Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Rapid Spaceborne Mapping of Wildfire Retardant Drops for Active Wildfire Management

Aerial application of fire retardant is a critical tool for managing wildland fire spread. Retardant applications are carefully planned to maximize fire line effectiveness, improve firefighter safety, protect high-value resources and assets, and limit environmental impact. However, topography, wind, visibility, and aircraft orientation can lead to differences between planned drop locations and the actual placement of the retardant. Information on the precise placement and areal extent of the dropped retardant can provide wildland fire managers with key information to (1) adaptively manage event resources, (2) assess the effectiveness of retardant slowing or stopping fire spread, (3) document location in relation to ecologically sensitive areas; and perform or validate cost-accounting for drop services. This study uses Sentinel-2 satellite data and commonly used machine learning classifiers to test an automated approach for detecting and mapping retardant application. We show that a multiclass model (retardant, burned, unburned, and cloud artifact classes) outperforms a single-class retardant model and that image differencing (post-application minus pre-application) outperforms single-image models. Compared to the random forest and support vector machine, the gradient boosting model performed the best with an overall accuracy of 0.88 and an F1 Score of 0.76 for fire retardant, though results were comparable for all three models. Our approach maps the full areal extent of the dropped retardant within minutes of image availability, rather than linear representations currently mapped by aerial GPS surveys. The development of this capability allows for the rapid assessment of retardant effectiveness and documentation of placement in relation to sensitive environments.

54 ENVIRONMENTAL SCIENCES↗

Multi-Gigawatt Electric Highway

Ultra-Compact Electrical Transmission Lines are a new transmission line technology that uses large, hollow, aluminum beams to carry current instead of thin wires. Capacity is 4.5 times higher, power losses are 3 times lower, and cost per mile is a little lower than conventional lines. Resilience and reliability are higher. The beams are enclosed within concrete walls and out of the weather, protected from high winds, ice storms, fires, and lightning. The 230 kV version is 9 feet high x 11 feet wide and can use existing rights of way next to existing transmission lines or highways. With a little landscaping, these transmission lines are not an eyesore and will be much easier to permit on existing rights of way.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Realistic operation of two residential cordwood-fired outdoor hydronic heater appliances—Part 2: Particle number and size

The use of wood as a fuel for home heating is a concern from an environmental health and safety perspective as biomass combustion appliances emit high concentrations of particulate matter. Wood burning significantly contributes to wintertime particulate matter concentrations in many states in the northern United States. Of particular concern are outdoor wood-fired hydronic heaters. These devices are concerning as they tend to have very large combustion chambers and typical use patterns can result in long periods of low output, which result in an increased particulate matter emission rate relative to high heat output operating conditions. In this study, the performance of two hydronic heaters operating under different combustion conditions, including four different heat output categories approximately corresponding to categories I–IV denoted in Environmental Protection Agency Method 28 Outdoor Wood-fired Hydronic Heaters, and during start-up and reloading events were investigated. Measurements of flue gas particulate number concentration and size for particles with aerodynamic diameters between 0.006 and 10 µm were made using a dilution sampling system. The measured particle number concentration in the flue gas was between 0.71 and 420 million particles per cubic centimeter and was dependent on fuel loading and heat output. For each hydronic heater tested, the highest average particle concentration was found at the beginning of each test during the cold-start condition. Additionally, the majority of the particles had aerodynamic diameters less than 0.100 µm (particles of this size made up between 64% and 97% of all particles) and less than 1% of all particles had aerodynamic diameters greater than 1 µm for all phases. For particles in the accumulation mode, between 0.100 and 1 µm, the mean particle diameter was dependent on fuel loading and heat output.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

When Do Riverine Systems “Feel the Burn”? Simulating How Burn Extent and Severity Modulate Hydrologic Controls on Biogeochemical Export

Wildfires impact terrestrial landscapes and downstream river corridors through shifts in vegetation and soil properties leading to downstream hydrologic and water quality impacts. The magnitude of these impacts depend on a complex and interconnected set of wildfire, landscape, and aquatic processes. Here, we isolate the impact of post-fire hydrologic changes on streamflow, nitrate, and dissolved organic carbon using the Soil and Water Assessment Tool (SWAT) model. We explore how responses differ across burn severity and area burned in two test basins: a humid forested basin and a semi-arid mixed land use basin. We ran 1830 wildfire simulations testing impacts of area burned, burn severity, and post-fire precipitation on streamflow, nitrate, and dissolved organic carbon. Our work suggests that area burned thresholds differ with burn severity and analyte. Additionally, post-fire transport of dissolved organic carbon was sensitive to both area burned and severity, while nitrate was primarily sensitive to area burned. Despite a muted (−9.5 to 5.7 mm yr −1 change) hydrologic response in the semi-arid basin, the model predicted large (7%–288% increase) shifts in dissolved organic carbon, suggesting that post-fire shifts in flow pathways and soil properties are key in its response. The limited shifts in nitrate responses in the simulations highlight that terrestrial post-fire transformations, rather than hydrologic changes, may control the increases in stream nitrate often observed post-fire. As wildfire regimes are shifting, improving understanding of post-fire nutrient export responses is critical to protect freshwater resources and aquatic ecosystems.

Wampler, Katherine A. [Pacific Northwest National ↗

Toward an AI-Powered Software Pipeline for Real-Time Tracking and Analysis of Wildfire and Smoke

Real-time tracking of wildfires and smoke is crucial for effective response, minimizing damage, protecting lives, and efficiently managing resources during fire emergencies. We develop a web-based AI-powered pipeline that detects wildfires in aerial video and estimates deployment-relevant behavior metrics, including cumulative burned area, burned-area growth rate, fire spread direction, and smoke dispersion. The system combines a YOLO-based detector with YCbCr-based fire segmentation, HSV-based smoke segmentation, Farneback optical flow, and centroid-based spatiotemporal tracking. Using ground sampling distance (GSD), pixel-level fire masks are converted to physical burned-area measurements by correlating fire pixel counts with camera altitude and tilt angle. We benchmark YOLO variants and non-YOLO baselines (GoogLeNet, CNN, DBN, Autoencoder, U-Net, and AlexNet) on the IEEE FLAME dataset and a newly created aerial frame dataset, Wildfire-DB. Cross-dataset evaluation uses a strict threshold-transfer protocol: decision thresholds are selected on FLAME validation and transferred unchanged to Wildfire-DB to quantify generalization under domain shift. YOLOv6 achieves the strongest cross-dataset frame-level fire detection on Wildfire-DB (ROC-AUC 0.8200, PR-AUC 0.8044, and transferred-threshold F1 0.7596). For tracking-oriented deployment requiring oriented localization, YOLO11-OBB provides the most reliable cross-dataset behavior among OBB-capable models while remaining computationally feasible. To analyze the feasibility of UAV deployment, we further measure inference efficiency using synchronized GPU and CPU power logs on a fixed workload of 1569 frames. YOLO-family models process the video in 5.73–12.47 seconds with net energy of 1247.28–1775.39 J, substantially lower latency and energy than heavier classification and reconstruction baselines. Overall, model optimality depends on operational objectives: YOLOv6 is best for cross-dataset detection robustness, whereas YOL...

Color segmentation↗

Annual Stormwater Report for the Y-12 National Security Complex Oak Ridge, Tennessee

This is the ninth annual stormwater report prepared in accordance with the modified National Pollutant Discharge Elimination System permit issued to the Y-12 National Security Complex (Y-12) on April 1, 2014. This modified permit removed the authorization to augment flow in East Fork Poplar Creek (EFPC) and thus removed the requirement to sample this effluent in conjunction with other major outfalls on EFPC. There are several construction and demolition activities currently in progress at Y-12. These include the construction of the Uranium Processing Facility (UPF), the Mercury Treatment Facility (MTF) on EFPC, the site-wide power grid upgrade, construction of an Emergency Operations Center, construction of a new Fire Station, Security Improvement Revitalization Program (SIRP), West End Protection Area Reduction (WEPAR) Project, and the demolition of the Biology Complex. Current stormwater protections have proven effective in 2021. However, moving forward, challenges to protect stormwater will continue from these projects. Therefore, oversight of these activities, and all other construction and demolition projects, will continue to be a priority in 2022. Y-12 will continue to implement appropriate Best Management Practices and reduce outside material storage areas where possible.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Electronic Waste (E-Waste) Recycling: Barriers and Opportunities for State, Local, and Tribal Governments

Electronic waste, or e-waste, encompasses end-of-life electrical and electronic equipment, including computers, monitors, televisions, printers, cell phones, household appliances with electronic components, and small consumer devices containing batteries or circuitry. E-waste is one of the fastest-growing components of the U.S. waste stream, with nearly 8 million tons generated in 2022. E-waste presents two related public-interest considerations. First, e-waste contains economically and strategically important materials: base metals (copper, aluminum, iron, steel), precious metals (gold, silver, platinum group metals), and critical materials such as rare earth elements, gallium, and indium that appear on the U.S. Geological Survey's (USGS) 2025 List of Critical Minerals. Second, many electronic devices contain hazardous constituents - including lead, mercury, cadmium, and brominated flame retardants - as well as rechargeable batteries that can pose fire risks during handling. Effective management of these constituents helps protect workers, communities, and the environment. In the United States, it is estimated that less than 20% of e-waste is formally collected and recycled, leaving over 6 million tons landfilled or otherwise unrecovered. This fact sheet provides state and local decision-makers an overview of (1) e-waste composition and recoverable materials, (2) technology pathways used to recover those materials, and (3) examples of operational and partnership structures used to provide e-waste recycling capacity in the United States. It is intended to complement existing collection-program guidance available through U.S. Environmental Protection Agency (EPA) and other sources.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Tree mortality after a spring fire: the role of reduced live leaf area in depletion of early growing season bole NSC

Prescribed fire is used as a tool to achieve various ecological objectives in fire-adapted ecosystems (Ryan et al. 2013). These objectives often include targeted mortality of encroaching species to minimize the risk of catastrophic wildfire (Ryan et al. 2013). Achieving mortality of some species while protecting others requires a foundational understanding of how different species respond to different types of fire at different times of year.

59 BASIC BIOLOGICAL SCIENCES↗

TES: Modelling Microbes to Predict Post-Fire Carbon Cycling in the Boreal Forest across Burn Severities (Exploratory Proposal)

Wildfires in boreal ecosystems represent a globally significant ecological process that is expected to be sensitive to changing climate as well as forest management strategies, but is currently insufficiently understood and represented in models. We sought to determine whether linking belowground microbial community composition, size, and activity to aboveground properties of burn severity and plant community composition (upland jack pine and upland spruce) would allow us to better model post-fire soil CO 2 fluxes using the Carbon, Organisms, Rhizosphere and Protection in the Soil Environment (CORPSE) model. We used an integrated modelling experimental approach, with mechanistic laboratory experiments designed to inform models.

54 ENVIRONMENTAL SCIENCES↗

Scoping Thermal Response Calculations of RNS Waste During Transport to and Disposal at the WIPP

Sandia National Laboratories (SNL) was contracted by the United States Department of Energy Environmental Management (DOE-EM), Los Alamos Field Office to perform mechanical and thermal scoping calculations as part of a study seeking to understand the ignitability risk of the Remediated Nitrate Salts (RNS) waste drums during transportation from the Waste Control Specialists (WCS) facility to Waste Isolation Pilot Plant (WIPP) and permanent disposal of the waste at WIPP. The scoping thermal simulations described in this report pertain to thermal calculations performed with a packaging system consisting of one Standard Waste Box (SWB) loaded with drums placed inside a Standard Large Box 2 (SLB2). During transportation, the SLB2 is inside Transuranic Package Transporter Model III (TRUPACT-III), which provides the third layer of the packaging. Once at the WIPP, it is assumed the SLB2 is extracted from the TRUPACT-III and maintained above ground, and then subsequently placed underground for permanent disposal. In these proposed configurations, the space between the SLB2 and the SWB is always filled by a layer of insulation consisting of air-filled glass microbubbles except for the bottom which rests directly on the SLB2. The thermal scoping calculations described in this report specifically address whether the introduction of external heat inputs, combined with the contributions from the internally generated radiolytic decay heat and chemical reactions, lead to an unstable thermal state during the time of its movement and placement in the permanent disposal location. The external heat inputs are of two forms: 1) ambient thermal irradiation (e.g., solar and ambient storage/disposal temperatures) and 2) accident-induced fire. Three scoping calculation scenarios were derived as representative, conservative scenarios: 1A) TRUPACT-III transient transportation, 1B) SLB2 48-hour outdoor storage with solar radiation, and 2) fully-engulfing fire during SLB2 handling or emplacement following a steady-state analysis in a 38 °C environment. All the simulated scenarios are conservative relative to the operational conditions expected for handling the waste package during transportation and placement in the WIPP underground disposal unit. The predictions obtained from simulating the three exposure scenarios revealed that adding the SLB2 and the air-filled glass microbubbles to the transport and storage/disposal configurations provides additional thermal protection of the drums beyond what the SWB provides alone, both during long-term above ground insolation and underground during a fire accident. Under the current transportation/storage/disposal concepts, the degree of protection provided by the packaging concept is sufficient to prevent the waste from being ignitable. The simulation results demonstrate that there is adequate margin to safely transport and place the RNS waste from WCS to the WIPP under the current operational concept.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Wildfire-Power Grid Interactions: Feedback, Impacts, Monitoring, Modeling, and Mitigation Strategies

Wildfires are increasingly interacting with electric power systems through a two-way hazard chain: fires damage grid assets and trigger cascading outages, while grid faults can ignite new fires under hot, dry, and windy conditions. This review synthesizes the state of knowledge across five domains: (i) physical impacts of flames, heat, and smoke on lines, towers, insulators, and substations; (ii) power-infrastructure-initiated ignitions via conductor clash, high-impedance faults, and corona discharge; (iii) widespread blackouts and disproportionate societal impacts; (iv) multi-scale monitoring spanning laboratory tests, in-situ and grid-integrated sensors, and Earth observation; (v) coupled modeling that links fire behavior with grid operations; and (vi) technological and strategic mitigation pathways spanning prevention, response, and recovery. We integrate these domains into a novel 'feedback-aware' socio-technical framework. Through a longitudinal analysis (2005-2025) of global incidents, we identify that while vegetation contact remains the most frequent ignition source, aging infrastructure failure has emerged as a critical driver of catastrophic 'mega-fires'. We further identify persistent gaps, including limited interoperability of high-frequency grid and environmental data, scarce real-time data assimilation, and under-developed equity metrics for outage management. We conclude by outlining a research agenda to (1) deploy interoperable sensing architectures, (2) advance feedback-coupled fire-grid simulations, and (3) evaluate mitigation portfolios through techno-economic and fairness lenses. Recognizing wildfire-grid interactions as coupled socio-technical systems is essential for protecting infrastructure and communities and for ensuring reliable, sustainable electricity in a changing world.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Linking repeat lidar with Landsat products for large scale quantification of fire-induced permafrost thaw settlement in interior Alaska

The permafrost–fire–climate system has been a hotspot in research for decades under a warming climate scenario. Surface vegetation plays a dominant role in protecting permafrost from summer warmth, thus, any alteration of vegetation structure, particularly following severe wildfires, can cause dramatic top–down thaw. A challenge in understanding this is to quantify fire-induced thaw settlement at large scales (>1000 km 2 ). In this study, we explored the potential of using Landsat products for a large-scale estimation of fire-induced thaw settlement across a well-studied area representative of ice-rich lowland permafrost in interior Alaska. Six large fires have affected ~1250 km 2 of the area since 2000. We first identified the linkage of fires, burn severity, and land cover response, and then developed an object-based machine learning ensemble approach to estimate fire-induced thaw settlement by relating airborne repeat lidar data to Landsat products. The model delineated thaw settlement patterns across the six fire scars and explained ~65% of the variance in lidar-detected elevation change. Our results indicate a combined application of airborne repeat lidar and Landsat products is a valuable tool for large scale quantification of fire-induced thaw settlement.

54 ENVIRONMENTAL SCIENCES↗

Long-Term Persistence of Three Microbial Wildfire Biomarkers in Forest Soils

Long-term monitoring of microbial communities in the rhizosphere of post-fire forests is currently one of the key knowledge gaps. Knowing the time scale of the effects is indispensable to aiding post-fire recovery in vulnerable woodlands, including holm oak forests, that are subjected to a Mediterranean climate, as is the case with forests that are found in protected areas such as the Sierra Nevada National and Natural Park in southeastern Spain. We took rhizosphere soil samples from burned and unburned holm oak trees approximately 3, 6, and 9 years after the 2005 fire that devastated almost 3500 ha in southeastern Spain. We observed that the prokaryotic communities are recovering but have not yet reached the conditions observed in the unburned forest. A common denominator between this fire and other fires is the long-term persistence of three ecosystem recovery biomarkers—specifically, higher proportions of the genera Arthrobacter, Blastococcus, and Massilia in soil microbial communities after a forest fire. These pyrophilous microbes possess remarkable resilience against adverse conditions, exhibiting traits such as xerotolerance, nitrogen mineralization, degradation of aromatic compounds, and copiotrophy in favorable conditions. Furthermore, these biomarkers thrive in alkaline environments, which persist over the long term following forest fires. The relative abundance of these biomarkers showed a decreasing trend over time, but they were still far from the values of the control condition. In conclusion, a decade does not seem to be enough for the complete recovery of the prokaryotic communities in this Mediterranean ecosystem.

54 ENVIRONMENTAL SCIENCES↗

Wildfire‐Induced Losses of Soil Particulate and Mineral‐Associated Organic Carbon Persist for Over 4 Years in a Chaparral Ecosystem

ABSTRACT Wildfires can lower soil carbon (C) stocks directly through combustion, but also indirectly during post‐fire recovery if microbial C demands outpace photosynthetic C inputs. However, how much C is respired by soil microorganisms post‐fire may depend on wildfire effects on particulate organic carbon (POC; mostly plant material accessible to microbes) and/or mineral‐associated organic carbon (MAOC; considered C protected by minerals from decomposers), meaning assessment of wildfire impacts on these pools is necessary to predict microbial decomposition rates and, thus, the fate of soil C. Here, we measured POC, MAOC, pyrogenic organic matter C, plant cover, extracellular enzyme activity (EEA), and microbial community abundance and composition 17 days, and 1, 3, and 4 years after the Holy Fire burned 94 km 2 of fire‐adapted chaparral. The wildfire immediately decreased POC by 50% (from 51 ± 21 to 26 ± 6 g C kg −1 ) and MAOC by 33% (from 9.3 ± 0.9 to 6.3 ± 0.9 g C kg −1 ), consistent with MAOC being less vulnerable to loss than POC. POC decreased by another 38% 1 year post‐fire, consistent with increases in microbial abundance and EEA suggesting increased microbial decomposition. Between 1 and 4 years after the fire, cover of the dominant shrub (Arctostaphylos glandulosa) increased from 3.9% ± 1.6% to 16% ± 5.4% (compared to 58% ± 4.6% in unburned plots), marking the end of net soil C losses. Still, soil C did not increase between 1 and 4 years post‐fire, suggesting plant C inputs did not outpace microbial respiration, a finding consistent with isotopically heavier C from microorganisms raising bulk soil δ 13 C values. As global changes favor increases in wildfire frequency and severity, C losses via combustion and decomposition may outpace plant C inputs during the first 4 years post‐fire in chaparral, slowing the replenishment of soil C stocks.

Biodiversity & Conservation↗

Impact of grassland fire dynamics on particulate emission factors

Understanding particulate emission factors in grassland fires is critical for improving air quality assessments and refining emissions inventories. This study explores the dynamic and heterogeneous nature of fire processes and their influence on particulate emissions. Traditional emission factor inventories often rely on static values, overlooking the spatially and temporally variable dynamics of fire behavior. Through field experiments conducted at Konza Prairie Biological Station measuring emissions with uncrewed aerial vehicles, and computational modeling using HIGRAD/FIRETEC, this research highlights the dependency of emission production on localized fire dynamics, including ignition patterns, fuel properties, and atmospheric conditions. The results demonstrate a need for fire dynamic considerations to accurately capture emissions variability.

09 BIOMASS FUELS↗

Effects of Part-to-Part Flow Variations on Overall Effectiveness and Life of Rotating Turbine Blades

Abstract As firing temperatures in gas turbine engines continue to increase to achieve high efficiencies, components in the main gas path must be protected with cooling flows to ensure lifing targets are met. Manufacturing variations, however, influence the performance and life characteristics of components with the same nominal design. This study presents blade flow and overall cooling effectiveness measurements for nine true-scale, aero engine turbine blades with realistic manufacturing variations. Flow measurements were made through each blade at a fixed pressure ratio to determine flow variability between holes and between blades. Infrared thermography was used to capture spatially-resolved temperature measurements reported as overall effectiveness on the same nine blades under high-speed rotating conditions at the Steady Thermal Aero Research Turbine Laboratory. Thermal performance was correlated with blade flow performance indicating substantial blade-to-blade variations resulting from manufacturing differences. Measurements also indicated wide variations in cooling jet trajectories as well as overall cooling effectiveness. Finally, the observed blade-to-blade variations in effectiveness were scaled to engine conditions with lifing estimates showing some blades would be expected to last only half as long as others due to manufacturing variability.

Engineering↗

Ultra-High Temperature Thermal Barrier Coating Development and Validation

The most effective method to improve industrial gas turbine power is to increase firing temperature. To maintain component durability at these higher temperatures, thermal barrier coatings (TBC’s) are playing an increasing role in protecting turbine hardware. TBC’s have been successfully used on Solar Turbines’ combustor liners and turbine airfoils, but there is a need for TBC’s that can operate at higher temperatures. Based on recent, favorable rig testing experience, Solar recognized that yttrium aluminum garnet (YAG) TBC’s made by the Solution Precursor Plasma Spray Process (SPPS) has great potential for higher turbine temperatures. This testing verified the thermal cycle durability of the SPPS YAG TBC’s, as well as demonstrated that the temperature drop through the SPPS YAG TBC was twice that measured across a companion APS YSZ TBC. The SPPS YAG TBC with the potential for a 200°C improvement in temperature capability represents a materials breakthrough. The SPPS process also produces a number of unique microstructural features that confer superior properties. SPPC TBC’s have ultra-fine splats that increase toughness and erosion resistance, and the process can be tailored to produce through-thickness cracks for strain-tolerance and control porosity for lower thermal conductivity and increase coating abradability. This proposal would include further development of SPPS YAG density-graded coatings, optimization of the application process, and validation of higher temperature capability and durability through rig and engine testing of coated combustion liners and turbine outer air seals. The technology would be advanced from a TRL 3 to a proposed TRL 6 by overcoming processing concerns on efficiency, application distance and optimization of a graded coating without impacting coating durability by demonstrating the coating performance on components in rig and development gas turbine engine testing.

36 MATERIALS SCIENCE↗

Uinta Basin CarbonSAFE II: Storage Complex Feasibility (Final Report)

The primary objective of this CarbonSAFE Phase II project was to establish the technical and commercial feasibility of a commercial-scale CO 2 geological storage complex for Deseret Power Electric Cooperative Bonanza Power Plant and other CO 2 sources in the northeast Uinta Basin, Utah, with the goal to securely store at least 50 million metric tons of captured CO 2 and accelerate CO 2 capture, utilization, and storage (CCUS) deployment. The project team established high-potential technical and commercial feasibility for a storage site within the east Uinta Basin (Utah), in the Cretaceous sandstones (Frontier, Dakota, and Buckhorn), Entrada Sandstone, Nugget Sandstone, and/or Weber Sandstone southwest of the Bonanza coal-fired power plant. This project collected and analyzed state-of-the-art data to characterize the storage complex consistent with Environmental Protection Agency (EPA) permitting standards. The team conducted extensive analog studies, outcrop mapping, and data sampling, which largely contributed to understanding the subsurface lithology and facies. Existing data were obtained and assessed from Utah Division of Oil, Gas, and Mining (DOGM), Utah Geological Survey (UGS), Colorado Geological Survey (CGS), U.S. Geological Survey (USGS), and EPA. These data were analyzed using state-of-the-art CCUS technologies for Societal Considerations, Site Characterization, Modeling and Simulations, Risk Assessment, Management and Monitoring, potential Underground Injection Control (UIC) Class VI Well Permitting, and Technical/Economic Feasibility. Through these high-resolution data collection and feasibility studies, this project was expected to provide a reference for initiating Underground Injection Control (UIC) and other commercial-scale geological storage permitting processes in the Western United States, ultimately contributing to the nation's decarbonization goals through low-risk, cost-effective commercial-scale carbon capture, utilization, and storage (CCUS) projects.

42 ENGINEERING↗