Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAS ANALYZER”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Mars Phoenix Scout Thermal Evolved Gas Analyzer (TEGA) Database: Thermal Database Development and Analysis

The Mars Phoenix Scout Lander mission in 2008 examined the history of water, searched for organics, and evaluated the potential for past/present microbial habitability in a martian arctic ice-rich soil [1]. The Thermal Evolved Gas Analyzer (TEGA) instrument measured the isotopic composition of atmospheric CO2 and detected volatile bearing mineralogy (perchlorate, carbonate, hydrated mineral phases) in the martian soil [2-7]. The TEGA data are archived at the Planetary Data System (PDS) Geosciences Node but are reported in forms that require further processing to be of use to the non-TEGA expert. The soil and blank TEGA thermal data are reported as duty cycle and must be converted to differential power (mW) to allow for enthalpy calculations of exothermic/endothermic transitions. The exothermic/endothermic temperatures are also used to determine what phases (inorganic/organic) are present in the sample. The objectives of this work are to: 1) Describe how interpretable thermal data can be created from TEGA data sets on the PDS and 2) Provide additional thermal data interpretation of two Phoenix soils (Baby Bear, Wicked Witch) and include interpretations from three unreported soils (Rosy Red 1, 2, and Burning Coals).

Sutter, B.↗

In-Situ Reaction Monitoring for Lunar Applications Utilizing a Single Quadrupole Residual Gas Analyzer

With a revived focus to create a permeant presence on the moon and in preparation for future Mars exploration, it is imperative that all re-sources are utilized to their fullest potential. In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable independent operation of missions while minimally relying on the complex supply chain created between the Earth, moon and Mars. One of the most critical resources that have been identified for ISRU is the creation of liquid oxygen (O2) for not only breathable air, but also for rocket fuel. On the moon and potentially Mars, one of the most O2 rich resources is in the presence of regolith. Although there are numerous minerals within regolith and various processes to extract O2, this is not the scope of this paper. Since the O2 extraction method can vary, a critical standardized analytical method is needed to verify O2 (or oxygenated precursor compounds) for extraction efficiency and purity. Our group utilizes a modified consumer off-the-shelf (COTS), Residual Gas Analyzer (RGA) Single Quadrupole Mass Spectrometer (QMS). Due to the current field mission requirements, the gas analysis module will need to rely only on mass-to-charge ratios (m/z) and peak intensities to differentiate and quantitate targeted gas-phase reactants or products, i.e. carbon monoxide (CO), carbon dioxide (CO2), methane (CH4) and hydrogen (H2). However, due to solar wind implanted volatiles and various other compounds present in lunar regolith, such as nitrogen (N2), helium (He), and deuterium (D2), deconvolution and quantification of isobaric compounds becomes quite difficult. Specifically, the presence of N2 makes quantification of CO, an oxygenated precursor, difficult due to both compounds having a peak at m/z 28. Approaches to differentiate isobaric components: Initially, the solution to overcome isobaric overlap was to use isotopic ratios, particularly be-tween carbon-13 and nitrogen-15. Although limited literature discuss isotopic composition and attempt to quantify the ratios, variation is particularly high and limited to a few lunar regolith samples. The following were identified as potential approaches to quantify isobaric species, N2 and CO, using our RGA. Threshold Ionization. CO and N2 both have peaks at m/z 28, but only N2 is capable of producing a peak at m/z 7. While a N2 peak at m/z 7 is generally rare, instrument parameters can be optimized in order to maximize the peak intensity. Typically a standard ionization energy of 70 eV is used to monitor a batch process and would produce reliable results for a majority of the reactants or products that we are interested in quantifying. However, to analyze the rare molecular fragment of N2 (N2+ at m/z 7), a different ionization energy may be beneficial. Threshold Ionization Mass Spectrometry (TIMS) will be explored to optimize the N2+ peak at m/z 7 by varying parameters such as ionization energy and pressure. Therefore, a quantitative value at m/z 7 will be used to determine the product gas concentration of N2, which will be subtracted from the total concentration determined at m/z 28 enabling us to approximate the amount of CO. Secondary Detector (infrared gas detector, IR). Another approach to quantitate and differentiate be-tween isobaric components is to leverage alternative modes of detection. Unlike mass spectrometry, which generally uses a separation step prior to analysis (i.e. gas chromatography), IR produces energy that is specifically absorbed depending on the bond and configuration of the molecule. This technique could be leveraged since it is generally only active on non-symmetric molecules, i.e. CO. Utilizing concentrations of CO determined from another detector could help correct concentrations of CO obtained from the QMS. However, the inclusion of another detector adds additional mission requirements, such as power, software changes and avionics updates that add additional cost and schedule requirements.

mass spectrometry↗

Phoenix Lander's Thermal Evolved Gas Analyzer: Differential Scanning Calorimeter and Mass Spectrometer Database Development

The Mars Scout Phoenix lander will land in the north polar region of Mars in May, 2008. One objective of the Phoenix lander is to search for evidence of past life in the form of molecular organics that may be preserved in the subsurface soil. The Thermal Evolved Gas Analyzer (TEGA) was developed to detect these organics by coupling a simultaneous differential thermal analyzer (SDTA) with a mass spectrometer. Martian soil will be heated to approx.1000 C and potential organic decomposition products such as CO2, CH4 etc. will be examined for with the MS. TEGA s SDTA will also assess the presence of endothermic and exothermic reactions that are characteristic of soil organics and minerals as the soil is heated. The MS in addition to detecting organic decompositon products, will also assess the levels of soil inorganic volatiles such as H2O, SO2, and CO2. Organic detection has a high priority for this mission; however, TEGA has the ability to provide valuable insight into the mineralogical composition of the soil. The overall goal of this work is to develop a TEGA database of minerals that will serve as a reference for the interpretation of Phoenix-TEGA. Previous databases for the ill-fated Mars Polar Lander (MPL)-TEGA instrument only went to 725 C. Furthermore, the MPL-TEGA could only detect CO2 and H2O while the Phoenix-TEGA MS can examine up to 144 atomic mass units. The higher temperature Phoenix-TEGA SDTA coupled with the more capable MS indicates that a higher temperature database is required for TEGA interpretation. The overall goal of this work is to develop a differential scanning calorimeter (DSC) database of minerals along with corresponding MS data of evolved gases that can used to interpret TEGA data during and after mission operations. While SDTA and DSC measurement techniques are slightly different (SDTA does not use a reference pan), the results are fundamentally similar and thus DSC is a useful technique in providing comparative data for the TEGA database. The objectives of this work is to conduct DSC and MS analysis up to 1000 C of select minerals that may be found in the martian soil.

Sutter, B.↗

In-Situ Reaction Monitoring for Lunar Applications Utilizing a Single Quadrupole Residual Gas Analyzer

With a revived focus to create a permanent presence on the moon and in preparation for future Mars exploration, it is imperative that all resources are utilized to their fullest potential.[1] In-Situ Resource Utilization (ISRU) will be critical for future mission success as it would enable independent operation of missions while minimally relying on the complex supply chain created between the Earth, moon and Mars. One of the most critical resources that have been identified for ISRU is the creation of liquid oxygen(LO2) for not only breathable air, but also for rocket propellant. On the moon and potentially Mars, one of the most O2 rich resources is in the presence of regolith.[2],[3] Although there are numerous minerals within regolith and various processes to extract O2,this is not the scope of this paper. Since the O2 extraction method can vary, a critical standardized analytical method is needed to verify O2(or oxygenated precursor compounds) for extraction efficiency and purity. Our group utilizes a modified consumer off-the-shelf (COTS), Residual Gas Analyzer (RGA) Single Quadrupole Mass Spectrometer (QMS). Due to the current field mission requirements, the gas analysis module will need to rely only on mass-to-charge ratios (m/z) and peak intensities to differentiate and quantitate targeted gas-phase reactants or products, i.e. carbon monoxide(CO), carbon dioxide (CO2), methane (CH4) and hydrogen (H2). However, due to solar wind implanted volatiles and various other compounds present in lunar regolith, such as nitrogen (N2), helium (He), and deuterium (D2), deconvolution and quantification of isobaric compounds becomes quite difficult. Specifically, the presence of N2 makes quantification of CO, an oxygenated precursor, difficult due to both compounds having a peak at m/z 28.

Mass Spectrometry↗

Mineralogical and Geochemical Trends of the Murray Mudstones, Gale Crater: A Combined Sample Analysis at Mars-Evolved Gas Analyzer and Chemistry and Mineralogy Instrument Assessment

The Murray formation is predominantly composed of lacustrine mudstone that forms the basal layer of Aeolis Mons (informally Mt. Sharp) in Gale Crater, Mars. The Murray formation has distinct iron and sulfur mineralogical variation within its stratigraphy detectable by the Chemistry Mineralogy (Che-Min) instrument consisting of magnetite/hematite in the lower Murray and higher hematite, CaSO4, and smectite content in the upper Murray. The objectives of this work were to evaluate the Sample Analysis at Mars Evolved Gas Analyzer (SAM-EGA) data to 1) Determine what SAM-EGA-detectable phases correlate or do not correlate with the Murray mineralogical composition detected by CheMin and 2) Utilize CheMin/SAM results to propose possible formation scenarios for the observed Murray mudstone mineralogy.

Sutter, B.↗

Low-Power Architecture for an Optical Life Gas Analyzer

Analog and digital electronic control architecture has been combined with an operating methodology for an optical trace gas sensor platform that allows very low power consumption while providing four independent gas measurements in essentially real time, as well as a user interface and digital data storage and output. The implemented design eliminates the cross-talk between the measurement channels while maximizing the sensitivity, selectivity, and dynamic range for each measured gas. The combination provides for battery operation on a simple camcorder battery for as long as eight hours. The custom, compact, rugged, self-contained design specifically targets applications of optical major constituent and trace gas detection for multiple gases using multiple lasers and photodetectors in an integrated package.

Pilgrim, Jeffrey↗

Carrier suppression device for a heterodyne gas analyzer

Analyzer operates with broadband light from blackbody infrared source. Light is passed sequentially through two gas-filled chambers to suitable infrared detector while pressures in gas-filled chambers are modulated in sinusoidal manner. Because pressure of infrared-absorbing gases in chambers is modulated, amount of light absorbed by gases is also modulated.

Mcclatchie, E. A.↗

Regolith Evolved Gas Analyzer (REGA)

The instrument consists of five subsystems: (1) a programmable furnace which can be loaded with samples of regolith, (2) a mass spectrometer which detects and measures atmospheric gases or gases evolved during heating, (3) a tank of pressurized gas which can be introduced to the regolith material while detecting and measuring volatile reaction products, (4) a mechanism for dumping the regolith sample and repeating the experiment on a fresh sample, and (5) a data system which controls and monitors the furnace, gas system, and mass spectrometer.

Allen, Carlton C.↗

Further development and testing of the metabolic gas analyzer

Continued development of a metabolic monitor utilizing a mass spectrometer and digital computer to perform measurements and data reduction, is reported. The device prints-out breath-by-breath values for 02 consumption, C02 production, minute volume and tidal volume. The flow is measured by introduction of a tracer gas to the expired gas stream. Design modifications to reduce pressure drop in the flow splitter to one inch of water at 600 liters/min flow and to extend the range of linear flow measurement to 1000 liters/min are discussed.

Source record↗

Possible Calcite and Magnesium Perchlorate Interaction in the Mars Phoenix Thermal and Evolved Gas Analyzer (TEGA)

The Mars Phoenix Lander's TEGA instrument detected a calcium carbonate phase decomposing at high temperatures (approx.700 C) from the Wicked Witch soil sample [1]. TEGA also detected a lower temperature CO2 release between 400 C and 680 C [1]. Possible explanations given for this lower temperature CO2 release include thermal decomposition of Mg or Fe carbonates, a zeolitictype desorption reaction, or combustion of organic compounds in the soil [2]. The detection of 0.6 wt % soluble perchlorate by the Wet Chemistry Laboratory (WCL) on Phoenix [3] has implications for the possibility of organic molecules in the soil. Ming et al. [4] demonstrated that perchlorates could have oxidized organic compounds to CO2 in TEGA, preventing detection of their characteristic mass fragments. Here, we propose that a perchlorate salt and calcium carbonate present in martian soil reacted to produce the 400 C - 680 C TEGA CO2 release. The parent salts of the perchlorate on Mars are unknown, but geochemical models using WCL data support the possible dominance of Mg-perchlorate salts [5]. Mg(ClO4)2 6H2O is the stable phase at ambient martian conditions [6], and breaks down at lower temperatures than carbonates giving off Cl2 and HCl gas [7,8]. Devlin and Herley [7] report two exotherms at 410-478 C and 473-533 C which correspond to the decomposition of Mg(ClO4)2.

Cannon, K. M.↗

Directional molecular flow analysis and leak detection with a rotatable gas analyzer in a large space simulation chamber

A system was developed and applied at the NASA Manned Spacecraft Center for measuring and analyzing directional molecular flows in a large thermal vacuum chamber in order to verify molecular environment and identify characteristic and abnormal test article and chamber conditions. The system is described, and some results obtained in over 1200 hours of operation are given.

Ehlers, H. K. F.↗

Characteristics and performance study of mass spectrometer residual gas analyzers

Types of instruments studied were magnetic sector, omegatron, quadrupole, and monopole. Experimental results obtained included absolute sensitivity to argon, relative sensitivity to ten gases (hydrogen, helium, neon, nitrogen, carbon monoxide, oxygen, argon, carbon dioxide, krypton, and xenon), and cracking patterns for these gases.

Hultzman, W. W.↗

Fluidic-oscillator gas analyzer

Fluidic oscillator identifies hazardous single, and multicomponent gases. Since oscillator has no moving parts, it is highly reliable.

Faber, E. A.↗

Exploration of the Moon with Remote Sensing, Ground-Penetrating Radar, and the Regolith-Evolved Gas Analyzer (REGA)

There are two important reasons to explore the Moon. First, we would like to know more about the Moon itself: its history, its geology, its chemistry, and its diversity. Second, we would like to apply this knowledge to a useful purpose. namely finding and using lunar resources. As a result of the recent Clementine and Lunar Prospector missions, we now have global data on the regional surface mineralogy of the Moon, and we have good reason to believe that water exists in the lunar polar regions. However, there is still very little information about the subsurface. If we wish to go to the lunar polar regions to extract water, or if we wish to go anywhere else on the Moon and extract (or learn) anything at all, we need information in three dimensions an understanding of what lies below the surface, both shallow and deep. The terrestrial mining industry provides an example of the logical steps that lead to an understanding of where resources are located and their economic significance. Surface maps are examined to determine likely locations for detailed study. Geochemical soil sample surveys, using broad or narrow grid patterns, are then used to gather additional data. Next, a detailed surface map is developed for a selected area, along with an interpretation of the subsurface structure that would give rise to the observed features. After that, further sampling and geophysical exploration are used to validate and refine the original interpretation, as well as to make further exploration/ mining decisions. Integrating remotely sensed, geophysical, and sample datasets gives the maximum likelihood of a correct interpretation of the subsurface geology and surface morphology. Apollo-era geophysical and automated sampling experiments sought to look beyond the upper few microns of the lunar surface. These experiments, including ground-penetrating radar and spectrometry, proved the usefulness of these methods for determining the best sites for lunar bases and lunar mining operations.

Cooper, B. L.↗