Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fixed grid”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Grid Architecture Mapping to Understand Transformation (GAMUT): Methods and Framework Architecture

Grid architecture (GA) is a concept that was developed to address the need for a comprehensive view of power grid challenges. GA can be viewed as a relatively consistent and fixed high-level approach; however, for any instantiation of grid structures, a combinatorial explosion results from each lower-layer expansion. This constitutes the main challenge with GA—it is a grid architect’s view of the system, which might not be very informative at the implementation level. Grid Architecture Mapping to Understand Transformation (GAMUT project) seeks to bridge that gap by integrating subject matter expertise across GA structures, providing users who lack expertise in GA approaches with valuable insights and informational materials. GAMUT seeks to answer feasibility questions for the approach. System-level expectations are that a GA baseline needs to be established in order for GA to be the common framework to which any lower layer approach is tied. This report explores a potential information ingestion and documentation framework to support GAMUT. The main concepts that enable the solution domain of GAMUT are discussed, and examples are provided. The solution domain leverages already-existing technology and concepts related to GA, knowledge management, and other relevant areas. To assess GAMUT building blocks and the overall approach, a feasibility assessment is proposed, rooted in systems engineering and GA architecture evaluation concepts.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Energy Exascale Earth System Model v2.0.2

Second patch release of v2.0.0 Changes since v2.0.1 [Important change] Add and update SSP370 and SSP585 cases, add tests, fix use-case files, Change ocean and sea-ice IC for ARRM60to10. [EAM] allow thetaxx as a CAM_TARGET, enable northamericax4v1pg2_WC14to60E2r3 for AMIP, fix ndrop initialization, allow up to 15 history files. [EAMxx] allow use of readnl [EAM-MMF] allow transient SST case for C++ MMF, remove specific task/thread count for ESMT test, modify the variance transport diagnostic, reorg tests, [HOMME] Allow optional sponge layer. [ELM] add 2 land-atm compsets, update FATES to API 17.0.0, allow FATES sp mode, allow ELM harvest to drive FATES harvest, fix memleaks, reduce test build times, modified parameters for miscanthus and switchgrass based on calibration [MPAS-Ocean] turn on ocean BGC in BGC cases, fix interface locations for 60L PHC grid, add mode spec to conservation check streams, allow oRRS18to6v3 grid to run with JRA, update ocean and sea ice ICs for ARRM60to10 (needed for v2), GPU port of thickness tendency, add CMPASO-JRA1p4, [MPAS framework] Add new reproducible global sum module for MPAS components, Add mostRecentAccessTime attribute to streams [MPAS-landice] Update MALI version and Greenland mesh [MPAS-seaice] add single-cell test case, fix BGC restart, Adds omp critical directives for ice warnings seen on cori. [CIME] Fix component namelist creation bugs when NINST>1, add OpenACC, OpenMP and CXX GPU tests, fix nonBFB tests, stop using config_compilers, reduce ELM test build times with shared executable, update OpenMPI on Chrysalis. fix baseline handling, provenance handling with update to cime6.0.33, also use component-specific config_pes files and add the ones from master [Machine updates] cori modules after maint, Chrysalis to OpenMPI-4.1.3 [run_e3sm] replace default case name and group. [Externals] update SCORPIO to 1.3.2

ECP↗

Energy Exascale Earth System Model v2.1.0

First release of version 2.1 of the Energy Exascale Earth System Model. [ATM] The atmosphere component remains EAM. There are no major changes in the default configuration since 2.0. New features include: A semi-lagrangian tracer transport for theta-l dycore, a new algorithm for finding the tropopause, new RRM mesh configurations. Add and update SSP370 and SSP585 cases. Restore the FIDEAL case. [LAND] The land component is ELM. There are no major changes in the default configuration since 2.0. Several option features have been added including: implementation of topography-based subgrid structure (topounits) and accompanying parameterizations and atmospheric forcing downscaling methods; a new plant hydraulics scheme; two-way land-river hydrological coupling through the infiltration of floodplain water; an implementation of perennial crops; updates to the SNICAR-AD snow radiative transfer model; and implementation of soil erosion and sediment yield in ELM-Erosion. Each of these new changes is modular in design and can be turned on or off as the user specifies; they are currently being tested in different “BGC” configurations. [OCEAN] The ocean component remains MPAS-Ocean. Major change since version 2.0 include the addition of the Fox-Kemper et al. 2011 parameterization for submesocale eddies, a correction for barotropic thickness consistency that reduces divergence noise, and the addition of an ocean carbon conservation analysis member. [SEAICE] The sea-ice component remains MPAS-Seaice. Major changes since version 2.0 include: A correction to how shortwave parameters are interpolated in the snicar-ad 5-band radiation scheme, the addition of a sea ice carbon conservation analysis member, updates to the default sea ice biogeochemistry namelist parameters to be consistent with version 2.0 improvements to nitrogen cycling and a correction in the ice-ocean dissolved organic nitrogen coupling. [LAND ICE] The land-ice component remains MPAS-Albany-landIce (MALI). Major changes since 2.0 include an update to the MALI version and the Greenland mesh.[RIVER] The river model is MOSART. There are no major changes in the default configuration since 2.0. A major new optional feature is two-way river-ocean hydrological coupling between MOSART and MPAS-O. This change can be turned on or off as the user specifies, and is being tested in different configurations. [COUPLER] The coupler remains cpl7/MCT. Major changes since version 2.0 include: Carbon budget calculated when heat/water budgets active. Fix a bug in land-atm fluxes for tri-grid configurations. [OTHER] a small bug in the zenith angle calculation was fixed in the data models.

ECP↗

Expert perspectives on the wind plant of the future

Abstract Wind power technology has changed rapidly in recent years. Technology innovation, evolving power markets, and competing land and ocean uses continue to influence the design and operation of wind turbines and plants. Anticipating these trends and their impact on future facilities can inform commercial strategies and research priorities. Drawing from a recent survey of 140 of the world's foremost wind experts, we identify expectations of future wind plant design in 2035, both for onshore and offshore wind. Experts anticipate continued growth in turbine size, to 5.5 (onshore) and 17 MW (offshore), with plants located in increasingly less favorable wind and siting regimes. They expect plant sizes of 1,100 MW for fixed‐bottom and 600 MW for floating offshore wind. Experts forecast enhanced grid‐system value from wind through significant to widespread use of larger rotors, hybrid projects with batteries and hydrogen production, and more. To explain experts' perspectives on future plant design and operation, we identify five mechanisms: economies of unit, plant, and resource scale; grid‐system value economies; and production efficiencies. We characterize learning effects as a moderating influence on the strength of these mechanisms. In combination, experts predict that these design choices support levelized cost of energy reductions of 27% (onshore) and 17%–35% (floating and fixed‐bottom offshore) by 2035 compared to today, while enhancing wind energy's grid service offerings. Our findings provide a much‐needed benchmark for representing future wind technologies in power sector models and address a critical research gap by explaining the economics behind wind energy design choices.

17 WIND ENERGY↗

Quantum computation of SU(2) lattice gauge theory with continuous variables

We present a quantum computational framework for pure SU(2) lattice gauge theory, using continuous variables instead of discrete qubits to represent the infinite-dimensional Hilbert space of the gauge fields. We consider a ladder as well as a two-dimensional grid of plaquettes, detailing the use of gauge fixing to reduce the degrees of freedom and simplify the Hamiltonian. We demonstrate how system dynamics, ground states, and energy gaps can be computed using the continuous-variable approach to quantum computing. Our results indicate that it is feasible to study non-Abelian gauge theories with continuous variables, providing new avenues for understanding the real-time dynamics of quantum field theories.

Gauge Symmetry↗

An Assessment of Deploying Advanced Pumped Storage Hydropower Technology in U.S. Electricity Markets

Pumped storage hydropower (PSH) is a type of hydropower technology where energy can be stored and generated by moving water between two reservoirs of differing elevations. In addition to providing 97% of the total utility-scale hydropower storage in the United States, PSH plants have operational characteristics - such as high ramp rates and the ability to provide reserves - that contribute to greater flexibility and reliability of the power grid. New PSH technologies can provide additional flexibility beyond existing, fixed-speed units. With the emergence of high levels of variable renewable energy resources (e.g., wind and solar), energy storage is expected to be crucial to the reliability and reliance of the power grid in a low-carbon future. At diurnal and longer durations, PSH plants have some of the lowest costs per unit of energy, have been proven to be reliable and efficient, are not cycle-limited, and typically have long lives, often exceeding 50 years. The work presented here focuses on a new generation of PSH: ternary PSH and quaternary PSH (together referred to as T/Q-PSH). Given recent experience in Europe, grid operators in the United States and elsewhere are increasingly focusing their attention on T/Q-PSH as a proven, financeable technology that can offer utility-scale, long-duration, fast-acting energy storage capabilities and grid services. T/Q-PSH differs from conventional PSH in that it can provide fast-response ancillary services during both generating and pumping operations. This capability together with fast mode switching times are key attributes that make T/Q-PSH technologies attractive for managing and stabilizing electricity systems with high amounts of variable renewable energy.

ENERGY PLANNING, POLICY, AND ECONOMY,HYDRO ENERGY↗

A Particle-in-Cell Method for Plasmas with a Generalized Momentum Formulation, Part I: Model Formulation

Here, this paper formulates a new particle-in-cell method for the Vlasov–Maxwell system. Under the Lorenz gauge condition, Maxwell’s equations for the electromagnetic fields can be written as a collection of scalar and vector wave equations. The use of potentials for the fields motivates the adoption of a Hamiltonian formulation for particles that employs the generalized (conjugate) momentum. A notable advantage offered by the Hamiltonian formulation is the elimination of time derivatives in the Lorenz gauge formulation that are required by the standard Newton–Lorentz treatment of the particles. This allows the fields to retain the full time-accuracy guaranteed by the field solver. The resulting updates for particles require only knowledge of the fields and their spatial derivatives. An analytical method for constructing these spatial derivatives is presented that exploits the underlying integral solution used in the field solver for the wave equations. Moreover, these derivatives are demonstrated to converge at the same rate as the fields in both time and space. The Method of Lines Transpose field solver we consider in this work is globally first-order accurate in time and high-order accurate in space (e.g., fourth- and fifth-order) and belongs to a larger class of methods which are unconditionally stable, can address geometry, and leverage $\mathcal {O}(N)$ fast summation methods for efficiency. We demonstrate the method on several well-established benchmark problems on bounded domains, including a plasma sheath as well as a relativistic particle beam. The efficacy of the proposed formulation is established by comparing with a second-order accurate finite-difference time-domain method that employs a leapfrog time advance for particles and a charge conserving map suitable for bounded domains. The new method shows mesh-independent numerical heating properties even in cases where the plasma Debye length is smaller than the grid spacing. This is an important feature of the new method for problems defined on bounded domains, because it permits the use of coarser grids in space in the representation of the fields. Such a capability has significant implications for the simulation of plasmas in bounded domains with complex geometry, where the ratio between the largest and smallest cells can vary significantly. The use of high-order spatial approximations in the new method also means that fewer grid points are required in order to achieve a fixed accuracy. Our results also suggest that the new method can be used with fewer simulation particles per cell compared to the benchmark explicit method, which permits further computational savings.

97 MATHEMATICS AND COMPUTING↗

Optimal electric-distribution-grid planning considering the demand-side flexibility of thermal building systems for a test case in Singapore

The planning of district-scale electric grids, i.e., distribution grids, has traditionally relied on finding the most cost-effective design such that they are able to supply the peak loads in a district. With the advent of electric demand side flexibility (DSF), there is the opportunity to reshape peak loads such that the investment cost of the electric grid decreases in exchange for a minor increase in the operation cost. This paper formulates an optimal planning approach for the electric grid at the district scale, which incorporates the DSF from thermal building systems, e.g., heating ventilation and air-conditioning (HVAC) systems. The problem is formulated as a mixed-integer linear program (MILP) and aims at minimizing the investment cost for the grid along with the operation cost of the flexible loads. This is subjected to the fixed electricity demand and thermal comfort constraints of building occupants. To this end, linear models for the thermal comfort in the buildings and the power flow in electric grid are considered. The approach is tested on a district planning test case based in Singapore, where the results show up to 30.9 % reductions in investment cost and up to 3.7 % reduction in total annualized cost. Urban planning authorities, developers and utility companies can all benefit from the presented approach to make optimized investment decisions. For building operators, the results point to the need of adopting their control systems for DSF.

Troitzsch, Sebastian↗

Modeling simultaneous particle shrinkage, dissolution and breakage using the modified moving grid technique

Simultaneous shrinkage, dissolution and breakage are important particle size reduction phenomena that characterize processes like the reactive degradation of solid chemicals. The dynamics of the particle size distribution (PSD) for such processes are non-trivial to model due to the number expending processes brought about by the eventual dissolution of particles. To this end, Population Balance Model (PBM) resolved through the sectional techniques is the natural approach. Here, we introduce a modified Moving Grid technique (m-MGT) to accurately resolve the particle size reduction phenomena. Our technique mimics the perpetual particle shrinkage through a continuously left-moving size grid and incorporates a strategic grid removal routine to capture the disappearance of particles. Coupled with the Fixed Pivot (FP) discretization for breakage, our m-MGT not only preserves the moment-related properties, but also benchmarked very well against the analytical number densities and exhibited a minimum of first-order convergence in all assessed case studies.

97 MATHEMATICS AND COMPUTING↗

Simulink Modeling and Dynamic Study of Fixed-Speed, Variable-Speed, and Ternary Pumped Storage Hydropower

Pumped Storage Hydropower (PSH) is one of the most popular energy storage technologies in the world. It uses an upper reservoir to store water which can be later used during high-demand. In the United States, most of the energy storage capability actually corresponds to PSH. Moreover, PSH also brings multiple benefits to grid operation. This report presents the Simulink models of three common PSH technologies: Fixed-Speed (FS), Variable-Speed (VS), and Ternary (T)-PSH. These models are available to the general public on this GitHub repository, which contains the MATLAB model initialization files, the Simulink model files, and supplementary MATLAB code used to obtain the figures in this work. For each PSH model, an introductory description of the model components and other relevant functionalities are provided. For further information regarding the models and the initialization parameters, the reader is referred to the shared files in the repository. This report also presents the dynamic behavior of each model. The response of such models to a load event is analyzed and matched with each model's features. A custom IEEE 39 bus case is employed for the FS and T-PSH simulations, while the VS-PSH is simulated on a simplified three-bus test system due to the computational complexity of the model. For the T-PSH, the steady-state and the switching between several operating modes are also studied in this work.

13 HYDRO ENERGY↗

Grid-Ready Flexible Transformers for Resilient Transmission Networks

Today’s transmission networks extend for hundreds of kilometers, transferring significant amounts of electrical energy. For every country, there are sort of “back- bone” lines, where a massive failure of transformers would create serious challenges to sustain a reliable energy supply. Natural phenomena and human driven actions could be triggers of such catastrophic events. For large utilities, or groups of utilities, it would be highly convenient to count with “flexible transformers”, which could be used as replacements for different voltage levels and with impedance adjustable to match optimum local requirements of impacted substations. Currently applied “emergency transformers” are fixed-impedance devices. In this contribution, a new concept of flexible, “future-grid ready” type of power transformers, specially devised for transmission networks is explained. This transformer has adjustable impedance features, which could be on-line operated. The concept has been proven to be functional and stable in the factory lab and in the field, by means of a prototype autotransformer of of 100 MVA, 165/69 Kv.

impedance of transformers↗

Adaptation of virtual synchronous generators to dynamic conditions in power grids

Virtual synchronous generators (VSGs) are widely adopted as grid-forming controls for inverter-based resources. However, when grid conditions vary significantly as characterized by changes in short-circuit ratio (SCR) and the reactance-to-resistance (X/R) ratio, fixed-gain designs and the commonly used P–Q decoupling assumption can become inaccurate. Such conditions can degrade transient power performance, leading to oscillations, prolonged settling, and overshoot, particularly in stiff-grid operating points. This paper quantifies how grid strength and impedance-dependent coupling affect the active–reactive power dynamics of a conventional VSG over a broad range of SCR and X/R values. An adaptive VSG tuning framework is then developed by combining (i) a coupling-explicit, impedance-parameterized state-space model to enable systematic controller synthesis, (ii) a full-state-feedback law designed via pole placement to meet prescribed damping and settling-time specifications, and (iii) a physics-informed neural network (PINN)–based online grid-impedance estimator that updates controller gains in real time as grid conditions vary. Offline simulations in MATLAB/Simulink and real-time validation on an OPAL-RT platform show that the proposed method preserves consistent damping and settling behavior with reduced overshoot across wide SCR and X/R ranges, compared with fixed-gain VSG baselines.

Adaptive control↗

Single Grid Error Estimation for Neutron Transport Solvers

The method of nearby problems (MNP) is a solution verification technique that does not require the use of multiple spatial grids. To estimate spatial discretization error without requiring a high-fidelity spatial grid, an analytical curve fit is interpolated from the numerical solution. The residual between the curve fit solution and numerical solution is calculated and added as an additional source term to the governing equation. The nearby solution is estimated using the updated source term and boundary conditions to remain consistent with the curve fit interpolation. The nearby solution can be compared to the curve fit solution as a discretization error estimation while using a single spatial grid. Without the use of higher fidelity spatial grids, the MNP is able to approximate the spatial discretization error, a facet of solution verification. The application of the method of nearby problems is presented for one- and two-dimensional neutron transport problems for both fixed source and criticality problems on the spatial variable. The fixed source results demonstrate the effectiveness of nearby problems for spatial error identification using the discrete ordinates method. Criticality results are shown to identify area of high spatial error for the C5G7 problem as well as for the discrete ordinates solver. A novel approach of combining the capabilities of Monte Carlo with the discrete ordinates nearby problems is presented for one- and two-dimensional fixed source problems. In conclusion, the MNP demonstrates its effectiveness at identifying spatial error on a single structured grid with a wide variety of neutron transport problems.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Direct Power Control of Back to Back Modular Multilevel Converter with Advanced Grid Support Functions for Grid Forming Application

Possibility of using back-to-back modular multilevel converter system with a direct power control architecture has been investigated in this paper. The rectifier side is controlled to be in grid following mode whereas the inverter side is controlled in grid forming mode. Both the sides’ local controllers use Lyapunov energy function based architecture to accomplish the objective of active and reactive power control as well as maintaining a fixed user defined voltage over the dc bus on the rectifier side. Therefore, the proposed direct power control architecture has embedded dc bus control architecture to maintain fixed user defined value of the capacitors. Similar architecture is implemented on the inverter side to accomplish either voltage control during grid forming or power control during grid following. Advanced grid support functionalities based on IEEE-1547-2018 is implemented and utilized to generate the reference values for either the rectifier or the inverter sides. The overall system is modeled based on MATLAB/Simulink and PLECS domain and various important case studies to verify the efficacy of the overall system has been presented.

direct power control (DPC)↗

Asymptotically compatible reproducing kernel collocation and meshfree integration for the peridynamic Navier equation

Here, we study reproducing kernel (RK) collocation method for peridynamic Navier equation. In the first part, we apply a linear RK approximation to both displacement and dilatation, and then back-substitute dilatation and solve the peridynamic Navier equation in a pure displacement form. The RK collocation scheme converges to the nonlocal limit for a fixed nonlocal interaction length and also to the local limit as nonlocal interactions vanish. The stability is shown by comparing the collocation scheme with the standard Galerkin scheme using Fourier analysis. In the second part, we apply the RK collocation to the quasi-discrete peridynamic Navier equation and show its convergence to the correct local limit when the ratio between the nonlocal length scale and the discretization parameter is fixed. The analysis is carried out on a special family of rectilinear Cartesian grids for the RK collocation method with a designated kernel with finite support. We assume the Lamé parameters satisfy λ ≥ μ to avoid extra assumptions on the nonlocal kernel. Finally, numerical experiments are conducted to validate the theoretical results.

42 ENGINEERING↗

Limiter-aware adaptive excitation control for hydropower generators with legacy voltage regulation systems

Hydropower units often rely on legacy excitation systems with fixed automatic voltage regulator (AVR) settings, but parameter drift, changing operating conditions, and evolving grid-service demands can degrade terminal-voltage regulation over time. This problem should be addressed because poor voltage regulation affects reactive-power support, system stability, and reliable plant operation, and replacing installed AVR and limiter logic is costly and disruptive in practice. To address this issue, this paper proposes a retrofit-friendly enhancement for hydropower generator excitation systems that combines adaptive tuning of the AVR middle lead–lag branch with a small proportional-integral correction for removing steady bias and slow drift. The adaptive laws are normalized, projection-bounded, and equipped with leakage, while adaptation is enabled only in the middle branch. Thus, the intent of the underexcitation and overexcitation limiters, as well as legacy current and rate limits, remains unchanged. Stability is analyzed under incremental performance assumptions, yielding boundedness and asymptotic tracking in the absence of saturation. The method is evaluated using real operational data from a utility-scale hydropower unit at Rocky Reach Dam, Unit C-8. Compared with the fixed AVR baseline, the proposed method reduces terminal-voltage mean squared error by about 70%, removes long periods of steady-state bias, and improves transient tracking while coexisting with limiter actions. These results show that substantial voltage-control improvement can be achieved on existing hydropower units with minimal integration effort and without replacing the installed AVR structure.

ESST5B model↗

Great Lakes Wind Energy Challenges and Opportunities Assessment

Many issues associated with wind development in the Great Lakes will require solutions different from those developed for offshore wind in ocean states and may not fully benefit from the industry learnings of nearby states. As a result, technology readiness and cost reduction for Great Lakes Wind (GLW) energy generation is likely to be delayed relative to other regions without a substantial, targeted GLW research campaign, and proactive stakeholder engagement in the region at all levels. Failure to conduct the necessary research to lower GLW costs in the near term could limit its contribution to the Nation's decarbonization goals by 2035, and could potentially raise long term energy prices in Great Lakes states if demand for renewable energy continues to accelerate. The overall objective of a research program such as that described in this report would be to enable the realization of commercial GLW before 2035. With the aim of ensuring that prospective development of GLW is conducted efficiently, safely, and coordinated in the best interests of the local residents and stakeholders, the U.S. Department of Energy (DOE) Wind Energy Technologies Office (WETO) tasked the National Renewable Energy Laboratory (NREL) to assist in (a) developing an improved understanding of offshore wind power's development potential in the Great Lakes, (b) identifying the key issues that need to be resolved for this potential to be achieved, and (c) defining a comprehensive research program to address and resolve these issues. This report presents the results of NREL's effort to address these needs.

cost modeling↗

Networked Microgrids Optimization

This project is mainly about the operation optimization of three networked microgrids (MG), including centralized optimization and distributed optimization. The alternating direction method of multipliers (ADMM) algorithm is used for distributed optimization. In the distribution network considered here, there is a Distribution Management system (DMS) as the system coordinator and several networked microgrids. In grid-connected mode, power could be imported or exported at the distribution substation bus according to the utility rate, and the exchanged power at point of common coupling (PCC) of any microgrid has a limitation. In islanded mode, the power imports/exports at the distribution substation are zero. In both grid-connected and islanded mode, the distribution substation is taken as a slack bus with fixed voltage magnitude.

Chen, Yang [Oak Ridge National Laboratory (ORNL), ↗