Engineering PapersSearch

SEARCH · Engineering Papers

Results for “FREQUENCY STANDARD”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

Ionization-Assisted Getter Pumping for Ultra-Stable Trapped Ion Frequency Standards

A method eliminates (or recovers from) residual methane buildup in getter-pumped atomic frequency standard systems by applying ionizing assistance. Ultra-high stability trapped ion frequency standards for applications requiring very high reliability, and/or low power and mass (both for ground-based and space-based platforms) benefit from using sealed vacuum systems. These systems require careful material selection and system processing (cleaning and high-temperature bake-out). Even under the most careful preparation, residual hydrogen outgassing from vacuum chamber walls typically limits the base pressure. Non-evaporable getter pumps (NEGs) provide a convenient pumping option for sealed systems because of low mass and volume, and no power once activated. An ion gauge in conjunction with a NEG can be used to provide a low mass, low-power method for avoiding the deleterious effects of methane buildup in high-performance frequency standard vacuum systems.

Tjoelker, Robert L.

Ultra-stable Hg(+) trapped ion frequency standard

A fieldable trapped ion frequency standard based on Hg-199(+) ions confined in a hybrid rf/dc linear ion trap is developed. This trap permits storage of large numbers of ions with reduced susceptibility to the second-order Doppler effect caused by the rf confining fields. In preliminary measurements a stability of 2 to 3 x 10(exp -15) was obtained for 10000 second averaging times. These measurements were carried out with a 120 mHz wide atomic resonance line for the 40.5 GHz clock transition with a second order Doppler shift from the rf trapping field of 6 x 10(exp -13).

Prestage, John D.

The JPL Hg(sup +) Extended Linear Ion Trap Frequency Standard: Status, Stability, and Accuracy Prospects

Microwave frequency standards based on room temperature (sup 199)Hg(sup +) ions in a Linear Ion Trap (LITS) presently achieve a Signal to Noise and line Q inferred short frequency stability. Long term stability has been measured for averaging intervals up to 5 months with apparent sensitivity to variations in ion number/temperature limiting the flicker floor.

Hg+ linear ion trap frequency LITE LITS microwave

Measuring frequency changes due to microwave power variations as a function of C-field setting in a rubidium frequency standard

It has been shown in previous studies that in some cesium frequency standards there exist certain C-field settings that minimize frequency changes that are due to variations in the microwave power. In order to determine whether similar results could be obtained with rubidium (Rb) frequency standards (clocks), we performed a similar study, using a completely automated measurement system, on a commercial Rb standard. From our measurements we found that changing the microwave power to the filter cell resulted in significant changes in frequency, and that the magnitude of these frequency changes at low C-field levels went to zero and decreased as the C-field was increased.

E. B. Sarosy

Local oscillator induced degradation of medium-term stability in passive atomic frequency standards

As the performance of passive atomic frequency standards improves, a new limitation is encountered due to frequency fluctuations in an ancillary local oscillator (L.O.). The effect is due to time variation in the gain of the feedback which compensates L.O. frequency fluctuations. The high performance promised by new microwave and optical trapped ion standards may be severely compromised by this effect. Researchers present an analysis of this performance limitation for the case of sequentially interrogated standards. The time dependence of the sensitivity of the interrogation process to L.O. frequency fluctuations is evaluated for single-pulse and double-pulse Ramsey RF interrogation and for amplitude modulated pulses. The effect of these various time dependencies on performance of the standard is calculated for an L.O. with frequency fluctuations showing a typical 1/f spectral density. A limiting 1/sq. root gamma dependent deviation of frequency fluctuations is calculated as a function of pulse lengths, dead time, and pulse overlap. Researchers also present conceptual and hardware-oriented solutions to this problem which achieve a much more nearly constant sensitivity to L.O. fluctuations. Solutions involve use of double-pulse interrogation; alternate interrogation of multiple traps so that the dead time of one trap can be covered by operation of the other; and the use of double-pulse interrogation for two traps, so that during the time of the RF pulses, the increasing sensitivity of one trap tends to compensate for the decreasing sensitivity of the other. A solution making use of amplified-modulated pulses is also presented which shows nominally zero time variation.

Dick, G. John

Cesium and rubidium frequency standards status and performance on the GPS program

This paper is an update of the on-orbit operational performance of the frequency standards on the Block I GPS 8 to 11 Navstar satellites, the Block II GPS 13 to 21 Navstar satellites and the Block IIA GPS 22 to 40 Navstar satellites. A brief history of the frequency standards depicting improvements incorporated in the GPS Program with corresponding results will be presented. The frequency standards configurations from the start to the present, including the various Block IIA clock configurations will be discussed. Topics such as clock observations and long term trending analysis which could enhance on-orbit performance analysis will be covered.

Vanmelle, M. J.

The classical microwave frequency standards

Some key problems are presented encountered in the classical microwave frequency standards which are still not solved today. The point of view expressed benefits from the experience gained both in the industry and in the research lab, on the following classical microwave frequency standards: active and passive H, conventional and laser pumped Cs beam tube, small conventional and laser pumped Rubidium. The accent is put on the Rubidium standard.

Busca, Giovanni

Cesium and Rubidium Frequency Standards Status and Performance on the GPS Program

This paper is an update of the on-orbit operational performance of the frequency standards on the last Block 1 Navstar satellite (GPS-10), the complete Block 2 Navstar satellites (GPS-13 to 21) and the Block 2A Navstar (GPS-22 to 40) satellites. Since the status of the GPS constellation is now at full operational capability (FOC), a minimum of twenty-four satellites are in position with all the necessary tests successfully completed. The evolution of frequency standards on board the GPS vehicles will be presented with corresponding results. Various methods and techniques will be presented to show on-orbit life time, down time, state of health telemetry, on-orbit trending and characterization of all the frequency standards. Other topics such as reliability, stability, clock quirks and idiosyncrasies of each vehicle will be covered.

VanMelle, M. J.

The status of cesium beam frequency standards

There has been a lot of progress in cesium beam frequency standards in the last few years some of which will be reported here. Optical pumping is being pursued actively in a number of laboratories. Optically slowed and cooled beams have been demonstrated as well as traps for cold neutral atoms. The microwave cavity performance with regard to local phase shift at the beam holes was improved by use of carefully designed and built ring structures for the cavity ends. Work is being done on improvements in electronics with some emphasis on use of digital circuitry and microprocessors. The frequency pulling due to microwave Delta M = +/- 1 transitions (Ramsey pulling) was analyzed and shown to be important. Status of cesium beam frequency standards in some of the laboratories as well as some of the commercial work is discussed. Optical pumping and detection are discussed.

Cutler, Leonard S.

Recent developments and proposed schemes for trapped ion frequency standards

Ion traps are exciting candidates as future precision frequency sources. Recent developments demonstrate that mercury ion frequency standards are capable of a stability performance comparable to commercial cesium standards. There is, however, considerable room for improvement with regard to the signal to noise problem. The 40 GHz microwave frequency implies that a careful design should be implemented to ensure the elimination of the unwanted side bands in the microwave pump signal. A long life, high performance light source to be used in a trapped mercury ion microwave standard must be developed and the long term performance of a trapped mercury ion microwave standard must be investigated. While newly proposed two photon pumping schemes in conjuction with mercury ions promise exciting developments for both microwave and optical frequency standards, other ions that may be potential candidates should be evaluated for their usefulness.

Maleki, L.

Efficient Distribution of Frequency-Standard Signals

Low power system distributes precise frequency standard signal to network of remote stations. Reference frequency at phase angle modulates transmitter at master transmitter/receiver circuit and recovers at remote circuit. Two circuits continuously transmit on microwave or optical signals 100 MHz apart to effect synchronization of reference frequency and phase.

Meyer, R. F.

CAFS: A Cesium Atomic Frequency Standard for GPS block IIR

Kernco, Inc. was selected to design the Cesium Atomic Frequency Standards (CAFS) for the GPS Block IIR NAVSTAR satellites. These spacecraft are scheduled to be launched in the mid-1990's to replenish and upgrade the existing constellation of Global Positioning System satellites. The Block IIR CAFS output frequency is 13.4003378 MHz, the 686th submultiple of the cesium atomic resonance frequency. Using an integer submultiple simplifies the design of the atomic frequency standard's rf multiplier circuits, eliminating the secondary frequency synthesizer needed in previous designs. The GPS Block IIR CAFS design, particularly the improvements made on our earlier Block II design is described. Test results are included.

Wisnia, Jeffry A.

Operational stability of rubidium and cesium frequency standards

In the course of testing various rubidium and cesium frequency standards under operational conditions for use in NASA tracking stations, about 55 unit-years of relative frequency measurements for averaging times from 10 to 10 to the 7th power have been accumulated at Goddard Space Flight Center (GSFC). Statistics on the behavior of rubidium and cesium standards under controlled laboratory conditions have been published, but it was not known to what extent the lesser controlled environments of NASA tracking stations affected the performance of the standards. The purpose of this report is to present estimates of the frequency stability of rubidium and cesium frequency standards under operational conditions based on the data accumulated at GSFC.

Lavery, J. E.

Trapped-Mercury-Ion Frequency Standard

Report describes principle of operation, design, and results of initial measurements on trapped-mercury-ion frequency-standard apparatus at NASA's Jet Propulsion Laboratory. New frequency standard being developed. Based on linear ion trap described in (NPO-17758). Expected to show much better short-term frequency stability because of increased ion-storage capacity.

Prestage, John D.

An improved offset generator developed for Allan deviation measurement of ultra stable frequency standards

Measuring the performance of ultra stable frequency standards such as the Superconducting Cavity Maser Oscillator (SCMO) necessitates improvement of some test instrumentation. The frequency stability test equipment used at JPL includes a 1 Hz Offset Generator to generate a beat frequency between a pair of 100 MHz signals that are being compared. The noise floor of the measurement system using the current Offset Generator is adequate to characterize stability of hydrogen masers, but it is not adequate for the SCMO. A new Offset Generator with improved stability was designed and tested at JPL. With this Offset Generator and a new Zero Crossing Detector, recently developed at JPL, the measurement flow was reduced by a factor of 5.5 at 1 second tau, 3.0 at 1000 seconds, and 9.4 at 10,000 seconds, compared against the previous design. In addition to the new circuit designs of the Offset Generator and Zero Crossing Detector, tighter control of the measurement equipment environment was required to achieve this improvement. The design of this new Offset Generator are described, along with details of the environment control methods used.

R. L. Hamell

Extended linear ion trap frequency standard apparatus

A linear ion trap for frequency standard applications is provided with a plurality of trapping rods equally spaced and applied quadruple rf voltages for radial confinement of atomic ions and biased level pins at each end for axial confinement of the ions. The trapping rods are divided into two linear ion trap regions by a gap in each rod in a common radial plane to provide dc discontinuity, thus dc isolating one region from the other. A first region for ion-loading and preparation fluorescence is biased with a dc voltage to transport ions into a second region for resonance frequency comparison with a local oscillator derived frequency while the second region is held at zero voltage. The dc bias voltage of the regions is reversed for transporting the ions back into the first region for fluorescence measurement. The dual mode cycle is repeated continuously for comparison and feedback control of the local oscillator derived frequency. Only the second region requires magnetic shielding for the resonance function which is sensitive to any ambient magnetic fields.

Prestage, John D.