Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flow Conditions”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Analysis of silica fouling on nonwetting surfaces

Ground water sources used as coolant fluids in a variety of thermal systems such as heat exchangers and power plant condensers contain silica particles that accrete on heat transfer surfaces over time leading to reduction in thermal performance, a problem that is particularly exacerbated with temperature. Nonwetting superhydrophobic, lubricant-infused, and a new class of solid-infused surfaces introduced in this work are candidates for fouling mitigation, by virtue of their water repellency, but little is known about fouling of silica on the surfaces, especially under dynamic flow conditions and as a function of temperature. This article presents, for the first time, a systematic study of dynamic flow fouling of silica on nonwetting surfaces vis-à-vis conventional copper surface over a temperature range 20–50°C. The mechanism of silica aggregate formation and its adherence to the different surfaces is elucidated by scanning electron microscope (SEM) imaging. Sigmoidal growth model is used to describe the time evolution of fouling thermal resistance and an Arrhenius model is presented for the temperature-dependent increase in the asymptotic fouling resistance on nonwetting and conventional surfaces alike. Lubricant-infused and solid-infused surfaces are shown to reduce fouling thermal resistance by up to 25% and 13%, respectively, compared to a conventional surface, whereas superhydrophobic surfaces lose their non-wettability under flow conditions, leading to an adverse increase in the fouling resistance by up to 13%. Considering the possible lubricant depletion in lubricant-infused surfaces over prolonged exposure to a flowing fluid, solid-infused surfaces present a robust alternative.

42 ENGINEERING↗

Integrated positron emission particle tracking (PEPT) and X-ray computed tomography (CT) imaging of flow phenomena in twisted tape swirl flow

Abstract A combined positron emission particle tracking (PEPT) and X-ray computed tomography (CT) technique is presented, and its utility is demonstrated through investigation of flow in a pipe with twisted tape swirl insert with varying flow conditions (diameter-based Reynolds numbers 16,300–63,300). A description of this technique is given, as well as data handling practices used to relate geometric information captured by CT to fluid flow data gathered via PEPT. It is found that the CT component is readily capable of capturing the stainless steel insert geometry in this present system, but the use of combined plastic and metal materials leads to artifacts in imaging of the plastic surface. Nonetheless, CT data are related to PEPT flow measurements, and average velocity fields are calculated via a pseudo-framing and interpolation scheme and used to visualize and interrogate key flow phenomena within the system. Radial velocity profiles of the mean flow characteristics are seen to collapse to a nearly common form across all flow conditions considered. Helical vortices are seen propagating through the flow field, generated by bypass flow around the gap between the insert and pipe wall, with additional coherent secondary flow structures seen in the higher Reynolds number cases. These findings enhance the understanding of the mixing mechanisms in these swirl flows and encourage the continued development of PEPT-CT methodologies for 3D flow measurements in optically inaccessible systems.

42 ENGINEERING↗

Effect of Glacial/Interglacial Recharge Conditions on Flow of Meteoric Water Through Deep Orogenic Faults: Insights Into the Geothermal System at Grimsel Pass, Switzerland

Many meteoric-recharged, fault-hosted geothermal systems in amagmatic orogenic belts have been active through the Pleistocene glacial/interglacial climate fluctuations. The effects of such climate-induced recharge variations on fluid flow patterns and residence times of the thermal waters are complex and may influence how the geothermal and mineralization potential of the systems are evaluated. We report systematic thermal–hydraulic simulations designed to reveal the effects of recharge variations, using a model patterned on the orogenic geothermal system at Grimsel Pass in the Swiss Alps. Fault-bound circulation of meteoric water through the Grimsel fault is driven to depths of ~10 km by the high alpine topography. Simulations suggest that the current single pass flow is typical of interglacial periods, during which 1) meteoric recharge into the fault is high (above tens of centimeters per year), 2) conditions are at or somewhat below the critical Rayleigh number, and 3) the hydraulic connectivity along the fault plane is extensive (an extent of at least 10 km into increasingly higher terrain is required to explain the 10 km penetration depth). The subcritical condition constrains the bulk fault permeability to < 1e-14 m2. In contrast, the limited recharge during the numerous Pleistocene glaciation events likely induced a layered flow system with single pass flow confined to shallow depths while non-Rayleigh convection occurred in the deep fault. The same layering can be observed at low aspect ratios (length/depth) of the fault plane, when the available recharge area limits the flux through the fault.

58 GEOSCIENCES↗

Progress in the validation of rotor aerodynamic codes using field data

Within the framework of the fourth phase of the International Energy Agency (IEA) Wind Task 29, a large comparison exercise between measurements and aeroelastic simulations has been carried out featuring three simulation cases in axial, sheared and yawed inflow conditions. Results were obtained from more than 19 simulation tools originating from 12 institutes, ranging in fidelity from blade element momentum (BEM) to computational fluid dynamics (CFDs) and compared to state-of-the-art field measurements from the 2 MW DanAero turbine. More than 15 different variable types ranging from lifting-line variables to blade surface pressures, loads and velocities have been compared for the different conditions, resulting in over 250 comparison plots. The result is a unique insight into the current status and accuracy of rotor aerodynamic modeling. For axial flow conditions, a good agreement was found between the various code types, where a dedicated grid sensitivity study was necessary for the CFD simulations. However, compared to wind tunnel experiments on rotors featuring controlled conditions, it remains a challenge to achieve good agreement of absolute levels between simulations and measurements in the field. For sheared inflow conditions, uncertainties due to rotational and unsteady effects on airfoil data result in the CFD predictions standing out above the codes that need input of sectional airfoil data. However, it was demonstrated that using CFD-synthesized airfoil data is an effective means to bypass this shortcoming. For yawed flow conditions, it was observed that modeling of the skewed wake effect is still problematic for BEM codes where CFD and free vortex wake codes inherently model the underlying physics correctly. The next step is a comparison in turbulent inflow conditions, which is featured in IEA Wind Task 47. Doing this analysis in cooperation under the auspices of the IEA Wind Technology Collaboration Program (TCP) has led to many mutual benefits for the participants. The large size of the consortium brought ample manpower for the analysis where the learning process by combining several complementary experiences and modeling techniques gave valuable insights that could not be found when the analysis is carried out individually.

17 WIND ENERGY↗

Hanford Waste Treatment Plant LAB Facility Stack Effluent Monitoring: Sampling Probe Location Qualification Evaluation

The WTP LAB stack monitor locations were qualified using scale model stacks to mitigate the risk of identifying that sampling locations do not meet the qualification criteria on the full-scale stack. As required by the ANSI/HPS N13.1-1999 standard, the scale model and its sampling location were geometrically similar to the actual stack and the Reynolds numbers for both the actual and model stacks were >10,000. An additional criterion is that the DV of the full-scale stack must be between 1/6 DV and 6 DV of the scale model stack tests. Verification tests of the LAB stacks were performed at normal operating conditions. The maximum 6 DV value from the scale model testing determines the maximum conditions for which the full-scale stack may be operated and remain in compliance with the stack verification criterion. The remaining criteria for the stack verification to be considered valid involve the flow angle and velocity uniformity results. First, the flow angle at the full-scale stack must be = 20°. Second, the velocity uniformity at the full-scale stack must be = 20% COV. Finally, the velocity uniformity results for the actual and scale model stacks must agree within 5% COV. In general, these criteria were met through the full-scale stack tests at the LAB facility. Some specific items for each scale model and full-scale stack comparison should be noted in assessing the validity of the verification tests. The LB-C2 scale model stacks were performed with single fan operations at then-minimum flow conditions. These conditions resulted in DV values that were too low to meet the DV range criterion, and therefore are unable to be used in qualifying single fan operations on the full-scale stack. However, the single fan operations demonstrated COV values for velocity uniformity as well as flow angles that were comparable to the dual-fan operations at high flows. Overall, the test conditions and test results were within the range of acceptable values based on current design flow rates. Single fan operations are expected to only occur infrequently for maintenance needs and is therefore not a planned operating condition at this time. The LB-S1 scale model stacks were performed at three fan combinations, and in each combination, at least one test was performed at the then-minimum flow conditions as well as at then-maximum flow conditions. While the then-minimum flow conditions result in a DV range that is lower than the verification test DV value, and therefore does not meet the criterion, these tests are un-necessary for the verification test acceptance. The normal and maximum flow conditions from the scale model stack tests meet the DV range criterion, and the velocity uniformity test results compare favorably with the full-scale stack results. The LB-S2 scale model stacks were performed at nominally the same maximum flow condition; however, the 6 DV value for Fan A operation was slightly lower than the full-scale stack test DV. The COV values from the scale model stacks were comparable between the Fan A and Fan B results, and the overall test conditions are within the range of acceptable values. The stack verification is therefore considered acceptable for both Fan A and Fan B operations. The verification tests were performed at flows that were appreciably higher than the design conditions, and further elevated flow rates would be beyond the range of acceptable DV. Based on these stack verification test results, the three LAB filtered exhaust stacks meet the qualification criteria provided in the ANSI/HPS N13.1-1999 standard. Further changes to the system configuration or operating conditions that are outside the bounds described in this and the scale model test reports (Glissmeyer, Flaherty, and Piepel (2001), Glissmeyer and Geeting (2013)) may require additional tests and additional analyses to determine compliance with the standard.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Bayesian parameter estimation and evaluation of the K -ω shear stress transport model for plane impinging jets

Numerical simulations with semi-empirical turbulence models are commonly used to model impinging jets, often used for cooling solid surfaces. In this work, the constants in the k-ω shear stress transport model in ANSYS FLUENT are calibrated to experimental velocity and heat transfer data for a plane turbulent impinging air jet to determine if Kennedy-O'Hagan calibration (Kennedy and O'Hagan 2001 J. R. Stat. Soc. B 63 425–64) can improve predictions of near-surface velocities and surface Nusselt numbers for similar flows. Impinging jets have been proposed to cool the target plates of the divertor in future magnetic fusion energy reactors, where simulations are used to estimate divertor performance. The flat-plate divertor (Wang et al 2009 Fusion Sci. Technol .56 1023–7) uses a plane jet of helium issuing from a B = 0.5 mm slot to cool a surface with radius of curvature of 44 B at a distance 4 B from the slot. Predictions from the calibrated numerical model are compared with independent experimental data at different flow conditions, as well as surface temperature data for a flat plate divertor test section. The contribution of this work is evaluation of the accuracy of a calibrated turbulence model for modest extrapolations in flow geometry and flow conditions for a plane impinging jet.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Utah FORGE Hydrothermal Friction-Hydraulic Transmissivity Laboratory Experiments

Submission includes data from laboratory slide-hold-slide tests, combined with flow through tests, conducted on Westerly granite with 30 degree sawcut. Tests were conducted with a constant confining pressure of 30 MPa with an average pore pressure of 10 MPa at temperatures of 23 and 200 degC. Three fluid flow conditions were examined (1) no flow, (2) cycled flow, and (3) continuous flow. Data were collected to asses the effect of temperature and pore fluid on frictional healing rates in granite at geothermal conditions. Data is available in XML and JSON data types.

15 GEOTHERMAL ENERGY↗

Sensitivity Analysis of Transient Critical Heat Flux by RIA Under High-Pressure Flow Boiling Conditions in TRTL

A reactivity-initiated accident (RIA) is a design-basis accident under which critical heat flux (CHF) is likely to be exceeded. The operational margin for RIAs is currently determined using steady-state CHF lookup tables, which provide conservative estimates relative to transient CHF phenomena. The Transient Reactor Test Loop (TRTL) facility at Oregon State University is capable of performing out-of-pile rapid heating experiments representative of a RIA at conditions representative of a pressurized water reactor (PWR). Here, to further our understanding of and ability to predict transient CHF under PWR conditions, we performed a sensitivity analysis on a RELAP5-3D model of the TRTL facility coupled to the RAVEN code framework to define a proposed experimental test matrix to be performed at the TRTL facility. We then implemented a flow boiling CHF correlation into RELAP5-3D and performed a secondary sensitivity analysis inspecting the impact of the built-in RELAP5-3D CHF and heat transfer multipliers on both the prediction of CHF and key safety parameters, such as peak cladding temperature and heat flux. The results show that the multiplier with the highest influence toward the prediction of CHF occurrence and the safety parameters is the transient CHF multiplier. Operational performance envelopes have been developed for each of the test matrix cases and will be used for validation once the experiments are performed. The TRTL facility is currently performing shakedown testing to verify system performance prior to proceeding with the experimental campaign. Restart testing results include pump curve restart testing, pressure tests, and heater rod thermocouple transients.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Constructing A New CHF Look-Up Table Based on the Domain Knowledge Informed Machine Learning Methodology

Accurate prediction of CHF under various fluid flow conditions continues to be required for design, operation and safety analysis of light water reactor rod bundles. Due to the lack of in-depth physical understanding as well as limited high-resolution data in the micro-scale flow and heat transfer, the existing models feature a sub-optimal uncertainty band. In this study, driven by the prior domain knowledge information obtained, an improved CHF look-up table is developed through unified machine learning algorithms for the vertical flow conditions within tube and annulus geometry. The Groeneveld 2006 look-up table is used as the domain knowledge to train machine learning process against tube and annulus CHF data for both DNB and DO type. The new look-up table shows improved accuracy for conditions relevant to PWRs and BWRs. In addition, its domain knowledge informed nature ensures that a rationale prediction can be made, thus accounting for previous valuable information in the machine learning model training process.

Jin, Yue↗

Tidal Turbine Benchmarking Project: Stage I - Steady Flow Blind Predictions: Preprint

This paper presents the first blind prediction stage of the Tidal Turbine Benchmarking Project being conducted and funded by the UK's EPSRC and Supergen ORE Hub. In this first stage, only steady flow conditions, at low and elevated turbulence (3.1%) levels, were considered. Prior to the blind prediction stage, a large laboratory scale experiment was conducted in which a highly instrumented 1.6m diameter tidal rotor was towed through a large towing tank in well-defined flow conditions with and without an upstream turbulence grid. Details of the test campaign and rotor design were released as part of this community blind prediction exercise. Participants were invited to use a range of engineering modelling approaches to simulate the performance and loads of the turbine. 26 submissions were received from 12 groups from across academia and industry using solution techniques ranging from blade resolved computational fluid dynamics through actuator line, boundary integral element methods, vortex methods to engineering Blade Element Momentum methods. The comparisons between experiments and blind predictions were extremely positive helping to provide validation and uncertainty estimates for the models, but also validating the experimental tests themselves. The exercise demonstrated that the experimental turbine data provides a robust data set against which researchers and design engineers can test their models and implementations to ensure robustness in their processes, helping to reduce uncertainty and provide increased confidence in engineering processes. Furthermore, the data set provides the basis by which modellers can evaluate and refine approaches.

benchmarking↗

Groundwater regulates interannual variations in evapotranspiration in a riparian semiarid ecosystem

Dryland ecosystems are an important component of Earth’s carbon, water, and energy budgets. Changes in hydroclimatic conditions can significantly alter land surface fluxes in these ecosystems. In regions with groundwater-river water exchange, land surface fluxes are strongly modulated by groundwater table fluctuations in response to river stage variations; however, interactions between fluxes and groundwater remain poorly understood in drylands. Here, we use eddy covariance data collected in paired upland and riparian semiarid ecosystems during two years with contrasting river flow conditions to examine interactions among river stage conditions, water table dynamics, meteorological drivers, and ecosystem fluxes. Elevated groundwater availability resulting from groundwater-surface water exchange at the riparian site enhanced the latent heat flux (LE, the energy form of evapotranspiration), which was sustained longer in the growing season during both years. At the upland site, mean LE during the dry season differed by less than 2% between the two years. In contrast, at the riparian site contrasting river flow conditions resulted in a 41% difference in peak monthly LE between the two years. The two-year mean LE in the summer at the riparian site was twice that at the upland site. Carbon uptake (NEP) and LE were well correlated at the upland site during both years, but at the riparian site enhanced summertime LE during the high river flow year did not correspond t enhanced NEP. Our results demonstrate that enhanced groundwater availability modulated by river stage variability is a critical driver of land surface fluxes in semiarid riparian ecosystems.

Missik, Justine E.↗

Field Testing of Self-Healing Metallic Coatings for Internal Corrosion Protection of Natural Gas Pipelines

Internal corrosion occurs in natural gas pipelines primarily due to the presence of water, carbon dioxide, and hydrogen sulfide. Internal corrosion can eventually result in leakage, cracks, and rupture of the pipeline. The objective of this work is to mitigate internal corrosion in steel pipelines transporting natural gas using cold spray coatings. The corrosion behavior of carbon steel coated with self-healing zinc chromium (ZnCr) and zinc niobium (ZnNb) cold spray coatings was investigated in a natural gas environment. For comparison purposes, hot-dip galvanized steel (HDGS) was tested under the same conditions as cold spray coatings. The field test was performed at the NW Natural gas storage facility in Mist, Oregon. The field test was conducted in a 6-inch diameter pipe transporting wet natural gas out of an underground storage well at 500 psi and 4.4 °C. The coupons were tested for 15 and 32 days under stagnant and flow conditions, respectively. Weight loss method was used to measure the corrosion rate of metallic coatings. Post-corrosion surface characterization was performed on the specimen using a scanning electron microscopy (SEM) equipped with energy dispersive X-ray spectroscopy (EDS). Crystalline phases were determined by X-ray diffraction (XRD). The field-test results confirmed that the metallic coatings provided corrosion protection of carbon steel exposed to wet natural gas under stagnant and flow conditions. The formation of the ZnCO 3 layer on top of ZnNb and ZnCr coatings led to passivation of the coatings which helps to reduce the self-corrosion. These layers form a barrier for diffusion of corrosive species to the surface.

03 NATURAL GAS↗

Comparison of modular analytical wake models to the Lillgrund wind plant

Efficient and accurate wake models are required for wind plant performance modeling and the suite of engineering processes that support wind plant layout, control, and monitoring. Although many analytical and engineering wake models with low computational costs have been proposed, their ability to represent the power production of large wind plants in a wide range of atmospheric conditions is not completely understood. The following validation study reviews the underlying theory for analytical wake models, outlines quality control procedures for observational data, and compares model results with observational data from the Lillgrund Wind Plant. Lillgrund makes a valuable case study for wake modeling because of its regular arrangement and the relatively close spacing of constituent wind turbines, which lead to regular and significant wake interactions within the wind plant and the development of deep array flow conditions. Formulations for the velocity deficit, wake-added turbulence, and wake superposition methods are considered in a modular sense, yielding many possible configurations to represent wind turbine wakes, of which seven are examined in detail. Velocity deficit models that account for flow conditions in the near wake are better able to reproduce power production for wind turbines in the transitional region of the wind plant, where wind turbines experience as many as five wakes from upstream turbines. Finally, in the deep array, where power production reaches asymptotic values and wake statistics become quasi-periodic, wake superposition schemes become the largest driver in error reduction; using the linear or maximum wake superposition methods can reduce the relative root mean square error by as much as 40% in the deep array.

17 WIND ENERGY↗

Surface Treatment Strategies for Mitigating Gas Hydrate & Asphaltene Formation, Growth, and Deposition in Flowloops

Abstract Numerous solids including gas hydrates, waxes, and asphaltenes have the potential to form in the production lines of gas and oil fields. This creates a highly non-ideal scenario as the accumulation of said species leads to flow assurance issues, especially with long-term processes like deposition. Since an ever-increasing amount of material is deposited in place at the pipe surface, production stoppage or active mitigation efforts become inevitable. The latter production issues result in increased safety risks and operational expenditures. Therefore, a cost-effective, passive deposition mitigation technology, such as a pipeline coating or surface treatment is especially appealing. The ability to address multiple pipeline flow assurance issues simultaneously without actively disrupting production would represent a dramatic step forward in this area. This study is part of a long-term ongoing effort that evaluates the performance and application of an omniphobic surface treatment for solids deposition prevention in industrially relevant systems. In particular, this specific work concentrates on the efficacy and robustness of the treatment under fully flowing conditions. The apparatuses utilized for this include two flowloops: a lab-scale, high-pressure flowloop for gas hydrate and surface treatment durability studies, and a bench-scale, atmospheric pressure loop for crude oil and asphaltene experiments. Film growth in high-pressure flowloop tests corroborated previous reports of delayed gas hydrate nucleation observed in rocking cells. Without the aid of the memory effect, treated oil-dominated experiments never experienced hydrate formation, spending upwards of a week in the hydrate stability zone (at the subcooled/fluid test conditions). Subsequent tests which utilized the memory effect then revealed that the hydrate formation rate reduced in the presence of the surface treatment compared to a bare stainless-steel surface. This testing was part of a larger set of trials conducted in the flowloop, which lasted about one year. The surface treatment durability under flowing conditions was evaluated during this time. Even after experiencing ∼4000 operating hours and 2 full pressure cycles, no evidence of delamination or damage was detected. Finally, as part of an extension to previous work, corroded surface asphaltene deposition experiments were performed in a bench-top flowloop. Treated experiments displayed an order of magnitude reduction in both total oil (all fractions of crude oil) and asphaltene fraction deposited.

03 NATURAL GAS↗

FSVPy: A python-based package for fluorescent streak velocimetry (FSV)

Predictive constitutive equations that connect easy-to-measure transport properties (e.g., viscosity and conductivity) with system performance variables (e.g., power consumption and efficiency) are needed to design advanced thermal and electrical systems. In this work, we explore the use of fluorescent particle-streak analysis to directly measure the local velocity field of a pressure-driven flow, introducing a new Python package (FSVPy) to perform the analysis. Fluorescent streak velocimetry combines high-speed imaging with highly fluorescent particles to produce images that contain fluorescent streaks, whose length and intensity can be related to the local flow velocity. By capturing images throughout the sample volume, the three-dimensional velocity field can be quantified and reconstructed. We demonstrate this technique by characterizing the channel flow profiles of several non-Newtonian fluids: micellar Cetylpyridinium Chloride solution, Carbopol 940, and Polyethylene Glycol. We then explore more complex flows, where significant acceleration is created due to microscale features encountered within the flow. We demonstrate the ability of FSVPy to process streaks of various shapes and use the variable intensity along the streak to extract position-specific velocity measurements from individual images. Thus, we demonstrate that FSVPy is a flexible tool that can be used to extract local velocimetry measurements from a wide variety of fluids and flow conditions.

Mechanics↗

Nutrient Replenishment by Turbulent Mixing in Suspended Macroalgal Farms

Abstract This study uses large eddy simulations to investigate nutrient transport and uptake in suspended macroalgal farms. Various farm configurations and oceanic forcing conditions are examined, with the farm base located near the nutricline depth. We introduce the Damkohler number Da to quantify the balance between nutrient consumption by macroalgae uptake and supply by farm‐enhanced nutrient transport. Most cases exhibit low Da , indicating that farm‐generated turbulence drives sufficient upward nutrient fluxes, supporting macroalgae growth. High Da and starvation may occur in fully grown farm blocks, a configuration that generates the weakest turbulence, particularly when combined with densely planted macroalgae or weak flow conditions. Flow stagnation within the farm due to macroalgae drag may constrain the uptake efficiency and further increase the starvation risk. Mitigation strategies involve timely harvesting, avoiding dense macroalgae canopies, and selecting farm locations with robust ocean currents and waves. This study provides insights for sustainable macroalgal farm planning.

Geology↗

Hydrobiological Mechanism Controlling the Synergistic Effects of Unsaturated Flow and Soil Organic Matter on the Degradation of Emerging Organic Contaminants in Soils

We report hydrology is a key factor influencing microbial degradation of emerging organic contaminants (EOCs) in soils, but the underlying mechanisms are not clear. In this study, biotic and abiotic column experiments were performed to investigate the removal and degradation of five EOCs in soils with different soil organic matter (SOM) contents under saturated and unsaturated flow conditions. In biotic experiments, 54–90% of bisphenol A (BPA) and 9–22% of ibuprofen (IBU) were removed from the aqueous phase of saturated columns due to adsorption and biodegradation. The biodegradation removed 26–65% of BPA and 1–22% of IBU. Decreasing soil pore water saturation from 100 to 80% increased BPA removal to 97–100% and IBU removal to 42–43% due to increased biodegradation (67–81% for BPA and 36–39% for IBU). No significant removal of BPA and IBU was observed in SOM-removed soils under saturated and unsaturated flow conditions. The desaturation did not influence sorptive losses of BPA (< 27%) and IBU (< 7%), suggesting their negligible adsorption at air–water interfaces but increased biodegradation of BPA and IBU sorbed at SOM–water interfaces. The study shows that soil drying and SOM can synergistically degrade BPA and IBU but have no effect on recalcitrant carbamazepine, tetracycline, and ciprofloxacin.

54 ENVIRONMENTAL SCIENCES↗

Long-Term Static and Dynamic Corrosion Stability of Nonwetting Surfaces

Superhydrophobic surfaces (SHSs) and lubricant-infused surfaces (LISs) are two classes of nonwetting surfaces that have drawn attention due to their advanced functional properties including corrosion inhibition. Yet there is a conspicuous lack of corrosion study of SHSs and LISs with respect to their fabrication and material parameters, especially at high temperatures and under dynamic flow conditions over long durations, which is sought to be addressed in this article. Considering copper SHSs and LISs, a full factorial combinatorial study of two facile texturing processes, electrodeposition and etching, two different functionalization agents, stearic acid and mercaptan, and two types of infused lubricants, Krytox 104 and DOWSIL 510, is presented, encompassing over 650 measurements on 90 tested surfaces. All fabricated surfaces demonstrated water repellency with a contact angle above 150° and a sliding angle below 7°. For the first time, the study examines high-temperature corrosion stability and long-term corrosion durability of the nonwetting surfaces in both static fluid and dynamic turbulent flow conditions over a period of 30 days. Here, LISs and SHSs are shown to provide excellent corrosion inhibition over all tested corrosion conditions, with negligible presence of corrosion species on the surfaces and no deterioration of the texturing. The surfaces are also shown to rejuvenate easily to the initial wettability and corrosion resistance values. This study provides valuable insights into the selection of materials and processing parameters for the fabrication of nonwetting surfaces for the application of interest.

Copper↗