Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GOLD IONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Human erythrocytes and neuroblastoma cells are affected in vitro by Au(III) ions

Gold compounds are well known for their neurological and nephrotoxic implications. However, haematological toxicity is one of the most serious toxic and less studied effects. The lack of information on these aspects of Au(III) prompted us to study the structural effects induced on cell membranes, particularly that of human erythrocytes. AuCl{sub 3} was incubated with intact erythrocytes, isolated unsealed human erythrocyte membranes (IUM) and molecular models of the erythrocyte membrane. The latter consisted of multibilayers of dimyristoylphosphatidylcholine and dimyristoylphosphatidylethanolamine, phospholipids classes located in the outer and inner monolayers of the human erythrocyte membrane, respectively. This report presents evidence that Au(III) interacts with red cell membranes as follows: (a) in scanning electron microscopy studies on human erythrocytes it was observed that Au(III) induced shape changes at a concentration as low as 0.01 {mu}M; (b) in isolated unsealed human erythrocyte membranes Au(III) induced a decrease in the molecular dynamics and/or water content at the glycerol backbone level of the lipid bilayer polar groups in a 5-50 {mu}M concentration range, and (c) X-ray diffraction studies showed that Au(III) in the 10 {mu}m-1 mM range induced increasing structural perturbation only to dimyristoylphosphatidylcholine bilayers. Additional experiments were performed in human neuroblastoma cells SH-SY5Y. A statistically significant decrease of cell viability was observed with Au(III) ranging from 0.1 {mu}M to 100 {mu}M.

60 APPLIED LIFE SCIENCES↗

Change in magnetic and structural properties of FeRh thin films by gold cluster ion beam irradiation with the energy of 1.67 MeV/atom

The effect of energetic cluster ion beam irradiation on magnetic and structural properties of FeRh thin films have been investigated. The cluster ions used in the present studies consist of a few gold atoms with the energy of 1.67 MeV/gold atom. Saturation magnetization of the sample irradiated with Au3 cluster ion beam (280 emu/cc) is larger than that for the irradiated sample with Au1 ion beam (240 emu/cc) for the same irradiation ion fluence. These results can also be confirmed by the X-ray magnetic circular dichroism (XMCD) measurement; the XMCD signal for Au3 cluster ion irradiation is larger than that for Au1 ion irradiation. Since the ion beam irradiation induced magnetization of FeRh is significantly correlated with the amount of the lattice defects in the samples, cluster ion beam irradiation can be considered to effectively introduce the lattice defects in B2-type FeRh rather than the single ion beam. Consequently, cluster ion irradiation is better than single ion irradiation for the viewpoint of saturation magnetization, even if the same irradiation energy is deposited in the samples.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reverse Self-Assembly: (111)-Oriented Gold Crystallization at Alkylthiol Monolayer Templates

It has long been known that thiol-terminated molecules self-assemble as commensurate monolayers on Au(111) surfaces. By spreading floating octadecanethiol monolayers on aqueous solutions of chloroauric acid (HAuCl{sub 4}) and using x rays to reduce the gold ions as well as to probe the structure, we have observed the nucleation of (111)-oriented Au nanoparticles at thiol surfaces. This process may be similar to the formation of biogenic gold by bacteria. The thiol monolayer acts as a 'soft template,' changing its structure as Au crystals form so that there is a {radical}3 x {radical}3 commensurate relationship.

74 ATOMIC AND MOLECULAR PHYSICS↗

Spectroscopic study of gold nanoparticle formation through high intensity laser irradiation of solution

A spectroscopic study of the gold nanoparticle (NP) formation by high-intensity femtosecond laser irradiation of a gold ion solution was reported. The effect of varying energy density of the laser on the formation of gold NPs was also investigated. The surface plasmon resonance (SPR) peak of the gold nanocolloid in real-time UV-visible absorption spectra during laser irradiation showed a distinctive progress; the SPR absorption peak intensity increased after a certain irradiation time, reached a maximum and then gradually decreased. During this absorption variation, at the same time, the peak wavelength changed from 530 to 507 nm. According to an empirical equation derived from a large volume of experimental data, the estimated mean size of the gold NPs varied from 43.4 to 3.2 nm during the laser irradiation. The mean size of gold NPs formed at specific irradiation times by transmission electron microscopy showed the similar trend as that obtained in the spectroscopic analysis. From these observations, the formation mechanism of gold NPs during laser irradiation was considered to have two steps. The first is a reduction of gold ions by reactive species produced through a non-linear reaction during high intensity laser irradiation of the solution; the second is the laser fragmentation of produced gold particles into smaller pieces. The gold nanocolloid produced after the fragmentation by excess irradiation showed high stability for at least a week without the addition of any dispersant because of the negative charge on the surface of the nanoparticles probably due to the surface oxidation of gold nanoparticles. A higher laser intensity resulted in a higher efficiency of gold NPs fabrication, which was attributed to a larger effective volume of the reaction.

36 MATERIALS SCIENCE↗

L-shell spectroscopy of Au as a temperature diagnostic tool

In order to develop plasma diagnostic for reduced-size hot Hohlraums under laser irradiation, we have studied the L-shell emission from highly charged gold ions in the SuperEBIT electron beam ion trap. The resolving power necessary to identify emission features from individual charge states in a picket-fence pattern has been estimated, and the observed radiation features have been compared with atomic structure calculations. We find that the strong 3d{sub 5/2}{yields}2p{sub 3/2} emission features are particularly useful in determining the charge state distribution and average ion charge <Z>, which are strongly sensitive to the electron temperature.

07 ISOTOPE AND RADIATION SOURCES↗

A new luminescence beam profile monitor for intense proton and heavy ion beams

A new luminescence beam profile monitor is realized in the polarized hydrogen gas jet target at the Relativistic Heavy Ion Collider (RHIC) facility. In addition to the spin polarization of the proton beam being routinely measured by the hydrogen gas jet, the luminescence produced by beam-hydrogen excitation leads to a strong Balmer series lines emission. A selected hydrogen Balmer line is spectrally filtered and imaged to produce the transverse RHIC proton beam shape with unprecedented details on the RHIC beam profile. Alternatively, when the passage of the high energy RHIC gold ion beam excited only the residual gas molecules in the beam path, sufficient ion beam induced luminescence is produced and the transverse gold ion beam profile is obtained. The measured transverse beam sizes and the calculated emittances provide an independent confirmation of the RHIC beam characteristics and to verify the emittance conservation along the RHIC accelerator. This optical beam diagnostic technique by making use of the beam induced fluorescence from injected or residual gas offers a truly noninvasive particle beam characterization, and provides a visual observation of proton and heavy ion beams. Combined with a longitudinal bunch measurement system, a 3-dimensional spatial particle beam profile can be reconstructed tomographically.

08 HYDROGEN↗

Liquid metal alloy ion source based metal ion injection into a room-temperature electron beam ion source

We have carried out a series of measurements demonstrating the feasibility of using the Dresden electron beam ion source (EBIS)-A, a table-top sized, permanent magnet technology based electron beam ion source, as a charge breeder. Low charged gold ions from an AuGe liquid metal alloy ion source were injected into the EBIS and re-extracted as highly charged ions, thereby producing charge states as high as Au{sup 60+}. The setup, the charge breeding technique, breeding efficiencies as well as acceptance and emittance studies are presented.

43 PARTICLE ACCELERATORS↗

Annealing Effects on the Surface Plasmon of MgO Implanted with Gold

Gold ion implantation was carried out with the energy of 1.1 MeV into (100) oriented MgO single crystal. Implanted doses are 1, 3, 6, 10 x 10(exp 16) ions/sq cm. The gold irradiation results in the formation of gold ion implanted layer with a thickness of 0.2 microns and defect formation. In order to form gold colloids from the as-implanted samples, we annealed the gold implanted MgO samples in three kinds of atmospheres: (1)Ar only, (2)H2 and Ar, and (3)O2 and Ar. The annealing over 1200 C enhanced the gold colloid formation which shows surface plasmon resonance band of gold. The surface plasmon bands of samples annealed in three kinds of atmospheres were found to be at 535 nm (Ar only), 524 nm(H2+Ar), and 560 nm (02+Ar), The band positions of surface plasmon can be reversibly changed by an additional annealing.

Ueda, A.↗

A New Luminescence Beam Profile Monitor for Intense Proton and Heavy Ion Beams

A new luminescence beam profile monitor is realized in the polarized hydrogen gas jet target at the Relativistic Heavy Ion Collider (RHIC) facility. In addition to the spin polarization of the proton beam being routinely measured by the hydrogen gas jet, the luminescence produced by beam-hydrogen excitation leads to a strong Balmer series lines emission. A selected hydrogen Balmer line is spectrally filtered and imaged to produce the transverse RHIC proton beam shape with unprecedented details on the RHIC beam profile. Alternatively, when the passage of the high energy RHIC gold ion beam excited only the residual gas molecules in the beam path, sufficient ion beam induced luminescence is produced and the transverse gold ion beam profile is obtained. The measured transverse beam sizes and the calculated emittances provide an independent confirmation of the RHIC beam characteristics and to verify the emittance conservation along the RHIC accelerator. This optical beam diagnostic technique by making use of the beam induced fluorescence from injected or residual gas offers a truly noninvasive particle beam characterization, and provides a visual observation of proton and heavy ion beams. Combined with a longitudinal bunch measurement system, a 3-dimensional spatial particle beam profile can be reconstructed tomographically.

43 PARTICLE ACCELERATORS↗

Measurement of HOMs in the RHIC RF Cavities

The Relativistic Heavy Ion Collider (RHIC) consists of two counter rotating beams which collide at two different experiments (PHENIX at IP8 and STAR at IP6). The particles that are accelerated range from protons to gold ions and each accelerator ring has the capability to accelerate a different specie. Table 1 summarizes the main machine parameters. The RF system on both rings has to be able to capture, accelerate and store up to 120 bunches with an average total bunch intensity of 1.0 × 10 9 particles/bunch for gold ions and 2 × 10 11 for protons. In the case of heavy ions the RF system must capture the particles at injection, accelerate them through transition and transfer the bunches from the 28 MHz system to the 197 MHz system. The 28 MHz accelerating cavities operate with 300 kV before transition and 150 kV throughout the rest of the energy ramp for ions and the 197 MHz system operates with 4 MV total gap voltage. In the case of protons, since the particles are injected above transition, only acceleration and storage is needed and the 28 MHz RF cavity is used with a voltage of 300 kV while the 197 MHz system uses a much smaller voltage of 50 kV only to increase the synchrotron frequency spread and improve Landau damping.

43 PARTICLE ACCELERATORS↗

Intrabeam scattering studies with large-emittance-ratio ion beams in the Relativistic Heavy Ion Collider, and implications for the Electron-Ion Collider

The Electron-Ion Collider (EIC), to be constructed at Brookhaven National Laboratory, will collide polarized, high-energy electron beams with hadron beams, achieving peak luminosities of up to 1.0 x 10 34 cm -2 s -1 . To reach such high luminosity, the EIC will employ flat-beam collisions at the interaction point. The design transverse emittance ratio will be about 10:1 in the Hadron Storage Ring (HSR). Thanks to stochastic cooling and precise decoupling, we successfully generated and accelerated gold ion beams with a large emittance ratio of 11:1 in the Relativistic Heavy Ion Collider (RHIC). In this article, we present results of intrabeam scattering (IBS) measurements and modeling for large-emittance gold ion beams, both without and with controlled betatron coupling. To model the IBS growth, we use the formulas developed by Lebedev and Nagaitsev.

43 PARTICLE ACCELERATORS↗

A New Class of Single Event Hard Errors

This paper reports on hard errors induced by single ions in dynamic memories. For ions with atomic number below 80, hard errors in DRAMs appear to be similar to the hard errors reported in previous work on SRAMs. One feature of these hard errors is that they tend to recover gradually with time, because of annealing, and are thus partially recoverable. However, for gold ions, a second type of hard error was discovered which is not recoverable, and appears to be due to catastrophic internal shorting rather than small changes in leakage current. Thus, nonrecoverable errors will likely occur even in devices which eliminate the extreme sensitivity to leakage current that is inherent in 4-T SRAMs and DRAMs. It is important to understand the mechanism that is responsible for nonrecoverable errors, and investigate the effect of device scaling.

single event hard errors DRAM SRAM ions gold ions ↗

R&D ERL: Beam dynamics, parameters, and physics to be learned

The R&D ERL facility at BNL aims to demonstrate CW operation of ERL with average beam current in the range of 0.1-1 ampere, combined with very high efficiency of energy recovery. The ERL is being installed in one of the spacious bays in Bldg. 912 of the RHIC/AGS complex (Fig. 1). The bay is equipped with an overhead crane. The facility has a control room, two service rooms and a shielded ERL cave. The control room is located outside of the bay in a separate building. The single story house is used for a high voltage power supply for 1 MW klystron. The two-story unit houses a laser room, the CW 1 MW klystron with its accessories, most of the power supplies and electronics. The ERL R&D program has been started by the Collider Accelerator Department (C-AD) at BNL as an important stepping-stone for 10-fold increase of the luminosity of the Relativistic Heavy Ion Collider (RHIC) using relativistic electron cooling of gold ion beams with energy of 100 GeV per nucleon. Furthermore, the ERL R&D program extends toward a possibility of using 10-20 GeV ERL for future electron-hadron/heavy ion collider, MeRHIC/eRHIC. These projects are the driving force behind the development of ampere-class ERL technology, which will find many applications including light sources and FELs. The intensive R&D program geared towards the construction of the prototype ERL is under way: from development of high efficiency photo-cathodes to the development of new merging system compatible with emittance compensation.

43 PARTICLE ACCELERATORS↗

Measurement of interaction between antiprotons

In this paper, one of the primary goals of nuclear physics is to understand the force between nucleons, which is a necessary step for understanding the structure of nuclei and how nuclei interact with each other. Rutherford discovered the atomic nucleus in 1911, and the large body of knowledge about the nuclear force that has since been acquired was derived from studies made on nucleons or nuclei. Although antinuclei up to antihelium-4 have been discovered and their masses measured, little is known directly about the nuclear force between antinucleons. Here, we study antiproton pair correlations among data collected by the STAR experiment at the Relativistic Heavy Ion Collider (RHIC), where gold ions are collided with a centre-of-mass energy of 200 gigaelectronvolts per nucleon pair. Antiprotons are abundantly produced in such collisions, thus making it feasible to study details of the antiproton–antiproton interaction. By applying a technique similar to Hanbury Brown and Twiss intensity interferometry, we show that the force between two antiprotons is attractive. In addition, we report two key parameters that characterize the corresponding strong interaction: the scattering length and the effective range of the interaction. Our measured parameters are consistent within errors with the corresponding values for proton–proton interactions. Our results provide direct information on the interaction between two antiprotons, one of the simplest systems of antinucleons, and so are fundamental to understanding the structure of more-complex antinuclei and their properties.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The XPS depth profiling and tribological characterization of ion-plated gold on various metals

Friction properties were measured with a gold film; the graded interface between gold and nickel substrate; and the nickel substrate. All sliding was conducted against hard silicon carbide pins in two processes. In the adhesive process, friction arises primarily from adhesion between sliding surfaces. In the abrasion process, friction occurs as a result of the hard pin sliding against the film, indenting into it, and plowing a series of grooves. Copper and 440 C stainless steel substrates were also used. Results indicate that the friction related to both adhesion and abrasion is influenced by coating depth. The trends in friction behavior as a function of film depth are, however, just the opposite. The graded interface exhibited the highest adhesion and friction, while the graded interface resulted in the lowest abrasion and friction. The coefficient of friction due to abrasion is inversely related to the hardness. The greater the hardness of the surface, the lower is the abrasion and friction. The microhardness in the graded interface exhibited the highest hardness due to an alloy hardening effect. Almost no graded interface between the vapor-deposited gold film and the substrates was detected.

Miyoshi, K.↗

Generation of quasi-monoenergetic carbon ions accelerated parallel to the plane of a sandwich target

A new ion acceleration scheme, namely, target parallel Coulomb acceleration, is proposed in which a carbon plate sandwiched between gold layers is irradiated with intense linearly polarized laser pulses. The high electrostatic field generated by the gold ions efficiently accelerates the embedded carbon ions parallel to the plane of the target. The ion beam is found to be collimated by the concave-shaped Coulomb potential. As a result, a quasi-monoenergetic and collimated C{sup 6+}-ion beam with an energy exceeding 10 MeV/nucleon is produced at a laser intensity of 5 × 10{sup 19} W/cm{sup 2}.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Swift heavy ion irradiation-induced microstructure modification on two delta-phase oxides: Sc4Zr3O12 and Lu4Zr3O12

Swift gold ions (185 MeV) were used to systematically investigate the radiation damage response of delta phase compounds Sc{sub 4}Zr{sub 3}O{sub 12} and Lu{sub 4}Zr{sub 3}O{sub 12} in the electronic energy loss regime. Ion irradiation-induced microstructural modifications were examined using X-ray diffraction (XRD) and transmission electron microscopy (TEM). XRD investigations indicate a phase transformation from ordered rhombohedral to disordered fluorite (O-D) in both compounds, with the Sc compound transforming at a higher ion fluence compared with the Lu compound. This result is consistent with our previous study on Sc{sub 4}Zr{sub 3}O{sub 12} and Lu{sub 4}Zr{sub 3}O{sub 12} under displacive radiation environment in which the nuclear energy loss is dominant. High resolution TEM revealed that individual ion tracks maintains crystalline structure where the core region experiences an O-D phase transformation. TEM observation also suggests that the O-D phase transformation occurs through the ion range after overlapping of ion tracks.

36 MATERIALS SCIENCE↗