Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Faraday cup”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Puncture discharges in surface dielectrics as contaminant sources in spacecraft environments

Spacecraft in geosynchronous orbits are known to become charged to large negative potentials during the local midnight region of the satellite orbit. Such discharges have been studied by the electron beam irradiation of dielectric samples in a vacuum environment. In addition to static measurements and photographic examination of the puncture discharges in Teflon samples, the transient characteristics of the electrical discharges are determined from oscillographs of voltage and current and by charged particle measurements employing a biased Faraday cup and a retarding potential analyzer. Using these latter techniques, studies of angular and energy distributions of charged particles have indicated an initial burst of high energy electrons (5 x 10 to the 13th power per discharge at energies greater than 300 eV) followed by a less intense burst of lower energy negative particles. Positive ions are emitted from the discharge site in an initial high velocity burst followed by a lower velocity burst tentatively identified as carbon.

Yadlowsky, E. J.↗

Gamma ray facilities at the University of Maryland cyclotron

A special beam line was set up in a separate shielded experimental room to provide a low background station for gamma-ray measurements at the University of Maryland cyclotron. The transmitted beam leaving the target is gathered in by a magnetic quadrupole lens located 1.8 m further downstream and focused on a Faraday cup located on the far side of the 2.5 m thick concrete shielding wall of the experimental room. A software computer program permits timing information ot be obtained using the cyclotron beam fine structure as a time reference for the observed gamma-ray events. Measurements indicate a beam fine structure width of less than 1.2 nanoseconds repeated, for example, in the case of 140 MeV alpha particles every 90 nanoseconds. Twelve contiguous time channels of adjustable width may be set as desired with reference to the RF signal. This allows the creation of 12 separate 8192 channel analyzers.

Hornyak, W. F.↗

Ion beam plume and efflux measurements of an 8-cm mercury ion thruster

Measurements of the ion beam plume and efflux constituents of an 8-cm mercury ion thruster have been carried out in the TRW 5 x 10 foot testing chamber. Charged components (ion beam plume) were measured with an array of movable position Faraday cups and retarding potential analyzers yielding both current density and particle energy determinations. Neutral components (ion beam efflux) were determined with a movable position ionization gauge. Measurements of the ion beam plume were performed for a thruster both with and without a sputter shield. Analysis of data in terms of normalized effluxes has been carried out and has been applied to an example calculation of efflux compatibility with a communications spacecraft.

Komatsu, G. K.↗

A simple method for obtaining a three-dimensional proton distribution function from Voyager plasma data

The main sensor of the Vogager plasma experiment consists of a cluster of three, modulated-grid Faraday cups whose normals are arranged symmetrically about the symmetry axis of the cluster at an angle of 20 degrees to that axis. In interplanetary space, each cup explores the positive ion distribution by accepting particles from contiguous slices in velocity space. The slices are narrow in the direction of the normal to the modulating grid but are broad in planes parallel to that grid. The resulting three sets of measurements can be combined to yield the three-dimensional distribution function in the following way: the distribution function is assumed to be gyrotropic. For each value of speed in a frame of reference moving with the bulk velocity of the solar wind, the variation of the distribution function with angle from the field direction is represented by a series of Legendre polynomials. Effects such as double-streaming and heat flow can be well represented by using only the first three terms of the series which are fully specified by the measurements. Examples of the use of this method in the analysis of Voyager data are shown.

Olbert, S.↗

Pulsed plasma thruster contamination studies

The exhaust plume of the one millipound pulsed plasma thruster has a measurable backflow upstream of the nozzle exit plane which may deposit on and degrade the performance of exposed spacecraft surfaces. High speed photographs and Faraday cup measurements suggest that this backflow is predominantly an electrically neutral, relatively low energy vapor. Articulated collimator quartz crystal microbalance measurements of this backflow were made for a thruster with a radically modified nozzle and a flat plate backflow shield, to determine the backflow sensitivity to nozzle design changes. The results are compared with the original nozzle backflow and show a measurable reduction in the backflow directly upstream of the shield.

Rudolph, L. K.↗

Measurements of particle emission from discharge sites in Teflon irradiated by high energy electron beams

Anomalous behavior of synchronous orbit satellites manifested by overall degradation of system performance and reduced operating life is associated with electrical discharges resulting from differential charging of the spacecraft surface by fluxes of high energy electrons. During a laboratory simulation silver-backed Teflon samples have been irradiated by electron beams having energies in the range 16-26 keV. Charged particles emitted from the resultant electrical discharges have been measured with a biased Faraday cup and retarding potential analyser. Measurements indicate the presence of two distinct fluxes of particles, the first being an early pulse (0-600ns) of high energy (about 7keV) electrons, while the second is a late pulse (1-5 microseconds) of low energy electrons (less than 1eV) and ions (70eV) leaving the discharge site as a quasi plasma. Calculations indicate an electrostatic field as the dominant accelerating mechanism for charged particles.

Hazelton, R. C.↗

Measurement of minority-carrier drift mobility in solar cells using a modulated electron beam

A determination of diffusivity on solar cells is here reported which utilizes a one dimensional treatment of diffusion under sinusoidal excitation. An intensity-modulated beam of a scanning electron microscope was used as a source of excitation. The beam was injected into the rear of the cell, and the modulated component of the induced terminal current was recovered phase sensitively. A Faraday cup to measure the modulated component of beam current was mounted next to the sample, and connected to the same electronics. A step up transformer and preamplifier were mounted on the sample holder. Beam currents on the order of 400-pA were used in order to minimize effects of high injection. The beam voltage was 34-kV, and the cell bias was kept at 0-V.

Othmer, S.↗

The dynamic expansion and contraction of the Jovian plasma sheet

Observations suggesting the sequential expansion and compression of the Jovian plasma sheet are reported. Plasma flow in the vicinity of Jupiter was monitored by the four modulated-grid Faraday cups on board each of the Voyager spacecraft at times of closest Jupiter approach. Sensor measurements reveal the flow of magnetospheric plasma to be directed away from the equatorial current sheet near local noon and to be directed towards the sheet in the dusk to midnight sector. The observed flow patterns are interpreted in terms of short-time-scale perturbations of magnetic flux tubes due to the compression of the dayside magnetosphere by the solar wind. It is noted that such a dynamic motion is quite different from what would be expected of slower, quasi-static equilibrium plasma sheet expansion and contraction.

Belcher, J. W.↗

Secondary Electron Emission Yields

The secondary electron emission (SEE) characteristics for a variety of spacecraft materials were determined under UHV conditions using a commercial double pass CMA which permits sequential Auger electron electron spectroscopic analysis of the surface. The transparent conductive coating indium tin oxide (ITO) was examined on Kapton and borosilicate glass and indium oxide on FED Teflon. The total SEE coefficient ranges from 2.5 to 2.6 on as-received surfaces and from 1.5 to 1.6 on Ar(+) sputtered surfaces with 5 nm removed. A cylindrical sample carousel provides normal incidence of the primary beam as well as a multiple Faraday cup measurement of the approximately nA beam currents. Total and true secondary yields are obtained from target current measurements with biasing of the carousel. A primary beam pulsed mode to reduce electron beam dosage and minimize charging of insulating coatings was applied to Mg/F2 coated solar cell covers. Electron beam effects on ITO were found quite important at the current densities necessary to do Auger studies.

Krainsky, I.↗

Ion thruster charge-exchange plasma flow

The electron bombardment ion thruster has been under development for a number of years and during this time, studies of the plasmas produced by the thrusters and their interactions with spacecraft have been evaluated, based on available data. Due to diagnostic techniques used and facility effects, there is uncertainty as to the reliability of data from these early studies. This paper presents data on the flow of the charge-exchange plasma produced just downstream of the thruster's ion optics. The 'end-effect' of a cylindrical Langmuir probe is used to determine ion density and directed ion velocity. Results are compared with data obtained from a retarding potential analyzer-Faraday cup.

Carruth, M. R., Jr.↗

Charged Particle Flux Sensor

Improved version of Faraday cup increases accuracy of measurements of flux density of charged particles incident along axis through collection aperture. Geometry of cone-and-sensing cup combination assures most particles are trapped.

Gregory, D. A.↗

Spectroscopic analysis of radiation-generated changes in tensile properties of a polyetherimide film

The effects of electron radiation on Ultem, a polyetherimide were studied for doses from 2 x 10 to the 9th power to 6 x 10 to the 9th power rad. Specimens were studied for tensile property testing and for electron paramagnetic resonance and infrared spectroscopic measurements of molecular structure. A Faraday cup design and a method for remote temperature measurement were developed. The spectroscopic data show that radiation caused dehydrogenation of methyl groups, rupture of main-chain ether linkage, and opening of imide rings, all to form radicals and indicate that the so-formed atomic hydrogen attached to phenyl radicals, but not to phenoxyl radicals, which would have formed hydroxyls. The observed decays of the radiation-generated phenoxyl, gem-dimethyl, and carbonyl radicals were interpreted as a combining of the radicals to form crosslinking. This crosslinking is the probable cause of the major reduction in the elongation of the tensile specimens after irradiation. Subsequent classical solubility tests indicate that the irradiation caused massive crosslinking.

Long, E. R., Jr.↗

Radionuclide measurements by accelerator mass spectrometry at Arizona

Over the past years, Tandem Accelerator Mass Spectrometry (TAMS) has become established as an important method for radionuclide analysis. In the Arizona system the accelerator is operated at a thermal voltage of 1.8MV for C-14 analysis, and 1.6 to 2MV for Be-10. Samples are inserted into a cesium sputter ion source in solid form. Negative ions sputtered from the target are accelerated to about 25kV, and the injection magnet selects ions of a particular mass. Ions of the 3+ charge state, having an energy of about 9MeV are selected by an electrostatic deflector, surviving ions pass through two magnets, where only ions of the desired mass-energy product are selected. The final detector is a combination ionization chamber to measure energy loss (and hence, Z), and a silicon surface-barrier detector which measures residual energy. After counting the trace iosotope for a fixed time, the injected ions are switched to the major isotope used for normalization. These ions are deflected into a Faraday cup after the first high-energy magnet. Repeated measurements of the isotope ratio of both sample and standards results in a measurement of the concentration of the radionuclide. Recent improvements in sample preparation for C-14 make preparation of high-beam current graphite targets directly from CO2 feasible. Except for some measurements of standards and backgrounds for Be-10 measurements to date have been on C-14. Although most results have been in archaeology and quaternary geology, studies have been expanded to include cosmogenic C-14 in meteorites. The data obtained so far tend to confirm the antiquity of Antarctic meteorites from the Allan Hills site. Data on three samples of Yamato meteorites gave terrestrial ages of between about 3 and 22 thousand years.

Jull, A. J. T.↗

Determination of cosmogenic Ca-41 in a meteorite with tandem accelerator mass spectrometry

The first use of tandem accelerator mass spectrometry (TAMS) to measure the content of Ca-41 in a natural sample, the iron Bogou meteorite, is reported. Ca in the samples was extracted by hydroxide precipitation and purified by means of a caution exchange resin (AG 50W-X8). After adding 4 percent ammonium oxide, the precipitate was ignited to CaO in a quartz vial at about 1100 C. The Ca-41/Ca ratios were determined following acceleration by alternate measurements of the Ca-40 beam current in an image Faraday cup. Ca-41 particles were also measured using a gas counter. The measured Ca-41/Ca ratio was 3.8 + or -0.6 x 10 to the 12th, which corresponds to a Ca-41 activity of 6.9 + or -1.1 d.p.m. per kg. Calculation of the half-life of Ca-41 in the Bogou meteorite yielded an age of 103,000 years.

Kubik, P. W.↗

In situ measurements of the plasma bulk velocity near the Io flux tube

Data obtained with the Voyager Plasma Science Experiment (PSE) during a flyby of the Jovian moon Io are analyzed to quantify the bulk plasma parameters near the Io flux tube. The PSE contains four modulated grid Faraday cups, three pentagonally shaped and the other circular. The path of the spacecraft around Jupiter and past Io ensured that the maximum flux was passing perpendicular to the spacecraft instruments when Voyager was closest to Io (20,000 km). A total of 11 high resolution (M mode) plasma spectra were obtained, revealing 6 species of ions: H(+), O(+), O(2+), S(+), S(2+) and S(3+). All species had the same bulk velocity and convected maxwellian distributions; the heavy ions species were all the same temperature. The mass density of the plasma near Io was 20,000-25,000 amu/cu cm and the electron density was 1300-1700/cu cm. Calculations of the Alfven speed yielded a value ranging from 250-350 km/sec and an Alfven Mach no. of 0.17-0.21. The data were equivalent to that expected from the flow of an incompressible fluid around a long cylinder with a radius about 1.25 that of Io's.

Barnett, A.↗

A high flux source of swift oxygen atoms

A source of swift oxygen atoms is described which has several unique features. A high current ion beam is produced by a microwave discharge, accelerated to 10 keV and the mass selected by a modified Du Pont 21-110 mass spectrometer. The O(+) beam exciting the mass spectrometer is focused into a rectangular shape with an energy spread of less than 1 eV. The next section of the machine decelerates the ion beam into a counterpropagating electron beam in order to minimize space charge effects. After deceleration, the ion beam intersects at 90 deg, a neutral oxygen atom beam, which via resonant charge exchange produces a mixture of O(+) and O. Any remaining O(+) are swept out of the beam by an electric field and differentially pumped away while the desired O beam, collimated by slits, impinges on the target. In situ monitoring of the target surface is done by X-ray photoelectron or Auger spectroscopy. Faraday cups provide flux measurements in the ion sections while the neutral flux is determined by a special torsion balance or by a quadrupole mass spectrometer specially adapted for swift atoms. While the vacuum from the source through the mass spectrometer is maintained by diffusion pumps, the rest of the machine is UHV.

Fink, M.↗

Pioneer and Voyager observations of the solar wind at large heliocentric distances and latitudes

Data obtained from the electrostatic analyzers aboard the Pioneer 10 and 11 spacecraft and from the Faraday cup aboard Voyager 2 were used to study spatial gradients in the distant solar wind. Prior to mid-1985, both spacecraft observed nearly identical solar wind structures. After day 150 of 1985, the velocity structure at Voyager 2 became flatter, and the Voyager 2 velocities were smaller than those observed by Pioneer 11. It is suggested that these changes in the solar wind at low latitudes may be related to a change which occurred in the coronal hole structure in early 1985.

Gazis, P. R.↗