Resolution of racemic amino acids by gas chromatography.
Thermal stability to racemization and resolution of several racemic amino acid diastereomeric derivatives by gas chromatography
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Thermal stability to racemization and resolution of several racemic amino acid diastereomeric derivatives by gas chromatography
Complex organic compounds analysis by fast- electrical-scanning high resolution mass spectrometry and gas chromatography
Hot-filament detector analyzes chemically active materials used in gas chromatography. The detector reacts chemically with the effluent vapors in the gas chromatographic apparatus to change the electrical resistance of the filament as a function of the affluent composition. Due to the changes produced by chemical action on the filament, the system is often calibrated.
A new highly crosslinked silicone polymer particle for gas chromatography application and a process for synthesizing such copolymer are described. The new copolymer comprises vinyltriethoxysilane and octadecyltrichlorosilane. The copolymer has a high degree of crosslinking and a cool balance of polar to nonpolar sites in the porous silicon polymer assuring fast separation of compounds of variable polarity.
Miniaturized chemical instrumentation is needed for in situ measurements in planetary exploration and other spaceflight applications where factors such as reduction in payload requirements and enhanced robustness are important. In response to this need, we are 'continuing to develop miniaturized GC/MS instrumentation which combines chemical separations by gas chromatography (GC) with mass spectrometry (MS) to provide positive identification of chemical compounds in complex mixtures of gases, such as those found in the International Space Station's cabin atmosphere. Our design approach utilizes micro gas chromatography components coupled with either a miniature quadrupole mass spectrometer array (QMSA) or compact, high-resolution Paul ion trap.
Xenon and krypton as carrier gases in a highly sensitive ionization system, for detection of permanent gases and organic vapors, by gas chromatography
The Sample Analysis at Mars (SAM) instrument onboard the Curiosity rover, is specifically designed for in situ molecular and isotopic analyses of martian surface materials and atmosphere. It contributes to the Mars Science Laboratory (MSL) missions primary scientific goal to characterize the potential past, present or future habitability of Mars. In all of the analyses of solid samples delivered to SAM so far, chlorinated organic compounds have been detected above instrument background levels and identified by gas chromatography coupled to mass spectrometry (GC-MS) (Freissinet et al., 2015; Glavin et al., 2013). While some of these may originate from reactions between oxychlorines and terrestrial organic carbon present in the instrument background (Glavin et al., 2013), others have been demonstrated to originate from indigenous organic carbon present in samples (Freissinet et al., 2015). We present here laboratory calibrations that focused on the analyses performed with the MXT-CLP GC column (SAM GC-5 channel) used for nearly all of the GC-MS analyses of the martian soil samples carried out with SAM to date. Complementary to the mass spectrometric data, gas chromatography allows us to separate and identify the species analyzable in a nominal SAM-GC run time of about 21 min. To characterize the analytical capabilities of this channel within the SAM Flight Model (FM) operating conditions on Mars, and their implications on the detection of organic matter, it is required to perform laboratory experimental tests and calibrations on spare model components. This work assesses the SAM flight GC-5 column efficiency, confirms the identification of the molecules based on their retention time, and enables a better understanding of the behavior of the SAM injection trap (IT) and its release of organic molecules. This work will enable further optimization of the SAM-GC runs for additional samples to be analyzed during the MSL mission.
The development of efficient and selective olefin separation technologies is a critical challenge within the chemical industry given the high energy demands of conventional cryogenic distillation methods. To address this, the study explores the effectiveness of polymeric ionic liquid (PIL) stationary phases in gas chromatography (GC) that incorporate both silver(I) ([Ag + ]) and copper(II) ([Cu 2+ ]) ions for enhanced olefin separation via π-complexation interactions. Further, the effects of both non-crosslinked and crosslinked PIL stationary phases containing varying ratios of [Ag⁺] and [Cu²⁺] ions were systematically investigated to evaluate their impact on the separation of olefins from paraffins and structurally similar olefins. Retention measurements using a broad range of olefinic probes revealed that [Ag⁺] ions provided stronger and more consistent π-complexation in PIL-based stationary phases, while [Cu²⁺] ions preferentially enhance olefin retention in crosslinked systems. Furthermore, thermal stability studies showed that [Ag + ]-containing PIL stationary phases maintain stable olefin separation efficiency over prolonged exposure under elevated temperatures, while crosslinked PIL stationary phases containing [Cu 2+ ] ions exhibited stronger retention due to increased surface adsorption. These findings provide insight into the tunability of metal–olefin interactions using PIL-based stationary phases and suggest design strategies for achieving thermally stable and highly selective chromatographic separations of unsaturated hydrocarbons.
Gas liquid chromatography resolution of racemic hydroxy and beta-mercapto-amino acids involving suitable derivation of functional group
High sensitivity optical resolution of amine diastereoisomers by gas liquid chromatography
Reagent menthyl chloroformate use in optical analysis of asymmetric amino and hydroxyl compounds by gas chromatography
Gas chromatography and mass spectrometry applied to porphyrin microanalysis, studying homologous porphyrin series in ancient sediments and oils
Results are presented from a study in which a continuously changed gaseous sample was monitored by multiplex gas chromatography (MGC), using the exponential dilution (ED) technique of Ritter and Adams (1976) to change the composition and concentration of a gaseous mixture in such a way as to imitate changes in the atmospheric gases sampled by a descending aircraft. A calibration of the MGC system was performed with four different rates of sample dilution, and the errors resulting from various degrees of change in the sample concentration were determined.
Cold trap concentrates oxygen and argon to determine trace amounts /as low as 0.1 ppm/ in helium by gas chromatography.
Soil moisture content was determined by extracting soil with methanol and subsequently analyzing the extract for water by gas chromatography. With air-dried mineral soils, this method gave slightly higher moisture content values than those obtained by the oven-dry method. Moisture content was determined quantitatively in soils to which various amounts of water had been added. The complete procedure, including extraction and analysis, requires less than one hour and gives results that closely compare to the oven-dry method.
The elution behavior of low molecular weight probes on inverse gas chromatography (IGC) columns is simulated using a computer. The IGC model is based on a polymer stationary phase of uniform thickness with a nonnegligible resitance to probe penetration. Three characteristic numbers are found to determine the whole process: Z(p) characterizing the distribution of the probe between phases, Z(f) describing the diffusion in the polymer phase, and Z(g) related to diffusion in the gaseous phase. For situations when Z(p)/Z(f) is less than 2, the standard evaluation procedures are virtually useless. The actual behavior of such systems is described.
Life detection for space missions based on detecting optical asymmetry in biogenic molecules by gas chromatography involving diastereomeric esters synthesis
Life detection for space missions based on detecting optical asymmetry in biogenic molecules by gas chromatography involving diastereomeric esters synthesis