Engineering PapersSearch

SEARCH · Engineering Papers

Results for “Fixed frequency tests”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Transonic shock-induced dynamics of a flexible wing with a thick circular-arc airfoil

A simple flexible wing model with an 18-percent circular arc airfoil was constructed and tested in the Langley Transonic Dynamics Tunnel to investigate the dynamic characteristics that a wing might have under these conditions. In the region of shock-boundary layer oscillations, buffeting of the first bending mode was obtained. This mode was well separated in frequency from the shock boundary layer oscillations. A limit cycle oscillation was also measured in a 'third bending-like' mode, involving wing vertical bending and splitter plate motion, which was in the frequency range of the shock-boundary layer oscillations. Several model configurations were tested, and a few potential fixes were investigated.

Bennett, Robert M.

Fixed Base Modal Survey of the MPCV Orion European Service Module Structural Test Article

Recently, the MPCV Orion European Service Module Structural Test Article (E-STA) underwent sine vibration testing using the multi-axis shaker system at NASA GRC Plum Brook Station Mechanical Vibration Facility (MVF). An innovative approach using measured constraint shapes at the interface of E-STA to the MVF allowed high-quality fixed base modal parameters of the E-STA to be extracted, which have been used to update the E-STA finite element model (FEM), without the need for a traditional fixed base modal survey. This innovative approach provided considerable program cost and test schedule savings. This paper documents this modal survey, which includes the modal pretest analysis sensor selection, the fixed base methodology using measured constraint shapes as virtual references and measured frequency response functions, and post-survey comparison between measured and analysis fixed base modal parameters.

modal testing

Low-Frequency Suspension System For Large Space Structures

Simple system enables vibration testing of space structures on ground. Suspension system includes number of suspension stations attached by cables to space structure (such as truss beam) along its length. Suspension stations fixed to ceiling or other rigid support. Disk and cable adjustments lower frequency of oscillatory motion of suspension system to enable accurate measurements of frequencies of vibration of space structure. Designed to alleviate coupling between suspension system and torsional vibrational modes of structure.

Reed, Wilmer H., III

Multifunction tests of a frequency domain based flutter suppression system

This paper describes the process of analysis, design, digital implementation and subsonic testing of an active controls flutter suppression system for a full span, free-to-roll wind-tunnel model of an advanced fighter concept. The design technique employed a frequency domain representation of the plant and used optimization techniques to generate a robust multi-input/multi-output controller. During testing in a fixed-in-roll configuration, simultaneous suppression of both symmetric and antisymmetric flutter was successfully demonstrated. For a free-to-roll configuration, symmetric flutter was suppressed to the limit of the tunnel test envelope. During aggressive rolling maneuvers above the open-loop flutter boundary, simultaneous flutter suppression and maneuver load control were demonstrated. Finally, the flutter suppression controller was reoptimized overnight during the test using combined experimental and analytical frequency domain data, resulting in improved stability robustness.

Christhilf, David M.

Treatment of atomic and molecular line blanketing by opacity sampling

A sampling technique for treating the radiative opacity of large numbers of atomic and molecular lines in cool stellar atmospheres is subjected to several tests. In this opacity sampling (OS) technique, the global opacity is sampled at only a selected set of frequencies, and at each of these frequencies the total monochromatic opacity is obtained by summing the contribution of every relevant atomic and molecular line. In accord with previous results, we find that the structure of atmospheric models is accurately fixed by the use of 1000 frequency points, and 100 frequency points are adequate for many purposes. The effects of atomic and molecular lines are separately studied. A test model computed using the OS method agrees very well with a model having identical atmospheric parameters, but computed with the giant line (opacity distribution function) method.

Johnson, H. R.

Testing of 30-GHz low noise receivers

NASA-sponsored studies of the growth in communications traffic have indicated that the frequency spectrum allocated to fix-service satellites at the C and Ku bands will reach saturation by the early 1990's. The next higher frequency bands allocated for communications satellties are 27.5 to 30 GHz for the uplink and 17.7 to 20.2 GHz for the downlink. Current plans for developing satellite systems that use these bands include a NASA demonstration satellite (ACTS). One of the components identified as critical to the success of that mission is a 27.5 to 30 GHz satellite receiver. In response to that identification, NASA has sponsored the development of such a receiver to the proof-of-concept (POC) level. Design and fabrication of such POC model receivers was carried out under parallel contracts awarded to LNR Communications, Inc. of Hauppauge, New York and to ITT Defense Communications Division of Nutley, New Jersey. The most significant of the performance goals were a 5 db maximum noise figure, a 2.5 GHz passband, and e0 dB Rf to If gain. Following delivery of hardware from each of the contractors, an in-house test program was undertaken at NASA's Lewis Research Center in order to verify the contractor-reported performance and to provide a comparison of the two receivers under identical test conditions. The present paper reports the results of those tests.

Conroy, M. J.

Testing of 30-GHz low noise receivers

NASA-sponsored studies of the growth in communications traffic have indicated that the frequency spectrum allocated to fix-service satellites at the C and Ku bands will reach saturation by the early 1990's. The next higher frequency bands allocated for communications satellites are 27.5 to 30 GHz for the uplink and 17.7 to 20.2 GHz for the downlink. Current plans for developing satellite systems that use these bands include a NASA demonstration satellite (ACTS). One of the components identified as critical to the success of that mission is a 27.5 to 30 GHz satellite receiver. In response to that identification, NASA has sponsored the development of such a receiver to the proof-of-concept (POC) level. Design and fabrication of such POC model receivers was carried out under parallel contracts awarded to LNR Communications, Inc. of Hauppauge, New York and to ITT Defense Communications Division of Nutley, New Jersey. The most significant of the performance goals were a 5 dB maximum noise figure, a 2.5 GHz passband, and 20 dB RF to IF gain. Following delivery of hardware from each of the contractors, an in-house test program was undertaken at NASA's Lewis Research Center in order to verify the contractor-reported performance and to provide a comparison of the two receivers under identical test conditions. The present paper reports the results of those tests.

Conroy, M. J.

Feasibility Study to Extract Artemis-1 Fixed Base Modes While Mounted on a Dynamically Active Mobile Launch Platform

There are several challenges associated with the scheduled integrated modal test (IMT)of the Space Launch System (SLS) Artemis-1flight vehicle mounted on the mobile launcher (ML). While the goal of the test is to characterize the Artemis-1, the inclusion of the ML as the support stand for the test means that the entire system must be well characterized. A considerable amount of effort and schedule will have to be devoted to understanding both the test stand (the ML) and the Artemis-1 flight vehicle, and there is a risk that the effort may not be completed in time for a successful launch. NASA has requested that alternative methods be investigated to generate test results that can remove the effects of the ML from the test. ATA Engineering, Inc., (ATA)was given a reduced model f theArtemis-1 flight vehicle’s IMT configuration containing the candidate set of accelerometers and interface degrees of freedom (DOF). The model was used to determine how well ATA’s fixed base correction technique is able to estimate fixed base modes from test data collected on the IMT. This paper presents the fixed base correction method results.

modal testing

A Study of Longitudinal Control Problems at Low and Negative Damping and Stability with Emphasis on Effects of Motion Cues

As part of a general investigation to determine the effects of simulator motions on pilot opinion and task performance over a wide range of vehicle longitudinal dynamics, a cooperative NASA-AMAL program was conducted on the centrifuge at Johnsville, Pennsylvania. The test parameters and measurements for this program duplicated those of earlier studies made at Ames Research Center with a variable-stability airplane and with a pitch-roll chair flight simulator. Particular emphasis was placed on the minimum basic damping and stability the pilots would accept and on the minimum dynamics they considered controllable in the event of stability-augmentation system failure. Results of the centrifuge-simulator program indicated that small positive damping was required by the pilots over most of the frequency range covered for configurations rated acceptable for emergency conditions only (e.g., failure of a pitch damper). It was shown that the pilot's tolerance for unstable dynamics was dependent primarily on the value of damping. For configurations rated acceptable for emergency operation only, the allowable instability and damping corresponded to a divergence time to double amplitude of about 1 second. Comparisons were made of centrifuge, pitch-chair and fixed-cockpit simulator tests with flight tests. Pilot ratings indicated that the effects of incomplete or spurious motion cues provided by these three modes of simulation were important only for high-frequency, lightly damped dynamics or unstable, moderately damped dynamics. The pitch- chair simulation, which provided accurate angular-acceleration cues to the pilot, compared most favorably with flight. For the centrifuge simulation, which furnished accurate normal accelerations but spurious pitching and longitudinal accelerations, there was a deterioration of pilots' opinion relative to flight results. Results of simulator studies with an analog pilot replacing the human pilot illustrated the adaptive capability of human pilots in coping with the wide range of vehicle dynamics and the control problems covered in this study. It was shown that pilot-response characteristics, deduced by the analog-pilot method, could be related to pilot opinion. Possible application of these results for predicting flight-control problems was illustrated by means of an example control-problem analysis. The results of a brief evaluation of a pencil-type side-arm controller in the centrifuge showed a considerable improvement in the pilots' ability to cope with high-frequency, low-damping dynamics, compared to results obtained with the center stick. This improvement with the pencil controller was attributed primarily to a marked reduction in the adverse effects of large and exaggerated pitching and longitudinal accelerations on pilot control precision.

Sadoff, Melvin

Development of monofilar rotor hub vibration absorber

A design and ground test program was conducted to study the performance of the monofilar absorber for vibration reduction on a four-bladed helicopter. A monofilar is a centrifugal tuned two degree-of-freedom rotor hub absorber that provides force attenuation at two frequencies using the same dynamic mass. Linear and non-linear analyses of the coupled monofilar/airframe system were developed to study tuning and attenuation characteristics. Based on the analysis, a design was fabricated and impact bench tests verified the calculated non-rotating natural frequencies and mode shapes. Performance characteristics were measured using a rotating absorber test facility. These tests showed significant attenuation of fixed-system 4P hub motions due to 3P inplane rotating-system hub forces. In addition, detuning effects of the 3P monofilar modal response were small due to the nonlinearities and tuning pin slippage. However, attenuation of 4P hub motions due to 5P inplane hub forces was poor. The performance of the 5P monofilar modal response was degraded by torsional motion of the dynamic mass relative to the support arm which resulted in binding of the dynamic components. Analytical design studies were performed to evaluate this torsional motion problem. An alternative design is proposed which may alleviate the torsional motion of the dynamic mass.

Duh, J.

NASA Engineering and Safety Center Technical Bulletin No. 22-04: Uncertainty Quantification of Reduced Order Structural Dynamic Models

Uncertainty quantification (UQ) provides statistical bounds on prediction accuracy based on finite element model (FEM) uncertainty. An alternate method for UQ, called the Hybrid Parametric Variation (HPV) combines a parametric variation of the Hurty/Craig-Bampton (HCB) fixed-interface (FI) modal frequencies with a nonparametric variation (NPV) method. This provides a UQ method that can be traced to test data, which can be updated as additional data and improved correlated models become available.

Uncertainty Quantification

The application of digital computers to near-real-time processing of flutter test data

Procedures used in monitoring, analyzing, and displaying flight and ground flutter test data are presented. These procedures include three digital computer programs developed to process structural response data in near real time. Qualitative and quantitative modal stability data are derived from time history response data resulting from rapid sinusoidal frequency sweep forcing functions, tuned-mode quick stops, and pilot induced control pulses. The techniques have been applied to both fixed and rotary wing aircraft, during flight, whirl tower rotor systems tests, and wind tunnel flutter model tests. An hydraulically driven oscillatory aerodynamic vane excitation system utilized during the flight flutter test programs accomplished during Lockheed L-1011 and S-3A development is described.

Hurley, S. R.

Hybrid Residual Flexibility/Mass-Additive Method for Structural Dynamic Testing

A large fixture was designed and constructed for modal vibration testing of International Space Station elements. This fixed-base test fixture, which weighs thousands of pounds and is anchored to a massive concrete floor, initially utilized spherical bearings and pendulum mechanisms to simulate Shuttle orbiter boundary constraints for launch of the hardware. Many difficulties were encountered during a checkout test of the common module prototype structure, mainly due to undesirable friction and excessive clearances in the test-article-to-fixture interface bearings. Measured mode shapes and frequencies were not representative of orbiter-constrained modes due to the friction and clearance effects in the bearings. As a result, a major redesign effort for the interface mechanisms was undertaken. The total cost of the fixture design, construction and checkout, and redesign was over $2 million. Because of the problems experienced with fixed-base testing, alternative free-suspension methods were studied, including the residual flexibility and mass-additive approaches. Free-suspension structural dynamics test methods utilize soft elastic bungee cords and overhead frame suspension systems that are less complex and much less expensive than fixed-base systems. The cost of free-suspension fixturing is on the order of tens of thousands of dollars as opposed to millions, for large fixed-base fixturing. In addition, free-suspension test configurations are portable, allowing modal tests to be done at sites without modal test facilities. For example, a mass-additive modal test of the ASTRO-1 Shuttle payload was done at the Kennedy Space Center launch site. In this Technical Memorandum, the mass-additive and residual flexibility test methods are described in detail. A discussion of a hybrid approach that combines the best characteristics of each method follows and is the focus of the study.

Tinker, M. L.

Proposal for a proton-bunch compression experiment at IOTA in the strong space-charge regime

The longitudinal compression of intense proton bunches with strong space-charge force is an essential component of a proton-based muon source for a muon collider. This paper discusses a proton-bunch compression experiment at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab to explore optimal radio frequency (RF) cavity and lattice configurations. IOTA is a compact fixed-energy storage ring that can circulate a 2.5-MeV proton beam with varying beam parameters and lattice configurations. The study will aim to demonstrate a bunch-compression factor of at least 2 in the IOTA ring while examining the impact of intense space-charge effects on the compression process.

43 PARTICLE ACCELERATORS

IOTA experiment for proton pulse compression at extreme space-charge

The longitudinal compression of intense proton bunches with strong space-charge force is an essential component of a proton driver for a muon collider. We propose a proton bunch compression experiment at the Integrable Optics Test Accelerator (IOTA) storage ring at Fermilab to explore optimal radio frequency (RF) cavity and lattice configurations. IOTA is a compact fixed-energy storage ring dedicated to beam physics R&D that can circulate a 2.5-MeV proton beam with extreme space-charge. Using ImpactX and its 3D space-charge solver, simulations indicate that bunch length can be rapidly reduced by a factor of at least two, without appreciable degradation in transverse beam quality, even under strong space-charge conditions. However, longitudinal defocusing presents a large effect in short-pulsed proton beams, and the optimization of bunch compression under such conditions is discussed.

Simons, Benjamin [Northern Illinois U.; Fermilab]

A Frequency-Domain Substructure System Identification Algorithm

A new frequency-domain system identification algorithm is presented for system identification of substructures, such as payloads to be flown aboard the Space Shuttle. In the vibration test, all interface degrees of freedom where the substructure is connected to the carrier structure are either subjected to active excitation or are supported by a test stand with the reaction forces measured. The measured frequency-response data is used to obtain a linear, viscous-damped model with all interface-degree of freedom entries included. This model can then be used to validate analytical substructure models. This procedure makes it possible to obtain not only the fixed-interface modal data associated with a Craig-Bampton substructure model, but also the data associated with constraint modes. With this proposed algorithm, multiple-boundary-condition tests are not required, and test-stand dynamics is accounted for without requiring a separate modal test or finite element modeling of the test stand. Numerical simulations are used in examining the algorithm's ability to estimate valid reduced-order structural models. The algorithm's performance when frequency-response data covering narrow and broad frequency bandwidths is used as input is explored. Its performance when noise is added to the frequency-response data and the use of different least squares solution techniques are also examined. The identified reduced-order models are also compared for accuracy with other test-analysis models and a formulation for a Craig-Bampton test-analysis model is also presented.

Blades, Eric L.

Sensor for measuring instantaneous angle of attack of helicopter blades

Systematic investigations were performed on a variety of probes to determine their potential for possible application as sensors attached to helicopter blades to measure both the instantaneous angle of attack as well as the dynamic head during actual flight operations. After some preliminary considerations a sensor of essentially spherical shape, about 30 mm in diameter, was designed. The sensor was provided with three pressure ports, and it housed two pressure transducers required for sensing the prevailing pressures acting outside on the surface. The sensors were subsequently tested in the laboratory under a variety of flow conditions to determine their aerodynamic characteristics. Two series of tests were performed: in the first series the sensor was fixed in space while exposed to steady uniform flow, while in the second series the sensor was made to oscillate, thus simulating the cyclic pitch change of the helicopter blades. While the cyclic pitch frequencies were of about the same magnitude as encountered in flight, the flow velocities during tests fell well below those experienced in a rotating blade. The tests showed that the sensors performed satisfactorily under low subsonic flow conditions with frequencies not exceeding five Hz.

Barna, P. S.