Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAS METER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

F-15 digital electronic engine control system description

A digital electronic engine control (DEEC) was developed for use on the F100-PW-100 turbofan engine. This control system has full authority control, capable of moving all the controlled variables over their full ranges. The digital computational electronics and fault detection and accomodation logic maintains safe engine operation. A hydromechanical backup control (BUC) is an integral part of the fuel metering unit and provides gas generator control at a reduced performance level in the event of an electronics failure. The DEEC's features, hardware, and major logic diagrams are described.

Myers, L. P.↗

Quiescent Giant Molecular Cloud Cores in the Galactic Center

We have used the Long Wavelength Spectrometer (LWS) aboard the Infrared Space Observatory (ISO) to map the far-infrared continuum emission (45-175 micrometer) toward several massive Giant Molecular Cloud (GMC) cores located near the Galactic center. The observed far-infrared and submillimeter spectral energy distributions imply low temperatures (approx. 15 - 22 K) for the bulk of the dust in all the sources, consistent with external heating by the diffuse ISRF and suggest that these GMCs do not harbor high- mass star-formation sites, in spite of their large molecular mass. Observations of FIR atomic fine structure lines of C(sub II) and O(sub I) indicate an ISRF enhancement of approx. 10(exp 3) in the region. Through continuum radiative transfer modeling we show that this radiation field strength is in agreement with the observed FIR and submillimeter spectral energy distributions, assuming primarily external heating of the dust with only limited internal luminosity (approx. 2 x 10(exp 5) solar luminosity). Spectroscopic observations of millimeter-wave transitions of H2CO, CS, and C-34S carried out with the Caltech Submillimeter Observatory (CSO) and the Institut de Radio Astronomie Millimetrique (IRAM) 30-meter telescope indicate a gas temperature of approx. 80 K, significantly higher than the dust temperatures, and density of approx. 1 x 10(exp 5)/cc in GCM0.25 + 0.01, the brightest submillimeter source in the region. We suggest that shocks caused by cloud collisions in the turbulent interstellar medium in the Galactic center region are responsible for heating the molecular gas. This conclusion is supported by the presence of wide-spread emission from molecules such as SiO, SO, and CH3OH, which are considered good shock tracers. We also suggest that the GMCs studied here are representative of the "typical", pre-starforming cloud population in the Galactic center.

Lis, D. C.↗

Validation of a Computational Model for the SLS Core Stage Oxygen Tank Diffuser Concept and the Low Profile Diffuser - An Advanced Development Design for the SLS

The Low Profile Diffuser (LPD) project originated as an award from the Marshall Space Flight Center (MSFC) Advanced Development (ADO) office to the Main Propulsion Systems Branch (ER22). The task was created to develop and test an LPD concept that could produce comparable performance to a larger, traditionally designed, ullage gas diffuser while occupying a smaller volume envelope. Historically, ullage gas diffusers have been large, bulky devices that occupy a significant portion of the propellant tank, decreasing the tank volume available for propellant. Ullage pressurization of spacecraft propellant tanks is required to prevent boil-off of cryogenic propellants and to provide a positive pressure for propellant extraction. To achieve this, ullage gas diffusers must slow hot, high-pressure gas entering a propellant tank from supersonic speeds to only a few meters per second. Decreasing the incoming gas velocity is typically accomplished through expansion to larger areas within the diffuser which has traditionally led to large diffuser lengths. The Fluid Dynamics Branch (ER42) developed and applied advanced Computational Fluid Dynamics (CFD) analysis methods in order to mature the LPD design from and initial concept to an optimized test prototype and to provide extremely accurate pre-test predictions of diffuser performance. Additionally, the diffuser concept for the Core Stage of the Space Launch System (SLS) was analyzed in a short amount of time to guide test data collection efforts of the qualification of the device. CFD analysis of the SLS diffuser design provided new insights into the functioning of the device and was qualitatively validated against hot wire anemometry of the exterior flow field. Rigorous data analysis of the measurements was performed on static and dynamic pressure data, data from two microphones, accelerometers and hot wire anemometry with automated traverse. Feasibility of the LPD concept and validation of the computational model were demonstrated by the test data.

Brodnick, Jacob↗

Cryogenic Thermal Absorptance Measurements on Small-Diameter Stainless Steel Tubing

The Mid Infrared Instrument (MIRI) on the James Webb Space Telescope includes a mechanical cryocooler which cools its detectors to their 6 Kelvin operating temperature. The coolant gas flows through several meters of small-diameter stainless steel tubing, which is exposed to thermal radiation from its environment. Over much of its length this tubing is gold-plated to minimize the absorption of this radiant heat. In order to confirm that the cryocooler will meet MIRI's requirements, the thermal absorptance of this tubing was measured as a function of its environment temperature. We describe the measurement technique and present the results.

cryogenics↗

CO2 (dry ice) cleaning system

Tomco Equipment Company has participated in the dry ice (solid carbon dioxide, CO2) cleaning industry for over ten years as a pioneer in the manufacturer of high density, dry ice cleaning pellet production equipment. For over four years Tomco high density pelletizers have been available to the dry ice cleaning industry. Approximately one year ago Tomco introduced the DI-250, a new dry ice blast unit making Tomco a single source supplier for sublimable media, particle blast, cleaning systems. This new blast unit is an all pneumatic, single discharge hose device. It meters the insertion of 1/8 inch diameter (or smaller), high density, dry ice pellets into a high pressure, propellant gas stream. The dry ice and propellant streams are controlled and mixed from the blast cabinet. From there the mixture is transported to the nozzle where the pellets are accelerated to an appropriate blasting velocity. When directed to impact upon a target area, these dry ice pellets have sufficient energy to effectively remove most surface coatings through dry, abrasive contact. The meta-stable, dry ice pellets used for CO2 cleaning, while labeled 'high density,' are less dense than alternate, abrasive, particle blast media. In addition, after contacting the target surface, they return to their equilibrium condition: a superheated gas state. Most currently used grit blasting media are silicon dioxide based, which possess a sharp tetrahedral molecular structure. Silicon dioxide crystal structures will always produce smaller sharp-edged replicas of the original crystal upon fracture. Larger, softer dry ice pellets do not share the same sharp-edged crystalline structures as their non-sublimable counterparts when broken. In fact, upon contact with the target surface, dry ice pellets will plastically deform and break apart. As such, dry ice cleaning is less harmful to sensitive substrates, workers and the environment than chemical or abrasive cleaning systems. Dry ice cleaning system components include: a dry ice pellet supply, a non-reactive propellant gas source, a pellet and propellant metering device, and a media transport and acceleration hose and nozzle arrangement. Dry ice cleaning system operating parameters include: choice of propellant gas, its pressure and temperature, dry ice mass flow rate, dry ice pellet size and shape, and acceleration nozzle configuration. These parameters may be modified to fit different applications. The growth of the dry ice cleaning industry will depend upon timely data acquisition of the effects that independent changes in these parameters have on cleaning rates, with respect to different surface coating and substrate combinations. With this data, optimization of cleaning rates for particular applications will be possible. The analysis of the applicable range of modulation of these parameters, within system component mechanical constraints, has just begun.

Barnett, Donald M.↗

A Novel Dew Point Meter: Application to the Measurement of the Sulfuric Acid Dew Point for Combustion Flue Gas

Accurate knowledge of acid dew point is essential for industrial and applied combustion applications. Sulfur in the fuel or raw materials is converted to sulfur dioxide (SO2) during combustion, and a portion of the SO2 is oxidized to sulfur trioxide (SO3). The SO3 will react to form H2SO4 vapor when in the presence of water vapor. Even with just trace levels of H2SO4 vapor in the gas phase (1-10 ppm), the dew point can reach 100°C and higher. To avoid acid condensation and the resulting corrosion on heat recovery equipment, plant engineers must ensure that surface temperatures are above the acid dew point, but this decreases the efficiency of thermal energy recovery. Thus, there is a trade-off between minimizing equipment corrosion and maximizing thermal energy recovery, and the acid dew point is a key parameter for this optimization. Commercially available acid dew point meters use electric conductivity sensors. These sensors are known to greatly underestimate the dew point due to their low sensitivity. In addition, no validation testing has been reported for these units and they are often expensive. In this work, we analyze the theory of the sulfuric acid condensation and develop a novel dew point meter based on this analysis. The meter consists of a novel optical instrument that is designed to monitor the slightest appearance of condensation on a hydrophobic window surface as the surface temperature of the window is slowly decreased. In this way, an accurate measurement of the dew point is obtained under a wide range of concentrations. The basis of the instrument is that a collimated beam from a diode laser will generate forward scattered light when the beam encounters surface condensate, and a sophisticated array detector is used to sensitively monitor the onset of light scattering. The measurement procedures are established to rapidly find the acid dew point, while minimizing error. Further, to calibrate the dew point meter we developed a calibration system based on a liquid bubbler that can generate a stable gas flow with a known sulfuric acid dew point. Test results show that the dew point meter can accurately measure acid dew point over a wide range. For H2SO4 vapor concentrations as low as 6 ppm the acid dew point is measured with an error of only ~1°C. To demonstrate the versatility of this instrument, the dew point meter was adapted for use with a high-pressure flow cell to allow for measurements of the dew point of flue gas from pressurized oxy-fuel combustion in a 100 kWth pressurized reactor.

Cheng, Mao↗

GEER Status Update

History: The Glenn Extreme Environments Rig (GEER) first became operational in the early part of 2015. Since that time GEER has completed a number of scientific tests and has undergone improvements in the chemical delivery system and analytics following a year of operations experience. Recent Updates: In June 2016, the GEER process system was rebuilt to provide a more robust system, higher accuracy and new capabilities. New insulation was installed on the exterior of the pressure vessel and gas lines. The newly revamped GEER plumbing system can provide extremely precise custom gas mixtures using any gas desired by the investigator in any combination. GEER can heat the resulting mixture up to 500 deg C and 1500 psia. The 304 stainless steel vessel walls were polished to reduce corrosion rate and reduce unwanted chemical reactions. The process lines were replaced with high purity Sulfinert coated tubing. The GEER team added the ability to individually boost specialty gases to GEER thus allowing operators to make very precise changes to the gas chemistry inside of GEER during a test while at high temperature and pressure. High accuracy mass flow meters were added to further improve gas mixing accuracy and precision. An in-line, integrated Inficon MicroGC Fusion was added for real time gas analysis along with a high purity gas sampling system, providing fully automated, real time analysis of the gas chemistry inside of GEER in minutes. This complements a co-located mass spectrometer and both are used for regular monitoring of the vessel chemistry. All internal vessel components were replaced with polished 304SS equivalents. Hot vent down capability was increased. Finally, an automated liquid injection system was added and is rated for max vessel operating conditions of (1500 psia, 500 C). Recent Results and Publications: In May 2016, GEER completed a test that exposed high temperature electronics to Venus surface conditions for 21.5 days. This demonstrated the potential for operating robotic spacecraft in the Venus environment without the need for thermal or environmental protection. Results from this test were published in December 2016 and received national media attention. In April 2017 GEER implemented an 80 day test at Venus surface conditions to simulate chemical weathering of expected Venus minerals. This test supported a ROSES award to a team led by Prof. Ralph Harvey of Case Western Reserve University. The test concluded in July 2017 and nearly doubled previous operation record of 42 days at Venus surface conditions. Preliminary results of these and previous experiments were presented at the recent Venus Modeling Workshop. In June 2017, NASA TM2017-219437 "Chemical and Microstructural Changes in Metallic and Ceramic Materials Exposed to Venusian Surface Conditions" was published. This report provides an extensive and valuable resource detailing the behavior of a variety of engineering materials at Venus surface conditions. Community Involvement: An external science advisory panel has been formed.

Kremic, Tibor↗

Subsurface energy storage and transport for solar-powered geysers on Triton

The location of active geyser-like eruptions and related features close to the current subsolar latitude on Triton suggests a solar energy source for these phenomena. Solid-state greenhouse calculations have shown that sunlight can generate substantially elevated subsurface temperatures. A variety of models for the storage of solar energy in a subgreenhouse layer and for the supply of gas and energy to a geyser are examined. 'Leaky greenhouse' models with only vertical gas transport are inconsistent with the observed upper limit on geyser radius of about 1.5 km. However, lateral transport of energy by gas flow in a porous N2 layer with a block size on the order of a meter can supply the required amount of gas to a source region about 1 km in radius. The decline of gas output to steady state may occur over a period comparable with the inferred active geyser lifetime of 5 earth years. The required subsurface permeability may be maintained by thermal fracturing of the residual N2 polar cap. A lower limit on geyser source radius of about 50 to 100 m predicted by a theory of negatively buoyant jets is not readily attained.

Kirk, Randolph L.↗

A method for generating quantitative vapor-phase infrared spectra of solids: results for phenol, camphor, menthol, syringol, dicyclopentadiene and naphthalene

Here, a method is presented to generate quantitative vapor-phase infrared spectra from substances that naturally occur as solids with moderate volatility. The solid is gravimetrically dissolved into a solvent that has few infrared spectral features, typically CS 2 and CCl 4 separately. The solution is flowed at a constant rate from a linearly pumped syringe into a metered stream of nitrogen carrier gas regulated by a mass flow controller. The analyte/solvent mix is flash vaporized by volatilizing the solution across a heated stainless-steel surface as it emanates from the syringe tip. The N 2 gas-solution mixture is flowed into a long-path White cell thermostatted at a desired temperature, the long optical path compensating for the modest analyte mixing ratio. A composite spectrum is generated from typically ten or more 760-Torr pressure-broadened spectra over the 600 to 6500 cm -1 spectral range at 0.1 cm -1 spectral resolution. The solid analytes reported here using this novel technique include dicyclopentadiene, menthol, syringol, phenol, camphor, and naphthalene.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Gas exchange-wind speed relation measured with sulfur hexafluoride on a lake

Gas-exchange processes control the uptake and release of various gases in natural systems such as oceans, rivers, and lakes. Not much is known about the effect of wind speed on gas exchange in such systems. In the experiment described here, sulfur hexafluoride was dissolved in lake water, and the rate of escape of the gas with wind speed (at wind speeds up to 6 meters per second) was determined over a 1-month period. A sharp change in the wind speed dependence of the gas-exchange coefficient was found at wind speeds of about 2.4 meters per second, in agreement with the results of wind-tunnel studies. However the gas-exchange coefficients at wind speeds above 3 meters per second were smaller than those observed in wind tunnels and are in agreement with earlier lake and ocean results.

Wanninkhof, R.↗

Fabrication and test of digital output interface devices for gas turbine electronic controls

A program was conducted to develop an innovative digital output interface device, a digital effector with optical feedback of the fuel metering valve position, for future electronic controls for gas turbine engines. A digital effector (on-off solenoids driven directly by on-off signals from a digital electronic controller) with optical position feedback was fabricated, coupled with the fuel metering valve, and tested under simulated engine operating conditions. The testing indicated that a digital effector with optical position feedback is a suitable candidate, with proper development for future digital electronic gas turbine controls. The testing also identified several problem areas which would have to be overcome in a final production configuration.

Newirth, D. M.↗

Ventilation Heat Exchanger / Flow Meter for xPLSS

The flow meter / heat exchanger (FMHX) in the ventilation loop of the exploration EMU cools the ventilation gas and measures the ventilation flow rate. The heat exchanger transfers heat from the ventilation gas to the thermal control loop via a miniature shell-and-tube heat exchanger. The flow meters calculate the flow rate of gas through the ventilation loop based on the pressure drop across the heat exchanger core. Creare has delivered four design validation test (DVT) heat exchangers and five DVT flow meters to NASA JSC to support development of the exploration portable life support system (xPLSS). This paper describes the design and performance of the DVT units.The heat exchangers are designed to cool the ventilation gas to a specified temperature with low pressure losses under the most challenging operating conditions. The measured performance of the DVT heat exchangers agrees well with design models and meets all performance requirements. The flow meters use a MEMS thermal flow sensor to produce a signal that is proportional to a small bypass flow around the heat exchanger core. They are designed to achieve high measurement accuracy across the full range of xPLSS operating conditions. We calibrated the flow meters in a special-purpose flow facility that simulates operation in the xPLSS ventilation loop. Calibration testing shows that DVT flow meters produce digital output for vent loop mass flow that meets NASA’s accuracy requirements across the range of xPLSS operating conditions. This paper reviews the design of the heat exchangers and flow meters and presents data from the final flow meter calibration testing, heat exchanger performance validation, and initial ground testing in NASA’s xPLSS.

spacesuit↗

Ventilation Heat Exchanger / Flow Meter for xPLSS

The flow meter / heat exchanger (FMHX) in the ventilation loop of the exploration EMU cools the ventilation gas and measures the ventilation flow rate. The heat exchanger transfers heat from the ventilation gas to the thermal control loop via a miniature shell-and-tube heat exchanger. The flow meters calculate the flow rate of gas through the ventilation loop based on the pressure drop across the heat exchanger core. Creare has delivered four design validation test (DVT) heat exchangers and five DVT flow meters to NASA JSC to support development of the exploration portable life support system (xPLSS). This paper describes the design and performance of the DVT units.The heat exchangers are designed to cool the ventilation gas to a specified temperature with low pressure losses under the most challenging operating conditions. The measured performance of the DVT heat exchangers agrees well with design models and meets all performance requirements. The flow meters use a MEMS thermal flow sensor to produce a signal that is proportional to a small bypass flow around the heat exchanger core. They are designed to achieve high measurement accuracy across the full range of xPLSS operating conditions. We calibrated the flow meters in a special-purpose flow facility that simulates operation in the xPLSS ventilation loop. Calibration testing shows that DVT flow meters produce digital output for vent loop mass flow that meets NASA’s accuracy requirements across the range of xPLSS operating conditions. This paper reviews the design of the heat exchangers and flow meters and presents data from the final flow meter calibration testing, heat exchanger performance validation, and initial ground testing in NASA’s xPLSS.

spacesuit↗

Improved Gas Filling and Sealing of an HC-PCF

An improved packaging approach has been devised for filling a hollow-core photonic-crystal fiber (HC-PCF) with a gas, sealing the HC-PCF to retain the gas, and providing for optical connections and, optionally, a plumbing fitting for changing or augmenting the gas filling. Gas-filled HC-PCFs can be many meters long and have been found to be attractive as relatively compact, lightweight, rugged alternatives to conventional gas-filled glass cells for use as molecular-resonance frequency references for stabilization of lasers in some optical-metrology, lidar, optical-communication, and other advanced applications. Prior approaches to gas filling and sealing of HC-PCFs have involved, variously, omission of any attempt to connectorize the PCF, connectorization inside a vacuum chamber (an awkward and expensive process), or temporary exposure of one end of an HC-PCF to the atmosphere, potentially resulting in contamination of the gas filling. Prior approaches have also involved, variously, fusion splicing of HC-PCFs with other optical fibers or other termination techniques that give rise to Fresnel reflections of about 4 percent, which results in output intensity noise.

Poberezhskiy, Ilya↗

Image degradation in Langley 0.3-meter transonic cryogenic tunnel

The optical quality of gas in a cryogenic wind tunnel was determined by observing Sayce targets through different pathlengths of the medium. The data were used to determine the square wave response of the test gas. At conditions corresponding to 15 times ambient density, considerable decrease in response to higher spatial frequencies was noted even in the absence of flow. Under flow conditions, vibrations further degraded the response. The results are interpreted in terms of possible photogrammetric approaches to measure model deformation in large cryogenic facilities such as the National Transonic Facility.

Snow, W. L.↗