the Savannah River Site. Using a combination of: 1) the filter testing experience at SRS since the early 1970’s, 2) the methodology found in ASME AG-1 for testing high capacity HEPA filter housings and 3) requirements for stack or duct sampling systems published by the Environmental Protection Agency (EPA), the Special Test Sections methodology for Deep Bed Sand (DBS) filters in ASME AG-1 Section FL has been replaced with a methodology to test the entire DBS filter system.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Filter Efficiency and Pressure Testing of Returned ISS Bacterial Filter Elements (BFEs)

The air quality control equipment aboard the International Space Station (ISS) and future deep space exploration vehicles provide the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation. The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Air (HEPA) filters deployed at multiple locations in each U.S. Seg-ment module; these filters are referred to as Bacterial Filter Elements, or BFEs. In our previous work, we presented results of efficiency and pressure drop measurements for a sample set of two returned BFEs with a service life of 2.5 years. In this follow-on work, we present similar efficiency, pressure drop, and leak tests results for a larger sample set of six returned BFEs. The results of this work can aid the ISS Program in managing BFE logistics inventory through the stations planned lifetime as well as provide insight for managing filter element logistics for future exploration missions. These results also can provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.

ISS Air Quality↗

Development of Test Protocols for International Space Station Particulate Filters

Air quality control on the International Space Station (ISS) is a vital requirement for maintaining a clean environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of gravitational settling. The ISS Environmental Control and Life Support System (ECLSS) uses a filtration system that has been in use for over 14 years and has proven to meet this challenge. The heart of this system is a traditional High-Efficiency Particulate Air (HEPA) filter configured to interface with the rest of the life support elements and provide effective cabin filtration. The filter element for this system has a non-standard cross-section with a length-to-width ratio (LW) of 6.6. A filter test setup was designed and built to meet industry testing standards. A CFD analysis was performed to initially determine the optimal duct geometry and flow configuration. Both a screen and flow straighter were added to the test duct design to improve flow uniformity and face velocity profiles were subsequently measured to confirm. Flow quality and aerosol mixing assessments show that the duct flow is satisfactory for the intended leak testing. Preliminary leak testing was performed on two different ISS filters, one with known perforations and one with limited use, and results confirmed that the testing methods and photometer instrument are sensitive enough to detect and locate compromised sections of an ISS BFE.Given the engineering constraints in designing spacecraft life support systems, it is anticipated that non-industry standard filters will be required in future designs. This work is focused on developing test protocols for testing the ISS BFE filters, but the methodology is general enough to be extended to other present and future spacecraft filters. These techniques for characterizing the test duct and perform leak testing can be applied to conducting acceptance testing and inventory testing for future manned exploration programs with air revitalization filtration needs, possibly even for in-situ filter element integrity testing for extensively long-duration missions. We plan to address the unique needs for test protocols for crewed spacecraft particulate filters by preparing the initial version of a standard, to be documented as a NASA Technical Memorandum (TM).

Filtration↗

International Space Station (ISS) Bacterial Filter Elements (BFEs): Filter Efficiency and Pressure Drop Testing of Returned Units

The air quality control equipment aboard the International Space Station (ISS) and future deep space exploration vehicles provide the vital function of maintaining a clean cabin environment for the crew and the hardware. This becomes a serious challenge in pressurized space compartments since no outside air ventilation is possible, and a larger particulate load is imposed on the filtration system due to lack of sedimentation. The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Air (HEPA) filters deployed at multiple locations in each U.S. Seg-ment module; these filters are referred to as Bacterial Filter Elements, or BFEs. In our previous work, we presented results of efficiency and pressure drop measurements for a sample set of two returned BFEs with a service life of 2.5 years. In this follow-on work, we present similar efficiency, pressure drop, and leak tests results for a larger sample set of six returned BFEs. The results of this work can aid the ISS Program in managing BFE logistics inventory through the stations planned lifetime as well as provide insight for managing filter element logistics for future exploration missions. These results also can provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.

ISS Air Quality↗

Filter Efficiency and Leak Testing of Returned ISS Bacterial Filter Elements After 2.5 Years of Continuous Operation

The atmosphere revitalization equipment aboard the International Space Station (ISS) and future deep space exploration vehicles provides the vital functions of maintaining a habitable environment for the crew as well as protecting the hardware from fouling by suspended particulate matter. Providing these functions are challenging in pressurized spacecraft cabins because no outside air ventilation is possible and a larger particulate load is imposed on the filtration system due to lack of sedimentation in reduced gravity conditions. The ISS Environmental Control and Life Support (ECLS) system architecture in the U.S. Segment uses a distributed particulate filtration approach consisting of traditional High-Efficiency Particulate Adsorption (HEPA) filters deployed at multiple locations in each module. These filters are referred to as Bacteria Filter Elements (BFEs). As more experience has been gained with ISS operations, the BFE service life, which was initially one year, has been extended to two to five years, dependent on the location in the U.S. Segment. In previous work we developed a test facility and test protocol for leak testing the ISS BFEs. For this work, we present results of leak testing a sample set of returned BFEs with a service life of 2.5 years, along with particulate removal efficiency and pressure drop measurements. The results can potentially be utilized by the ISS Program to ascertain whether the present replacement interval can be maintained or extended to balance the on-ground filter inventory with extension of the lifetime of ISS to 2024. These results can also provide meaningful guidance for particulate filter designs under consideration for future deep space exploration missions.

ISS Air Quality↗

Tradeoffs among indoor air quality, financial costs, and CO 2 emissions for HVAC operation strategies to mitigate indoor virus in U.S. office buildings

Adapting building operation during the COVID-19 pandemic to improve indoor air quality (IAQ) while ensuring sustainable solutions in terms of costs and CO 2 emissions is challenging and limited in literature. Our previous study investigated different HVAC operation strategies, including increased filtration using MERV 10, MERV 13, or HEPA filters, as well as supplying 100% outdoor air into buildings for a system initially sized for MERV 10 filtration. This paper significantly extends that research by systematically analyzing the potential financial and environmental impact for different locations in the U.S. The previous medium office building system model is improved to account for operation in different climates. New evaluation metrics are created to consider the comprehensive impact of improving IAQ on costs and CO 2 emissions, using dynamic emission factors for electricity generation depending on the location. HVAC operation strategies are studied in five different locations across the United States, with distinct climates and electricity sources. In four of the five locations, MERV 13 filtration offers the best improvement in IAQ per increase in costs and emissions relative to MERV 10. The exception is the mildest climate of San Diego, where use of 100% outdoor air provides the best IAQ with a limited increase in costs and emissions. Finally, a system not sized for HEPA filtration can lead to increased costs and emissions without much improvement in IAQ.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Acute wood smoke exposure is associated with cell-specific hippocampal transcriptomic responses in an accelerated ovarian failure mouse model

Background Wildfire events are increasing in frequency and intensity, and aging individuals demonstrate heightened biological susceptibility to air pollution exposures including increased risk of neurological sequelae. Declining ovarian hormones levels that occur with aging in females along with associated systemic physiological and inflammatory changes may contribute to increased cerebral vulnerability to air pollution, representing a potential but underexplored mechanism. Menopause and the menopausal transition represent a period of profound physiological change that affects cardiovascular, neurological, and immune health. Methods We tested whether peri-menopausal–like hormonal status amplifies hippocampal responses to acute wood smoke (WS) using an ovary-intact, 4-vinylcyclohexene diepoxide (VCD) model of moderate accelerated ovarian failure (AOF) in female C57BL/6 mice. Animals were exposed to HEPA-filtered air (FA) or WS for 4 h/day over 2 consecutive days (∼0.5 mg/m³). Exposure characterization confirmed a complex mixture of combustion products with significant levels of both trace metals and gas release during WS exposure. Results Spatial transcriptomics (10x Visium; n = 4 sections/group) with automated cell-type annotation identified astrocytes, GABAergic and glutamatergic neurons, oligodendrocytes, revealed cell type-specific transcriptional alterations following WS exposure. Distinct transcriptional patterns were observed across all identified neuronal and glial cell populations. Conclusion Together, these findings define a cell-type specific transcriptomic framework describing how WS exposure and ovarian hormone decline interact to influence hippocampal responses and identify potential cellular pathways relevant to hippocampal vulnerability.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Systemic immunological responses are dependent on sex and ovarian hormone presence following acute inhaled woodsmoke exposure

Background: Rural regions of the western United States have experienced a noticeable surge in both the frequency and severity of acute wildfire events, which brings significant challenges to both public safety and environmental conservation efforts, with impacts felt globally. Identifying factors contributing to immune dysfunction, including endocrinological phenotypes, is essential to understanding how hormones may influence toxicological susceptibility. Methods: This exploratory study utilized male and female C57BL/6 mice as in vivo models to investigate distinct responses to acute woodsmoke (WS) exposure with a focus on sex-based differences. In a second set of investigations, two groups were established within the female mouse cohort. In one group, mice experienced ovariectomy (OVX) to simulate an ovarian hormone-deficient state similar to surgical menopause, while the other group received Sham surgery as controls, to investigate the mechanistic role of ovarian hormone presence in driving immune dysregulation following acute WS exposure. Each experimental cohort followed a consecutive 2-day protocol with daily 4-h exposure intervals under two conditions: control HEPA-filtered air (FA) and acute WS to simulate an acute wildfire episode. Results: Metals analysis of WS particulate matter (PM) revealed significantly increased levels of 63 Cu, 182 W, 208 Pb, and 238 U, compared to filtered air (FA) controls, providing insights into the specific metal components most impacted by the changing dynamics of wildfire occurrences in the region. Male and female mice exhibited diverse patterns in lung mRNA cytokine expression following WS exposure, with males showing downregulation and females displaying upregulation, notably for IL-1β, TNF-α, CXCL-1, CCL-5, TGF-β, and IL-6. After acute WS exposure, there were notable differences in the responses of macrophages, neutrophils, and bronchoalveolar lavage (BAL) cytokines IL-10, IL-6, IL-1β, and TNF-α. Significant diverse alterations were observed in BAL cytokines, specifically IL-1β, IL-10, IL-6, and TNF-α, as well as in the populations of immune cells, such as macrophages and polymorphonuclear leukocytes, in both Sham and OVX mice, following acute WS exposure. These findings elucidated the profound influence of hormonal changes on inflammatory outcomes, delineating substantial sex-related differences in immune activation and revealing altered immune responses in OVX mice due to ovarian hormone deficiency. In addition, the flow cytometry analysis highlighted the complex interaction between OVX surgery, acute WS exposure, and their collective impact on immune cell populations within the hematopoietic bone marrow niche. Conclusions: In summary, both male and female mice, alongside females subjected to OVX and those who had sham surgery, exhibit significant variations in the expression of proinflammatory cytokines, chemokines, lung mRNA gene expression, and related functional networks linked to signaling pathways. These differences potentially act as mediators of sex-specific and hormonal influences in the systemic inflammatory response to acute WS exposure during a wildfire event. Understanding the regulatory roles of genes expressed differentially under environmental stressors holds considerable implications, aiding in identifying sex-specific therapeutic targets for addressing acute lung inflammation and injury.

59 BASIC BIOLOGICAL SCIENCES↗

Tank Side Cesium Removal IXC-150 Cask Detonation Report

A set of experiments were conducted at Los Alamos National Laboratory’s firing point 88 to determine the blast pressure and effects of a stoichiometric gas mixture of Hydrogen (H 2 ) and Nitrous Oxide (N 2 O) on the IXC-150 Storage Pad Vent Stack assemblies. The Lab was asked to design, build, and test the vent stack assemblies using a reaction gas volume of 340 in 3 that mimics the Tank Side Cesium Removal (TSCR) Ion Exchange Column (IXC) assembly. The experimental system with vent stack assembly was designed with input from the Washington River Protection Services (WRPS) to ensure an accurate test setup. The tests were conducted at LANL on the newly built filter/gas assembly at the end of April 2021 timeframe, using WRPS supplied vent stack assemblies and internal HEPA filters. The objective of these tests was to observe that the structural integrity of the vent stack assemblies was maintained and determine the resulting blast overpressures at a distance of 16 and 32 inches from the assembly. All work was performed under the LANL Quality Assurance Program (SD330), using a graded application of ASME NQA-1- 2008/NQA-1a-2009. To ensure that all client quality assurance (QA) expectations were addressed, evaluation of the end data needs was performed and the appropriate controls applied for this work.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Review of Experimental Decontamination Factors (DF) of Iodine in the Pilot-Scale Law Melter Off-Gas Systems

The Low Activity Waste (LAW) melters at the Hanford Tank Waste Treatment and Immobilization Plant (WTP) will convert low-activity tank wastes containing high concentrations of sodium salts into glass for onsite disposal. Much of the airborne particulates during the calcination/fusion of the feed solids will be removed by condensation and scrubbing of the melter exhaust in the Submerged Bed Scrubber (SBS) and Wet Electrostatic Precipitator (WESP)of the primary off-gas treatment system. The gases exiting the WESP enter a secondary off-gas treatment system, which includes a High-Efficiency Particulate Air (HEPA) filter, an activated carbon absorber, a Thermal Catalytic Oxidizer (TCO), a Selective Catalytic Reduction (SCR) unit, a caustic scrubber, and an exhauster. Much of the volatile organics and NOx will be removed in the TCO and SCR, respectively. Under WTP Direct Feed LAW (DFLAW) configuration, the liquid effluents from the SBS and WESP will be collected and evaporated under vacuum with the evaporator concentrate recycled back to the LAW melter, while the evaporator condensate will be merged with the caustic scrubber solution and sent to the Effluent Treatment Facility (ETF).

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗