Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “GAMMA SPECTROSCOPY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Digital pulse deconvolution with adaptive shaping for real-time high-resolution high-throughput gamma spectroscopy

A high-resolution high-throughput real-time adaptive digital pulse processing system is developed for high count rate gamma-ray spectroscopy applications. The adaptive digital pulse processing algorithms are implemented on a reconfigurable FPGA and include a pulse deconvolver, adaptive shaping filter, timing filter, baseline restorer, and pile-up rejecter. Digital pulse deconvolution is implemented to reconstruct the original detector signal from the preamplifier signal, which reduces the resolution deterioration due to pulse pile-up. The deconvoluted signal is shaped with a trapezoid filter and the shaping parameter is selected adaptively based on the time separation between successive input pulses. Experimental measurements are performed with a 137Cs source under varying count-rate conditions and using germanium detectors equipped with resistive feedback and transistor reset preamplifiers (TRP). The results herein demonstrate that when using a TRP, adaptive digital signal processing allows handling 106 counts/s. In addition, the implementation of a deconvolution approach limits resolution deterioration for throughput rates that are 4 to 10 times better than achievable in typical digital and analog gamma-ray spectroscopy systems.

47 OTHER INSTRUMENTATION↗

Gamma Spectroscopy Detector Candidates and Radioisotope Identification Algorithms for Use in National Security Applications

In 2006, the United States Congress mandated for the Department of Homeland Security (DHS) to screen all cargo containers to protect against terrorist acts and ensure the safety and security of the nation. Containers are screened by gamma and neutron detectors to ensure threat material is not smuggled into the country. However, because commerce is radioactive, detecting the presence of radioactive materials is not sufficient in ensuring the safety and security of the nation. Radioactive materials must also be identified in real time, thus distinguishing threat sources (Uranium-235 and Plutonium-230) from non-threat sources (kitty litter, pot ash, medical isotopes). Screening cargo containers can be considered a two-step process (1) alerting to the presence of radioactive material when gamma counts exceed a threshold setting, and (2) once alerted, identifying the type of radioactive material, which is done by collecting a gamma spectra and analyzing it with an analysis tool/algorithm. For this reason, it is important to evaluate not only emerging technology in neutron and gamma detection, but also investigate new advances in algorithm development for radioisotope identification (RIID). New candidates in detection and on-board algorithm analysis might offer opportunities to make the scanning, detection, and identification process more efficient while still ensuring the health and safety of the public. This research will investigate emerging technology in radiation detection focused on gamma spectroscopy capabilities and RIID algorithms for DHS applications.

61 RADIATION PROTECTION AND DOSIMETRY↗

{beta}- and {gamma}-spectroscopy study of {sup 119}Pd and {sup 119}Ag

Neutron-rich Pd-119 nuclei were produced in fission of natural uranium, induced by 25-MeV protons. Fission fragments swiftly extracted with the Ion Guide Isotope Separation On-Line method were mass separated using a dipole magnet and a Penning trap, providing mono-isotopic samples of Pd-119. Their beta(-) decay was measured with gamma gamma- and beta gamma-spectroscopy methods using low-energy germanium detectors and a thin plastic scintillator. Two distinct nuclear-level structures were observed in Ag-119, based on the 1/2(-) and 7/2(+) isomers reported previously. The beta(-)decay work was complemented by a prompt-gamma study of levels in Ag-119 populated in spontaneous fission of (252)cf, performed using the Gammasphere array of germanium detectors. Contrary to previous suggestions, our data show that the 1/2(-) isomer is located below the 7/2(+) isomer and is proposed as a new ground state of Ag-119 with the 7/2(+) isomer excitation energy determined to be 33.4 keV. Our data indicate that there are two beta unstable isomers in Pd-119, a proposed ground state of Pd-119 with tentative spin 1/2(-) or 3/2(+) and a half-life of 0.88 s and the other one about 350 keV above, having spin (11/2(-)) and a half-life of 0.85 s. The higher-energy isomer probably decays to the 1/2(-) or 3/2(+) ground state via a gamma cascade comprising 18.7-219.8-X-keV transitions. The unobserved isomeric transition with energy X approximate to 100 keV probably has an E3 multipolarity. Its hindrance factor is significantly lower than for analogous E3 isomeric transitions in lighter Pd isotopes, suggesting an oblate deformation of levels in Pd-119. Oblate configurations in Ag-119 are discussed also.

Kurpeta, J↗

Enrichment Meter Dataset from High-Resolution Gamma Spectroscopy Measurements of U3O8 Enrichment Standards and UF6 Cylinder Wall Equivalents

The Enrichment Meter Principle (EMP) is the basis for a commonly used standard test method for the non-destructive assay of 235 U enrichment in bulk compounds [1]. The technique involves determining the net count rate in the direct 186 keV peak using medium or high energy gamma-ray spectrometry in a fixed geometry. With suitable correction for wall attenuation, compound type, rate loss (live time), and peaked background (if significant), the atom fraction of 235 U may be obtained from the counting rate from a linear relationship through the origin. The widespread use of this method for field verification of enrichment [2,3] together with the fact that the response function rests on fundamental physics considerations (i.e., is not represented by a convenient but arbitrary form) makes it an interesting example of uncertainty quantification, one in which one can expect a valid measurement model can be applied. When applied using NaI(Tl) and region of interest analysis, the technique is susceptible to both interference error and bias [2-4]. When implemented using high-resolution gamma-ray spectroscopy, the spectrum interpretation is considerable simplified and more robust [5]. However, a practical challenge to studying the uncertainty budget of the EMP method (for example, to test linearity, extract wall corrections and so forth using modern methods) is the availability of quality experimental data that can be referenced and shared. To fill this gap, the research team undertook an experimental campaign [6]. A measurement campaign was conducted to produce high-resolution gamma spectroscopy enrichment meter data comparable to UF 6 cylinder measurements. The purpose of this report is to provide both an introduction to and quality assurance (QA) of the raw data produced. This report is intended for the analyst or researcher who uses the raw data. Unfortunately, the raw data (i.e., the spectra files) are too voluminous to include in this report but can be requested from Steven Croft of the Safeguards & Security Technology Group (scroft@ornl.gov 865-241-2834). The complete processed data are tabulated in Appendix A. The analysis techniques used to produce the QA data presented in this report [e.g., three regions-ofinterest (ROI) peak extraction and batch analysis processes] are not the most sophisticated techniques available; analysts are encouraged to reanalyze the raw data using more sensitive techniques and to improve upon the results presented here. With that being said, the analysis techniques used here are more than adequate to present and inspect the quality of the data.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of asymmetries of Cd(Zn)Te devices investigated using photo-induced current transient spectroscopy, Rutherford backscattering, surface photo-voltage spectroscopy, and gamma ray spectroscopies

Despite these recent advancements in preparing the surface of Cd(Zn)Te devices for detector applications, large asymmetries in the electronic properties of planar Cd(Zn)Te detectors are common. Furthermore, for the development of patterned electrode geometries, selection of each electrode surface is crucial for minimizing dark current in the device. This investigation presented here has been carried out with three objectives. Each objective is oriented towards establishing reliable methods for the selection of the anode and cathode surfaces independent of the crystallographic orientation. The objectives of this study are (i) investigate how the asymmetry in I-V characteristics of Cd(Zn)Te devices may be associated with the TeO2 interfacial layer using Rutherford backscattering to study the structure at the Au-Cd(Zn)Te interface, (ii) develop an understanding of how the concentration of the active traps in Cd(Zn)Te varies with the external bias, and (iii) propose non-destructive methods for selection of the anode and cathode which are independent of crystallographic orientation. The spectroscopic methods employed in this investigation include Rutherford backscattering spectroscopy, photo-induced current transient spectroscopy, and surface photo-voltage spectroscopy, as well as gamma ray spectroscopy to demonstrate the influence on detector properties.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Neutron counting and gamma spectroscopy with PVT detectors.

Radiation portals normally incorporate a dedicated neutron counter and a gamma-ray detector with at least some spectroscopic capability. This paper describes the design and presents characterization data for a detection system called PVT-NG, which uses large polyvinyl toluene (PVT) detectors to monitor both types of radiation. The detector material is surrounded by polyvinyl chloride (PVC), which emits high-energy gamma rays following neutron capture reactions. Assessments based on high-energy gamma rays are well suited for the detection of neutron sources, particularly in border security applications, because few isotopes in the normal stream of commerce have significant gamma ray yields above 3 MeV. Therefore, an increased count rate for high-energy gamma rays is a strong indicator for the presence of a neutron source. The sensitivity of the PVT-NG sensor to bare {sup 252}Cf is 1.9 counts per second per nanogram (cps/ng) and the sensitivity for {sup 252}Cf surrounded by 2.5 cm of polyethylene is 2.3 cps/ng. The PVT-NG sensor is a proof-of-principal sensor that was not fully optimized. The neutron detector sensitivity could be improved, for instance, by using additional moderator. The PVT-NG detectors and associated electronics are designed to provide improved resolution, gain stability, and performance at high-count rates relative to PVT detectors in typical radiation portals. As well as addressing the needs for neutron detection, these characteristics are also desirable for analysis of the gamma-ray spectra. Accurate isotope identification results were obtained despite the common impression that the absence of photopeaks makes data collected by PVT detectors unsuitable for spectroscopic analysis. The PVT detectors in the PVT-NG unit are used for both gamma-ray and neutron detection, so the sensitive volume exceeds the volume of the detection elements in portals that use dedicated components to detect each type of radiation.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simultaneous beta and gamma spectroscopy

A phoswich radiation detector for simultaneous spectroscopy of beta rays and gamma rays includes three scintillators with different decay time characteristics. Two of the three scintillators are used for beta detection and the third scintillator is used for gamma detection. A pulse induced by an interaction of radiation with the detector is digitally analyzed to classify the type of event as beta, gamma, or unknown. A pulse is classified as a beta event if the pulse originated from just the first scintillator alone or from just the first and the second scintillator. A pulse from just the third scintillator is recorded as gamma event. Other pulses are rejected as unknown events.

Farsoni, Abdollah T↗

FaNGaS: a New Instrument for Fast Neutron Gamma Spectroscopy at FRM II Research Reactor at Garching

For the identification and quantification of actinides in radioactive packages, the non-destructive method of Prompt-Gamma Activation Analysis (PGAA) is applied. To investigate the inelastic (n, n 'γ) scattering, a new instrumentation was installed at the FRM II research reactor. It is designed to exploit the 10{sup 8} cm{sup -2}s{sup -1} neutrons at an average neutron energy of 1.9 MeV delivered by the SR10 beam line. The outgoing prompt γ-rays are measured utilizing a 50% efficiency HPGe detector. Since the cross sections are expected to be low for such a process, two related factors had to be taken into account for the design of the instrumentation: the high beam intensity at the sample position and the high signal-to-background ratio seen by the detector. Eventual low energy neutrons due to the multiple scatterings through the beam line can be minimized using collimators in the beam tube. This has also an effect to a prior neutrons and photons background reduction of the experimental environment. A higher efficiency of the counting can be achieved by the lowering of background at the detector. In this case, a heavy shielding for both neutrons and photons, is designed around the detector while optimizing the sample-detector distance. Monte-Carlo simulation studies were conducted to effectively design the fast neutron beam collimators and the detector shield. A detailed description of the setup characterization and results from simulations and experimental measurements will be discussed through this contribution. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Strontium Iodide Instrument Development for Gamma Spectroscopy and Radioisotope Identification

Development of the Europium-doped Strontium Iodide scintillator, SrI2(Eu), has progressed significantly in recent years. SrI2(Eu) has excellent material properties for gamma ray spectroscopy: high light yield (>80,000 ph/MeV), excellent light yield proportionality, and high effective atomic number (Z=49) for high photoelectric cross-section. High quality 1.5 and 2 diameter boules are now available due to rapid advances in SrI2(Eu) crystal growth. In these large SrI2(Eu) crystals, optical self-absorption by Eu2+ degrades the energy resolution as measured by analog electronics, but we mitigate this effect through on-the-fly correction of the scintillation pulses by digital readout electronics. Using this digital correction technique we have demonstrated energy resolution of 2.9% FWHM at 662 keV for a 4 in3 SrI2(Eu) crystal, over 2.6 inches long. Based on this digital readout technology, we have developed a detector prototype with greatly improved radioisotope identification capability compared to Sodium Iodide, NaI(Tl). The higher resolution of SrI2(Eu) yields a factor of 2 to 5 improvement in radioisotope identification (RIID) error rate compared to NaI(Tl).

energy resolution↗

A Multi-Contact, Low Capacitance HPGe Detector for High Rate Gamma Spectroscopy

The detection, identification and non-destructive assay of special nuclear materials and nuclear fission by-products are critically important activities in support of nuclear non-proliferation programs. Both national and international nuclear safeguard agencies recognize that current accounting methods for spent nuclear fuel are inadequate from a safeguards perspective. Radiation detection and analysis by gamma-ray spectroscopy is a key tool in this field, but no instrument exists that can deliver the required performance (energy resolution and detection sensitivity) in the presence of very high background count rates encountered in the nuclear safeguards arena. The work of this project addresses this critical need by developing a unique gamma-ray detector based on high purity germanium that has the previously unachievable property of operating in the 1 million counts-per-second range while achieving state-of-the-art energy resolution necessary to identify and analyze the isotopes of interest. The technical approach was to design and fabricate a germanium detector with multiple segmented electrodes coupled to multi-channel high rate spectroscopy electronics. Dividing the germanium detector’s signal electrode into smaller sections offers two advantages; firstly, the energy resolution of the detector is potentially improved, and secondly, the detector is able to operate at higher count rates. The design challenges included the following; determining the optimum electrode configuration to meet the stringent energy resolution and count rate requirements; determining the electronic noise (and therefore energy resolution) of the completed system after multiple signals are recombined; designing the germanium crystal housing and vacuum cryostat; and customizing electronics to perform the signal recombination function in real time. In this phase I work, commercial off-the-shelf electrostatic modeling software was used to develop the segmented germanium crystal geometry, which underwent several iterations before an optimal electrode configuration was found. The model was tested and validated against real-world measurements with existing germanium detectors. Extensive modeling of electronic noise was conducted using established formulae, and real-world measurements were performed on candidate front-end electronic components. This initial work proved the feasibility of the design with respect to expected high count rate and energy resolution performance. Phase I also delivered the mechanical design of the detector housing and vacuum cryostat to be built in Phase II. Finally, a Monte Carlo simulation was created to show the response of the complete design to a Cs-137 source. This development presents a significant advance for nuclear safeguards instrumentation with increased speed and accuracy of detection and identification of special nuclear materials. Other significant applications are foreseen for a gamma-ray detector that delivers high energy resolution (1keV FWHM noise) at high count rate (1 Mcps), especially in the areas of physics research and materials analysis.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Proton Radioactivity in {sup 117}La and {gamma}-spectroscopy of {sup 117}La, {sup 117}Ba and {sup 151}Lu Using RDT Method

Proton radioactivity of {sup 117}La, was measured with much improved statistics, but no evidence is observed for the isomeric proton decay. Prompt {gamma}-rays were identified in proton emitters {sup 117}La, {sup 151}Lu, and beta-delayed proton precursor {sup 117}Ba using recoil decay tagging method by coupling the Gammasphere Ge array at the target position with the Argonne Fragment Mass Analyzer (FMA)

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Perspectives for neutron and gamma spectroscopy in high power laser driven experiments at ELI-NP

The measurement of energy spectra of neutrons and gamma rays emitted by nuclei, together with charge particles spectroscopy, are the main tools for understanding nuclear phenomena occurring also in high power laser driven experiments. However, the large number of particles emitted in a very short time, in particular the strong X-rays flash produced in laser-target interaction, impose adaptation of technique currently used in nuclear physics experiment at accelerator based facilities. These aspects are discussed (Section 1) in the context of proposed studies at high power laser system of ELI-NP. Preliminary results from two experiments performed at Titan (LLNL) and ELFIE (LULI) facilities using plastic scintillators for neutron detection (Section 2) and LaBr{sub 3}(Ce) scintillators for gamma detection (Section 3) are presented demonstrating the capabilities and the limitations of the employed methods. Possible improvements of these spectroscopic methods and their proposed implementation at ELI-NP will be discussed as well in the last section.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Image Recognition Techniques for Gamma Spectroscopy

Photons, after generated from a radioactive source and before they deposit their energy in a photo detector, are subsequent to multiple scattering mechanisms. As a result, the measured energy from the photo detector is different from the energy the photon had when generated. This is known as folding of the photon energy. Moreover, statistical fluctuation inside the detector contribute to energy folding. In this work, a new method is presented for unfolding the gamma ray spectrum. The method uses a 2-dimensional representation of the measured spectrum (image) and then uses image recognition techniques, and especially differential edge detection, to generate the original spectrum.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Integrated soft snake robot for gamma spectroscopy of radiologically contaminated ducting

Anticipated growth in the number and complexity of nuclear facilities entering the decommissioning phase of their lifespan requires innovative methods of mitigating radiological and safety hazards for workers. Advancements in robotics provide opportunities for remote characterization of radiologically contaminated ducts and pipes, reducing worker exposure. However, the nuclear decommissioning industry has shown a hesitancy in adopting new technology due to concerns regarding capital costs and a lack of demonstration data in representative environments. This work aims to leverage novel soft robotics to develop and demonstrate a sensor-integrated characterization tool for contaminated ducting systems. Two gamma spectrometers – one scintillation-based and one solid-state – were selected and integrated into a pneumatically-actuated snake-like soft robot using stretchable electronic cabling. The robot was then demonstrated at the Idaho National Laboratory’s Critical Infrastructure Test Range Complex. The robot maneuvered through a pseudo-constrained corridor containing several sealed sources and the integrated spectrometers collected spectra at various points along the path of travel. Both spectrometers successfully collected spectra with identifiable, isotope-specific peaks. To evaluate the effect of contamination buildup on the collected spectra, the robot with the integrated scintillation detector was tested using a liquid radioactive source. The resulting spectra showed little detection interference from the liquid contamination; however, a short-lived isotope was used which may not be representative of longer-lived contamination.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗