Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GLOVEBOXES”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Dexterity and Worker Comfort in an Ergonomically Designed Glovebox Glove

Gloveboxes are prolifically used in nuclear facilities as the primary means of separation between the hazardous material and operators. Due to extended duration and high repetition of hand tasks in glovebox gloves, improperly fitting gloves can be uncomfortable and increase injury risks. Poor fit can increase time necessary to perform work tasks and stress the glove itself. The Plutonium Facility has the largest inventory of glovebox gloves at Los Alamos National Laboratory (LANL) with approximately 6000 gloves installed. The current glove mold dates back to the 1960's and is not based on the true anatomy of the hand. Design flaws (poor anatomical fit and biomechanics) are directly related to injuries of the elbow (lateral epicondylitis) and thumb (DeQuervain's tenosynovitis) injuries. The current design also contributes to 30% of unplanned glove openings. A new glovebox glove was developed and manufactured, incorporating over forty dimensions to produce the most comprehensive ergonomically sound design. The new design received a LANL patent (patent attorney docket No: LANS 36USD1 'Protective Glove'), one of 20 highest patents awarded by the Richard P. Feynman Center for Innovation. A SolidWorks model was given to the manufacturer for production of the glove mold.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Uranium Prototype Glovebox and Furnace Design and Build (SPC-2954)

This specification contains the requirements for design, analysis, fabrication, testing and delivery of the Uranium Prototype Glovebox (UPG) and Furnace, and the associated equipment as described herein. The UPG will be primarily used for the containment of uranium and the prototyping of equipment to be used in higher hazard category gloveboxes. This will allow complex pieces of equipment to be tested in a less hazardous environment prior to fabrication and installation in other gloveboxes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Glovebox Fires Phase 1: Simulations of Open Burner Experiments

Understanding the duration of a fire required to breach a glovebox via glove ports and/or windows within a facility is important in developing mitigation strategies for safety. To facilitate this understanding, both simulation and experiments are utilized. The approach is to first validate the Computation Fluid Dynamics (CFD) code, Fire Dynamics Simulator (FDS), with experimental data collected by New Mexico Tech (NMT) and then perform simulations of full-scale rooms containing gloveboxes to assess numerous scenarios which would otherwise be cost-prohibitive experimentally. This report provides comparison to first-phase experiments involving a fire without a glovebox. A subsequent report will provide comparison to experiments involving a glovebox. The results indicate good agreement with FDS tending to over predict the pre-mixed and diffusion-mode tests by 6% and 10%, respectively.

42 ENGINEERING↗

Molten Salt Electrochemical Reactors Outside of a Glovebox

Molten salt electrochemical reduction (MSER) offers an electrified method for the reduction, refining, and recycling of metals such as iron and metallurgical grade silicon at high efficiency and lower temperatures than traditional methods, which use temperatures >1000C and carbon-based reductants. However, salts appropriate for MSER are moisture and air sensitive, necessitating air-free methods of processing and testing which is often acomplished with a glovebox. Glovebox operations are cumbersome and difficult to troubleshoot reactor issues. We have developed a robust method of testing chloride and carbonate salts in molten salt reactors outside of a glovebox for silicon and carbon production and steel carburization. We highlight a practical guide for glovebox-free testing of molten salt electrochemical reactors to reduce the barriers to performing this type of work. Our aim is to enable other research groups to step into this field with simple and repeatable reactor configurations.

47 OTHER INSTRUMENTATION↗

Design concepts for the Centrifuge Facility Life Sciences Glovebox

The Life Sciences Glovebox will provide the bioisolated environment to support on-orbit operations involving non-human live specimens and samples for human life sceinces experiments. It will be part of the Centrifuge Facility, in which animal and plant specimens are housed in bioisolated Habitat modules and transported to the Glovebox as part of the experiment protocols supported by the crew. At the Glovebox, up to two crew members and two habitat modules must be accommodated to provide flexibility and support optimal operations. This paper will present several innovative design concepts that attempt to satisfy the basic Glovebox requirements. These concepts were evaluated for ergonomics and ease of operations using computer modeling and full-scale mockups. The more promising ideas were presented to scientists and astronauts for their evaluation. Their comments, and the results from other evaluations are presented. Based on the evaluations, the authors recommend designs and features that will help optimize crew performance and facilitate science accommodations, and specify problem areas that require further study.

Sun, Sidney C.↗

Glovebox - an Excellent Environment for Microgravity Experiments

The use of the Spacelab Glovebox on the recent First United States Microgravity Laboratory (USML-1) mission and the success with which the facility accommodated a large number of microgravity experiments are discussed. Sixteen Materials Science experiments were developed and successfully operated during the first microgravity usage of this new glovebox in space. This facility has a closed working volume to safely contain loose particles and droplets that may be inadvertently freed in setting up or conducting the experiments. The facility also offers an excellent photographic laboratory for observing and recording science data. The USML-1 Spacelab Globebox was a highly successful project that provided the motivation to begin the development of an Orbiter Middeck Glovebox and also provided valuable experience in setting the requirements for the Space Station Freedom Microgravity Science Glovebox (MSG).

Chassay, Roger P.↗

Automation of Command and Data Entry in a Glovebox Work Volume: An Evaluation of Data Entry Devices

The present study was designed to examine the human-computer interface for data entry while performing experimental procedures within a glovebox work volume in order to make a recommendation to the Space Station Biological Research Project for a data entry system to be used within the Life Sciences Glovebox. Test subjects entered data using either a manual keypad, similar to a standard computer numerical keypad located within the glovebox work volume, or a voice input system using a speech recognition program with a microphone headset. Numerical input and commands were programmed in an identical manner between the two systems. With both electronic systems, a small trackball was available within the work volume for cursor control. Data, such as sample vial identification numbers, sample tissue weights, and health check parameters of the specimen, were entered directly into procedures that were electronically displayed on a video monitor within the glovebox. A pen and paper system with a 'flip-chart' format for procedure display, similar to that currently in use on the Space Shuttle, was used as a baseline data entry condition. Procedures were performed by a single operator; eight test subjects were used in the study. The electronic systems were tested under both a 'nominal' or 'anomalous' condition. The anomalous condition was introduced into the experimental procedure to increase the probability of finding limitations or problems with human interactions with the electronic systems. Each subject performed five test runs during a test day: two procedures each with voice and keypad, one with and one without anomalies, and one pen and paper procedure. The data collected were both quantitative (times, errors) and qualitative (subjective ratings of the subjects).

Steele, Marianne K.↗

Overview of the Microgravity Science Glovebox (MSG)

MSG is a third generation glovebox for Microgravity Science investigations: SpaceLab Glovebox (GBX); Middeck/MIR Gloveboxes (M/MGBX); and GBX and M/MGBX developed by Bradford Engineering (NL). Previous flights have demonstrated utility of glovebox facilities: Contained environment enables broader range of science experiments; Affords better control of video and photographic imaging (a prime data source); Provides better environmental control than cabin atmosphere; and Useful for contingency operations. MSG developed in response to demands for increased work volume, increased capabilities and additional resources. MSG is multi-user facility to support a wide range of small science and technology investigations: Fluid physics; Combustion science; Material science; Biotechnology (cell culturing and protein crystal growth); Space processing; Fundamental physics; and Technology demonstrations. Topics included in this viewgraph are: MSG capabilities; MSG hardware items; MSG, GSE, and OSE items; MSG development approach; and Science utilization.

Wright, Mary Etta↗

The g-LIMIT Microgravity Vibration Isolation System for the Microgravity Science Glovebox

For many microgravity science experiments in the International Space Station, the ambient acceleration environment will be exceed desirable levels. To provide a more quiescent acceleration environment to the microgravity payloads, a vibration isolation system named g-LIMIT (GLovebox Integrated Microgravity Isolation Technology) is being designed. g-LIMIT is a sub-rack level isolation system for the Microgravity Science Glovebox that can be tailored to a variety of applications. Scheduled for launch on the UF-1 mission, the initial implementation of g-LIMIT will be a Characterization Test in the Microgravity Science Glovebox. g-LIMIT will be available to glovebox investigators immediately after characterization testing. Standard MSG structural and umbilical interfaces will be used so that the interface requirements are minimized. g-LIMIT consists of three integrated isolator modules, each of which is comprised of a dual axis actuator, two axes of acceleration sensing, two axes of position sensing, control electronics, and data transmission capabilities in a small-volume package. In addition, this system provides the unique capability for measuring quasi-steady acceleration of the experiment independent of accelerometers as a by-product of the control system and will have the capability of generating user-specified pristine accelerations to enhance experiment operations.

Whorton, Mark S.↗

Lunar Glovebox Balance with Wireless Technology

The most important equipment required for processing lunar samples is a high-quality mass balance for maintaining accurate weight inventory, security, and scientific study. After careful review, a Curation Office memo by Michael Duke in 1978 chose the Mettler PL200 to be used for sample weight measurements inside the gloveboxes (Fig. 3). These commercial off-the-shelf (COTS) balances did not meet the strict accepted material requirements in the Lunar lab. As a result, each balance housing, weighing pan, and wiring was custom retrofitted to meet Lunar Operating Procedure (LOP) 54 requirements [for material construction restrictions]. The original design drawings for the custom housings, readout support stands, and wiring were done by the JSC engineering directorate. The 1977- 1978 schematics, drawings, and files are now housed in the curation Data Center. Per the design specifications, the housing was fabricated from aluminum grade 6061 T6, seamless welds, and anodized per MIL-A-8625 type I, class I. The balance feet were TFE Teflon and any required joints were sealed with Viton A gaskets. The readout display and support stands outside the glovebox were fabricated from 300 series stainless steel with #4 finish and mounted to the glovebox with welded bolts. Wire harnesses that linked the balance with the outside display and power were encapsulated with TFE Teflon and transported through custom Deutsch wire bulk head pass-through systems from inside to outside the glovebox. These Deutsch connectors were custom fabricated with 316L stainless steel bodies, Viton A O-rings, aluminum 6061 with electroless nickel plating, Teflon (replacing the silicone), and gold crimp connectors (no soldering). Many of the Deutsch connectors may have been used in the Apollo program high vacuum complex in building 37 and date to about 1968 to 1970.

Zeigler, Ryan A.↗

2014 AFCI Glovebox Event Executive Summary

One of the primary INL missions is to support development of advanced fuels with the goal of creating reactor fuels that produce less waste and are easier to store. The Advanced Fuel Cycle Initiative (AFCI) Glovebox in the Fuel Manufacturing Facility (FMF) is used for several fuel fabrication steps that involve transuranic elements, including americium. The AFCI glove box contains equipment used for fuel fabrication, including an arc melter – a small, laboratory-scale version of an electric arc furnace used to make new metal alloys for research – and an americium distillation apparatus. This overview summarizes key findings related to the investigation into the releases of airborne radioactivity that occurred in the AFCI glovebox room in late August and early September 2014. The full report (AFCI Glovebox Radiological Release – Evaluation, Corrective Actions and Testing, INL/INL-15-36996) provides details of the identified issues, corrective actions taken as well as lessons learned

42 ENGINEERING↗

Rotator cuff strength balance in glovebox workers

Gloveboxes are essential to the pharmaceutical, semi-conductor, nuclear, and biochemical industries. While gloveboxes serve as effective containment systems, they are often difficult to work in and present a number of ergonomic hazards. One such hazard is injury to the rotator cuff, a group of tendons and muscles in the shoulder, connecting the upper arm to the shoulder blade. Rotator cuff integrity is critical to shoulder health. This study compared the rotator cuff muscle strength ratios of glovebox workers to the healthy norm. Descriptive statistics were collected using a short questionnaire. Handheld dynamometry was used to quantify the ratio of forces produced for shoulder internal and external rotation. Results showed this population to have shoulder strength ratios significantly different from the healthy norm. Strength ratios were found to be a sound predictor of symptom incidence. The deviation from the normal ratio demonstrates the need for solutions designed to reduce the workload on the rotator cuff musculature in order to improve health and safety. Assessment of strength ratios can be used to screen for risk of symptom development. As a result, this increases technical knowledge and augments operational safety.

60 APPLIED LIFE SCIENCES↗

A human factors approach towards the design of a new glovebox glove for Los Alamos National Laboratory

Present day glovebox gloves at Los Alamos National Laboratory (LANL) are underdeveloped and ergonomically inaccurate. This problem results in numerous sprain and strain injuries every year for employees who perform glovebox work. In addition to injuries, using the current glovebox glove design also contributes to breaches and contamination. The current glove used today at LANL has several problems: (1) The length of the fingers is incorrect, (2) the web spacing between the fingers is nonexistent, (3) the angles between each digit on the finger are incorrect, (4) the thumb is placed inaccurately, and (5) the length of the hand is incorrect.

42 ENGINEERING↗

Rotator Cuff Strength Ratio and Injury in Glovebox Workers

Rotator cuff integrity is critical to shoulder health. Due to the high workload imposed upon the shoulder while working in an industrial glovebox, this study investigated the strength ratio of the rotator cuff muscles in glovebox workers and compared this ratio to the healthy norm. Descriptive statistics were collected using a short questionnaire. Handheld dynamometry was used to quantify the ratio of forces produced in the motions of shoulder internal and external rotation. Results showed this population to have shoulder strength ratios that were significantly different from the healthy norm. The deviation from the normal ratio demonstrates the need for solutions designed to reduce the workload on the rotator cuff musculature of glovebox workers in order to improve health and safety. Assessment of strength ratios can be used to screen for risk of symptom development.

99 GENERAL AND MISCELLANEOUS↗

Evaluation of Cease Fire CFP 640 for Use in Gloveboxes (Final Report)

A Los Alamos National Laboratory (LANL) task group was established to discuss and evaluate a candidate fire suppression system (FSS) for gloveboxes (GB) and dropboxes (DB, for brevity, this report will simply refer to gloveboxes). Suitability criteria include compliance, compatibility, and capability. LANL contracted with New Mexico Tech (NMT) to quantitatively evaluate the perfor mance of one of those systems including its ability to extinguish GB fires, limit over-pressurization of the GB, etc. Additionally, the results of these experiments provide data points that could be used when fire hazard evaluations (FHEs) are conducted for determining when to require a fire suppres sion system installation within a GB (as required by NFPA 801, Standard for Facilities Handling Radioactive Materials, DOE Standard 1066-2012 Fire Protection, and AGS-G010-2011 Standard of Practice for Glovebox Fire Protection).

42 ENGINEERING↗

Alternative approach for fire suppression of class A, B and C fires in gloveboxes

Department of Energy (DOE) Orders and National Fire Protection Association (NFPA) Codes and Standards require fire suppression in gloveboxes. Several potential solutions have been and are currently being considered at Los Alamos National Laboratory (LANL). The objective is to provide reliable, minimally invasive, and seismically robust fire suppression capable of extinguishing Class A, B, and C fires; achieve compliance with DOE and NFPA requirements; and provide value-added improvements to fire safety in gloveboxes. This report provides a brief summary of current approaches and also documents the successful fire tests conducted to prove that one approach, specifically Fire Foe{trademark} tubes, is capable of achieving the requirement to provide reliable fire protection in gloveboxes in a cost-effective manner.

99 GENERAL AND MISCELLANEOUS↗

Retrofit of an Engineered Glove-port to a Los Alamos National Laboratory's Plutonium Facility Glovebox

At the Los Alamos National Laboratory's Plutonium Facility (TA-55), various isotopes of plutonium along with other actinides are routinely handled such that the spread of radiological contamination and excursions of contaminants into the operator's breathing zone are prevented through the use of a variety of gloveboxes (the glovebox coupled with adequate negativity providing primary confinement). The current technique for changing glovebox gloves are the weakest part of this engineering control. 1300 pairs of gloves are replaced each year at TA-55, generating approximately 500 m{sup 3}/yr of transuranic (TRU) waste and Low Level Waste (LLW) waste that represents an annual disposal cost of about 4 million dollars. By retrofitting the LANL 8'' glove-port ring, a modern 'Push-Through' technology is utilized. This 'Push-Through' technology allows relatively fast glove changes to be done by operators with much less training and experience and without breaching containment. A dramatic reduction in waste is realized; exposure of the worker to residual contamination reduced, and the number of breaches due to installation issues is eliminated. In the following presentation, the evolution of the 'Push- Through' technology, the features of the glove-port retrofit, and waste savings are discussed. (author)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Towards Cooperative Control of Humanoid Robots for Handling High-Consequence Materials in Gloveboxes - 17291

In this paper, we describe our ongoing work with NASA's Valkyrie humanoid robot and present preliminary results on cooperative control of Valkyrie's hands for performing dexterous manipulation tasks inside gloveboxes commonly found in many nuclear facilities. First, we discuss our human-supervised robot control framework which is based on optimization-based whole-body motion and manipulation controllers. A key aspect of this approach is perception based grasping. We develop a grasping control module for realizing the grasps corresponding to sample tasks such as power, ball, key, pinch, and open palm grasps and their variations. Next, we introduce the notion of motion template library in order to develop generalizable robot grasping and manipulation. Motion template library stores the constraint setting information for the constrained motion planning methods and a framework which can implement the motion template library on different types of robots for accomplishing similar tasks. Motion templates are defined only based on the task requirements. As a result, they can be easily ported to different robot platforms. Lastly, we discuss our multi-modal interfaces designs which include a visual display for improved situational awareness as well as a tactile glove for robot hand control and feedback. Our goal is for the person tele-operating the Valkyrie robot to have better sensing and control than what he or she would have if actually standing at the glovebox doing the work. This improved sensing is comprised of the ability to 'see through' the robot's arms and hands in the gloves and to have an improved sense of touch. The paper concludes with a discussion of our validation strategy. Our success metrics are derived from the completion of a relatively complex experiment to be performed in the glovebox. We evaluate various realistic experiments and use them for task validation and demonstration with Valkyrie. We use speed, time of completion, accuracy, repeatability and reliability rates as success metrics by designing replicable experiments. (authors)

42 ENGINEERING↗