Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GHZ RANGE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Application of high-precision two-way ranging to Galileo Earth-1 encounter navigation

The application of precision two-way ranging to orbit determination with relatively short data arcs is investigated for the Galileo spacecraft's approach to its first Earth encounter (December 8, 1990). Analysis of previous S-band (2.3-GHz) ranging data acquired from Galileo indicated that under good signal conditions submeter precision and 10-m ranging accuracy were achieved. It is shown that ranging data of sufficient accuracy, when acquired from multiple stations, can sense the geocentric angular position of a distant spacecraft. A range data filtering technique, in which explicit modeling of range measurement bias parameters for each station pass is utilized, is shown to largely remove the systematic ground system calibration errors and transmission media effects from the Galileo range measurements, which would otherwise corrupt the angle-finding capabilities of the data. The accuracy of the Galileo orbit solutions obtained with S-band Doppler and precision ranging were found to be consistent with simple theoretical calculations, which predicted that angular accuracies of 0.26-0.34 microrad were achievable. In addition, the navigation accuracy achieved with precision ranging was marginally better than that obtained using delta-differenced one-way range (delta DOR), the principal data type that was previously used to obtain spacecraft angular position measurements operationally.

Pollmeier, V. M.↗

A Low-Cost, Reconfigurable UWB Microwave Radar Front-End for Fine Resolution Nadir-Looking Measurements of Snow and Layered Media

This paper presents a reconfigurable, low-cost ultra-wideband microwave radar front-end and radar demonstrator designed for nadir-looking measurements of layered media (e.g. snow or vegetation) from either a fast-moving ground-based platform or a C-3 class unmanned aerial system (UAS). The radar demonstrator uses a frequency modulated continuous-wave (FMCW) architecture and can be configured to operate in either the 2-8 GHz or in the 12-18 GHz range, providing fine vertical resolution while offering a significantly reduced weight, size, and power consumption with respect to prior implementations. We have demonstrated the operation of the system in the 2-8 GHz and 12-18 GHz bands in the laboratory; in the 2-8 GHz band using a surface-based setup in Antarctica; and in the 2.6-7 GHz band on local flight tests onboard an Aurelia X6 Pro UAS equipped with 3-D printed antennas. This paper provides an overview of the radar front-end and demonstrator design and implementation and a summary of the different tests completed to document their performance.

UWB radar, UAS-borne radar, snow-probing radar.↗

Cryogenic, low-noise high electron mobility transistor amplifiers for the Deep Space Network

The rapid advances recently achieved by cryogenically cooled high electron mobility transistor (HEMT) low-noise amplifiers (LNA's) in the 1- to 10-GHz range are making them extremely competitive with maser amplifiers. In order to address future spacecraft navigation, telemetry, radar, and radio science needs, the Deep Space Network is investing both maser and HEMT amplifiers for its Ka-band (32-GHz) downlink capability. This article describes the current state cryogenic HEMT LNA development at Ka-band for the DSN. Noise performance results at S-band (2.3 GHz) and X-band (8.5 GHz) for HEMT's and masers are included for completeness.

Bautista, J. J.↗

Advanced Microwave Precipitation Radiometer (AMPR) for remote observation of precipitation

The design, development, and tests of the Advanced Microwave Precipitation Radiometer (AMPR) operating in the 10 to 85 GHz range specifically for precipitation retrieval and mesoscale storm system studies from a high altitude aircraft platform (i.e., ER-2) are described. The primary goals of AMPR are the exploitation of the scattering signal of precipitation at frequencies near 10, 19, 37, and 85 GHz together to unambiguously retrieve precipitation and storm structure and intensity information in support of proposed and planned space sensors in geostationary and low earth orbit, as well as storm-related field experiments. The development of AMPR will have an important impact on the interpretation of microwave radiances for rain retrievals over both land and ocean for the following reasons: (1) A scanning instrument, such as AMPR, will allow the unambiguous detection and analysis of features in two dimensional space, allowing an improved interpretation of signals in terms of cloud features, and microphysical and radiative processes; (2) AMPR will offer more accurate comparisons with ground-based radar data by feature matching since the navigation of the ER-2 platform can be expected to drift 3 to 4 km per hour of flight time; and (3) AMPR will allow underflights of the SSM/I satellite instrument with enough spatial coverage at the same frequencies to make meaningful comparisons of the data for precipitation studies.

Galliano, J. A.↗

GaAs single-drift flat-profile IMPATT diodes for CW operation at D band

Single-drift flat-profile GaAs IMPATT diodes were designed for CW operation in the 140 GHz range. The diodes were fabricated from MBE grown material, mounted on diamond heatsinks, and tested in a radial line full height waveguide cavity. An RF output power of 15 mW with a corresponding DC to RF conversion efficiency of 1.5 percent was obtained at 135.3 GHz.

Eisele, H.↗

The development of an advanced microwave precipitation radiometer for future airborne measurements

An account is given of the development and preliminary testing of the Advanced Microwave Precipitation Radiometer (AMPR) for 10-85 GHz range precipitation retrieval and mesoscale storm-system studies conducted by ER-2 aircraft. AMPR exploits precipitation scattering signals to unambiguously retrieve precipitation and storm-structure intensity data. Attention is given to the AMPR's multifrequency feedhorn, which furnishes dual-polarization ports at 19.35, 37.0, and 85.5 GHz; the 10.7 GHz channel uses a separate horn/lens antenna with single polarization. The AMPR-equipped ER-2 will underfly the SSM/I space instrument to allow data comparisons of comparable spatial coverage.

Galliano, J. A.↗

166 GHz Ice Scattering Signal in Cold-Season Precipitating Cloud Systems

Surface snowfall can be produced by a variety of forcing mechanisms that are accompanied by different in-cloud physical processes and microphysical composition. For instance, shallow cumuliform snowfall forced by marine cold air outbreaks shows distinct geographic and seasonal signatures and plays in important role in annual snowfall production in many regions worldwide. Coincident CloudSat-CALIPSO observations confirm that oceanic regions exhibiting frequent shallow cumuliform snow are typically composed of mixed-phase cloud and precipitation particles and display passive microwave brightness temperature behavior that is dominated by cloud liquid water emission, while combined Global Precipitation Measurement (GPM) radiometer and surface radar studies of intense shallow cumuliform events indicate significant ice particle scattering signals at the highest GPM radiometer frequencies. Passive microwave imager channels in the 37 to 89 GHz range have long been used to detect precipitation-sized ice particle scattering signatures in clouds. Dual polarization plays an important role in distinguishing between scattering signatures and other background variability. The GPM Microwave Imager (GMI) is the first satellite radiometer to possess dual-polarized channels at 166 GHz. These high-frequency channels are more susceptible to emission and attenuation by cloud liquid water and water vapor than lower-frequency channels, but are also more sensitive to ice scattering. This research studies the ice scattering information contained in the 166 GHz channels compared to the historically used 85/89 GHz channels on previous sensors. A 166 GHz scattering index (SI) will be developed to understand how its correlation with non-precipitating ice scattering at higher altitudes also affects the 166 GHz scattering signature in cold-season precipitating cloud systems. The 166 GHz SI will be used to possibly isolate precipitation scattering signature for different snowfall modes (shallow convective vs. deep stratiform). The supercooled liquid water affecting shallow convective systems and drastically reducing the scattering signal could be detected and quantified, providing additional information for convective snow detection and quantification in solid precipitation retrieval algorithms.

Lisa Milani↗

Surface Wave Based Non-conductor-contact Reflectometry Method for Insulation and Jacket Damage Detection in Multi-Conductor Cables

This paper presents a non-conductor-contact surface wave reflectometry technique to locate insulation and jacket damage on multi-conductor cables at a distant location from the sensor. Simulation studies were conducted using Ansys high frequency structure simulator (HFSS). A GHz range surface wave launcher was employed such that maximum surface wave energies were confined in the insulation layer while minimizing attenuation. The wave launcher can potentially be mounted on the outer surface of live cables or cable conduits and requires no physical connection to the conductors. Multiple simulations involving a 4 GHz wave launcher and a three-conductor cable with an 8 mm outer diameter were carried out demonstrating the efficacy of the proposed method. Water leak and different types of insulation/jacket damage were simulated and detected.

reflectometry, multi-conductor cable, frequency do↗

Zone plate lens antennas for millimeter and submillimeter wavelengths

Zone plate lenses are a type of focusing element which function essentially as differential phase shifters, having a relatively few, coarsely quantized phase delays across the incident beam of radiation. The major advantages are ease of fabrication and much reduced thickness, compared to conventional refractive focusing elements. These considerations are both of particular importance for the submillimeter range, in which manufacturing tolerances for curved optical elements can pose significant problems, and where the absorption of readily available dielectric materials is quite large. In this presentation we briefly review the theory of zone plate lens operations, present a relatively simple method for calculating the aperture efficiency of zone plate lenses used as antennas, and show some theoretical and measured results in the 100 GHz range.

Goldsmith, Paul F.↗

Low-noise room-temperature and cryogenic mixers for 80-120 GHz

A description is given of two new mixers designed to operate in the 80-120-GHz range on 36-ft radio telescope. It is shown that for a hard-driven diode the parasitic resistance and capacitance are the primary factors influencing the design of the diode mount. A room-temperature mixer is described which achieves a single-sideband (SSB) conversion loss (L) of 5.5 dB, and a SSB noise temperature (Tm) of 500 K (excluding the IF contribution) with a 1.4-GHz IF. A cryogenically cooled version, using a quartz structure to support the diode chip and contact whisker, achieves values of L = 5.8 dB and Tm = 300 K with a 4.75-GHz IF. The mixers use high-quality Schottky-barrier diodes in a one-quarter-height waveguide mount.

Kerr, A. R.↗

Airborne Microwave Radiometry on a Semi-Arid Area During HAPEX-Sahel

Airborne microwave radiometric measurements in the framework of the HAPEX-Sahel Experiment were performed by the Push Broom Microwave Radiometer (PBMR) and the PORTOS radiometer. The flights of both radiometers produced an original set of data covering the 1.4-90 GHz range of frequency. The East and West Central Super Sites were the areas most intensively observed by the microwave radiometers. Over those sites, several brightness temperature (TB) maps are available at seven dates distributed over a 1 month period in the middle of the rainy season. A comparison of the two radiometers demonstrates their radiometric quality and the precision of the localization of the microwave observations. At 1.4 GHz, the vegetation had very little effect on the soil microwave emission. Maps of soil moisture were developed using a single linear relationship between TB and the surface soil moisture. There is an important spatial heterogeneity in the soil moisture distribution, which is explained by both the soil moisture hydrodynamic properties and the localization of the precipitation fields. At 5.05 GHz, the vegetation must be accounted for to infer soil moisture from the microwave observations. A method based on a simple radiative transfer model and on microwave data has shown encouraging results.

Chanzy, A↗

Waveguide Transition for Submillimeter-Wave MMICs

An integrated waveguide-to-MMIC (monolithic microwave integrated circuit) chip operating in the 300-GHz range is designed to operate well on high-permittivity semiconductor substrates typical for an MMIC amplifier, and allows a wider MMIC substrate to be used, enabling integration with larger MMICs (power amplifiers). The waveguide-to- CBCPW (conductor-backed coplanar waveguide) transition topology is based on an integrated dipole placed in the E-plane of the waveguide module. It demonstrates low loss and good impedance matching. Measurement and simulation demonstrate that the loss of the transition and waveguide loss is less than 1-dB over a 340-to-380-GHz bandwidth. A transition is inserted along the propagation direction of the waveguide. This transition uses a planar dipole aligned with the maximum E-field of the TE10 waveguide mode as an inter face between the waveguide and the MMIC. Mode conversion between the coplanar striplines (CPS) that feed the dipole and the CBCPW transmission line is accomplished using a simple air-bridge structure. The bottom side ground plane is truncated at the same reference as the top-side ground plane, leaving the end of the MMIC suspended in air.

Leong, Kevin M.↗

High-Altitude MMIC Sounding Radiometer for the Global Hawk Unmanned Aerial Vehicle

Microwave imaging radiometers operating in the 50-183 GHz range for retrieving atmospheric temperature and water vapor profiles from airborne platforms have been limited in the spatial scales of atmospheric structures that are resolved not because of antenna aperture size, but because of high receiver noise masking the small variations that occur on small spatial scales. Atmospheric variability on short spatial and temporal scales (second/ km scale) is completely unresolved by existing microwave profilers. The solution was to integrate JPL-designed, high-frequency, low-noise-amplifier (LNA) technology into the High-Altitude MMIC Sounding Radiometer (HAMSR), which is an airborne microwave sounding radiometer, to lower the system noise by an order of magnitude to enable the instrument to resolve atmospheric variability on small spatial and temporal scales. HAMSR has eight sounding channels near the 60-GHz oxygen line complex, ten channels near the 118.75-GHz oxygen line, and seven channels near the 183.31-GHz water vapor line. The HAMSR receiver system consists of three heterodyne spectrometers covering the three bands. The antenna system consists of two back-to-back reflectors that rotate together at a programmable scan rate via a stepper motor. A single full rotation includes the swath below the aircraft followed by observations of ambient (roughly 0 C in flight) and heated (70 C) blackbody calibration targets located at the top of the rotation. A field-programmable gate array (FPGA) is used to read the digitized radiometer counts and receive the reflector position from the scan motor encoder, which are then sent to a microprocessor and packed into data files. The microprocessor additionally reads telemetry data from 40 onboard housekeeping channels (containing instrument temperatures), and receives packets from an onboard navigation unit, which provides GPS time and position as well as independent attitude information (e.g., heading, roll, pitch, and yaw). The raw data files are accessed through an Ethernet port. The HAMSR data rate is relatively low at 75 kbps, allowing for real-time access over the Global Hawk high-data-rate downlink. Once on the ground, the raw data are unpacked and processed through two levels of processing. The Level 1 product contains geo-located, time-stamped, calibrated brightness temperatures for the Earth scan. These data are then input to a lD variational retrieval algorithm to produce temperature, water vapor, and cloud liquid water profiles, as well as several derived products such as potential temperature and relative humidity.

Brown, Shannon T.↗

Exploration of Wire Array Metamaterials for the Plasma Axion Haloscope

A plasma haloscope has recently been proposed as a feasible approach to extend the search for dark matter axions above 10 GHz (≈40 μeV), whereby the microwave cavity in a conventional axion haloscope is supplanted by a wire array metamaterial. Since the plasma frequency of a metamaterial is determined by its unit cell, and is thus a bulk property, a metamaterial resonator of any frequency can be made arbitrarily large, in contrast to a microwave cavity which incurs a steep penalty in volume with increasing frequency. To assess the actual potential of this concept as a practical dark matter haloscope, the basic properties of wire array metamaterials have been investigated through an extensive series of S 21 measurements in the 10 GHz range. This report presents some new systematics of wire array metamaterials themselves including the approach to full plasmonic behavior, the applicability of the semianalytic theory of Belov, and estimates of the loss term which bode favorably for the plasmonic haloscope application. This present work constitutes the first precision test of the semianalytic theory of Belov et al., for which the predicted plasma frequency agrees with the experimental value at the 0.1% level.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radio-Frequency Resonances and Damping in Metallic Magnetic Calorimeter Sensors

Metallic magnetic calorimeters (MMCs) are particle detectors that combine ultra-high energy resolution with a predictable and smooth response based on the physics of paramagnetism. For best energy resolution, MMCs are read out with dc SQUID preamplifiers. Since the ac Josephson effect also makes dc SQUIDs broadband RF sources in the 1–100 GHz range, the SQUID can potentially excite RF modes of the MMC sensor, with negative consequences. Further, the importance of this possibility is magnified in direct-coupled MMCs, where the MMC sensor is part of the SQUID loop to maximize performance. For these reasons, the RF behavior of MMC sensors must be investigated. In this report, we present the results of exploratory RF simulations of MMC sensor modes and damping, and we assess three approaches to damp the parallel-meander direct-coupled MMC without excessive noise increase.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Capturing CO 2 in Quadrupolar Binding Pockets: Broadband Microwave Spectroscopy of Pyrimidine-(CO 2 ) n , n = 1,2

Pyrimidine has two in-plane CH(δ+)/N̈(δ–)/CH(δ+) binding sites that are complementary to the (δ–/2δ+/δ–) quadrupole moment of CO 2 . For this study, we recorded broadband microwave spectra over the 7.5–17.5 GHz range for pyrimidine-(CO 2 ) n with n = 1 and 2 formed in a supersonic expansion. Based on fits of the rotational transitions, including nuclear hyperfine splitting due to the two 14 N nuclei, we have assigned 313 hyperfine components across 105 rotational transitions for the n = 1 complex and 208 hyperfine components across 105 rotational transitions for the n = 2 complex. The pyrimidine-CO 2 complex is planar, with CO 2 occupying one of the quadrupolar binding sites, forming a structure in which the CO 2 is stabilized in the plane by interactions with the C–H hydrogens adjacent to the nitrogen atom. This structure is closely analogous to that of the pyridine-CO 2 complex studied previously by (Doran, J. L. J. Mol. Struct. 2012, 1019, 191–195). The fit to the n = 2 cluster gives rotational constants consistent with a planar cluster of C 2v symmetry in which the second CO 2 molecule binds in the second quadrupolar binding pocket on the opposite side of the ring. The calculated total binding energy in pyrimidine-CO 2 is –13.7 kJ mol –1 , including corrections for basis set superposition error and zero-point energy, at the CCSD(T)/ 6-311++G(3df,2p) level, while that in pyrimidine-(CO 2 ) 2 is almost exactly double that size, indicating little interaction between the two CO 2 molecules in the two binding sites. The enthalpy, entropy, and free energy of binding are also calculated at 300 K within the harmonic oscillator/rigid-rotor model. This model is shown to lack quantitative accuracy when it is applied to the formation of weakly bound complexes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

AC Magnetometry Using Nano-ferrofluid Cladded Multimode Interferometric Fiber Optic Sensors for Power Grid Monitoring Applications

The AC magnetic field response of the superparamagnetic nano-ferrofluid is an interplay between the Neel and Brownian relaxation processes and is generally quantified via the susceptibility measurements at high frequencies. The high frequency limit is dictated by these relaxation times which need to be shorter than the time scale of the time varying magnetic field for the nano-ferrofluid to be considered in an equilibrium state at each time instant. Even though the high frequency response of ferrofluid has been extensively investigated for frequencies up to GHz range by non-optical methods, harnessing dynamic response by optical means for AC magnetic field sensing in fiber-optic-based sensors-field remains unexplored. Instead, the incorporation of nano-ferrofluid as sensing materials has been only limited to DC magnetic field sensing, often citing their long response time as a limiting factor to AC field sensing. This work reports the finding of high frequency (up to 15 kHz) AC magnetic field sensing capability of nanomagnetic fluid as the cladding material of a fiber-optic multimode interferometry (MMI) structure optimized for the fourth self-imaging spectral response. The key parameter enabling high frequency response is the short response time (<1 ms) achieved by optimizing both the sensing structure and nano-ferrofluid solution. Focus has been imparted on 60 Hz line-frequency profiles of various current/magnetic fields to test the efficacy of these sensors in metering and monitoring current and current-induced magnetic fields in the electrical power grid systems. The magnetic field sensitivity of 240 mV/Gauss per dBm of transmitted power was achieved for 60 Hz field applied via Helmholtz coil, whereas the 60 Hz AC current sensitivity of 2.83 mV/A was measured due to magnetic field induced by current in a straight conducting wire.

42 ENGINEERING↗

A multifrequency study of sub-parsec jets with the Event Horizon Telescope

Context. The 2017 observing campaign of the Event Horizon Telescope (EHT) delivered the first very long baseline interferometry (VLBI) images at the observing frequency of 230 GHz, leading to a number of unique studies on black holes and relativistic jets from active galactic nuclei (AGN). In total, eighteen sources were observed, including the main science targets, Sgr A* and M 87, and various calibrators. Sixteen sources were AGN.Aims. We investigated the morphology of the sixteen AGN in the EHT 2017 data set, focusing on the properties of the VLBI cores: size, flux density, and brightness temperature. We studied their dependence on the observing frequency in order to compare it with the Blandford-Königl (BK) jet model. In particular, we aimed to study the signatures of jet acceleration and magnetic energy conversion.Methods. We modeled the source structure of seven AGN in the EHT 2017 data set using linearly polarized circular Gaussian components (1749+096, 1055+018, BL Lac, J0132–1654, J0006–0623, CTA 102, and 3C 454.3) and collected results for the other nine AGN from dedicated EHT publications, complemented by lower frequency data in the 2–86 GHz range. Combining these data into a multifrequency EHT+ data set, we studied the dependences of the VLBI core component flux density, size, and brightness temperature on the frequency measured in the AGN host frame (and hence on the distance from the central black hole), characterizing them with power law fits. We compared the observations with the BK jet model and estimated the magnetic field strength dependence on the distance from the central black hole.Results. Our observations spanning event horizon to parsec scales indicate a deviation from the standard BK model, particularly in the decrease of the brightness temperature with the observing frequency. Only some of the discrepancies may be alleviated by tweaking the model parameters or the jet collimation profile. Either bulk acceleration of the jet material, energy transfer from the magnetic field to the particles, or both are required to explain the observations. For our sample, we estimate a general radial dependence of the Doppler factor δ ∝ r≤0.5. This interpretation is consistent with a magnetically accelerated sub-parsec jet. We also estimate a steep decrease of the magnetic field strength with radius B ∝ r−3, hinting at jet acceleration or efficient magnetic energy dissipation.Key words: techniques: interferometric / galaxies: active / galaxies: jets / galaxies: nuclei / quasars: general / quasars: supermassive black holes⋆⋆ Deceased.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗