Current-Based Fault Detection and Identification for Wind Turbine Drivetrain Gearboxes
Not provided.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not provided.
This study presents an ensemble learning approach for fault classification and location identification in a smart distribution network containing photovoltaics (PV)-based microgrid. Lack of available data points and the unbalanced nature of the distribution system make fault handling a challenging task for utilities. The proposed method uses event-driven voltage data from smart meters to classify and locate faults. The ensemble voting classifier is composed of three base learners; random forest, k-nearest neighbours, and artificial neural network. The fault location (FL) task has been formulated as a classification problem where the fault type is classified in the first step and based on the fault type, the faulty bus is identified. The method is tested on IEEE-123 bus system modified with added PV-based microgrid along with dynamic loading conditions and varying fault resistances from 0 to 20 Ω for both unbalanced and balanced fault types. A further sensitivity analysis has been done to test the robustness of the proposed method under various noise levels and data loss errors in the smart meter measurements. The ensemble method shows improved performance and robustness compared to some previously proposed FL methods. Finally, the proposed method has been experimentally validated on a real-time simulation-based testbed using a state-of-the-art digital real-time simulator, industry standard DNP3 communication protocol and a cpu-based control centre running the FL algorithm.
In power electronics, prediction of states may be used for identification of faults, determination of aging of components, identification of bad data measurements, among others. Prediction of states in power electronics have broadly been based on: (a) physics-based models, (b) data-driven models, and (c) hybrid models. In this paper, data-driven approaches are presented for intelligent prediction of states in multi-port autonomous reconfigurable solar power plant (MARS) and compared. The data-set needed to train the data-driven models based on artificial intelligence (AI) algorithms has been identified and the trained models are evaluated under different extrapolated normal and abnormal operating conditions. The AI algorithms include nonlinear auto-regressive exogenous model (NARX), spiking neural networks (SNN), and decision tree. The models are compared and contrasted. The best model (NARX) is evaluated under different normal and abnormal operating conditions that have indicated accurate prediction.
New data collection system equipment was installed in Xcel Energy substations and data was collected from 6 substations and 20 feeders. During Phase I, ABB collected and analyzed 793 real-time events to date from 6 Xcel Energy substations and continues today. The development and integration of several applications was completed during the course of this project, including a model-based faulted segment identification algorithm, with very positive results validated with field-gathered data discussed and included in this report. For mostly underground feeders, the success rate is 90% and the overreach rate is 90%. For mostly overhead feeders, the success rate is 74% and the overreach rate is 50%. The developed method is producing very accurate results for mostly underground feeders. For mostly overhead feeders, due to the bad OMS data quality and varying fault resistance when arcing, the developed method is producing good results but with much room for improvement. One area where the algorithm can be improved is the accuracy for sub-cycle fault events. In these cases, the accuracy of the conventional signal processing methods suffers due to most of these methods being based on a one-cycle processing window. By improving the signal processing accuracy, the accuracy of the faulted segment identification algorithm will also improve significantly. ABB intends to devote research in this area in the near future to help solve this problem.
Cadmium telluride (CdTe) is a p-type semiconductor used in thin-film solar cells. To achieve high light-to-electricity conversion, annealing in the presence of CdCl{sub 2} is essential, but the underlying mechanism is still under debate. Recent evidence suggests that a reduction in the high density of stacking faults in the CdTe grains is a key process that occurs during the chemical treatment. A range of stacking faults, including intrinsic, extrinsic, and twin boundary, are computationally investigated to identify the extended defects that limit performance. The low-energy faults are found to be electrically benign, while a number of higher energy faults, consistent with atomic-resolution micrographs, are predicted to be hole traps with fluctuations in the local electrostatic potential. It is expected that stacking faults will also be important for other thin-film photovoltaic technologies.
Automatic identification of faults on seismic structural images is a challenging yet crucial task in quantitative seismic interpretation. Human picking or attribute-based fault detection methods may misidentify faults on noisy, complex seismic images. In this work, we develop a new automatic fault detection method using a nested residual U-shaped convolutional neural network. Each of the encoders and decoders in this neural network is a residual U-Net, leading to a nested architecture. The final fault map results from the fusion of three fault maps with low, medium, and high fault resolutions. We demonstrate the excellent fault-detection capability of our nested neural network using a series of synthetic and field seismic images. We find that our approach produces clearer and more interpretable fault maps than the current state-of-the-art U-Net fault detection method, particularly on noisy seismic images. Our new automatic fault detection method can facilitate reliable quantitative seismic interpretation on field seismic images.
This paper presents a convolutional neural network (CNN) developed to identify voltage events in photovoltaic (PV) inverters. The CNN is trained on synthetic data generated using the IEEE 13-bus distribution feeder model and evaluated on field measured data collected from Energy Northwest’s Horn Rapids Solar, Storage, and Training (HRSST) facility. The study focuses on two common voltage events: faults and voltage sags. The CNN is configured to analyze voltage and current waveforms from three-phase PV systems, demonstrating excellent accuracy during training. Field data from the HRSST facility is employed to assess its real-world performance, where the CNN achieves perfect identification of faults and voltage sags in a sample of nine events. This work highlights the potential of the proposed method to enhance PV protection schemes, providing a robust foundation for improved voltage event detection and grid reliability.
For HPC systems to date, application resilience to faults and failures has been accomplished by the brute- force method of checkpoint/restart, which allows an application to make forward progress in the face of system and application faults, errors, and failures independent of root cause or end result. It has remained the primary resilience mechanism because we lack a way to identify faults and anticipate consequences early enough to take meaningful mitigating action. However, checkpoint/restart implementations put a tremendous burden on system resources and on the applications themselves and is becoming less feasible at scale. Because we have not yet operated at scales at which checkpoint/restart fails to provide forward progress, despite increasing costs, vendors have had little motivation to provide the instrumentation necessary for early identification of faults and failures. However, as we move from petascale to exascale, component mean time to failure (MTTF) will render the existing techniques ineffectual and/or too expensive. Furthermore, fault recovery mechanisms such as failover and/or error correction introduce performance inconsistency. Instrumentation allowing early indication of problems and tools to enable use of such information by systems, operating systems, and applications offer an alternative, more scalable and less costly solution. In the HMDR project, we built on our experience and expertise developed and accumulated over years of research on design, monitoring, measurement, and assessment of resilient computing systems. Analysis of field data on the current and past generations of extreme-scale systems revealed several challenges that, if not addressed in increasingly larger and more complex systems, may hinder the effectiveness of future exascale computing systems. Specifically, i) file systems and interconnects in current-generation large-scale systems already operate at the margins of resiliency, including consistent performance, and may not scale to larger deployments; ii) automated, software-based failover mechanisms are frequently inadequate and can introduce wider failures, such that failures during recovery may lead to system/application failures, including system-wide outages; and iii) silent data corruption represents a critical fault mode and will require efficient detection mechanisms if next-generation applications are to take full advantage of exascale hardware. To address the above challenges, we assembled a team of world-renowned experts in resilient extreme- scale computing from the University of Illinois (Electrical and Computer Engineering, Computer Science, and NCSA), SNL, LANL, NERSC, and Cray. Our team includes representatives from centers that house many of the largest HPC resources in the world, both today and over the coming years. The team has a unique track record of research in i) system and application failure characterization based on the analysis of field data, ii) data-driven design of fault/error detection mechanisms, and iii) experimental characterization of system/application resiliency. The team includes system owners/operators who provide continuous data collection and access and ensure installation of appropriate analysis tools.
Quick validation and detection of faults in measured air quality data is a crucial step towards achieving the objectives of air quality networks. Therefore, the objectives of this paper are threefold: (i) to develop a modeling technique that can be used to predict the normal behavior of air quality variables and help provide accurate reference for monitoring purposes; (ii) to develop fault detection method that can effectively and quickly detect any anomalies in measured air quality data. For this purpose, a new fault detection method that is based on the combination of generalized likelihood ratio test (GLRT) and exponentially weighted moving average (EWMA) will be developed. GLRT is a well-known statistical fault detection method that relies on maximizing the detection probability for a given false alarm rate. In this paper, we propose to develop GLRT-based EWMA fault detection method that will be able to detect the changes in the values of certain air quality variables; (iii) to develop fault isolation and identification method that allows defining the fault source(s) in order to properly apply appropriate corrective actions. In this paper, reconstruction approach that is based on Midpoint-Radii Principal Component Analysis (MRPCA) model will be developed to handle the types of data and models associated with air quality monitoring networks. All air quality modeling, fault detection, fault isolation and reconstruction methods developed in this paper will be validated using real air quality data (such as particulate matter, ozone, nitrogen and carbon oxides measurement).
Abstract Successful operation and optimization of water treatment systems hinge on the availability of high-quality online sensor measurements. Ideally, the available measurements should be simultaneously accurate (i.e., unbiased and precise), representative, voluminous, and timely. This remains a pain-point in current water infrastructures, forming a barrier to a wider adoption of advanced and autonomous control systems. While short-lived symptoms, such as outliers and spikes, can be detected or corrected with state-of-the-art tools for fault detection and identification, it is much more difficult to detect, diagnose, and correct the symptoms of slow faults, such as changes in offset or sensitivity due to drift. The time scale of drift is often longer than the time scales of the system dynamics of interest. Moreover, sensor drift has been shown to occur at the same time and with similar rates when sensors are exposed to the same conditions. This challenges data quality management strategies based on redundancy. In this contribution, we develop a new method, including both a hands-off sensor calibration mechanism and an information-seeking control architecture that can handle the unique challenge of simultaneous and similar drift in online sensors.
Applying current guidance and practices for common-cause failure (CCF) mitigation to digital instrumentation and control (I&C) systems has proven problematic, and the regulatory environment has been unpredictable. The potential for CCF vulnerability inhibits I&C modernization, thereby challenging the long-term sustainability of existing plants. For new plants and advanced reactor concepts, concern about CCF vulnerability in highly integrated digital I&C systems imposes a design burden that results in higher costs and increased complexity. The regulatory uncertainty in determining which mitigation strategies will be acceptable (e.g., what diversity is needed and how much is sufficient) drives designers to adopt complicated, costly solutions devised for existing plants. To address the conditions that constrain the transition to digital I&C technology by the US nuclear industry, crosscutting research is needed to resolve uncertainty, demonstrate necessary characteristics, and establish an objective basis for qualification of digital technology for nuclear power plant (NPP) I&C applications. To fulfill this research need, Oak Ridge National Laboratory is investigating mitigation of CCF vulnerability for nuclear-qualified applications. The outcome of this research is expected to contribute to a fundamentally sound, comprehensive basis to qualify digital technology for nuclear power applications. This report documents the development of a CCF taxonomy. The basis for the CCF taxonomy was generated by determining consistent terminology and establishing a classification approach. The terminology is based on definitions from standards, guides, and relevant nuclear power industry technical reports. The classification approach is derived from identified classification schemes focused on I&C systems and key characteristics, including failure modes. The CCF taxonomy provides the basis for a systematic organization of key systems aspects relevant to analyzing the potential for CCF vulnerability and the suitability of mitigation techniques. Development of an effective CCF taxonomy will help to provide a framework for establishing the objective analysis and assessment capabilities desired to facilitate rigorous identification of fault types and triggers that are the fundamental elements of CCF.
Power system protection devices have transitioned over the past few decades from mechanical to analog devices, then to solid state and finally digital. Relays and their associated critical network of equipment have significantly increased in complexity. Even internally, relays have gained significant intricacy, with relatively simple overcurrent or differential functions now being assisted by a myriad of other functions. This is necessary as the grid becomes more complex, but it brings increased difficulty in monitoring and upkeep. Misoperation caused by improper relay settings or malicious actions is a constant challenge faced by all utilities. These improper settings can be difficult to identify and may require exhaustive post-mortem analysis, typically after a major outage event has already occurred. A mechanism is needed for monitoring the behavior of protection systems to validate that they act and perform as expected. This work presents a concept for a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. As a first step in its development, an experimental dataset is generated, and a random forest model is implemented with high accuracy in distinguishing four power system scenarios.
As power system protection devices continue the widespread transition from analog to digital, they become increasingly intricate. The internal functions and communication between critical grid components must now be significantly more complex to keep up with the demands of the modern smart grid. This brings increased difficulty in maintenance and monitoring, making it harder to identify potential misoperation, power anomalies, and cyber threats. Such issues are often only pinpointed after an exhaustive and costly post-mortem analysis, when a major outage or damage has already occurred. A solution is needed for validating protection systems as they operate, independently evaluating grid state and confirming whether the protection system is behaving accordingly. As opposed to incident response, this acts as a constant verification mechanism that raises a flag when subtler issues are noticed, catching them earlier and preventing larger incidents. This work presents the implementation of such a system, expanding on the prototype developed by the authors in a previous paper. This is accomplished with a machine learning (ML) system capable of validating the performance of protection systems by classifying anomalous events and characterizing protection system responses based solely on available current and voltage measurements. Additionally, this system is contextualized within a larger, modular Master State awareness Overseer (MSO) framework, responsible for monitoring, analyzing, and managing an electric grid.
Today’s online monitoring technologies provide opportunities to perform predictive and proactive health management of assets within many different industries, in particular the defense and aerospace industries. The nuclear industry can leverage these technologies to enhance safety, productivity, and reliability of the aging fleet of existing nuclear power plants. The U.S. Department of Energy’s Light Water Reactor Sustainability Program is collaborating with the Electric Power Research Institute’s (EPRI’s) Long-Term Operations program to implement online monitoring in existing nuclear power plants. Proactive online monitoring in the nuclear industry is being explored using EPRI’s Fleet-Wide Prognostic and Health Management (FW-PHM) Suite software, a set of web-based diagnostic and prognostic tools and databases that serves as an integrated health monitoring architecture. This paper focuses on development of asset fault signatures used to assess the health status of generator step-up transformers and emergency diesel generators in nuclear power plants. Asset fault signatures describe the distinctive features based on technical examinations that can be used to detect a specific fault type. Fault signatures are developed based on the results of detailed technical research and on the knowledge and experience of technical experts. The Diagnostic Advisor of the FW-PHM Suite software matches developed fault signatures with operational data to provide early identification of critical faults and troubleshooting advice that could be used to distinguish between faults with similar symptoms. This research is important as it will support the automation of predictive online monitoring techniques in nuclear power plants to diagnose incipient faults, perform proactive maintenance, and estimate the remaining useful life of assets.
The three main mechanical faults of the active magnetic bearing (AMB) system are put forward and distinguished from the electrical faults. Their mechanism is elaborately investigated and the quantitative relationship between failures and consequent extra forces acting on the rotors is identified. The principles for fault recognition are determined on the basis of the fault mechanism and operating experience in conventional rotating machinery. Fault features extraction methods including Poincare Map and Fast Fourier Transformation and other algorithm are adopted. A practical fault diagnosis system based on the LabVIEW platform is realized. The test result demonstrates the effectiveness of the fault diagnosis system in on-line detection and identification of mechanical faults in AMB systems. (authors)
The nature of wave resources usually requires wave energy converter (WEC) components to handle peak loads (i.e., torques, forces, and powers) that are many times greater than their average loads, accelerating equipment degradation. Moreover, due to their isolated nature and harsh operating environment, WEC systems are projected to possess high operations and maintenance (O&M) cost, i.e., around 27% of their leveled cost of energy. As such, developing techniques to mitigate these costs through the application of condition monitoring and fault tolerant control will significantly impact the economic feasibility of grid connected WEC power. Toward this goal, models of faulty components are developed in the open source modeling platform, WEC-Sim, to estimate the performance and measurable states of a WEC operating with likely device and sensor failures. Two types of faulty component models are then applied to a point absorber WEC model with basic controller damping and spring forces. Resulting changes in device behavior are recorded as a benchmark, and a graph-theoretic approach is proposed for fault detection and identification utilizing multivariate time series. Simulation results demonstrate that these faults can greatly affect the WEC performance, and that the proposed method can effectively detect and classify different types of faults.
The nuclear industry uses cable circuits as an integral part of a plant's reactor protection system (RPS), instrumentation and control (I and C) and power distribution systems. The reliability of these systems is critical for continued operation of the world's aging nuclear fleet, as well as for safe shutdown of the reactor. When intermittent faults occur in cable circuits, the symptom of the problem often appears and disappears in milliseconds while the aftereffects can result in spurious alarms and automatic actuation of safety systems. Problems are compounded when component degradation causes a cable circuit to transmit inaccurate information that does not represent actual plant operating conditions. The root cause of intermittent cable circuit operation can include degradation of cable and connectors from heat, humidity, radiation, and vibration. Unlike hard faults (which are constant open or short circuits), intermittent faults are defined as a temporary change in impedance that may only last for a few milliseconds. While less disruptive than hard faults, signal spiking from intermittent faults can often lead to alarm conditions and reactor trips. A soft fault is defined as a subtle variation the electrical characteristics of the circuit that still permit the continued operation of the circuit. A soft fault may be a precursor to a hard fault due to continued degradation of the fault over time. The focus of this paper is the description of a cable testing system that can be connected to an active, low frequency circuit and continuously monitor electrical characteristics using the time domain reflectometry (TDR) technique until an intermittent impedance change occurs. This technique uses the difference in frequency response of the circuit and the TDR to isolate the TDR signature from the active circuit data . When a momentary impedance change occurs that exceeds a preconfigured limit threshold, the distance to fault data is automatically overlaid with the healthy baseline reference and stored in a database for diagnosis and repair. (authors)
We combine a previously developed strategy for Fault Detection and Identification (FDI) with a supervisory controller in closed loop. The combined method is applied to a model of a pilot-scale cooling loop of a nuclear plant, which includes Kalman filters and a model-based predictive controller as part of normal operation. The system has two valves available for flow control meaning that some redundancy is available. The FDI method is based on likelihood ratios for different fault scenarios which in turn are derived from the application of the Kalman filter. A previously introduced extension of the FDI method is used here to enable detection and identification of non-linear faults like stuck valve problems and proper accounting of the time of fault introduction. The supervisory control system is designed so to take different kinds of actions depending on the status of the fault diagnosis task and on the type of identified fault once diagnosis is complete. Some faults, like sensor bias and drift, are parametric in nature and can be adjusted without need for reconfiguration of the regulatory control system. Other faults, like a stuck valve problem, require reconfiguration of the regulatory control system. The whole strategy is demonstrated for several scenarios.