At least 55 records · Page 3

Firefighting Module

NASA and the U.S. Coast Guard are working jointly to develop a helicopter transportable firefighting module that can shave precious minutes in combating shipboard or harbor fires. The program was undertaken in 1975, after a series of disastrous fires on oil tankers indicated a need for a lightweight, self-contained system that could be moved quickly to the scene of a fire. A prototype module was delivered to the Coast Guard last year and service testing is under way. The compact module weighs little more than a ton but it contains everything needed to fight a fire. The key component is a high output pump, which delivers up to 2,000 gallons of sea water a minute; the pump can be brought up to maximum output in only one minute after turning on the power source, a small Allison gas turbine engine. The module also contains hose, a foam nozzle and a spray nozzle, three sets of protective clothing for firefighters, and fuel for three hours operation. Designed to be assembled without special tools, the module can be set up for operation in less than 20 minutes.

Source record↗

High Temperature Heat Pumps and Their Roles in the Decarbonization of Building and Industry

Heat pumps have been sought as a promising technology for air and water heating processes in buildings. Several OEMs have been commercializing heat pumps with varying capacities; However, the application has been limited to lower temperatures (less than 70℃). With the recently growing interest in replacing gas-fired equipment for buildings and industrial processes, a new class of heat pumps, known as high-temperature heat pumps, is gaining substantial interest where the target temperatures are higher than the conventional heat pump technology (greater than 90℃). The current study is focused on this class of heat pumps and aims to provide a holistic overview of state-of-the-art technology while highlighting major challenges and opportunities. The discussion will be focused on the availability of technology to enable higher sink temperatures, deployment-based applications, waste heat recovery, and process integration and controls.

Nawaz, Kashif↗

Repowering Coal Plants as Pumped Thermal Energy Storage

This conference presentation presents the results from a DOE FE funded study on the integration of a Malta Pumped Heat Energy Storage system with a retiring coal-fired power plant, and the economic benefits to the asset owner and the local community.

20 FOSSIL-FUELED POWER PLANTS↗

Enabling residential heating decarbonization through hydronic low-temperature thermal distribution using forced-air assistive devices

Space heating represents approximately one-tenth of the United States’ energy use and has a breadth of potential for emission reduction. An element of space heating, hydronic heat distribution methods, use water supply temperatures up to 82.2 °C (180 °F). However, this operating temperature can be incompatible with high-efficiency heat generation systems, which typically provide heating temperatures of up to 60 °C (140 °F). In this work, a low-cost retrofit solution is developed using experimentally validated computational tools by incorporating an airflow distributor that preferentially directs the airflow from a fan to enhance heat transfer over the finned-tube heat exchanger found in conventional baseboards. The same heat output of traditional baseboard heat distribution systems operating at higher water supply temperatures (71.1 – 82.2 °C) can also be achieved at lower temperatures (≤60 °C). Specifically, results indicate that the technology can produce more than a 46.7% improvement in the heat transfer output at temperatures as low as 60 °C (140 °F), effectively matching the same output range achieved by 71.1 – 82.2 °C (160–180 °F) water supply temperatures. An important benefit of this solution is that it utilizes the existing infrastructure as opposed to requiring the replacement of the entire distribution system. Additionally, this technology enables existing building infrastructure to be coupled with newer, high-efficiency heating systems such as condensing boilers, solar-thermal systems, and geothermal/air-to-water heat pumps that may produce lower water supply temperatures (60 °C). A geospatially resolved techno-economic and environmental analysis is completed and presented to further understand the equivalent carbon footprint of enabling higher efficiency heat generation systems with the improved efficiency heat distribution system disclosed. Using 2021 grid-average emission factors, an emission reduction of up to a 67.5% decrease (2658 kgCO 2 /yr) for a single-family home, depending on state and climate region, could be realized by replacing a traditional natural gas-fired boiler with an air-to-water heat pump coupled to the same high-temperature heat distribution system along with the low-cost retrofit solution. A complete CO 2 emission reduction of 6688 kgCO 2 /yr, depending on state and climate region, could be realized if all electricity is further renewably sourced. Thus, this study provides a possible pathway towards enabling the reduction of operational emissions in space heating.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Transient absorption spectroscopy to explore cellular pathways to photobiomodulation

Photobiomodulation (PBM) describes the use of low irradiance light in the red to near-infrared wavelength range to stimulate biological effects in tissue, and many biological and spectroscopic techniques are used to study PBM. However, these techniques focus on the products or downstream effects rather than the electronic transitions that initiate the PBM processes. This study presents a novel approach to studying low irradiance light exposures on individual proteins and/or protein complexes by combining a continuous wave (CW) laser diode with femtosecond transient absorption spectroscopy (TAS), coined here as CW-TAS, and tests the system on reduced cytochrome c (Cyt c) for proof of principle. TAS was conducted using a 532-nm excitation pump beam and a 350-600 nm supercontinuum probe. In this work, CW laser diodes with wavelengths of 450 nm, 635 nm, and 808 nm were interchangeably fiber coupled into the HELIOS Fire. Samples of Cyt c were tested by TAS using a pump power of 15 µW, both with and without CW exposure. CW exposures were carried out with irradiances of 1.60 and 3.20 mW/cm 2 , except for 808 nm, which was only tested at 1.60 mW/cm 2 . Both kinetic and global analyses were performed on the TAS data and the time constants for sets with and without CW exposures were compared. The TAS data for Cyt c with the full dosage of CW exposures did not alter the TAS data distinguishably from the control data. No new electronic transient signals were observed beyond the background when testing Cyt c with the CW exposures. Kinetic analysis confirmed that existing transients did not deviate beyond uncertainty. Global time constants for Cyt c were calculated to be 0.25 ± 0.03 ps and 5.1 ± 0.3 ps for the control study, and the time constants for the CW exposed Cyt c were not significantly different. This study concludes that CW irradiation, at doses delivered, does not alter the transient absorption data of Cyt c. The CW-TAS method provides a new tool for studying PBM effects in other proteins and protein complexes, such as Complex IV, in future studies.

59 BASIC BIOLOGICAL SCIENCES↗

Low-Carbon District Heating: Performance Modeling of Hybrid Solar, Heat Pump, and Thermal Storage Systems for District Thermal Energy in the United States

District heating requires thermal energy in the temperature range of 40 degrees C - 120 degrees C. Typically, the thermal energy input for these systems has largely been met through fossil energy. However, the temperature range is low enough that it presents an opportunity for low-carbon technologies such as solar thermal and electrified thermal generators like heat pumps to decarbonize the heat generation. In this paper, a heat pump model was applied to estimate the performance and economics of a real-world low-carbon district heating substation. This system is comprised of a flat plate solar collector field paired with a mechanical vapor compression heat pump and hot water thermal storage, augmented by gas-fired boilers. Plant data was used to tune the model and estimate the system's benefits in terms of both standard financial metrics (IRR and payback), and environmental metrics, including avoided CO2 emissions. The model is subsequently employed to estimate the technical and economic potential of solar + heat pump + ther-mal storage hybrid systems as retrofits for district heating systems in eight US Markets.

district heating↗

Transportable Pumps Could Save Oil Cargoes

Transportable pumps designed for firefighting used to salvage crude oil from tankships leaking, burning, or grounded. Pump incorporated into self-contained transportable module along with engine and controls. Module carried by helicopter, boat, or van to site of fire provides large quantities of water at high pressure in firefighting mode or pump oil into barge in salvage mode.

Burns, R.↗

Linear and Nonlinear Aspects of Rotordynamics

Excessive vibrations of the liquid oxygen pump in the Space Shuttle's Main Engine have been recorded during hot firing ground testing. In order to determine mathematical explanations of this possibility, destructive phenomenon differential equations have been examined which describe the rotordynamics of the pump. Modeling the rotor as a random eigenvalue problem was considered. Analytical expressions were derived for the solution in the case of symmetric damping and stiffness. This enables one to determine accuracy estimates when testing numerical techniques to solve both asymmetric and nonlinear problems. Finally, the rotor model has had nonlinear elements incorporated to improve its simulation of the pump and to expand the corresponding mathematical theory.

Day, W. B.↗

Installation guidelines for solar heating system, single-family residence at William OBrien State Park, Stillwater, Minnesota

Installation procedures for the single family residential solar heating system at the William O'Brien State Park, Stillwater, Minnesota, are presented. The system is a solar-assisted, hydronic-to-warm-air system with solar-assisted domestic water heating. It is composed of the following major components: liquid cooled flat plate collectors; water storage tank; passive solar-fired domestic water preheater; electric hot water heater; heat pump with electric backup; solar hot water coil unit; tube-and-shell heat exchanger, three pumps, and associated pipes and valving in an energy transport module; control system; and air-cooled heat purge unit. Installer guidelines are provided for each subsystem and includes testing and filling the system. Information is also given on the operating procedures, controls, caution requirements and routine and schedule maintenance.

Source record↗

Hydrogen Sensors Boost Hybrids; Today's Models Losing Gas?

Advanced chemical sensors are used in aeronautic and space applications to provide safety monitoring, emission monitoring, and fire detection. In order to fully do their jobs, these sensors must be able to operate in a range of environments. NASA has developed sensor technologies addressing these needs with the intent of improving safety, optimizing combustion efficiencies, and controlling emissions. On the ground, the chemical sensors were developed by NASA engineers to detect potential hydrogen leaks during Space Shuttle launch operations. The Space Shuttle uses a combination of hydrogen and oxygen as fuel for its main engines. Liquid hydrogen is pumped to the external tank from a storage tank located several hundred feet away. Any hydrogen leak could potentially result in a hydrogen fire, which is invisible to the naked eye. It is important to detect the presence of a hydrogen fire in order to prevent a major accident. In the air, the same hydrogen-leak dangers are present. Stress and temperature changes can cause tiny cracks or holes to form in the tubes that line the Space Shuttle s main engine nozzle. Such defects could allow the hydrogen that is pumped through the nozzle during firing to escape. Responding to the challenges associated with pinpointing hydrogen leaks, NASA endeavored to improve propellant leak-detection capabilities during assembly, pre-launch operations, and flight. The objective was to reduce the operational cost of assembling and maintaining hydrogen delivery systems with automated detection systems. In particular, efforts have been focused on developing an automated hydrogen leak-detection system using multiple, networked hydrogen sensors that are operable in harsh conditions.

Source record↗

Non-invasive ventral cervical magnetoneurography as a proxy of in vivo lipopolysaccharide-induced inflammation

Maintenance of autonomic homeostasis is continuously calibrated by sensory fibers of the vagus nerve and sympathetic chain that convey compound action potentials (CAPs) to the central nervous system. Lipopolysaccharide (LPS) intravenous challenge reliably elicits a robust inflammatory response that can resemble systemic inflammation and acute endotoxemia. Here, we administered LPS intravenously in nine healthy subjects while recording ventral cervical magnetoneurography (vcMNG)-derived CAPs at the rostral Right Nodose Ganglion (RNG) and the caudal Right Carotid Artery (RCA) with optically pumped magnetometers (OPM). We observed vcMNG RNG and RCA neural firing rates that tracked changes in TNF-α levels in the systemic circulation. Further, endotype subgroups based on high and low IL-6 responders segregate RNG CAP frequency (at 30-120 min) and based on high and low IL-10 response discriminate RCA CAP frequency (at 0-30 min). These vcMNG tools may enhance understanding and management of the neuroimmune axis that can guide personalized treatment based on an individual’s distinct endophenotype.

59 BASIC BIOLOGICAL SCIENCES↗

Nonlinear rotordynamics analysis

Three analytic consequences of the nonlinear Jeffcott equations are examined. The primary application of these analyses is directed toward understanding the excessive vibrations recorded in the Liquid Oxygen (LOX) pump of the Space Shuttle Main Engine (SSME) during hot firing ground testing. The first task is to provide bounds on the coefficients of the equations which delimit the two cases of numerical solution as a circle or an annulus. The second task examines the mathematical generalization to multiple forcing functions, which includes the special problems of mass imbalance, side force, rubbing, and combination of these forces. Finally, stability and boundedness of the steady-state solutions is discussed and related to the corresponding linear problem.

Day, W. B.↗

NASA Tech Briefs, March 2011

Topics covered include: Optimal Tuner Selection for Kalman-Filter-Based Aircraft Engine Performance Estimation; Airborne Radar Interferometric Repeat-Pass Processing; Plug-and-Play Environmental Monitoring Spacecraft Subsystem; Power-Combined GaN Amplifier with 2.28-W Output Power at 87 GHz; Wallops Ship Surveillance System; Source Lines Counter (SLiC) Version 4.0; Guidance, Navigation, and Control Program; Single-Frame Terrain Mapping Software for Robotic Vehicles; Auto Draw from Excel Input Files; Observation Scheduling System; CFDP for Interplanetary Overlay Network; X-Windows Widget for Image Display; Binary-Signal Recovery; Volumetric 3D Display System with Static Screen; MMIC Replacement for Gunn Diode Oscillators; Feature Acquisition with Imbalanced Training Data; Mount Protects Thin-Walled Glass or Ceramic Tubes from Large Thermal and Vibration Loads; Carbon Nanotube-Based Structural Health Monitoring Sensors; Wireless Inductive Power Device Suppresses Blade Vibrations; Safe, Advanced, Adaptable Isolation System Eliminates the Need for Critical Lifts; Anti-Rotation Device Releasable by Insertion of a Tool; A Magnetically Coupled Cryogenic Pump; Single Piezo-Actuator Rotary-Hammering Drill; Fire-Retardant Polymeric Additives; Catalytic Generation of Lift Gases for Balloons; Ionic Liquids to Replace Hydrazine; Variable Emittance Electrochromics Using Ionic Electrolytes and Low Solar Absorptance Coatings; Spacecraft Radiator Freeze Protection Using a Regenerative Heat Exchanger; Multi-Mission Power Analysis Tool; Correction for Self-Heating When Using Thermometers as Heaters in Precision Control Applications; Gravitational Wave Detection with Single-Laser Atom Interferometers; Titanium Alloy Strong Back for IXO Mirror Segments; Improved Ambient Pressure Pyroelectric Ion Source; Multi-Modal Image Registration and Matching for Localization of a Balloon on Titan; Entanglement in Quantum-Classical Hybrid; Algorithm for Autonomous Landing; Quantum-Classical Hybrid for Information Processing; Small-Scale Dissipation in Binary-Species Transitional Mixing Layers; Superpixel-Augmented Endmember Detection for Hyperspectral Images; Coding for Parallel Links to Maximize the Expected Value of Decodable Messages; and Microwave Tissue Soldering for Immediate Wound Closure.

Source record↗

Thanksgiving Hocus Pocus

I was managing the construction project, and I thought my biggest challenge was simply finishing the work in time for start of the holiday shopping season. The store opened three weeks before Thanksgiving. Everything looked great. Business picked up steadily as the serious spending season approached. Then, two days before Thanksgiving, disaster struck. The fire protection system was designed to prevent smoke and fire from reaching the merchandise. If a fire alarm went off anywhere in the building, the system went into a massive pressurization mode. Dampers would open and the system would pump in hundreds of cubic feet of air from outside into the store, pressurizing every square foot, preventing fire or smoke from spreading into the store. That night an unknown event tripped the alarm-and it sounded for six hours. The air conditioning system was still operational as the outside air temperatures had been warm all month. That night, however, temperatures plummeted to 20 degrees. With an alarm sounding in a building complex that covers many millions of square feet, no one paid attention to the cold air flowing into the space. Pipes froze and burst. Hundreds of gallons of water came down through the drywall, soaking merchandise, the carpet and the hardwood racks. This state of the art system, which had been designed to protect, was now responsible for unthinkable damage. You could be the among greatest project managers in world, but if you have an attitude and you give the client heartburn, unnecessary heartburn, you're not going to do more work with him. If you have a disaster like this one, and you manage to make everybody feel good and believe that you are going to take care of them, then everybody looks back on it and says, "You know what, this is a good project team; we work well together, so let's do another one."

Zazzali, Christian↗

Installation guidelines for solar heating system, single-family residence at New Castle, Pennsylvania

The solar heating system installer guidelines are presented for each subsystem. This single family residential heating system is a solar-assisted, hydronic-to-warm-air system with solar-assisted domestic water heating. It is composed of the following major components: (1) liquid cooled flat plate collectors; (2) water storage tank; (3) passive solar-fired domestic water preheater; (4) electric hot water heater; (5) heat pump with electric backup; (6) solar hot water coil unit; (7) tube-and-shell heat exchanger, three pumps, and associated pipes and valving in an energy transport module; (8) control system; and (9) air-cooled heat purge unit. Information is provided on the operating procedures, controls, caution requirements, and routine and schedule maintenance in the form of written descriptions, schematics, detail drawings, pictures, and manufacturer's component data.

Source record↗

The 5000 GPM firefighting module evaluation test

The 5000 GPM Firefighting Module development was sponsored and shared by the Navy Facilities Engineering Command. It is a lightweight, compact, self-contained, helicopter-transportable unit for fighting harbor and other specialty fires as well as for use in emergency and shipboard water pumping applications. This unit is a more advanced model of the original 1500 GPM module developed for the U.S. Coast Guard. The module and an evaluation test program conducted at the North Island Naval Air Station, San Diego, California, by NASA and the U.S. Navy, are described.

Burns, Ralph A.↗

Cost details from front-end engineering design of piperazine with the advanced stripper

This Front-End Engineering Design (FEED) was funded by the U.S. Department of Energy (DOE) to estimate the cost to capture and compress 90% of the CO 2 from an existing natural gas combined cycle (NGCC) in Denver City, Texas, USA. The FEED used the PZAS (Piperazine with the Advanced Stripper) 2G amine scrubbing technology developed and modeled by The University of Texas at Austin. This FEED is unique in providing more public cost details than other FEEDs funded by DOE. The primary objective of the FEED was to provide a comprehensive estimate for the total installed cost of the capture plant. The estimated capital cost of NGCC at the Mustang Station is $\$727$ million for a capacity of 460 MW and 1.6 million tonnes CO 2 /yr. This includes a contingency of $\$104.6$ million and a contractor’s profit of $\$60.1$ million. The total direct field cost is $\$384.1$ million. With an optimistic fuel value of $\$3$/MMBtu, the estimated cost of capture varies from $\$85$/t at 4% IRR/85% load to $\$170$/t at 10% IRR/52% load. Air cooling is technically feasible but expensive. The air cooling systems for the water wash and pump-around intercooling account for 23.4% of the direct cost. The gas-fired boilers represent only 4% of the direct costs, but steam extraction would reduce energy cost, free up cooling water, and reduce the direct costs of processing additional flue gas and CO 2 from the boilers. The absorbers represent 9.6% of the direct cost in this FEED with no direct contact cooler and only 7.6 m of packing. Furthermore, the solvent cross exchangers are less expensive than expected (2.5% of direct costs). Doubling the number of these exchangers could reduce the heat duty from 3.0 to 2.5 GJ/t CO 2 .

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Residual life assessment of the SSME/ATD HPOTP turnaround duct (TAD)

This paper is concerned with the prediction of the low cycle thermal fatigue behavior of a component in a developmental (ATD) high pressure liquid oxygen turbopump (HPOTP) for the Space Shuttle Main Engine (SSME). This component is called the Turnaround Duct (TAD). The TAD is a complex single piece casting of MAR-M-247 material. Its function is to turn the hot turbine exhaust gas (1200 F hydrogen rich gas steam) such that it can exhaust radially out of the turbopump. In very simple terms, the TAD consists of two rings connected axially by 22 hollow airfoil shaped struts with the turning vanes placed at the top, middle, and bottom of each strut. The TAD is attached to the other components of the pump via bolts passing through 14 of the 22 struts. Of the remaining 8 struts, four are equally spaced (90 deg interval) and containing a cooling tube through which liquid hydrogen passes on its way to cool the shaft bearing assemblies. The remaining 4 struts are empty. One of the pump units in the certification test series was destructively examined after 22 test firings. Substantial axial cracking was found in two of the struts which contain cooling tubes. None of the other 20 struts showed any sign of internal cracking. This unusual low cycle thermal fatigue behavior within the two cooling tube struts is the focus of this study.

Gross, R. Steven↗