Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Graphite specimens”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Compression behavior of graphite-thermoplastic and graphite-epoxy panels with circular holes or impact damage

An experimental investigation of the compression behavior of laminated specimens made from graphite-epoxy tape, graphite-thermoplastic tape and graphite-thermoplastic fabric was conducted. Specimens with five different stacking sequences were loaded to failure in uniaxial compression. Some of the specimens had central circular holes with diameters up to 65 percent of the specimen width. Other specimens were subjected to low speed impact with impact energies up to 35 J prior to compressive loading. This investigation indicates that graphite-thermoplastic specimens with holes have up to 15 percent lower failure stresses and strains than graphite-epoxy specimens with the same stacking sequence and hole size. However, graphite-thermoplastic specimens subjected to low speed impact have up to 15 percent higher failure stresses and strains than graphite-epoxy specimens with the same stacking sequence and impact energy. Compression tests of graphite-thermoplastic specimens constructed of unidirectional tape and fabric indicate that the material form has little effect on failure strains in specimens with holes or low speed impact damage.

Jegley, Dawn C.↗

Comparison of hand laid-up tape and filament wound composite cylinders and panels with and without impact damage

Experimentally determined axial compressive failure loads, strains and failure modes of composite flat panels and cylinders are presented. A comparison of two types of filament wound flat graphite-epoxy panels indicates that the winding pattern can influence structural response. A comparison of hand laid-up tape and filament wound composite cylinders indicates that fabrication method may not significantly influence the failure mode or average failure strain of thick-walled (radius-to-thickness ratio less than 15) graphite-epoxy cylinders. The interaction of manufacturing-induced features (fiber cross-overs) and low-speed impact damage for graphite-epoxy specimens is also presented. Filament would flat panels with many fiber cross-overs exhibited lower failure strains than filament wound panels without fiber cross-overs for all impact speeds examined. Graphite-thermoplastic cylinders exhibited a significantly different failure mode from the graphite-epoxy cylinders.

Jegley, Dawn C.↗

Numerical analysis of the Iosipescu specimen for composite materials

A finite element analysis of the Iosipescu shear tests for unidirectional and cross-ply composites is presented. It is shown that an iterative analysis procedure must be used to model the fixture-specimen kinematics. The correction factors which are needed to compensate for the nonuniformity of stress distribution in calculating shear modulus are shown to be dependent on the material orthotropic ratio and the finite element loading models. Test section strain distributions representative of typical graphite-epoxy specimens are also presented.

Ho, H.↗

Numerical analysis of the Iosipescu specimen for composite materials

A finite element analysis of the Iosipescu shear tests for unidirectional and cross-ply composites is presented. It is shown that an iterative analysis procedure must be used to model the fixture-specimen kinematics. The correction factors which are needed to compensate for the nonuniformity of stress distribution in calculating shear modulus are shown to be dependent on the material orthotropic ratio and the finite element loading models. Test section strain distributions representative of typical graphite-epoxy specimens are also presented.

Ho, H.↗

Compression behavior of graphite-epoxy and graphite-thermoplastic panels with circular holes or impact damage

An experimental investigation of the compression behavior of laminated specimens made from graphite-epoxy tape (AS4-3502), graphite-thermoplastic tape (AS4-PEEK), and graphite-thermoplastic fabric (AS4-PEEK) was conducted. Specimens with five different stacking sequences were loaded to failure in uniaxial compression. Some of the specimens had central circular holes with diameters up to 65 percent of the specimen width. Other specimens were subjected to low speed impact with impact energy up to 30 J prior to compressive loading. This investigation indicates that graphite-thermoplastic specimens with holes have up to 15 percent lower failure stresses and strains than graphite-epoxy specimens with the same stacking sequence and hole size. However, graphite-thermoplastic specimens subjected to low speed impact have up to 15 percent higher failure stresses and strains than graphite-epoxy specimens with the same stacking sequence and impact energy. Compression tests of graphite-thermoplastic specimens constructed of unidirectional tape and of fabric indicate that the material form has little effect on failure strains in specimens with holes or low speed impact damage.

Jegley, Dawn C.↗

Performance of Graphite Oxidation with Environment and Specimen Geometry

Introduction -Motive for the study (a modest request) •Issues that must be considered -Pertinent oxidation background information •Three oxidation regimes -ASTM D7542 • The primary parameters for oxidation control -Energy of the System -Atmosphere -Reaction Interface

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Comparison of hand laid-up tape and filament wound composite cylinders and panels with and without impact damage

The results of this experimental comparison of filament wound control (unimpacted) cylinders loaded to failure in axial compression indicates that one fiber cross-over location has no effect on the failure mode or strain in thick walled filament wound graphite-epoxy specimens with stacking sequence (plus or minus 45/90) sub 3s. A comparison between filament wound and hand laid-up tape control cylinders indicates that there is little or no difference in the response of cylinders constructed by using two different fabrication methods, however, unimpacted panels with many fiber cross-overs fail at up to 15 percent lower strains than panels with no fiber cross-overs. A comparison of samples subjected to low speed impact damage prior to compressive loading indicates that impact damage reduces the strain at failure by over 60 percent in tape and filament wound graphite-epoxy cylinders and in tape flat panels. The presence of fiber cross-overs was observed to reduce the strength of filament wound impact-damaged panels, but to have no significant effect on the strength of filament wound impact-damaged cylinders.

Jegley, Dawn C.↗

Sectioning of NBG-17 Graphite Billet

The Advanced Reactor Technologies (ART) Baseline Graphite Characterization program at the Idaho National Laboratory (INL) is performing a comprehensive evaluation of inter-billet variations in as-produced nuclear-grade graphite. Before graphite test specimens are machined, the full-size billets must be pre-sectioned into sub-blocks that can be more easily handled and shipped. As manufactured, NBG-17 billets are rectangular in shape, nearly 6 feet in length, and may exceed 1,500 pounds in weight. Sectioning of these billets must be accomplished via a supplier that is capable of handling and cutting the billets into individual slabs and quartering these slabs into sub-blocks. Billets will be pre-labeled by the Purchaser prior to leaving controlled storage such that traceability of any individual sub-block is never lost during sectioning operations.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Materials property changes in ETU-10 graphite due to neutron irradiation at elevated temperatures

Graphite grade ETU-10, from IBIDEN Co., Ltd. Has been irradiated in the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory (ORNL). The irradiation program was developed to provide a preliminary study the irradiation-induced property changes to the dimensions/volume, elastic properties, strength, electrical resistivity, coefficient of thermal expansion, and thermal diffusivity/conductivity over a range of temperatures and neutron exposures that may be relevant for future nuclear reactors. The irradiation envelope covers a range of irradiation temperatures (300°C–900 °C) and fluences (up to 40 × 10 25 n/m 2 [E > 0.1 MeV] or ~30 dpa) that would be relevant for advanced nuclear reactors. Further, the dimensional change was observed to be anisotropic for an isotropic graphite, the specimen dimensions, volume, Young's modulus, shear modulus, and strength all displayed a parabolic fluence dependence, the electrical resistivity had a rapid rise followed by a decrease and a later increase, at high fluence the mean coefficient of thermal expansions was similar for all irradiation temperatures, and thermal conductivity rapidly decreased followed by a continued loss.

36 MATERIALS SCIENCE↗

Wear and friction of oxidation-resistant mechanical carbon graphites at 650 C in air

Studies were conducted to determine the friction and wear properties of experimental carbon-graphites. Hemispherically tipped carbon-graphite rider specimens were tested in sliding contact with rotating Inconel X-750 disks in air. A surface speed of 1.33 m/sec, a load of 500 g, and a specimen temperature of 650 C were used. Results indicate: (1) hardness is not a major factor in determining friction and wear under the conditions of these studies. (2) Friction and wear as low as or lower than those observed for a good commercial seal material were attained with some of the experimental materials studied. (3) The inclusion of boron carbide (as an oxidation inhibitor) has a strong influence on wear rate. (4) Phosphate treatment reduces the friction coefficient when boron carbide is not present in the base material.

Allen, G. P.↗

Preliminary development of a fundamental analysis model for crack growth in a fiber reinforced composite material

A mathematical model for the strength of fiber reinforced composites containing specific flaws is described. The approach is to embed a local heterogeneous region surrounding the crack tip in an anisotropic elastic continuum. By consideration of the individual failure events activated near the flaw tip, a strength prediction can be made from basic properties of the composite constituents. Computations for arbitrary flaw size and orientation have been performed for unidirectional composites with linear elastic-brittle constituent behavior. The mechanical properties were those of graphite epoxy. With the rupture properties arbitrarily varied to test the capability of the model to reflect real fracture modes in fiber composites, it is shown that fiber breakage, matrix crazing, crack bridging, matrix-fiber debonding, and axial splitting all can occur during gradually increasing load prior to catastrophic fracture. Qualitative comparisons with experimental results on edge-notched unidirectional graphite epoxy specimens have also been made.

Kanninen, M. F.↗

Measurement of damping of graphite epoxy materials

The design of an experiment to measure the damping of a cylindrical graphite-epoxy specimen with a three point support and a knife edge support is described as well as equipment used in tests conducted to determine the influence of the support at the two ends of the specimen and to simulate an idealized free-free boundary condition at the two edges. A curve fitting technique is being used to process the frequency response data obtained. Experiments conducted on the thin plate specimen also reveal the influence of the end support condition on the damping ratio of the specimen. The damping ratio values measured for both specimens appear to be strongly influenced by the shape of the specimen and appear to depend on length and fiber orientation as well as the presence of discontinuities such as sharp bends, corners, and notches.

Crocker, M. J.↗

Measurement of damping of graphite expoxy materials

During this period damping measurements were made on the cylindrical graphite epoxy specimen using the forced-vibration test method. The specimen was carefully mounted directly on the shaker through the supporting ring and the impedance head. This was done to simulate an idealized free-free boundary condition at the two edges. The damping ratio value and the natural frequency (first mode) obtained in this experiment were 0.13% and 508.75 Hz respectively. In order to check the damping induced by the supporting ring, measurements were made with the top half of the ring removed. The specimen then was supported only by the bottom half of the ring (half ring). It was observed that the natural frequency of the specimen (first mode) increased of a value of 552.5 Hz due to the influence of the reduced mass of the supporting ring. But the damping ratio value obtained was the same as that obtained with full supporting ring, namely 0.13%.

Crocker, M. J.↗

Holographic interferometry - Errors caused by thermal gradients in holographic plates

Thermal effects as sources of errors in holographic interferometry are illustrated on an example of reflection holography patterns obtained on graphite-epoxy specimens exposed before and after compressive loading. The numerical interpretation of the obtained holograms indicated some peculiar unexpected thickness changes in the specimen. In addition, some patterns showed random occurrence of zones of low and zero contrast. These discrepancies occurred usually in the first of the two exposures and were traced to thermal warping and thermal relaxation patterns caused by small temperature gradients that resulted from heat transfer to the photographic plates during their installation. Suggested precautions to minimize thermal effects include using thick holographic plates (photographic plates attached to glass plates) and insulated gloves during handling and allowing time to establish thermal equilibrium before the exposure.

Post, D.↗

Damage-induced property changes in composites subjected to cyclic thermal loading

Damage in the form of transverse cracks resulting from thermal loading is studied as it relates to the dimensional stability of flat laminates and stiffness changes in cylindrical tubes. Graphite-epoxy specimens were subjected to cyclic thermal loading in the temperature range -250 to + 250 F. It is shown that transverse cracking is the dominant damage mechanism in both types of structural elements. Fiber splitting is also quite common at the low test temperatures. Experimental results indicate that damage significantly reduces the inplane coefficients of thermal expansion of flat laminates and the torsional stiffness of the tubes. Theoretical predictions for coefficients of thermal expansion as a function of crack spacing in flat laminates followed the same trend as experimental results.

Herakovich, Carl T.↗

Effects of matrix toughness on fatigue response of graphite fiber composite laminates

The effect of the matrix toughness on the fatigue response of graphite-fiber-composite laminates was investigated by comparing the fatigue-response results, obtained using the test method of Bakis et al. (1989), for two graphite-epoxy specimens subjected to constant-amplitude fully-reversed loading, namely, (0/ +45/90/ -45)s4 AS4/PEEK samples with drilled center holes and T300-5208 samples. It was found that, although similar matrix damage modes were observed in the two materials, several significant differences occurred in the S-N data and in stiffness data taken over the lives of the two materials, especially at high cyclic stresses.

Simonds, Robert A.↗

Strain energy release rate distributions for double cantilever beam specimens

A 24-ply composite double cantilever-beam specimen under mode I (opening) loading has been analyzed by a 3D FEM code that calculated along a straight delamination starter for several different specimen materials. An isotropic specimen was found to have a strain-energy release rate distribution which varied along its delamination front due to the boundary-layer effect and another effect associated with the anticlastic curvature of the bent specimen arms. A 0-deg graphite-reinforced epoxy specimen had a nearly-uniform strain-energy release rate distribution which dropped only near the edge, due to the boundary-layer effect, and a +/- 45-deg graphite/epoxy specimen exhibited a pronounced strain-energy release rate variation across the specimen width.

Crews, J. H., Jr.↗

New acousto-ultrasonic techniques applied to aerospace materials

The use of an NdYAG pulsed laser for generating ultrasonic waves for NDE in resin matrix composites was investigated. A study was conducted of the use of the 1.064 micron wavelength NdYAG pulsed laser with the neat, unreinforced resin as well as graphite fiber/polymer composite specimens. In the case of the neat resins it was found that, at normal incidence, about 25 percent of the laser pulse energy was reflected at the incident surface. An attenuation coefficient for the polyimide resin, PMR-15 was determined to be approximately 5.8 np/cm. It was found in energy balance studies that graphite fiber/polymer specimens attenuate the laser beam more than do neat resins. The increase absorption is in the graphite fibers. The occurrence of laser induced surface damage was also studied. For the polymer neat resin, damage appears as pit formation over a small fraction of the pulse impact area and discoloration over a larger part of the area. A damage threshold was inferred from observed damage as a function of pulse energy. The 600 F cured PMR-15 and PMR-11 exhibit about the same amount of damage for a given laser pulse energy. The damage threshold is between 0.06 and 0.07 J/sq cm.

Kautz, Harold E.↗