Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Flash Boiling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

52 records · Page 3

Dielectric Fluids for the Direct Forced Convection Cooling of Power Electronics

The future of electrification of vehicles and other systems will require the creation of high-power density power electronics with low junction-to-fluid thermal resistance cooling solutions. One way to create this solution is to move high-heat-flux liquid cooling (single- or two-phase) as close to the power electronics components as possible. One novel approach involves submersion in dielectric fluids as the cooling solution. We first provide the range of fluid properties and develop a figure of merit (FOM) to aid in dielectric fluid selection. Next, we perform computational fluid dynamics/heat transfer (CFD/HT) modeling using single-phase cooling (submerged jet impingement on an enhanced surface) to validate the dielectric fluid FOM. Results of the study show that the developed FOM is a good representation of the performance of the fluids when compared to the results of the CFD/HT analysis. Both FOM and the CFD/HT analysis show that based on pure thermohydraulic considerations, several commercially available fluids present higher performance, on the order of 5% of water. Finally, the FOM can be used to quickly assess the thermohydraulic performance of a dielectric fluid, as well as the secondary application-specific properties such as boiling point, saturation pressure, flash point, and global warming potential, thereby allowing for fluid candidates to be readily compared.

computational fluid dynamics↗

Evaluation of methods and improvement of predictions for specification properties of petroleum-based and alternative aviation fuels

To support our research and process modeling for liquid fuels, including blends, from petroleum and synthetic sources such as from biomass intermediates, we evaluated composition-based prediction methods and improved predictions for five key specification properties of petroleum-based and alternative aviation fuels, namely distillation temperatures (10 % distilled, t 10 , and final boiling point, t FBP ), density, flash point, net heat of combustion, and freezing point. The types of fuels included were petroleum-based jet fuels, jet-fuel surrogate mixtures, synthetic blending components obtained from different sources, and blends of Jet A with many synthetic blending components. Expanded datasets to update associated parameters allowed significant improvements for one of the prediction methods used in earlier work, namely the Modified Weighted Average method published initially by Shi et al. By considering the importance of lighter compounds for flash points and heavier compounds for freezing points, the revised Modified Weighted Average method was further improved. For liquid density, the revised Modified Weighted Average method gave the best overall results. The revised Modified Weighted Average method, the American Society for Testing and Materials D7215 method, and the D7215 method modified by another group gave comparable results for flash point, while the revised Modified Weighted Average and D3338 methods gave the best results for net heat of combustion. Freezing point was well predicted using the revised Modified Weighted Average method and showed the most significant improvements over current predictions. Distillation temperature t 10 was not well predicted, while t FBP was predicted with a mean absolute error comparable to experimental reproducibility.

09 BIOMASS FUELS↗

Explosive Boiling at Very Low Heat Fluxes: A Microgravity Phenomenon

The paper presents experimental observations of explosive boiling from a large (relative to bubble sizes) flat heating surface at very low heat fluxes in microgravity. The explosive boiling is characterized as either a rapid growth of vapor mass over the entire heating surface due to the flashing of superheated liquid or a violent boiling spread following the appearance of single bubbles on the heating surface. Pool boiling data with saturated Freon 113 was obtained in the microgravity environment of the space shuttle. The unique features of the experimental results are the sustainability of high liquid superheat for long periods and the occurrence of explosive boiling at low heat fluxes (0.2 to 1.2 kW/sq m). For a heat flux of 1.0 kW/sq m a wall superheat of 17.9 degrees C was attained in ten minutes of heating. This was followed by an explosive boiling accompanied with a pressure spike and a violent bulk liquid motion. However, at this heat flux the vapor blanketing the heating surface could not be sustained. Stable nucleate boiling continued following the explosive boiling.

Hasan, M. M.↗

Multipurpose top for liquid helium Dewar

Multipurpose top was fabricated for liquid helium Dewar flask which guards against flash vaporization of liquid helium and allows boiling temperature of liquid helium to be lowered by reduction of ambient pressure in Dewar flask. Device is rugged and simple, and does not require frequent calibrations or adjustments.

Murphy, R. S.↗

Blended fuel property analysis of butyl-exchanged polyoxymethylene ethers as renewable diesel blendstocks

Methyl-terminated polyoxymethylene ethers (MM-POMEs), having the formula CH 3 O-(CH 2 O)n-CH 3 (n = 3-6), are a class of oxygenates with desirable diesel-like fuel properties including high cetane number and low soot formation. However, their low energy density and high water-solubility present barriers to their adoption. Both concerns were recently addressed by our research group by synthesizing a mixture of POME structures having butyl end-groups and n = 1-6, termed B*POME1-6. B*POME1-6 maintained the advantageous properties of the parent MM-POMEs, and exhibited improved energy density and most notably, dramatically decreased water solubility. For evaluation against a set of criteria for a blended diesel blendstock, a 20 vol% blend of B*POME1-6 with a base diesel fuel was investigated here. Oxidation stability, cetane number, sooting tendency, lubricity and conductivity were improved in the B*POME1-6 blend compared with the base diesel, while also maintaining the flash point, cloud point, energy density, viscosity, and boiling point requirements. The B*POME1-6 product demonstrated a synergistic blending behavior at 10 vol% and a linear blending behavior at 20-30 vol% blends, in agreement with similar POME blends at comparable blend levels. Finally, common environmental and toxicity models performed on B*POME1-6 component molecules suggested they have a greater propensity to partition into the water compartment compared to a common diesel surrogate, but with a lower tendency to bioaccumulate.

33 ADVANCED PROPULSION SYSTEMS↗

Fuel Properties of Oxymethylene Ethers with Terminating Groups from Methyl to Butyl

Oxymethylene ethers (OMEs) have been studied as possible additives or replacements for diesel fuels. Typically, studies have considered only methyl-terminated OMEs. Recent structure-property relationship models suggest that extended-alkyl OMEs may provide improvements to many of the properties of methyl-terminated OMEs that make them less suitable as diesel fuel blendstocks. In this work, we describe the synthesis and characterization of 16 different OMEs with methyl, ethyl, propyl, butyl, isopropyl, and isobutyl terminating alkyl groups with varying oxymethylene chain length. Indicated Cetane Number, Lower Heating Value, Flash Point, Density, Viscosity, Vapor Pressure, and Oxidative Stability are tested via ASTM standard methods. Additionally, Water Solubility, Boiling Point, seal material compatibility, and sooting propensity (via the Yield Sooting Index) are measured for these fuels. For diesel compatibility, all tested OMEs except smaller methyl and ethyl OMEs, and the branched isopropyl OME, meet cetane number requirements. Further, extending the alkyl end group increases the heating value, but all OMEs, due to their oxygen content, have heating values less than diesel; despite this, all OMEs show significant reductions in soot production per unit heating value. Only the heaviest OMEs meet diesel viscosity requirements, and most are higher density than diesel. OMEs with larger alkyl groups show the highest stability under accelerated auto-oxidation conditions. Increases in alkyl group length cause order of magnitude reduction in water solubility, from hundreds of g/L for methyl terminated OMEs to hundreds of mg/L for butyl terminated OMEs. Limited seal material testing indicates that PEEK polymers are unaffected by OMEs; while extended alkyl groups may improve compatibility with FKM (Viton), other common elastomers (NBR, silicone) remain incompatible with all tested OMEs. Overall, it is found that methyl-terminated OMEs exhibit the most potential for soot reduction, but OMEs with larger propyl and butyl terminating alkyl groups show improved compatibility with existing diesel systems.

09 BIOMASS FUELS↗

Dynamics of face and annular seals with two-phase flow

A detailed study was made of face and annular seals under conditions where boiling, i.e., phase change of the leaking fluid, occurs within the seal. Many seals operate in this mode because of flashing due to pressure drop and/or heat input from frictional heating. High pressure, water pumps, industrial chemical pumps, and cryogenic pumps are mentioned as a few of many applications. The initial motivation was the LOX-GOX seals for the space shuttle main engine, but the study was expanded to include any face or annular seal where boiling occurs. Some of the distinctive behavior characteristics of two-phase seals were discussed, particularly their axial stability. While two-phase seals probably exhibit instability to disturbances of other degrees of freedom such as wobble, etc., under certain conditions, such analyses are too complex to be treated at present. Since an all liquid seal (with parallel faces) has a neutral axial stiffness curve, and is stabilized axially by convergent coning, other degrees of freedom stability analyses are necessary. However, the axial stability behavior of the two-phase seal is always a consideration no matter how well the seal is aligned and regardless of the speed. Hence, axial stability is thought of as the primary design consideration for two-phase seals and indeed the stability behavior under sub-cooling variations probably overshadows other concerns. The main thrust was the dynamic analysis of axial motion of two-phase face seals, principally the determination of axial stiffness, and the steady behavior of two-phase annular seals. The main conclusions are that seals with two-phase flow may be unstable if improperly balanced. Detailed theoretical analyses of low (laminar) and high (turbulent) leakage seals are presented along with computer codes, parametric studies, and in particular a simplified PC based code that allows for rapid performance prediction. A simplified combined computer code for the performance prediction over the laminar and turbulent ranges of a two-phase seal is described and documented. The analyses, results, and computer codes are summarized.

Hughes, William F.↗

Dynamics of face and annular seals with two-phase flow

A detailed study was made of face and annular seals under conditions where boiling, i.e., phase change of the leaking fluid, occurs within the seal. Many seals operate in this mode because of flashing due to pressure drop and/or heat input from frictional heating. Some of the distinctive behavior characteristics of two phase seals are discussed, particularly their axial stability. The main conclusions are that seals with two phase flow may be unstable if improperly balanced. Detailed theoretical analyses of low (laminar) and high (turbulent) leakage seals are presented along with computer codes, parametric studies, and in particular a simplified PC based code that allows for rapid performance prediction: calculations of stiffness coefficients, temperature and pressure distributions, and leakage rates for parallel and coned face seals. A simplified combined computer code for the performance prediction over the laminar and turbulent ranges of a two phase flow is described and documented. The analyses, results, and computer codes are summarized.

Hughes, William F.↗

Experimental study of external fuel vaporization

The fuel properties used in the design of a flash vaporization system for aircraft gas turbine engines were evaluated in experiments using a flowing system to determine critical temperature and pressure, boiling points, dew points, heat transfer coefficients, deposit formation rates, and deposit removal. Three fuels were included in the experiments: Jet-A, an experimental referree broad specification fuel, and a premium No. 2 diesel fuel. Engine conditions representing a NASA Energy Efficient Engine at sea-level take-off, cruise, and idle were simulated in the vaporization system and it was found that single phase flow was maintained in the heat exchanger and downstream of the throttle. Deposits encountered in the heat exchanger represented a thermal resistance as high as 1300 sq M K/watt and a deposit formation rate over 1000 gC/sq cm hr.

Szetela, E. J.↗

Alternative Liquid DSA Containers for Sludge Slurry Storage in the SRNL Shielded Cells

A pending revision of the Documented Safety Analysis (DSA) for the Savannah River National Laboratory (SRNL) defines “DSA containers'’ for liquid sludge slurries as containers not susceptible to a flashing spray release in a fire and requires that a list of DSA containers be maintained. High Level Waste (HLW) samples are typically received from the Savannah River Site (SRS) tank farm after retrieval from the storage tanks. Glass bottles are preferred for long-term storage of radioactive liquid sludge slurry samples but are not on the DSA container list. An evaluation has been conducted to identify vessel lids for the glass bottles that would vent prior to pressurization and liquid superheating in a fire event. Low melting Field's Metal eutectic alloy with a melting point of 62°C has been identified as a preferred material of construction for vessel lids for this application because the material is resistant to puncture and is expected to have good chemical compatibility and radiation stability in the shielded cells environment. A test vessel was designed to evaluate the alloy and confirm that it would melt before the water in the vessel reaches the boiling point. The tests confirmed: 1) that the reported melting point of the alloy was accurate, 2) that a top fashioned from this material will melt creating an open atmosphere in the vessel headspace prior to sample boiling under moderate and fast heating rates, and 3) that nonuniform heating of the bottle from the bottom also results in melting of the alloy prior to boiling. Based on the results, neither an engulfing fire with standing or toppled bottles or a fire producing localized heat at the vessel bottom would result in flashing spray conditions. It is recommended that glass vessels of various volumes ranging from 125 mL to 1 gallon with modified tops containing the specified Field's Metal eutectic alloy which are appropriately designed to avoid flashing spray material releases be added to the DSA container list. These vessels will be utilized in the Shielded Cells for the storage of radioactive liquid samples of sludge slurries. Use of these vessels will also be advantageous for other liquid samples containing accountable amounts of nuclear material throughout other SRNL laboratories. Similarly constructed paraffin vessel lids could also potentially be added to the approved list, though additional testing would be required.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Alternative Liquid DSA Containers for Sludge Slurry Storage in the SRNL Shielded Cells

A pending revision of the Documented Safety Analysis (DSA) for the Savannah River National Laboratory (SRNL) defines “DSA containers” for liquid sludge slurries as containers not susceptible to a flashing spray release in a fire and requires that a list of DSA containers be maintained. High Level Waste (HLW) samples are typically received from the Savannah River Site (SRS) tank farm after retrieval from the storage tanks. Glass bottles are preferred for long-term storage of radioactive liquid sludge slurry samples but are not on the DSA container list. An evaluation has been conducted to identify vessel lids for the glass bottles that would vent prior to pressurization and liquid superheating in a fire event. Low melting Field’s Metal eutectic alloy with a melting point of 62 °C has been identified as a preferred material of construction for vessel lids for this application because the material is resistant to puncture and is expected to have good chemical compatibility and radiation stability in the shielded cells environment. A test vessel was designed to evaluate the alloy and confirm that it would melt before the water in the vessel reaches the boiling point. The tests confirmed: 1) that the reported melting point of the alloy was accurate, 2) that a top fashioned from this material will melt creating an open atmosphere in the vessel headspace prior to sample boiling under moderate and fast heating rates, and 3) that nonuniform heating of the bottle from the bottom also results in melting of the alloy prior to boiling. Based on the results, neither an engulfing fire with standing or toppled bottles or a fire producing localized heat at the vessel bottom would result in flashing spray conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Sustainable Aviation Fuel via Hydroprocessing of Catalytic Fast Pyrolysis Oil

Cycloalkanes have been identified as a promising alternative for sustainable aviation fuel (SAF) in a recent US Department of Energy Review of Technical Pathways to SAF. Cycloalkanes can provide desirable SAF properties, including energy density, and, in addition, they may be able to provide necessary seal swelling and leakage protection and replace undesirable aromatics in aviation fuel. Catalytic fast pyrolysis (CFP) followed by hydroprocessing constitutes a platform well suited for converting biomass to cycloalkanes. CFP oils are rich in phenolic compounds and, depending on CFP catalyst, in aromatic hydrocarbons, which can both be hydrogenated to form cycloalkanes. In this work, we report results from hydroprocessing of two types of CFP oil to produce fractions boiling in the sustainable aviation fuel range and meeting tested aviation fuel specifications. CFP oils prepared over a zeolite catalyst (ZSM-5) and a hydrodeoxygenation catalyst (Pt/TiO2) were hydroprocessed over a sulfided NiMo/Al2O3 catalyst in a two-stage process (1st stage ~250 degrees C and 2nd stage 385 degrees C) in a continuous trickle-bed hydrotreater. The hydrotreated product contained 39-40% material boiling in the SAF range by distillation with a carbon efficiency of 36-37% from CFP oil to SAF fraction. The SAF fractions consisted of 82-87% of cycloalkanes, had non-detectable oxygen contents and lower heating values (LHV) above the jet fuel minimum limit of 42.8 MJ/kg. The SAF-range product also had acceptable volatility and freeze and flash points per aviation fuel specifications. The results suggest a promising pathway for SAF production via the catalytic fast pyrolysis pathway. Methods to enhance the yield of SAF will be discussed.

BASIC BIOLOGICAL SCIENCES,BIOMASS FUELS↗

Thermal effects in two-phase flow through face seals

When liquid is sealed at high temperature, it flashes inside the seal due to pressure drop and/or viscous heat dissipation. Two-phase seals generally exhibit more erratic behavior than their single phase counterparts. Thermal effects, which are often neglected in single phase seal analyses, play an important role in determining seal behavior under two-phase operation. It is necessary to consider the heat generation due to viscous shear, conduction into the seal rings and convection with the leakage flow. Analytical models developed work reasonably well at the two extremes - for low leakage rates when convection is neglected and for higher leakage rates when conduction is neglected. A preliminary model, known as the Film Coefficient Model, is presented which considers conduction and convection both, and allows continuous boiling over an extended region unlike the previous low-leakage rate model which neglects convection and always forces a discrete boiling interface. Another simplified, semi-analytical model, based on the assumption of isothermal conditions along the seal interafce, has been developed for low leakage rates. The Film Coefficient Model may be used for more accurate and realistic description.

Basu, Prithwish↗

Pool boiling critical heat flux studies of accident tolerant fuel cladding materials

Pool boiling experiments have been performed at atmospheric pressure on potential accident tolerant fuel (ATF) cladding materials (Zirlo®, Cr coated Zirlo®, FeCrAl coated Zirlo®, and monolithic SiC) to evaluate the Critical Heat Flux (CHF) points. Corrosion resistant coatings of Cr and FeCrAl alloy were deposited on flat Zirlo® samples using cold spray technology. The as-prepared samples after uniform surface polishing were subjected to autoclave tests at 360 °C water and 18.6 MPa for 360 h to simulate prototypic corrosion of the ATF cladding materials in LWR normal operation. Surface characteristics potentially influencing CHF such as surface morphology, roughness, static contact angle, and surface chemistry were characterized using a suite of characterization methods including scanning electron microscopy, 3D optical profilometry, optical contact angle measurements, and x-ray photoelectron spectroscopy (XPS). Thermo-physical properties of the samples such as density, thermal conductivity, and heat capacity were measured by differential scanning calorimetry and laser flash thermal diffusivity measurement. FeCrAl coatings showed CHF values comparable to bare Zirlo® samples, while slightly lower CHF values were observed for Cr coated samples and bulk SiC flats (produced by chemical vapor deposition, CVD). As-deposited Cr coatings showed 67% higher CHF than the as-polished Cr coatings due to its higher surface roughness level. The autoclave testing for the prepared samples generally increased the CHF except for the surface polished Cr coatings. Similar CHF values of bare Zirlo®, FeCrAl coating, and CVD SiC samples were observed after autoclave test but there were negligible change CHF of Cr coatings. XPS studies indicated that the formation or deposition of a few monolayers of hydrophobic carbonaceous species on surface can affect CHF values. The trends in CHF data are discussed in terms of evolution of the surface characteristics of the ATF materials.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Numerical Modeling of No Vent Filling of a Cryogenic Tank with Thermo-dynamic Vent System Assisted Injector

This paper presents a multi-node finite volume model of No Vent Filling (NVF) of a cryogenic tank with Thermo-dynamic Vent System (TVS) assisted injector, using the Generalized Fluid System Simulation Program (GFSSP), a general purpose flow network code. NVF tests were conducted in a CRYOgenic Orbital Testbed (CRYOTE) tank which was filled by liquid nitrogen using a TVS assisted injector with vent valve closed during the entire filling process. In TVS assisted injector, the liquid flow splits into two streams: one stream is routed to a Joule-Thomson (J-T) orifice where the flow immediately flashes from liquid to vapor or two phase mixture because the downstream to J-T leg is maintained at vacuum level.; the other stream is injected into the tank after being cooled by cold vapor of J-T leg in a heat exchanger. The flow through J-T leg is also used to cool the outer metal matrix of the injector which in turn cools the vapor in the tank ullage. The cooling of vapor in the ullage by cold injector surface reduces ullage pressure that allows liquid to enter and fill the tank. An integrated numerical model of the test set up was developed. The model included the dual lines of TVS assisted injector, tank and tank wall. The tank was discretized into multiple fluid nodes and branches to represent the ullage and liquid nitrogen and multiple solid nodes to represent the tank wall and structure. The heat transfer between solid to fluid was calculated from pool boiling correlations which include film, transition, and nucleate boiling, as well as natural convection during pre- and post-boiling. The model also accounts for the condensation of vapor at ullage-injector interface and when it comes in contact with the liquid spray. The predicted pressure, resident mass, wall temperature in the tank were compared with the test data.

Alok Majumdar↗

Reducing roughness and improving efficiency of MAPbI3 perovskite solar cells made by high-throughput photonic curing

For perovskite solar cells (PSCs) to be commercially viable, the slow and energy-insufficient thermal annealing step must be eliminated. Among the photo-irradiation methods proposed to replace thermal annealing, photonic curing is the fastest conversion method. Photonic curing delivers short (20 μs to 100 ms) but intense light pulses from a broadband (200-1500 nm) xenon flash lamp, making it the only method to convert perovskite under 20 ms. This processing time can be extrapolated to a roll-to-roll web speed of 40 m/min based on laboratory processing conditions. However, most reported PSCs made by photonic curing under 1 second have inferior performance (~10% PCE). Although SEM images show dense and pinhole-free perovskite films, AFM images indicate secondary wavy features of 500 nm-wide ridge and 80 nm-deep trenches on photonically cured perovskite films, the existence of which correlates with poor device performance. We suggest that this morphology feature is produced by volatile solvent evaporation during the fast photonic curing process. Two approaches have been made to remedy this issue: (1) adding CH2I2 as the third solvent in the conventional DMF-DMSO system and (2) applying a controlled air-blowing step before photonic curing to remove excess solvent further. Combining these two approaches produces photonically- cured perovskite films with a comparable film roughness and device performance. Alkyl halide additives have been reported to enhance PSC performance by modulated solvent-solute interactions and C-X (X = Cl, Br, and I) cleavage. Photonic curing can cleave CH2I2, producing disassociated iodide ions to replenish iodine loss induced by photonic curing, which is confirmed by EDX. As a co-solvent, the high boiling point of CH2I2 can also make the solvent less volatile, reducing surface roughness in photonically cured perovskite films. Additionally, photonically-cured perovskite films have longer PL lifetimes and a higher recombination resistance compared to thermally-annealed counterparts. As a result, we demonstrate that photonic curing is a suitable method to replace thermal annealing in high-throughput PSC fabrication.

14 SOLAR ENERGY↗