Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Grid Stress”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

IM3 Projected US Data Center Locations

IM3 Projected US Data Center Locations This dataset contains model projections of new data center facilities in the contiguous United States (CONUS) through 2035 using the CERF – Data Centers model. Data center locations are modeled across four data center electricity demand growth scenarios (low, moderate, high, higher) and five market gravity scenarios (0%, 25%, 50%, 75%, 100%). Projected locations are intended to be regional representations of feasible siting locations in the future to assess potential grid and water stress impacts. The data center load growth scenarios correspond with the rates outlined in EPRI (2024) and include 3.71%, 5%, 10%, and 15% annual growth of electricity demand for data centers from 2023 values in 37 states across the CONUS. Market gravity scenarios correspond to the relative importance of proximity to data center markets or high population areas compared to locational cost in the siting algorithm. 0% market gravity means that siting decisions were entirely determined by the locational cost in each feasible location. 100% market gravity means that only market proximity was considered when siting. Other scenarios have weight placed on both components where total weight always equals 100%. Locational cost is dependent on facility cooling type and corresponding electricity cost, taxes, and other factors. Facility cooling type is spatially determined where high water stress and/or areas with high summer wet bulb temperatures are assumed to operate with mechanical cooling for a higher fraction of the year rather than evaporative cooling. Feasible data center siting areas are based on geospatial suitability raster data developed with open-source information. The following areas are excluded from siting: Areas within 300 m of a federal airport runway or within an airport area boundary Waterbodies Areas with slope >16% Areas susceptible to sinkholes High coastal or inland flood risk areas Local, state, and federal parks, leisure areas, and cemeteries Areas >2 km away from electric substations Areas >5 km away from a municipal water supplier service area Areas >2 km away from high-speed fiber provider service territory USGS Protected Areas Database of the United States (PAD-US) GAP status 1, 2, or 3 areas US National Parks Wetlands USFWS critical habitats BIA land areas Railroads, major roadways, and minor roadways Military areas and training grounds NLCD developed lands Areas >0.8 km (0.5 miles) from NLCD developed lands Because we use open-source information, proprietary information that can influence siting decisions such as individual tax agreements with cities, detailed fiber line connectivity, electric grid power capacity agreements, and others, are not currently accounted for in the modeling process. Using specific building locations and footprints in the dataset for local planning purposes is not advised. Technical Information Geospatial data is provided in geojson format using the Albers Equal Area Conic (ESRI:102003) coordinate reference system. The datasets contain the following parameters: id - unique identification number within given scenario file growth_scenario – data center demand growth scenario market_gravity_weight – market gravity weight scenario (%) region – name of region (i.e., US State) total_cost_million_usd – locational siting cost ($million) campus_size_square_ft – total land acquired for data center facility (square ft) data_center_it_power_mw – IT power of data center facility (MW) mechanical_cooling_frac – fraction of year when data center uses mechanical cooling system water_cooling_frac– fraction of year when data center uses evaporative cooling system cooling_energy_demand_mwh – total annual facility energy demand for cooling (MWh) cooling_water_demand_mgy – total annual facility water demand for cooling (MG) cooling_water_consumption_mgy – total annual facility water consumed (MG) normalized_locational_cost – normalized total locational cost score for location normalized_gravity_score – normalized market gravity score for location weighted_siting_score – total weighted siting score of locational cost and gravity score geometry – polygon geometry of facility Acknowledgment IM3 is a multi-institutional effort led by Pacific Northwest National Laboratory and supported by the U.S. Department of Energy's Office of Science as part of research in MultiSector Dynamics, Earth and Environmental Systems Modeling Program. License This data is made available under a CCBY4.0 License Disclaimer This material was prepared as an account of work sponsored by an agency of the United States Government. Neither the United States Government nor the United States Department of Energy, nor the Contractor, nor any or their employees, nor any jurisdiction or organization that has cooperated in the development of these materials, makes any warranty, express or implied, or assumes any legal liability or responsibility for the accuracy, completeness, or usefulness or any information, apparatus, product, software, or process disclosed, or represents that its use would not infringe privately owned rights. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise does not necessarily constitute or imply its endorsement, recommendation, or favoring by the United States Government or any agency thereof, or Battelle Memorial Institute. The views and opinions of authors expressed herein do not necessarily state or reflect those of the United States Government or any agency thereof. PACIFIC NORTHWEST NATIONAL LABORATORYoperated byBATTELLEfor theUNITED STATES DEPARTMENT OF ENERGYunder Contract DE-AC05-76RL01830

Mongird, Kendall (ORCID:0000000328077088)

Ultra‐Flexible Pixelated Perovskite Photodetectors Enabled by Honeycomb Polymer Grids for High‐Resolution Imaging

Abstract A nature‐inspired fabrication method based on a photolithography‐free flexible polymer grid is reported for high‐resolution pixelation of perovskite photodiode arrays with exceptional mechanical ductility and a morphology resembling that of natural compound eyes. The resulting pixelated perovskite photosensitive layer has a ≈1 µm pixel size with 2000 Pixels per inch (PPI) resolution when fully assembled as a photodetector array, delivering a detectivity of >10 13 Jones while providing cross‐talk free imaging. Using a polymer grid effectively releases stress on the perovskite platform, greatly increasing the mechanical agility of the otherwise brittle perovskite film. This novel fabrication methodology and device design offer new possibilities for applications in robotics, biomedical imaging, and virtual and augmented reality.

Zheng, Ding [Department of Chemistry and the Mater

Simulation & Analysis of the Hydronic Shell Retrofit System as a Solution for Deep Energy Retrofits and Electrification of Large Multifamily Housing Communities in Cold Climate

According to the 2020 residential energy consumption survey, there are 32 million multi-family buildings in the United States, and approximately 42% of these have poor or no insulation (US EIA 2020). Electrification of buildings with heat pump is one of the key strategies to achieve the goal of 90% reduction of greenhouse gas emissions in buildings by 2050 (U.S. Department of Energy 2024a). Building electrification will also enable greater penetration of variable renewable energy sources. However, replacing the natural gas dominated heating system by electrical appliance will increase the electrical load in heating dominated climate. It is crucial to well-insulate the building envelope to mitigate the stress in the grid from electrification. The hydronic shell (HS) system discussed next can achieve dual objective of envelope retrofit with space heating system electrification.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI

Thermal Resilience of Residential Building with Thermally Anisotropic Building Envelope Connected to Geothermal Sources

Heat waves and cold snaps have become more frequent and more intense because of climate change. A heat wave and a cold snap are a period of excessively hot and cold weather, respectively, that poses severe risks to building occupants’ health, especially for vulnerable people. They increase electrical energy consumption and put high stress on the grid which leads to potential power outages. Therefore, it is critical to assess and actively improve the thermal resilience of buildings to cope with heat waves, cold snaps, and power outages. The thermally anisotropic building envelope (TABE) is a novel active building envelope that can save energy while maintaining thermal comfort in buildings by redirecting heat and coolness from building envelopes to hydronic loops. When connecting to a ground thermal loop (GL), TABE can utilize the relatively stable temperature of the ground to protect the indoor environment during heat waves and cold snaps. This study assesses the thermal resilience of residential buildings that installed TABE and used ground thermal energy to supply the hydronic loops, abbreviated as ground thermal loop or TABE+GL. The simulation and analysis are conducted for the US Department of Energy prototype single-family detached residential building in the hot climate of Miami, Florida and Tucson, Arizona, and the cold climate of Denver, Colorado, and Rochester, Minnesota. Heat waves and cold snaps were obtained from the historical weather data of 1998-2020 for the studied regions. Three thermal resilience metrics, including the standard effective temperature (SET) degree-hours, the Heat Index, and the Hours of Safety (HOS) were used to quantify the effect of TABE+GL. The results showed that buildings installed TABE+GL could significantly reduce the average SET degree-hours above 30°C, increase HOS, and greatly improve thermal resilience.

Shen, Zhenglai

Structural Analysis of Pyrolytic Graphite Optics for the HiPEP Ion Thruster

The long lifetime requirements of interplanetary exploration missions is driving the need to develop long-life components for the electric propulsion thrusters that are being targeted for these missions. One of the primary life-limiting components of ion thrusters are the optics, which are continuously eroded during the operation of the thruster. Pyrolytic graphite optics are being considered for the High Power Electric Propulsion (HiPEP) ion thruster because of their very high resistance to erosion. This paper describes the structural analysis of the HiPEP pyrolytic graphite. A description of the development of the grid model, as well as the development of the effective properties and stress concentrations in the apertured area of the grids is included. An evaluation of the use of curved grids shows that the increased stiffness (compared to flat grids) prevents intergrid impact during launch, however, the residual stresses introduced by curving the grids pushes the resulting peak stresses beyond the critical stress. As a result, flat grids are recommended as the design solution. Thermally induced grid displacements during normal thruster operation are also presented.

Meckel, Nicole

Identification of pressure points in modern power systems using transfer entropy

Power shortages disrupt daily life, economic activity, and essential services. In modern power systems, weather is an increasingly important driver of reliability: high temperatures raise demand and limit transmission capacity, and calm or cloudy periods reduce wind and solar supply. Using a data-driven analysis, this study identifies grid infrastructure whose operating patterns help predict power shortages. The results show that reliability risks often emerge from interacting stresses across generation, transmission, and demand, rather than from single bottlenecks. By clarifying how system stress propagates through the grid, this diagnostic perspective helps explain why shortages occur under specific conditions and can complement traditional planning and operational tools to support adaptive reliability strategies, targeted monitoring, and coordinated infrastructure investments.

power systems

Development of an Electrostatically Clean Solar Array Panel

The results of design, analysis, and qualification of an Electrostatically Clean Solar Array (ECSA) panel are described. The objective of the ECSA design is to provide an electrostatic environment that does not interfere with sensitive instruments on scientific spacecraft. The ECSA design uses large, ITO-coated coverglasses that cover multiple solar cells, an aperture grid that covers the intercell areas, stress-relieved interconnects for connecting the aperture grid to the coverglasses, and edge clips to provides an electromagnetically shielded enclosure for the solar array active circuitry. Qualification coupons were fabricated and tested for photovoltaic response, conductivity, and survivability to launch acoustic and thermal cycling environments simulating LEO and GEO missions. The benefits of reducing solar panel interaction with the space environment are also discussed.

Stern, Theodore G.

Benchmarking Memory Performance with the Data Cube Operator

Data movement across a computer memory hierarchy and across computational grids is known to be a limiting factor for applications processing large data sets. We use the Data Cube Operator on an Arithmetic Data Set, called ADC, to benchmark capabilities of computers and of computational grids to handle large distributed data sets. We present a prototype implementation of a parallel algorithm for computation of the operatol: The algorithm follows a known approach for computing views from the smallest parent. The ADC stresses all levels of grid memory and storage by producing some of 2d views of an Arithmetic Data Set of d-tuples described by a small number of integers. We control data intensity of the ADC by selecting the tuple parameters, the sizes of the views, and the number of realized views. Benchmarking results of memory performance of a number of computer architectures and of a small computational grid are presented.

Frumkin, Michael A.

Analytical and experimental study of a standing torus with normal loads

Finite element analysis is applied to study the large deflection and stress of a thin-walled pressurized torus loaded by normal contact with a plane. Experimentally determined stresses are compared to those resulting from finite element analysis at various meridional and circumferential coordinates of the torus, including the footprint area. Circumferential strains compare favorably while meridional strains are higher in the finite element analysis, probably due to slippage of the boundary at the rim. The STAGS finite element computer program was used. The purpose of the study was to evaluate the various program options for structural loading, for material modeling, for stress analysis, and for grid refinement. The experimental model, a thin-walled rubber tube mounted on a steel cylindrical rim, provided measured results to compare with various analytical trade-offs. It was found that there was almost no difference in predicted deflections or stress distributions between linear and nonlinear material description. However, the difference between linear analysis and that of geometric nonlinearities utilizing incremental loading was marked.

Mack, M. J., Jr.

Continuum models for static and dynamic analysis of repetitive lattices

A simple, rational approach is presented for developing continuum models for large repetitive lattice structures subjected to static and dynamic loadings. The procedure involves introducing kinematic assumptions to reduce the dimensionality of the lattice, and equating the strain and kinetic energies of the continuum model to those of the original lattice structure. The proposed procedure is applied to obtain effective elastic and dynamic characteristics of continuum plate models for double-layered grids. Numerical results are presented of stress and free vibration problems for two double-layered grids. These problems demonstrate the high accuracy of the continuum plate models developed. Also, an assessment is made of different approximations to these models.

Noor, A. K.

Geothermal-integrated thermally anisotropic building envelope for energy and peak-demand reduction

Buildings consume large amounts of energy for heating and cooling, while peak electricity demand places significant stress on the power grid. This paper presents a reduced-order co-simulation framework and load-oriented supervisory control strategy for a geothermal-integrated thermally anisotropic building envelope with a ground loop (TABE+GL). In TABE+GL, a hydronic loop embedded in the building envelope is directly coupled with a geothermal ground loop, allowing for bidirectional heat exchange between the envelope, the ground, and the indoor environment. A hybrid co-simulation framework was established by coupling a reduced-order resistor–capacitor (RC) thermal network model with EnergyPlus augmented with GHEDesigner modules. The RC model generated feasible heat flux options under three operating modes, and EnergyPlus predicted sensible loads, energy use, and pump energy demand. At each simulation step, a supervisory control algorithm selected the optimal loop configuration and duty factor that maximizes useful TABE geothermal utilization without exceeding the predicted sensible load, thereby avoiding overheating or cooling. Case studies were conducted for Los Angeles, California, Charleston, South Carolina, and Denver, Colorado. Results showed that the proposed framework reduced HVAC electricity consumption by 43%–67%, natural gas use for space heating by 11%–38%, and peak electricity demand by 43%–88%. These results highlight the potential of combining reduced-order envelope modeling, direct geothermal coupling, and load-oriented supervisory control to improve whole building energy performance and reduce peak demand across diverse weather conditions.

Howard, Daniel [Southern Adventist University]

Performance evaluation of underground thermal storage integrated dual-source heat pump systems

The increasing demand for electricity stresses the existing electric grids. Buildings consume 73% of all U.S. electricity and are responsible for 30% of U.S. greenhouse gas emissions. Integrating thermal energy storage (TES) in building heating/cooling systems, which consume considerable electricity, can mitigate the challenges to electric grids. Here, this study reports on a novel thermal energy storage device integrated heat pump system to reshape the building electricity demand profile while maintaining thermal comfort. The annual performance of the proposed system has been evaluated through a dynamic system simulation with high fidelity in the Modelica platform. The dynamic model of the novel hybrid component named ‘dual purpose underground thermal battery’ was developed and validated. It was then incorporated into the system model. Given a time-of-use tariff, a rule-based control strategy was designed to shift the electric demand and switch the heat pump source for a typical single-family house in different climate zones of the United States. The system performance of the new TES-integrated dual-source heat pump was compared with that of a conventional air-source heat pump system. The results indicate that the proposed system can reduce the annual HVAC electricity cost by up to 52% while saving 45.2% on electricity consumption. In the Northern areas, the annual peak load of the HVAC system can be reduced by 64.9%. However, this reduction is less in the Southern areas as the system’s higher efficiency in winter dominates the overall energy-saving potential.

25 ENERGY STORAGE

Oil-impregnated densified wood veneer with high electrical insulation enabled by nanosized oil channels

Growing energy demands and renewable integration are stressing the aging power grid infrastructure. Lignocellulosic oil-impregnated paper is widely used in power transformers but suffers from critical limitations, such as low dielectric strength, mechanical strength, and thermal conductivity, causing premature transformer failures. Here, we demonstrate a superior electrically insulating oil-impregnated paper design using the naturally anisotropic structure of densified wood veneer to achieve nanosized channels of oil that efficiently disrupt electrical breakdown pathways. The developed oil-impregnated densified wood (ODW) creates aligned cellulose fibers with 166 ± 87–nanometer oil nanochannels, achieving record dielectric strength of 105 kilovolts per millimeter. The structure also delivers a mechanical strength of up to 384 megapascals and a thermal conductivity of 0.33 watts per meter per kelvin, enabling enhanced longevity upon thermal aging tests. The ODW could replace conventional transformer insulation to enhance power transformer performance and improve lifetime. Moreover, its anisotropic oil-filled nanochannel design offers a general strategy for hybrid dielectrics in medium- and high-voltage applications.

36 MATERIALS SCIENCE

Evaluation of an improved finite-element thermal stress calculation technique

A procedure for generating accurate thermal stresses with coarse finite element grids (Ojalvo's method) is described. The procedure is based on the observation that for linear thermoelastic problems, the thermal stresses may be envisioned as being composed of two contributions; the first due to the strains in the structure which depend on the integral of the temperature distribution over the finite element and the second due to the local variation of the temperature in the element. The first contribution can be accurately predicted with a coarse finite-element mesh. The resulting strain distribution can then be combined via the constitutive relations with detailed temperatures from a separate thermal analysis. The result is accurate thermal stresses from coarse finite element structural models even where the temperature distributions have sharp variations. The range of applicability of the method for various classes of thermostructural problems such as in-plane or bending type problems and the effect of the nature of the temperature distribution and edge constraints are addressed. Ojalvo's method is used in conjunction with the SPAR finite element program. Results are obtained for rods, membranes, a box beam and a stiffened panel.

Camarda, C. J.

Global/local finite element analysis of composite materials

The motivation for performing global/local finite element analysis in composite materials is described. An example of such an analysis of a composite plate with a central circular hole is presented. Deformed finite element grids and interlaminar normal stress distributions are presented to aid understanding of the plate response. Such distribution at the plate edge is shown to be basically unaffected, although transverse displacements of the edge were slightly different from an analysis of a similar plate with no hole.

Griffin, O. Hayden, Jr.

Automation Tools for Finite Element Analysis of Adhesively Bonded Joints

This article presents two new automation creation tools that obtain stresses and strains (Shear and peel) in adhesively bonded joints. For a given adhesively bonded joint Finite Element model, in which the adhesive is characterised using springs, these automation tools read the corresponding input and output files, use the spring forces and deformations to obtain the adhesive stresses and strains, sort the stresses and strains in descending order, and generate plot files for 3D visualisation of the stress and strain fields. Grids (nodes) and elements can be numbered in any order that is convenient for the user. Using the automation tools, trade-off studies, which are needed for design of adhesively bonded joints, can be performed very quickly.

Tahmasebi, Farhad

Challenges and Opportunities for HVAC + Phase Change Material Thermal Energy Storage in Buildings

Phase-change material (PCM) thermal-energy storage (TES) integrated with HVAC and domestic hot water (DHW) can shift a large share of building thermal loads. By flattening and shifting loads, PCM TES reduces peak electricity use, eases stress on local and grid infrastructure, and lowers costs. It can also defer costly upgrades to service panels, distribution, and transmission. Higher energy density relative to chilled or hot water storage makes PCM TES practical for small, space limited, and retrofit projects, while packaged HVAC-integrated systems expand cost-effective load shifting to commercial buildings that previously lacked options. Despite this promise, deployment faces barriers. This paper presents challenges, opportunities, and lessons learned from lab and field integrations of PCM TES with packaged HVAC systems. Key challenges include misalignment between default heat pump controls tuned for direct-to-load operation and TES charge/discharge objectives, PCM properties that diverge from manufacturer claims and evolve with cycling, and high integration and deployment costs with off-the-shelf products. These studies underscore the need for factory built, integrated systems that arrive as prepackaged modules with proven controls, reducing design and installation effort and delivering predictable performance across projects. The paper outlines steps to enable viable and scalable PCM TES HVAC and DHW systems, including 1) validated methods that can be used to characterize PCM properties and TES system performance, 2) supervisory controls that optimize charge/discharge scheduling, and 3) factory integrated packaging that eliminates bespoke field engineering.

Dutton, Spencer

Calculating Soil Wetness, Evapotranspiration and Carbon Cycle Processes Over Large Grid Areas Using a New Scaling Technique

Soil wetness typically shows great spatial variability over the length scales of general circulation model (GCM) grid areas (approx 100 km ), and the functions relating evapotranspiration and photosynthetic rate to local-scale (approx 1 m) soil wetness are highly non-linear. Soil respiration is also highly dependent on very small-scale variations in soil wetness. We therefore expect significant inaccuracies whenever we insert a single grid area-average soil wetness value into a function to calculate any of these rates for the grid area. For the particular case of evapotranspiration., this method - use of a grid-averaged soil wetness value - can also provoke severe oscillations in the evapotranspiration rate and soil wetness under some conditions. A method is presented whereby the probability distribution timction(pdf) for soil wetness within a grid area is represented by binning. and numerical integration of the binned pdf is performed to provide a spatially-integrated wetness stress term for the whole grid area, which then permits calculation of grid area fluxes in a single operation. The method is very accurate when 10 or more bins are used, can deal realistically with spatially variable precipitation, conserves moisture exactly and allows for precise modification of the soil wetness pdf after every time step. The method could also be applied to other ecological problems where small-scale processes must be area-integrated, or upscaled, to estimate fluxes over large areas, for example in treatments of the terrestrial carbon budget or trace gas generation.

Sellers, Piers