Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Fire Containment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

AmeriFlux FLUXNET-1F US-Me2 Metolius mature ponderosa pine

This is the AmeriFlux Management Project (AMP) created FLUXNET-1F version of the carbon flux data for the site US-Me2 Metolius mature ponderosa pine. This is the FLUXNET version of the carbon flux data for the site US-Me2 Metolius mature ponderosa pine produced by applying the standard ONEFlux (1F) software. Site Description - Site Description before Fire (January, 2002 - August, 2020): The mean stand age is 71 years old and the stand age of the oldest 10% of trees is about 108 years old. This site is one of the Metolius core cluster sites with different age and disturbance classes and part of the AmeriFlux network. The overstory is almost exclusively composed of ponderosa pine trees (Pinus ponderosa Doug. Ex P. Laws) with a few scattered incense cedars (Calocedrus decurrens (Torr.) Florin) and has a peak leaf area index (LAI) of 2.1 m2 m-2. Tree height is relatively homogeneous at about 18 m, and the mean tree density is approximately 339 trees ha-1 (Irvine et al., 2008). The understory is sparse with an LAI of 0.2 m2 m-2 and primarily composed of bitterbrush (Purshia tridentata (Push) DC.) and greenleaf manzanita (Arctostaphylos patula Greene). Soils at the site are sandy (69%/24%/7% sand/silt/clay at 0–0.2 m depth and 66%/27%/7% at 0.2–0.5 m depth, and 54%/ 35%/11% at 0.5–1.0 m depth), freely draining with a soil depth of approximately 1.5 m (Irvine et al., 2008; Law et al., 2001b; Schwarz et al., 2004). Green Ridge Fire: On August 20, 2020, the Green Ridge Fire burned through Us-Me2. The fire was ignited by lightning on August 16th, and grew rapidly to the east over the first few days driven by strong, downslope (westerly) afternoon winds. Fire behavior and observed fire effects were highly heterogeneous due to the localized wind pattern carrying the flaming head of the fire forward, and the efforts being made by suppression resources to contain the fire. The site experienced the full range of fire effects, from <1 m high surface fire that charred litter and duff and only consumed shrubs and herbaceous material to full tree (>15 m) crown fire that consumed 100% of needles, small limbs, and surface fuels at high intensity, leaving only ash and bare soil post-fire. Salvage Logging: From late March to late April 2021, salvage logging by the landowner occurred at the site. Almost all trees within the flux footprint were logged except a small area with lower burn severity, where sap flow and automatic soil respiration measurements are continued since the fire. In August 2022 the primary flux system was moved from the top of the damaged tall tower to a nearby shorter tower centering on the salvage/regenerating footprint.

Hanson, Chad↗

Fire-retardant covering for small containers

Flexible intumescent sheets of exceptionally uniform thickness may be used to protect containers and other small objects less than 25.4 cm in diameter from fire hazards.

Riccitiello, S. R.↗

Lithium-Ion UPS Battery Research and Commentary

Lithium-ion batteries are increasingly prevalent in a variety of devices both small and large. The high level of stored energy in UPS battery racks is closely scrutinized because sudden, uncontrolled release of chemical and electrical energy could be an ignition source. With this in mind, lithium-ion battery safety is the subject of several testing standards, including UL 1642, UL 1973, and UL 9540A.The motivation for this research and commentary is the potential installation of lithium-ion batteries in a Vertiv UPS assembly for one of the buildings on the ORNL campus. The battery modules Vertiv uses are compliant with abuse survival testing, demonstrating that cells and modules are rugged. The modules are further compliant with fire propagation requirements – in the event a failure does produce a fire, it doesn’t spread. Beyond these, the rack level assemblies Vertiv sources comply with UL requirements to contain a fire within the rack.This three-tiered approach to battery safety suggests Vertiv’s lithium-ion UPS battery racks can reasonably be considered for use in a facility with appropriate fire protection provisions and an informed emergency response team.

25 ENERGY STORAGE↗

Fire-Retardant Decorative Inks For Aircraft Interiors

Report describes testing of commercial and experimental fire retardants for incorporation into acrylic printing inks used on aircraft-interior sandwich panels. Films of acrylic ink containing fire-retardant additives prepared by casting on glass plates. Solvent evaporated in vacuum, cast films cured at 80 to 100 degree C for 30 minutes in air-circulating oven. Thermochemical properties of films examined by thermogravimetric analysis and differential scanning calorimetry (DSC). Samples of inks cast on sheets of polyvinylfloride (PVF), and their limiting oxygen indices and smoke evolution measured.

Kourtides, D. A.↗

Wildfire Emissions and Their Interaction with Urban and Rural Pollution: Data and Simulations

In recent years NASA has conducted a series of airborne campaigns (e. g. SEAC4RS*, ARCTAS, INTEX-A/B) over North America using an instrumented DC-8 aircraft equipped to measure a very large number of gaseous and aerosol constituents including several unique tracers. In these campaigns wild fires were extensively sampled near source as well as downwind after aging. The data provided detailed information on the composition and chemistry of fire emissions under a variety of atmospheric conditions as well as their interactions with rural and urban air pollution. Major fires studied including the California Rim fire in 2013 (SEAC4RS), the 2008 California wildfires (ARCTAS), and the Alaskan fires downwind over eastern US (INTEX-A). Although some fire plumes contained virtually no O3 enhancement, others showed significant ozone formation. Over Los Angeles, the highest O3 mixing ratios were observed in fire influenced urban air masses. Attempts to simulate these interactions using state of the art models were only minimally successful and indicated several shortcomings in simulating fire emission influences on urban smog formation. A variety of secondary oxidation products (e. g. O3, PAN, HCHO) were substantially underestimated. We will discuss the data collected in fire influenced air masses and their potential air quality implications.

FIre Emissions↗

Pool Fire Analysis Methodology for Assessing Damage to Waste Containers

This document provides guidelines, whereby the physical parameters associated with postulated flammable/combustible liquid pool fires are determined (thermal analysis) in order to estimate the number of waste containers impacted. Pool fire damage to waste containers may occur due to a container being fully engulfed (within the periphery of the pool), partially engulfed, or within the critical heat flux distance. The methodology described here for estimating the size of the pool fire is developed using spill characteristics outlined in Chapter 65 of the SFPE Handbook (Ref. 7) and testing done by Hansen (Ref. 25). For exposures, the critical flux height is determined using the detailed method of Shokri and Beyler (Ref. 8) from the flame height, calculated as described by Heskestad (Ref. 7) and the average black body emissive power, determined using the method of Shokri and Beyler (Ref. 8). Three types of liquid pool fires should be considered; unconfined crash/instantaneous spill fires, unconfined continuously flowing (also called metered leak) spill fires, and confined spill fires. All fuel sources should be considered consistent with the facility Fire Hazard Analysis (FHA). However, the most likely liquid fuel sources present in TRU waste facilities are those present on TRU waste handling vehicles (forklifts, pallet movers, transport trucks, etc.). This method can also be used for assessing damage to items other than waste containers or other methods of analysis may be used with appropriate justification.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

White-tailed deer responses to acoustic predator cues are contingent upon past land use and contemporary fire regime

Prey can assess the immediate risk of predation by detecting cues of predator presence, and it is expected that prey should invest in costly antipredator behaviors when a cue of predator presence is detected. Features of the habitat in which the cue is detected, such as vegetative concealment, serve as indirect cues of risk and can mediate how prey respond to direct cues of predator presence. Past agricultural land use and contemporary fire regimes are common disturbances that may modify prey perceptions of risk and could, therefore, alter prey responses to direct cues of predator presence. Here we examined whether the overlap of these two disturbances affected white-tailed deer (Odocoileus virginianus) responses to cues of predator presence by measuring deer vigilance and foraging bout duration in response to coyote (Canis latrans) vocalizations across 20 woodlands that varied in past land use and contemporary fire regime. Frequent fire regimes consistently increased deer visibility to predators across both land-use history contexts. Deer exhibited no behavioral response to the predator cue in habitats containing infrequent fire regimes or agricultural legacies. Deer responded to the cue in frequently burned woodlands without agricultural legacies through increased vigilance and time spent at a foraging location. These findings reveal that land-use legacies and contemporary fire regimes can mediate how prey respond to direct cues of risk. They also suggest that prey may balance the uncertainty associated with cues of predation risk with the urgency of responding to a potential attack by being vigilant and remaining in place.

60 APPLIED LIFE SCIENCES↗

Light, Compact Pumper for Harbor Fires

Report describes development of new transportable water-pumping unit for fire-fighting. Compact, self-contained unit provides fire protection at coastal and inland ports and is lighter than standard firetruck pumper of same capacity. Used to fight fires in harbors, cities, forests, refineries, chemical plants, and offshore drilling platforms. Other possible applications include cleaning up oilspills, pumping out ships, and flood control pumping.

Burns, R. A.↗

Fire detector response in aircraft applications

Photoelectric, ionization, and gas sensors were used to detect the signatures from the radiant heat or flame of various aircraft materials. It was found that both ionization and photoelectric detectors are about equally capable of detecting products of pyrolysis and combustion of synthetic polymers, especially those containing fire-retardant additives. Ionization detectors alone appeared to be sensitive to combustion products of simple cellulosic materials. A gas sensor detector appeared to be insensitive to pyrolysis or combustion products of many of the materials.

Wiersma, S. J.↗

Boiling Transitions During Droplet Contact on Superheated Nano/Micro-Structured Surfaces

Manipulating surface topography is one of the most promising strategies for increasing the efficiency of numerous industrial processes involving droplet contact with superheated surfaces. In such scenarios, the droplets may immediately boil upon contact, splash and boil, or could levitate on their own vapor in the Leidenfrost state. In this work we report the outcomes of water droplets coming in gentle contact with designed nano/micro-textured surfaces at a wide range of temperatures as observed using high-speed optical and X-ray imaging. Further, we report a paradoxical increase in the Leidenfrost temperature ($T_{\text{LFP}}$) as the texture spacing is reduced below a critical value (~10 μm) that represents a minima in $T_{\text{LFP}}$. Although droplets on such textured solids appear to boil upon contact, our studies suggest that their behavior is dominated by hydrodynamic instabilities implying that the increase in $T_{\text{LFP}}$ may not necessarily lead to enhanced heat transfer. On such surfaces, the droplets display a new regime characterized by splashing accompanied by a vapor jet penetrating through the droplets before they transition to the Leidenfrost state. We provide a comprehensive map of boiling behavior of droplets over a wide range of texture spacings that may have significant implications towards applications such as electronics cooling, spray cooling, nuclear reactor safety and containment of fire calamities.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Advanced Conductor Testing – 1431 kcmil Prysmian ACSS with E3X

Advanced conductors represent a significant evolution in transmission line technology. These conductors utilize innovative materials, such as composite cores, ultra-high-strength steel, and heat-dissipating coatings, to offer improved performance compared to traditional Aluminum Conductor Steel Reinforced (ACSR) designs. However, the deployment of these technologies has so far been limited. As each conductor comes with nuances in test setup and specifications, a standard test is not readily available to apply to all advanced conductors. Idaho National Laboratory’s (INL) Advanced Conductor Testing project, sponsored by the Department of Energy (DOE) Office of Cybersecurity, Energy Security, and Emergency Response (CESER) and Office of Electricity (OE), focuses on developing and implementing testing protocols and plans for advanced conductor technologies to assess and demonstrate physical performance under varying operational conditions, including extreme environmental stressors such as wildfires. This report contains the fire testing results of a 1431 kcmil Prysmian ACSS with E3X conductor.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

High-voltage spark carbon-fiber sticky-tape data analyzer

An efficient method for detecting carbon fibers collected on a stick tape monitor was developed. The fibers were released from a simulated crash fire situation containing carbon fiber composite material. The method utilized the ability of the fiber to initiate a spark across a set of alternately biased high voltage electrodes to electronically count the number of fiber fragments collected on the tape. It was found that the spark, which contains high energy and is of very short duration, is capable of partially damaging or consuming the fiber fragments. It also creates a mechanical disturbance which ejects the fiber from the grid. Both characteristics were helpful in establishing a single discharge pulse for each fiber segment.

Yang, L. C.↗

The EOS CERES Global Cloud Mask

To detect long-term climate trends, it is essential to produce long-term and consistent data sets from a variety of different satellite platforms. With current global cloud climatology data sets, such as the International Satellite Cloud Climatology Experiment (ISCCP) or CLAVR (Clouds from Advanced Very High Resolution Radiometer), one of the first processing steps is to determine whether an imager pixel is obstructed between the satellite and the surface, i.e., determine a cloud 'mask.' A cloud mask is essential to studies monitoring changes over ocean, land, or snow-covered surfaces. As part of the Earth Observing System (EOS) program, a series of platforms will be flown beginning in 1997 with the Tropical Rainfall Measurement Mission (TRMM) and subsequently the EOS-AM and EOS-PM platforms in following years. The cloud imager on TRMM is the Visible/Infrared Sensor (VIRS), while the Moderate Resolution Imaging Spectroradiometer (MODIS) is the imager on the EOS platforms. To be useful for long term studies, a cloud masking algorithm should produce consistent results between existing (AVHRR) data, and future VIRS and MODIS data. The present work outlines both existing and proposed approaches to detecting cloud using multispectral narrowband radiance data. Clouds generally are characterized by higher albedos and lower temperatures than the underlying surface. However, there are numerous conditions when this characterization is inappropriate, most notably over snow and ice of the cloud types, cirrus, stratocumulus and cumulus are the most difficult to detect. Other problems arise when analyzing data from sun-glint areas over oceans or lakes over deserts or over regions containing numerous fires and smoke. The cloud mask effort builds upon operational experience of several groups that will now be discussed.

Berendes, T. A.↗

Cyrano "Nose" The Smell of Success

Cyrano Sciences, Inc. has commercialized a simple, accurate, non- invasive tool that enables "machines to smell". The Cyranose 320 is used for quality control purposes in the food and chemical industries. Using a sensor array and onboard pattern recognition algorithms, the lightweight, portable device works by exposing an array of polymer composite sensors to the chemical components in a vapor. When the sensors come in contact with the vapor, the polymer expands like a sponge, changing the resistance of the composites. The change in resistance is measured, and from that measurement, the presence of a pre-trained substance is determined with a quick and accurate diagnosis. This real-time, portable device enables food companies to spot test raw materials for batch-to-batch consistency, spoilage, or contamination. The Cyranose 320 is also used by chemical and petrochemical companies for quick assessment of the chemical status associated with various industrial processes. Profiling a chemical environment in a hazardous materials situation allows emergency crews to accurately select fire retardants, containment strategies, and protective gear. Future applications for the Cyranose 320 are fast growing and other uses of this technology are on the horizon.

Source record↗

RECOVER: An Automated Cloud-Based Decision Support System for Post-fire Rehabilitation Planning

RECOVER is a site-specific decision support system that automatically brings together in a single analysis environment the information necessary for post-fire rehabilitation decision-making. After a major wildfire, law requires that the federal land management agencies certify a comprehensive plan for public safety, burned area stabilization, resource protection, and site recovery. These burned area emergency response (BAER) plans are a crucial part of our national response to wildfire disasters and depend heavily on data acquired from a variety of sources. Final plans are due within 21 days of control of a major wildfire and become the guiding document for managing the activities and budgets for all subsequent remediation efforts. There are few instances in the federal government where plans of such wide-ranging scope and importance are assembled on such short notice and translated into action more quickly. RECOVER has been designed in close collaboration with our agency partners and directly addresses their high-priority decision-making requirements. In response to a fire detection event, RECOVER uses the rapid resource allocation capabilities of cloud computing to automatically collect Earth observational data, derived decision products, and historic biophysical data so that when the fire is contained, BAER teams will have a complete and ready-to-use RECOVER dataset and GIS analysis environment customized for the target wildfire. Initial studies suggest that RECOVER can transform this information-intensive process by reducing from days to a matter of minutes the time required to assemble and deliver crucial wildfire-related data.

cloud computing↗

Flammable Gas Generation and Control at the Idaho Completion Project Legacy Combustible Gas Generation - 20191

On April 11, 2018, four drums containing transuranic waste at the Idaho National Laboratory underwent over-pressurization, ejecting their lids and spreading radiological waste within a facility. An investigation has found that waste in the drums generated methane gas, which contributed to the event. Subsequent to the investigation, the potential for drums to have methane and other flammable analytes whose concentrations could approach or exceed the lower flammability limit (LFL) and the adequacy of the controls to prevent or mitigate a possible deflagration was evaluated. An extensive review of the historical records was performed to determine how many drums exceed the LFL. The historical record identified a small quantity of drums that exceeded the LFL for xylene, hydrogen, and methane. The primary codified applicable code or standard for handling drums is 29 CFR 1910.120 (j) 'Handling Drums and Containers.' It is used throughout the commercial and government sector. This code is integrated throughout the Fluor Idaho safety management programs and procedures to control the Standard Industrial Hazards (SIHs) associated with drum and container handling. Example requirements include: - Drums and containers are inspected, and their integrity assured prior to being moved. - Site operations are organized to minimize the amount of drum or container movement. - When there is a reasonable possibility of flammable atmospheres being present, material handling equipment and hand tools are of the type to prevent sources of ignition. Drums and containers under pressure, as evidenced by bulging or swelling, are not moved until the cause for excess pressure is determined and appropriate containment procedures have been implemented to protect employees from explosive relief of the drum. Drums which exceed the WIPP FGA limit have NCRs associated with them. Once a drum fails flammable gas sampling, an NCR is initiated. The NCR drives placement into NCR dense pack rows. A standing order drives placement of the FGA failures to a single planer segregation location. These drums are not allowed for further processing or shipment until the NCR has been cleared. Once in the single planer rows, follow-up FGA testing is performed by CCP. The NCR is dispositioned by follow-up sampling occurring after adequate time has been provided for the gas to diffuse through the filter assembly, or, in some cases, the drums are repackaged into additional drums to reduce the source term. To date, the ICP project has performed approximately 1.5 million drums moves without a deflagration event due to combustible gas generation. Flammable gas generation in a transuranic waste drum is not unique to the ICP but is common across the DOE complex. Based on the experience at Idaho, application of industry standards is sufficient to control the risk of drum deflagration due to drum movements. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Fire-Retardant Epoxy Adhesives

Phosphorus-containing epoxy is fire-retardant and translucent. Intended as adhesive for laminated plastic sheets, new material bonds well to titanium dioxide-filled plastic film, which ordinarily shows little surface interaction with adhesives. Fire retardancy has been demonstrated, and smoke density is low enough to avoid smoke obscuration.

Bilow, N.↗