Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAS CHROMATOGRAPHY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Venus lower atmospheric composition - Analysis by gas chromatography

The first gas chromatographic analysis of the lower atmosphere of Venus is reported. Three atmospheric samples were analyzed. The third of these samples showed carbon dioxide (96.4 percent), molecular nitrogen (3.41 percent), water vapor (0.135 percent), molecular oxygen (69.3 ppm), argon (18.6 ppm), neon (4.31 ppm), and sulfur dioxide (186 ppm). The amounts of water vapor and sulfur dioxide detected are roughly compatible with the requirements of greenhouse models of the high surface temperature of Venus. The large positive gradient of sulfur dioxide, molecular oxygen, and water vapor from the cloud tops to their bottoms, as implied by Earth-based observations and these results, gives added support for the presence of major quantities of aqueous sulfuric acid in the clouds. A comparison of the inventory of inert gases found in the atmospheres of Venus, Earth, and Mars suggests that these components are due to outgassing from the planetary interiors.

Oyama, V. I.↗

Determination of methane in ambient air by multiplex gas chromatography

A multiplex gas chromatographic technique for the determination of methane in ambient air over extended periods is reported. A modest gas chromatograph which uses air as the carrier gas was modified by adding a silver oxide sample modulator for multiplex operation. The modulator selectively catalyzes the decomposition of methane in air. The resulting analytical system requires no consumables beyond power. A profile of the methane concentration in this laboratory was obtained for an 8-day period. During this period, methane concentration varied with an approximately daily period from a low of 1.53 + or - 0.60 ppm to a high of 4.63 + or - 0.59 ppm over the entire 8 days. Some of the measured concentrations are higher than those reported elsewhere indicating the presence of some local source or sources for methane. This work has demonstrated the utility of a relatively simple multiplex gas chromatograph for the analysis of environmental samples. The technique should be applicable to other trace components in air through use of other selective modulators.

Valentin, J. R.↗

Measuring Solvation Interactions of Deep Eutectic Solvents Formed by Metal Chlorides and an Imidazolium Salt by Inverse Gas Chromatography

Deep eutectic solvents (DESs) represent a class of solvents that offer a number of advantages including minimal toxicity, affordability, low vapor pressure, and simple, environmentally friendly preparation methods. They have found utility in areas, such as gas absorption, metal plating, and extractions. However, the relationship between their solvation properties and chemical composition remains poorly understood. In this study, a broad range of Type I DESs composed of metal chlorides and an imidazolium salt were prepared, employed as gas chromatographic stationary phases, and characterized using the Abraham solvation parameter model by inverse gas chromatography. The Abraham solvation parameter model allows for the study of DES solvation properties and the effects of varying structural components on system constants using a linear-free energy relationship. The DESs were investigated by systematically varying their composition, including the type of metal chloride and the molar ratio between the metal chloride and the imidazolium salt. The results show that hydrogen bond acidity, hydrogen bond basicity, and dipolarity/polarizability interactions are strongly influenced by the type of metal chloride within the DES and the ratio of metal chloride to imidazolium salt in the eutectic mixture. Furthermore, a column pretreatment procedure is presented that enables the effective coating of highly polar DESs onto open tubular capillary gas chromatography columns.

deep eutectic solvent↗

Development of a Gas Chromatography with High-Resolution Time-of-Flight Mass Spectrometry Methodology for BDNPA/F

Analysis of thermally labile compounds such as bis(2,2-dinitropropyl) acetal/formal (BDNPA/F), an energetic plasticizer, is usually performed via liquid chromatography (LC) as opposed to gas chromatography (GC) due to thermal decomposition in the inlet or the analytical column. While LC is a powerful technique, the analysis of volatile and semivolatile compounds is best suited to GC. Herein, a method was developed for a gas chromatograph coupled to high-resolution mass spectrometer (GC-HRMS), utilizing a programmable temperature vaporizer (PTV) inlet. A subset of the native compounds and several produced by the thermal decomposition of BDNPA/F in the inlet were evaluated by using multiple PTV inlet parameters to determine the optimal ramp rate and final temperature of the inlet (60 °C/min from 60 to 325 °C). The optimized GC-HRMS method nearly reduced all thermal decomposition, allowing for an excellent separation to be obtained. Furthermore, multiple ionization methods, including electron impact (EI), negative chemical ionization (NCI), and positive chemical ionization (PCI), were used to explore the many chemical differences between the BDNPA/F samples. A preliminary investigation of the benefits of using GC-HRMS to evaluate the chemical differences between unaged and aged BDNPA/F samples for unique insight was evaluated.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Gas chromatography: Possible application of advanced instrumentation developed for solar system exploration to space station cabin atmospheres

Gas chromatography (GC) technology was developed for flight experiments in solar system exploration. The GC is a powerful analytical technique with simple devices separating individual components from complex mixtures to make very sensitive quantitative and qualitative measurements. It monitors samples containing mixtures of fixed gases and volatile organic molecules. The GC was used on the Viking mission in support of life detection experiments and on the Pioneer Venus Large Probe to determine the composition of the venusian atmosphere. A flight GC is under development to study the progress and extent of STS astronaut denitrogenation prior to extravehicular activity. Advanced flight GC concepts and systems for future solar system exploration are also studied. Studies include miniature ionization detectors and associated control systems capable of detecting from ppb up to 100% concentration levels. Further miniaturization is investigated using photolithography and controlled chemical etching in silicon wafers. Novel concepts such as ion mobility drift spectroscopy and multiplex gas chromatography are also developed for future flight experiments. These powerful analytical concepts and associated hardware are ideal for the monitoring of cabin atmospheres containing potentially dangerous volatile compounds.

Carle, G. C.↗

Using Comprehensive Two-Dimensional Gas Chromatography to the Explore the Geochemistry of the Santa Barbara Oil Seeps

The development of comprehensive two-dimensional gas chromatography (GC x GC) has expanded the analytical window for studying complex mixtures like oil. Compared to traditional gas chromatography, this technology separates and resolves at least an order of magnitude more compounds, has a much larger signal to noise ratio, and sorts compounds based on their chemical class; hence, providing highly refined inventories of petroleum hydrocarbons in geochemical samples that was previously unattainable. In addition to the increased resolution afforded by GC x GC, the resulting chromatograms have been used to estimate the liquid vapor pressures, aqueous solubilities, octanol-water partition coefficients, and vaporization enthalpies of petroleum hydrocarbons. With these relationships, powerful and incisive analyses of phase-transfer processes affecting petroleum hydrocarbon mixtures in the environment are available. For example, GC x GC retention data has been used to quantitatively deconvolve the effects of phase transfer processes such as water washing and evaporation. In short, the positive attributes of GC x GC-analysis have led to a methodology that has revolutionized the analysis of petroleum hydrocarbons. Overall, this research has opened numerous fields of study on the biogeochemical "genetics" (referred to as petroleomics) of petroleum samples in both subsurface and surface environments. Furthermore, these new findings have already been applied to the behavior of oil at other seeps as well, for petroleum exploration and oil spill studies.

02 PETROLEUM↗

Hydrogen Analysis by Gas Chromatography–Mass Spectrometry

The detection of hydrogen in complex gas mixtures is essential for many applications. Conventional approaches such as gas chromatography (GC) with thermal conductivity detection (TCD) and residual gas analyzers (RGAs) face significant limitations: TCD exhibits poor response when helium is used as a carrier gas, whereas RGAs lack chromatographic separation, preventing reliable quantification of hydrogen because of interference from other species. Traditional GC methods rely on dual-column configurations with packed or molecular-sieve porous layer open tubular (PLOT) columns to separate hydrogen from O2, N2, CO, CO2, CH4, and other hydrocarbons, increasing system complexity and limiting compatibility with mass spectrometry (MS) detection. In this work, we developed and validated a robust GC–MS method capable of directly detecting and quantifying hydrogen using electron ionization (EI) without dopants, reagent gases, or ion–molecule reaction schemes. By integrating a modified EI source and a cryogenically cooled single capillary column configuration, we achieved baseline separation of hydrogen from all major permanent gases and hydrocarbons in a refinery gas mixture using helium as the carrier gas. The method demonstrated excellent linearity, high sensitivity, and exceptional reproducibility. Adjustable sample-loop volumes and split ratios enabled optimization of peak shape and signal-to-noise performance for trace-level and percent-level hydrogen concentrations. Beyond hydrogen quantitation, the method provides simultaneous compositional profiling of other gases in a mixture in a single run, making it valuable for a wide range of tasks.

Lobodin, Vlad [ORNL]↗

Capillary gas chromatography with two new moderately high temperature phases.

Gas chromatography test results are presented for two new moderately high-temperature phases of Dexsil 400-GC with free hydroxyl end groups (uncapped) and with end groups covered by trimethyl silyl groups (capped). The two Dexsil 400-GC phases were tested for their ability to resolve N-TFA-DL-(+)-2-butyl esters and n-butyl esters, as well as fatty acid methyl esters and hydrocarbon standards. Generally the more polar uncapped phase was superior to the capped phase in all separation comparisons, except for the hydrocarbons.

Pollock, G. E.↗

Physicochemical Gas–Solid Sorption Properties of Geologic Materials Using Inverse Gas Chromatography

The goal of this study was to determine the physicochemical properties of a variety of geologic materials using inverse gas chromatography (IGC) by varying probe gas selection, temperature, carrier gas flow rate, and humidity. This is accomplished by measuring the level of interaction between the materials of interest and known probe gases. Identifying a material’s physicochemical characteristics can help provide a better understanding of the transport of gaseous compounds in different geologic materials or between different geological layers under various conditions. Our research in this study focused on measuring the enthalpy (heat) of adsorption, Henry’s constant, and diffusion coefficients of a suite of geologic materials, including two soil types (sandy clay-loam and loam), quartz sand, salt, and bentonite clay, with various particle sizes. The reproducibility of IGC measurements for geologic materials, which are inherently heterogeneous, was also assessed in comparison to the reproducibility for more homogeneous synthetic materials. This involved determining the variability of physicochemical measurements obtained from different IGC approaches, instruments, and researchers. For the investigated IGC-determined parameters, the need for standardization became apparent, including the need for application-relevant reference materials. The inherent physical and chemical heterogeneities of soil and many geologic materials can make the prediction of sorption properties difficult. Characterizing the properties of individual organic and inorganic components can help elucidate the primary factors influencing sorption interactions in more complex mixtures. This research examined the capabilities and potential challenges of characterizing the gas sorption properties of geologic materials using IGC.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Tile-Based Fisher-Ratio Software for Improved Feature Selection Analysis of Comprehensive Two-Dimensional Gas Chromatography Time-of-Flight Mass Spectrometry Data

Two-dimensional (2D) gas chromatography coupled with time-of-flight mass spectrometry (GC × GC – TOFMS) is a highly capable instrumental platform that produces complex and information-rich multi-dimensional chemical data. The complex data can be overwhelming, especially when many samples (of various sample classes) are analyzed with multiple injections for each sample. Thus, the data must be analyzed in such a way to extract the most meaningful information. The pixel-based and peak table-based algorithmic use of Fisher ratios has been used successfully in the past to reduce the multi-dimensional data down to those chemical compounds that are changing between classes relative to those that are not (i.e., chemical feature selection). We report on the initial development of a computationally fast novel tile-based Fisher-ratio software that addresses challenges due to 2D retention time misalignment without explicitly aligning the data, which is a problem for both pixel-based and peak table- based methods. Concurrently, the tile-based Fisher-ratio software maximizes the sensitivity contrast of true positives against a background of potential false positives and noise. To study this software, eight compounds, plus one internal standard, were spiked into diesel at various concentrations. The tile-based F-ratio software was able to discover all spiked analytes, within the complex diesel sample matrix with thousands of potential false positives, in each possible concentration comparison, even at the lowest absolute spiked analyte concentration ratio of 1.06.

chemometrics↗

Investigating Solvent Purity Utilizing Comprehensive Gas Chromatography: A Study of Acetones

Broad spectrum chemical analysis of trace level components is a continuing challenge for any analytical chemist. This challenge is further confounded when chemical impurities may be present in common organic solvents or when chemical artifacts may be formed, produced and introduced during an analytical procedure. Minimizing and understanding these chemical artifacts, is critical for trace level detection and is crucial for unambiguous analytical results. Comprehensive gas chromatography is an excellent analytical tool to help address these complex mixture challenges. This work examines the impurities present in various acetone sources utilizing comprehensive gas chromatography. This work highlights the extreme variability possible in solvent sources and hence the importance of understanding the impurities that may confound an analytical method or result.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗