Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Grid Load Forecasting”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

52 records · Page 3

Electric Grid Simulator For Human Factor Research

The developed code simulates real-time monitor and control for west area of IEEE 118-bus system. The 24-hour load profile for each bus is derived by scaling the system’s rated load in the PSSE sav file according to the California Independent System Operator’s Day-ahead load forecast for May 1, 2024. This simulator performs several critical functions: (1) Calculating time-series power flow every 4 seconds; (2) Updating and dispatching AGC signals every minute; (3) Conducting N-1 contingency analysis every 5 minutes. Additionally, the simulator can trip lines and subsequently update and dispatch AGC signals, running power flow analysis after each tripping event.

Huang, Jianqiao [Idaho National Laboratory (INL), ↗

Load Matching Potential of Urban Renewables during Extreme Heat in New York City

Integration of renewable resources to meet growing energy demand is becoming a global priority under decarbonization mandates. This study contributes to ongoing efforts on the matter by assessing the feasibility of using offshore wind and rooftop photovoltaic systems to meet electricity demand during a period of thermal stress in New York City—August 2019. A unified modelling framework, based on the Urbanized Weather Research and Forecasting model, is used to simulate climate, renewable resources and energy demand variables. Findings show significant energy load miss-match, ranging from 3 to 5 GW, between the demand and the composite renewable generation outcome. This study provides a transferable framework for evaluating renewable integration in dense urban regions and highlights the need for additional strategies to support grid resilience during extreme heat events, while clarifying the role of local resources in fully managing NYC’s load.

54 ENVIRONMENTAL SCIENCES↗

HP-FLEX MPC v0.1.0

HP-FLEX MPC is control software developed by Lawrence Berkeley National Laboratory with support from the California Energy Commission (CEC) through EPIC-19-301. HP-FLEX aims to provide load flexibility for heat pumps (HPs) in response to dynamic grid signals (including Time-of-Use, Dynamic Pricing, and Critical Peak Pricing) while maintaining thermostat temperatures within user-specified bounds. The software includes a system-identification module, which models the dynamics of the building envelope with thermostat data, and a control module based on a model predictive controller (MPC) to make optimal decisions. HP-FLEX receives forecasts of outdoor air temperature, solar irradiation, and internal gain (if available), as well as trajectories of energy price, temperature lower and upper bounds over a prediction horizon. It then optimizes heating and cooling capacities to minimize energy cost and peak power (with a user-defined weight on peak power) over the prediction horizon, while maintaining room air temperature within the temperature constraints, and outputs the optimal thermostat setpoints.

Kim, Donghun↗

Hybrid Power Plants for Energy Resilience: A Case Study

As renewable energy technologies are increasingly adopted, they pose an opportunity to improve the sustainability and resilience of distributed grids, especially when their design and operation is coordinated as a hybrid power plant. When included in hybrid power plants, distributed wind turbines in particular have the potential to enhance the resilience of distributed grids in areas with good wind resource, due to their ability to provide more consistent generation and ancillary services as compared to photo-voltaic (PV) solar panels. Despite this benefit, U.S. distributed wind adoption is lower than other comparable renewable energy technologies. In this study, we seek to demonstrate how hybrid power plants that include distributed wind turbines can contribute to distribution grid resilience by meeting loads (especially critical loads) more consistently, increasing reserve capacity, and providing value to customers during outages. To demonstrate these contributions, we integrate three separate frameworks and apply them to a case study in a rural electric cooperative in Iowa. Through this case study, we simulate and compare hybrid power plant design and operation during two hazard events: a tornado that causes a 48-hour distribution outage and a winter weather event that causes a 6-hour generation outage. The inclusion of a hybrid power plant that leverages 1) increased battery duration and 2) advanced forecasting and dispatch strategies that reserve capacity leading up to a hazard event best reduce lost loads as well as diesel consumption that would otherwise be used to meet those loads during short- and long-duration hazard events. Depending on the hybrid power plant capacity and operation, we find that the outage mitigation value of a hybrid power plant (measured in value to customers to avoid an outage and avoided lost revenues for the utility) is significant in both hazard events; adding wind, solar, and battery assets to the existing system adds about $50-$100M in avoided lost load and at least $4-$8k in utility value in the tornado hazard event, and $570k-$2.2M in avoided lost load and at least $220-$650 in utility value in the winter hazard scenario. In both the tornado and winter hazard scenarios, optimizing the operation of the hybrid system for resilience can lend similar value as increasing battery duration by 5 MWh for the lower capacity systems considered.

17 WIND ENERGY↗

Adaptive Numerical Algorithms in Space Weather Modeling

Space weather describes the various processes in the Sun-Earth system that present danger to human health and technology. The goal of space weather forecasting is to provide an opportunity to mitigate these negative effects. Physics-based space weather modeling is characterized by disparate temporal and spatial scales as well as by different physics in different domains. A multi-physics system can be modeled by a software framework comprising of several components. Each component corresponds to a physics domain, and each component is represented by one or more numerical models. The publicly available Space Weather Modeling Framework (SWMF) can execute and couple together several components distributed over a parallel machine in a flexible and efficient manner. The framework also allows resolving disparate spatial and temporal scales with independent spatial and temporal discretizations in the various models. Several of the computationally most expensive domains of the framework are modeled by the Block-Adaptive Tree Solar wind Roe Upwind Scheme (BATS-R-US) code that can solve various forms of the magnetohydrodynamics (MHD) equations, including Hall, semi-relativistic, multi-species and multi-fluid MHD, anisotropic pressure, radiative transport and heat conduction. Modeling disparate scales within BATS-R-US is achieved by a block-adaptive mesh both in Cartesian and generalized coordinates. Most recently we have created a new core for BATS-R-US: the Block-Adaptive Tree Library (BATL) that provides a general toolkit for creating, load balancing and message passing in a 1, 2 or 3 dimensional block-adaptive grid. We describe the algorithms of BATL and demonstrate its efficiency and scaling properties for various problems. BATS-R-US uses several time-integration schemes to address multiple time-scales: explicit time stepping with fixed or local time steps, partially steady-state evolution, point-implicit, semi-implicit, explicit/implicit, and fully implicit numerical schemes. Depending on the application, we find that different time stepping methods are optimal. Several of the time integration schemes exploit the block-based granularity of the grid structure. The framework and the adaptive algorithms enable physics based space weather modeling and even forecasting.

Toth, Gabor↗

Unified Modeling Architecture for Load Management in Extreme Heat: The New York City Case

Integration of renewable resources to meet growing energy demand is becoming a global priority under decarbonization mandates. This study contributes to ongoing efforts on this key subject by assessing the feasibility of using coastal-urban renewable energy resources, namely, offshore wind and rooftop photovoltaic systems, to meet electricity demand of New York City during the intense recent heat wave period of June 2025. A unified modeling framework, based on the urbanized weather research and forecasting model, is used to simulate climate, renewable resources, and energy demand variables. Findings show significant energy load mismatch of approximately 1150 GWh over the month, between the demand and the combined renewable generation outcome. Three storage integration scenarios are analyzed to mitigate the deficits, reducing said deficits by a minimum of approximately 9% over the duration of the month. This study provides a transferable modeling framework tool for evaluating renewable integration in dense urban environments that can be used by grid operators to support grid resilience during extreme heat events.

54 ENVIRONMENTAL SCIENCES↗

Forecasting of Storm-Surge Floods Using ADCIRC and Optimized DEMs

Increasing the accuracy of storm-surge flood forecasts is essential for improving preparedness for hurricanes and other severe storms and, in particular, for optimizing evacuation scenarios. An interactive database, developed by WorldWinds, Inc., contains atlases of storm-surge flood levels for the Louisiana/Mississippi gulf coast region. These atlases were developed to improve forecasting of flooding along the coastline and estuaries and in adjacent inland areas. Storm-surge heights depend on a complex interaction of several factors, including: storm size, central minimum pressure, forward speed of motion, bottom topography near the point of landfall, astronomical tides, and, most importantly, maximum wind speed. The information in the atlases was generated in over 100 computational simulations, partly by use of a parallel-processing version of the ADvanced CIRCulation (ADCIRC) model. ADCIRC is a nonlinear computational model of hydrodynamics, developed by the U.S. Army Corps of Engineers and the US Navy, as a family of two- and three-dimensional finite-element-based codes. It affords a capability for simulating tidal circulation and storm-surge propagation over very large computational domains, while simultaneously providing high-resolution output in areas of complex shoreline and bathymetry. The ADCIRC finite-element grid for this project covered the Gulf of Mexico and contiguous basins, extending into the deep Atlantic Ocean with progressively higher resolution approaching the study area. The advantage of using ADCIRC over other storm-surge models, such as SLOSH, is that input conditions can include all or part of wind stress, tides, wave stress, and river discharge, which serve to make the model output more accurate. To keep the computational load manageable, this work was conducted using only the wind stress, calculated by using historical data from Hurricane Camille, as the input condition for the model. Hurricane storm-surge simulations were performed on an eight-node Linux computer cluster. Each node contained dual 2-GHz processors, 2GB of memory, and a 40GB hard drive. The digital elevation model (DEM) for this region was specified using a combination of Navy data (over water), NOAA data (for the coastline), and optimized Interferometric Synthetic Aperture Radar data (over land). This high-resolution topographical data of the Mississippi coastal region provided the ADCIRC model with improved input with which to calculate improved storm-surge forecasts.

Valenti, Elizabeth↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains.Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling.The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

99 GENERAL AND MISCELLANEOUS↗

Optimizing Control for Efficient Load Shifting with Thermal Energy Storage in Existing HVAC Systems

This project developed the integration of a direct-contact heat exchanger (DCHX) based thermal energy storage (TES) system with a chiller–air handling unit (AHU) plant to evaluate its potential for reducing building energy costs. Detailed physical models of the TES unit, building envelope, and HVAC components were developed alongside simplified control-oriented models to support both high-fidelity simulation and real-time optimization. Two control strategies were implemented and compared: a rule-based control (RBC) aligned with utility time-of-use (ToU) rates, and a model predictive control (MPC) framework leveraging forecasts of building load, weather, and internal gains. Simulation results show that the RBC strategy reduced daily electricity costs by around 30% by shifting cooling production from on-peak to off-peak hours. In contrast, the MPC strategy achieved significantly greater performance, reducing daily operating costs by up to 44% and peak-hour costs by more than 60%. Both strategies maintained indoor thermal comfort within acceptable limits, with MPC further improving load distribution and reducing equipment cycling. The outcomes confirm that TES integration, particularly when coordinated with advanced predictive control, can provide substantial cost savings and on-peak demand reduction. . These findings directly support the U.S. Department of Energy’s goals for grid-interactive efficient buildings and demonstrate the potential of TES-enabled HVAC systems for scalable deployment across the commercial building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Calibration of urban building energy model using smart meter data for district peak load prediction

Urban building energy modeling (UBEM) is a powerful approach to assessing baseline building energy performance and retrofits with new technologies across building stocks in cities. However, the accuracy of UBEM is often constrained by the limited availability of reliable data about building characteristics and operations, such as envelope efficiency levels, HVAC system performance, and end-use load patterns. Existing research has performed UBEM calibration using annual or monthly energy consumption data, which falls short when higher-resolution time series applications are needed, such as peak load prediction for utility operation planning. This study presents a new framework for calibrating building energy models at urban scale using smart meter data, targeting the accurate prediction of summer peak electricity loads to support robust grid planning. The framework first integrates various data sources to enhance baseline input assumptions for building models, and then calibrates the baseline models through a pattern-matching approach. A case study using CityBES and two years of AMI data from over 9000 residential customers in Portland, Oregon, demonstrated the workflow and its effectiveness. The calibrated models achieved a daily peak load mean absolute percentage error of 2.6 % during the heatwave in the calibration year, and 2.0 % in the validation year using another year of AMI data. Using the calibrated models, we analyzed the demand flexibility potential of the district building stock as an application of UBEM calibration. The findings affirm the appropriate use of UBEM for peak electric load forecasting and demand side management at the utility distribution system level.

AMI data↗

An Empirical Validation of a Constrained Bin Packing Algorithm for a Home Energy Management System

The increasing number of intelligent electrical appliances and home energy management systems provide a big opportunity for demand response services from residential and small commercial buildings to the grid. Simultaneously, direct control of individual devices by utilities can cause communication bottlenecks, as well as coordination and privacy concerns. These challenges can be addressed by combining the constituent devices into a single house battery equivalent for the purposes of demand response, using Minkowski sum and a 2d bin packing problem. However, the well-studied traditional problems have not been tested in a real house, as implementation carries significant challenges of its own. We deploy the packing problem on residential devices in a controllable house. We report the barriers we found, such as charge forecast and scalability of the algorithm, and discuss our solutions. The study serves as an intermediate step between existing theoretical research and possible future steps, such as prototype deployments of systems that provide residential demand response.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

ASEAN Technical Exchange Workshop for System Operators, Regulators, and Policymakers

This presentation provides an in-depth exploration of power system planning, cross-border electricity trading, and battery energy storage systems (BESS), offering actionable insights for system operators, regulators, and policymakers. The first section delves into power system planning and analysis, focusing on capacity expansion models and resource adequacy studies, including their role in optimizing system efficiency, managing emissions, and addressing system reliability risks. Key considerations, such as integration of transmission into generation planning and the forecasting versus optimization of customer distributed energy resources (DER) technologies, are explored. The session highlights critical trade-offs in spatial granularity and model runtimes, as well as the feasibility of aligning distribution investments with capacity expansion efforts. The second section examines cross-border electricity trading, with an emphasis on resource adequacy concepts such as reliability targets, loss of load expectation (LOLE), and planning reserve margins (PRM). Case studies on reserve market design and coordination across US regions provide insights into improving reserve deliverability and managing interregional power balance and congestion. This section also addresses market-to-market congestion management, including advanced strategies for high-voltage direct current (HVDC) optimization and ancillary service delivery. Finally, the presentation covers the rapid evolution of Battery Energy Storage Systems (BESS), highlighting their operational growth, regulatory frameworks, and use cases in grid flexibility, energy storage, and reliability. The discussion focuses on the benefits of BESS for system stability, resilience, and integration of renewable energy, offering insights into its role as a vital component in the transition toward a more sustainable and flexible grid. Key performance parameters, such as throughput, round-trip efficiency, and state of charge, are also examined.

25 ENERGY STORAGE↗

A Machine Learning Approach for Hourly Traffic Prediction Used in EV-Charging Sites

Reliable forecasting of hourly traffic volumes on highways is critical for planning and operating electric-vehicle charging infrastructure without overloading the grid. In this work, we develop and evaluate a station-specific machine-learning approach based on NeuralProphet, enhanced with conditional seasonality to better distinguish weekday, weekend, and holiday patterns. For each station, the model automatically retrieves the same calendar day from the prior years as an AR-Net initialization, fits trend and Fourier-based seasonality components, and then applies short-term auto-regressive corrections. We train and test on 2021 and 2022 TMAS data, respectively, and validate performance over the whole year. We chose to demonstrate how the model performs on a typical weekday (3/15/2022), weekend (3/27/2022), and a special holiday (12/25/2022). Our results yield MAPE of 7.4%, 23.6%, and 32.0%, respectively. Over the entire year 2022, the overall MAPE was 17%. This demonstrates that station-specific models with conditional seasonality can achieve accurate, scalable hourly forecasts for EV-charging load planning.

99 - GENERAL AND MISCELLANEOUS↗

Advanced co-simulation framework for assessing the interplay between occupant behaviors and demand flexibility in commercial buildings

With buildings contributing significantly to electricity usage, enabling demand flexibility becomes a challenge, especially when accounting for occupant comfort. This study introduces an innovative co-simulation framework integrating multiple models: heating, ventilation, and air conditioning (HVAC) system, building zone load, indoor airflow, supervisory control, and occupant comfort and behavior. Uniquely, this framework allows for a comprehensive and dynamic analysis of building systems and occupant interactions in demand response events. Using this framework, we conducted a case study using a typical small office building model. Specifically, we focused on three areas: (1) the impact of indoor airflow modeling on energy use, occupant comfort, and behaviors forecasting, (2) the impact of occupant behaviors on demand flexibility, and (3) occupant comfort and behaviors under demand response events. Key performance indicators such as energy use, flexibility factor, durations of occupant discomfort and occupant behaviors were analyzed. Our findings indicated variations in energy usage and occupant comfort within demand flexibility events, marked by uncertainty boundaries, with variability in demand shedding up to 57.9%. Here, we concluded that this framework is suitable for analyzing typical commercial buildings and their HVAC systems in terms of demand flexibility potential under the impact of occupant behaviors.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Parallelization of the Physical-Space Statistical Analysis System (PSAS)

Atmospheric data assimilation is a method of combining observations with model forecasts to produce a more accurate description of the atmosphere than the observations or forecast alone can provide. Data assimilation plays an increasingly important role in the study of climate and atmospheric chemistry. The NASA Data Assimilation Office (DAO) has developed the Goddard Earth Observing System Data Assimilation System (GEOS DAS) to create assimilated datasets. The core computational components of the GEOS DAS include the GEOS General Circulation Model (GCM) and the Physical-space Statistical Analysis System (PSAS). The need for timely validation of scientific enhancements to the data assimilation system poses computational demands that are best met by distributed parallel software. PSAS is implemented in Fortran 90 using object-based design principles. The analysis portions of the code solve two equations. The first of these is the "innovation" equation, which is solved on the unstructured observation grid using a preconditioned conjugate gradient (CG) method. The "analysis" equation is a transformation from the observation grid back to a structured grid, and is solved by a direct matrix-vector multiplication. Use of a factored-operator formulation reduces the computational complexity of both the CG solver and the matrix-vector multiplication, rendering the matrix-vector multiplications as a successive product of operators on a vector. Sparsity is introduced to these operators by partitioning the observations using an icosahedral decomposition scheme. PSAS builds a large (approx. 128MB) run-time database of parameters used in the calculation of these operators. Implementing a message passing parallel computing paradigm into an existing yet developing computational system as complex as PSAS is nontrivial. One of the technical challenges is balancing the requirements for computational reproducibility with the need for high performance. The problem of computational reproducibility is well known in the parallel computing community. It is a requirement that the parallel code perform calculations in a fashion that will yield identical results on different configurations of processing elements on the same platform. In some cases this problem can be solved by sacrificing performance. Meeting this requirement and still achieving high performance is very difficult. Topics to be discussed include: current PSAS design and parallelization strategy; reproducibility issues; load balance vs. database memory demands, possible solutions to these problems.

Larson, J. W.↗

Modeling and Analysis of Stirling Power Convertors

Modeling and Analysis of Stirling Power Convertors Luis A. Rodriguez1 Steven M. Geng, Terry V. Reid, Scott D. Wilson NASA Glenn Research Center, Cleveland, OH, 44135, USA NASA Glenn’s Thermal Energy Conversion Branch is supporting the development of the next generation free-piston Stirling power convertors. American Superconductor (AMSC) and Sunpower Inc. are the two firms under contract to develop the Flexure Isotope Stirling Convertor (FISC) and the Sunpower Robust Stirling Convertor (SRSC), respectively. To comprehend and forecast convertor performance, Sage, ANSYS® Maxwell, and ANSYS® Fluent were used to model the Stirling thermodynamic cycle, alternator electromagnetics, and piston and displacer dynamics. I. Introduction Stirling convertors are being developed by NASA as a potential steady source of electrical power for NASA’s future scientific space missions. Currently, NASA Glenn Research Center has two corporations under contract, American Superconductor (AMSC) and Sunpower Inc., for the development of the next generation of free-piston Stirling convertors for dynamic radioisotope power systems. AMSC is developing the Flexure Isotope Stirling Convertor (FISC), which uses flexures to prevent side motion and rubbing of the piston. Similarly, Sunpower Inc, is developing the Sunpower Robust Stirling Convertor (SRSC). The SRSC uses gas bearings to prevent radial contact of the moving piston. As convertor development continues, it is increasingly important to understand and predict the interactions of components in the system, how they respond to one another, and how they perform as a response to changes in operating conditions. A suitable and enlightening way to demonstrate and foresee these interactions is with the use of accurate modeling software. Sage, ANSYS® Maxwell, and ANSYS® Fluent are the current modeling tools used by NASA to analytically determine convertor performance. Sage is a one-dimensional object-oriented commercial software package used for modeling and optimizing Stirling convertors for Dynamic Radioisotope Power Systems (DRPS) and it is one of the most accurate Stirling convertor codes in use by NASA. This code is the successor to GLIMPS (Globally-Implicit Stirling Cycle Simulation) and GLOP (GLIMPS Optimization) software created by Gedeon Associates [1]. Model input parameters are typically material/gas type, component physical dimensions, temperatures, frequency, charge pressure, and number of time/space nodes. Sage is used to model both the FISC’s and SRSC’s Stirling cycle thermodynamics and piston/displacer dynamics. Performance maps were created and analyzed for both power systems to better understand the relationship between the following conditions: cold-end temperature, hot-end temperature, piston/displacer amplitudes, pressure drop, and thermal input power. The synergy between these conditions will help determine parameter sensitivity. ANSYS® Maxwell was used to create a three-dimensional (3-D) axisymmetric model for both FISC and SRSC alternators. The significant physical components included in each model are the magnets, magnet carrier, outer/inner laminations, and the coil. Inputs to the model are piston amplitude, piston frequency, alternator load, coil resistance, tuning capacitance, and specific material properties. The alternator models calculate terminal voltage, current, piston/current phase, voltage/current phase, coil inductance, terminal power and efficiency. The RI2 losses, core (hysteresis and eddy) losses, and magnet/can eddy losses are also a part of the final results. ANSYS® Fluent is used to build 3-D computational fluid dynamic (CFD) models to examine the Stirling cycle thermodynamics for both the FISC and SRSC systems. Three-dimensional Computer Aided Design (CAD) models were used to create the physical components of each convertor. Steady-state simulations were conducted for hardware testing, prediction of environmental losses during testing, and generation of radiation look-up tables. The model inputs to the aforementioned analysis are the material properties and boundary thermal conditions. The steady-state model calculates temperature and heat flow distributions. Transient 3-D calculations were also part of the CFD analysis. In this study a physically reduced version of the FISC is used to obtain a prediction of available engine power. For the gas bearing SRSC, the transient effort is used to obtain a prediction of bearing pad performance and its sensitivity to micro-channel geometric variation. The model inputs to the transient simulations are the piston amplitude, displacer amplitude, frequency, displacer/piston phase angle, dynamic deforming CFD grid, temperature boundary conditions, and user defined files describing motion profile of piston/displacer. The results of the model are temperature distributions, heat distributions, and PV power produced at pre-determined conditions.

Luis A Rodriguez↗