Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “FOULING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 55 records · Page 3

The effect of engine operating conditions on exhaust gas recirculation cooler fouling

Exhaust gas recirculation (EGR) cooler fouling occurs when particulate matter (PM) and hydrocarbons (HC) in diesel exhaust form a deposit on the walls of the EGR cooler through thermophoresis and condensation. To better understand the mechanisms controlling deposit formation and removal and how operating conditions can affect cooler performance, 20 identical tube-in-shell EGR coolers with sinusoidal fins were fouled using a 5-factor, 3-level experimental design. The deposit thickness was measured using two methods: (1) epoxy-mounting and polishing cooler cross-sections and comparing deposit thicknesses on the primary (outer tube) to the secondary (fins) heat transfer surfaces, and (2) milling tube sections such that the surface of a fin could be observed and measuring the deposit thickness across the fin using a 3D profilometer. Near the cooler inlet, high inlet gas temperatures reduced deposit thickness by promoting mud-cracking and spallation. Near the middle of the cooler, the flow rate had the largest impact on the deposit thickness through the effect on residence time of the PM. The HC concentration along with flow rate had the largest effects near the cooler outlet where the lower temperatures allows for more HC condensation. Furthermore, these insights into how engine operating conditions influence the development of fouling layers in EGR coolers learned through this study will aid in the development of more fouling resistant coolers in the future.

42 ENGINEERING↗

Multi-hydrophilic functional network enables porous membranes excellent anti-fouling performance for highly efficient water remediation

Membrane technology is believed as a cost-effective approach for solving the water issues, where as it suffers from serious membrane fouling. Surface grafting and surface coating have been proved to be effective in abating the membrane fouling; however, these processes always need additional procedures and compromise the initial permeance of the membranes. Herein, we developed a kind of highly permeable polyacrylonitrile (PAN) membranes with excellent anti-fouling performance through one-step phase inversion of the PAN casting solution containing water-soluble active additives. During the process, the water-soluble active additives could segregate towards the membrane surface and pore walls; thereby finely tailoring the pore structures of the PAN-based membranes. Moreover, the active additives could react with each other to form crosslinked networks containing multi-hydrophilic functional groups including CH2-O-CH2, -OH or-Si-OH. Consequently, the PAN-based membranes exhibited surprising superhydrophilicity with water contact angle below 10. even after soaking in water for one week and the anti-fouling permeance of the membranes increased significantly with permeance recovery rate above 93%. Interestingly, the modified membranes also demonstrated both high permeances and high separation efficiency, thereby showing strong promise in water environmental remediation including wastewater treatment and oil/water emulsion separation.

Anti-fouling↗

Use of a predictive model for the impact of cofiring coal/biomass blends on slagging and fouling propensity

The paper describes an investigation of slagging and fouling effects when cofiring coal/biomass blends by using a predictive model for large utility boilers. This model is based on the use a zone computational method to determine the midsection temperature profile throughout a boiler, coupled with a thermo-chemical model, to define and assess the risk of elevated slagging and fouling levels during cofiring of solid fuels. The application of this prediction tool was made for a 618 MW thermal wall-fired pulverized coal boiler, cofired with a typical medium volatile bituminous coal and two substitute fuels, sewage sludge and sawdust. Associated changes in boiler efficiency as well as various heat transfer and thermodynamic parameters of the system were analyzed with slagging and fouling effects for different cofiring ratios. The results of the modeling revealed that, for increased cofiring of sewage sludge, an elevated risk of slagging and high-temperature fouling occurred, in complete contrast to the effects occurring with the utilization of sawdust as a substitute fuel. 30 refs., 9 figs.,1 tab.

01 COAL, LIGNITE, AND PEAT↗

Triblock Copolymers with Grafted Fluorine-Free Amphiphilic Non-Ionic Side Chains for Antifouling and Fouling-Release Applications

Fluorine-free, amphiphilic, nonionic surface active block copolymers (SABCs) were synthesized through chemical modification of a polystyrene-block-poly(ethylene-ran-butylene)-block-polyisoprene triblock copolymer precursor with selected amphiphilic nonionic Brij and other surfactants. Amphiphilicity was imparted by a hydrophobic aliphatic group combined with a hydrophilic poly(ethylene glycol) (PEG) group-containing moiety. The surfaces were characterized by dynamic water contact angle, atomic force microscopy (AFM), X-ray photoelectron spectroscopy (XPS), and near edge X-ray absorption fine structure (NEXAFS) analysis. In biofouling assays, settlement (attachment) of both spores of the green alga Ulva and cells of the diatom Navicula on SABCs modified with Brij nonionic side chains was significantly reduced relative to a PDMS standard, with a nonionic surfactant combining a PEG group and an aliphatic moiety demonstrating the best performance. Additionally, a fouling-release assay using sporelings (young plants) of Ulva and Navicula suggested that the SABC derived from nonionic Brij side chains also out-performed PDMS as a fouling-release material. Good antifouling and fouling-release properties were not demonstrated for the other two amphiphilic surfaces derived from silicone and aromatic group containing nonionic surfactants included in this study. The results suggest that small differences in chemical surface functionality impart more significant changes with respect to the antifouling settlement and fouling-release performance of materials than overall wettability behavior.

36 MATERIALS SCIENCE↗

On the mechanism of marine fouling-prevention performance of oil-containing silicone elastomers

For many decades, silicone elastomers with oil incorporated have served as fouling-release coating for marine applications. In a comprehensive study involving a series of laboratory-based marine fouling assays and extensive global field studies of up to 2-year duration, we compare polydimethylsiloxane (PDMS) coatings of the same composition loaded with oil via two different methods. One method used a traditional, one-pot pre-cure oil addition approach (o-PDMS) and another method used a newer post-cure infusion approach (i-PDMS). The latter displays a substantial improvement in biofouling prevention performance that exceeds established commercial silicone-based fouling-release coating standards. We interpret the differences in performance between one-pot and infused PDMS by developing a mechanistic model based on the Flory–Rehner theory of swollen polymer networks. Using this model, we propose that the chemical potential of the incorporated oil is a key consideration for the design of future fouling-release coatings, as the improved performance is driven by the formation and stabilization of an anti-adhesion oil overlayer on the polymer surface.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Heat Exchanger Design Optimization for Mitigation of Diesel Engine Exhaust Fouling

Abstract The design optimization of a diesel exhaust-coupled heat and mass exchanger that drives a 2.71 kW cooling capacity absorption heat pump is presented in this study. Fouling layer thermal resistance and pressure drops from single-tube experiments are used to develop a thermodynamic, heat transfer, and pressure drop model for the exhaust-coupled desorber. A parametric study is performed to select a desorber design that meets system performance while minimizing footprint. Experimental heat duties and pressure drops are within 10% and 3%, respectively, of the model predictions. Thus, large data sets from single-tube experiments with representative geometries are successful in accounting for fouling effects at the component level. Desorber design optimization based on this approach ensures continued heat pump performance after fouling. This study, along with the single-tube experiments, presents a systematic approach to design exhaust-coupled heat exchangers while considering the effects of fouling. These results are applicable for a wide range of waste-heat recovery applications, and this method can be extended to different geometries and operating conditions.

Energy & Fuels↗

Fouling-Resistant Membranes for Treating Concentrated Brines for Water Reuse in Advanced Energy Systems- Final Technical Report

The high total dissolved solids (TDS) levels in the wastewater quality generated from unconventional oil and gas development make the current state-of-the art approach to water treatment/disposal untenable. Our proposed membrane technology approach addresses the two major challenges associated with this water: 1) the membrane distillation process removes the high TDS content, which is often 8 times higher than that of seawater, and 2) our novel membrane coating prevents the formation of scale that would otherwise pose a significant operational hurdle. This is accomplished through next-generation electrically conductive membranes that mitigate fouling beyond what is currently possible, and allow for the flexibility to treat to the water to levels desirable for multiple reuse options, thus reducing fresh water withdrawal, all the way to direct disposal into the environment. The overall project objective was to demonstrate the efficacy of membrane distillation (MD) as a cost-savings technology to treat concentrated brines (such as, but not limited to, produced waters generated from fossil fuel extraction) that have high levels of TDS for beneficial water reuse in power production and other industrial operations as well as agricultural and municipal water uses. In addition, a novel fouling-resistant nanocomposite membrane was developed to reduce the need for chemicals to address membrane scaling due to the precipitation of divalent ions in high-TDS waters and improve overall MD performance via an electrically conductive membrane distillation process (ECMD). This anti-fouling membrane technology platform is based on incorporating carbon nanotubes (CNTs) into the surface layer of existing, commercially available MD membranes. The CNTs impart electrical conductivity to the membrane surface to prevent membrane scaling and fouling when an electrical potential is applied.

36 MATERIALS SCIENCE↗

Advanced Anti-Fouling Coatings to Improve the Efficiency of Coal Power Plants

As the total cost of carbon to generate energy has become a global concern, operators are increasingly looking at all parts of the generation cycle to find areas where efficiency gains may be found. It has been long identified that fouling of heat exchangers is a persistent cause of up to 2.5% of global CO 2 emissions. Unfortunately, practice has also demonstrated that unless a powerful economic driver exists to encourage preemptive mitigation of fouling, there will always be a strong tendency for operators to minimize any form of intervention due to high costs and challenges in scheduling downtime. The objective of this proposed research effort was to demonstrate how existing power plants could lower their carbon emissions and significantly improve heat transfer efficiency using new surface treatment materials to control fouling in a variety of heat exchange equipment. The surface treatment material which was optimized and deployed in this effort is now known commercially as HeatX. It is a low-surface energy, water- and oil-repellent, abrasion resistant material which can be applied in-situ to a wide variety of previously worn/used/in-service substrates. Once applied, it provides a barrier against corrosion, scale deposit formation, and biofilm adhesion on the circulating water-containing tube-side. Alternatively, if applied to the tube exterior, the non-wetting nature of the surface was demonstrated to promote dropwise condensation, subsequently lowering condenser backpressure and increasing overall plant efficiency. As part of this cooperative effort, the Department of Energy’s support was crucial to de-risk and demonstrate the concept of HeatX, while validating both the performance and economic benefit in multiple pilot field studies. The HeatX material properties were optimized in this effort for full field applicability to heat exchangers and condensers, and Oceanit developed the necessary procedures and protocols to provide enough material to support extended length, multi-year demonstrations in the power generation, desalination, and refining industries, making this technology broadly applicable and ready for commercial transition. Field deployment case studies at thermal power plants have shown that the HeatX treatment can provide economic savings of up to $15,000 per day for an operator based on avoiding maintenance costs and lowering fuel usage. The complete mitigation of fouling effects can increase the efficiency of equipment by up to 7%, in a field where gains of 0.5% are generally seen as operationally significant. The HeatX treatment has also demonstrated exceptional lifetime and compatibility with a wide variety of seawater and hydrocarbon environments, further increasing both the return on investment and the effective emission reduction. Such efficiency improvements correlate to massive carbon savings. For every 1 GW of capacity, operators can see carbon emissions reductions of 300,000 tons of CO 2 per year. When looking at the bigger picture, improved condenser function across the U.S. has the potential to prevent 221.3 million tons of CO 2 emissions, equivalent to the sequestration capacity of 129 million acres of forest. If applied on a global scale, 1.26 billion metric tons of CO 2 could be averted from the atmosphere, the same amount of carbon sequestrated by 1.5 billion acres of forest annually or 262,000 wind turbines operating annually. As businesses across multiple industries take a more active role in focusing on environmental, social, and governance (ESG) solutions as part of their core business operations, HeatX will be an attractive technology for commercial investment.

01 COAL, LIGNITE, AND PEAT↗

Biological material fouling assessment systems and methods

Biological material fouling assessment systems and methods are described. According to one aspect, a biological material fouling assessment system includes processing circuitry configured to access image data of an image of a surface of a substrate which has been fouled with biological material, wherein the image data comprises intensity information regarding a plurality of pixels of the image, and wherein the processing circuitry is further configured to process the intensity information regarding the pixels of the image to generate information which is indicative of an amount of the fouling of the biological material upon the surface of the substrate.

42 ENGINEERING↗

Complete coverage fouling model for constant flux crossflow ultrafiltration and experimental validation

A complete coverage model is proposed to describe fouling in constant flux crossflow ultrafiltration. Constant flux crossflow fouling experiments were conducted using dilute latex bead suspensions and commercial poly(ether sulfone) flat sheet ultrafiltration membranes to investigate the influence of operating conditions on evolution of transmembrane pressure (ΔP, TMP) with time. Changes in permeate flux or crossflow rate had little influence on the normalized TMP profile at high latex bead concentration (i.e., above 25 ppm) because the membrane surface was covered with latex beads. At low concentration (i.e., below 25 ppm), increases in permeate flux or foulant concentration increased normalized ΔP. However, this increase in normalized ΔP with permeate flux or foulant concentration diminishes when the permeate flux/concentration is high enough to overwhelm particle removal due to crossflow. Furthermore, these results are in good agreement with the new complete coverage model which describes the influence of operating parameters on fouling better than the previous model.

36 MATERIALS SCIENCE↗

Emulsion separation and fouling of electrospun polyacrylonitrile membranes for produced water applications

Produced water (PW) is a complex mixture generated during oil and gas extraction. Membrane fouling by hydrocarbon emulsions (sizes < 10 µm) challenges most PW treatment systems. Electrospinning has the possibility of creating microporous membranes that present unique performance properties, though evaluations of these characteristics are largely restricted to unrealistic dead-end configurations. Three different nanofibrous polyacrylonitrile (PAN) membranes were synthesized by electrospinning and their performances contrasted with a commercially available PAN membrane. Feed solutions included synthetic oil and solvent emulsions and a PW from an operating well-site. Two nanoparticles, polyaniline (PANI) and reduced graphene oxide (RGO), were studied for enhancing the oleophobicity and fouling properties of the electrospun PAN membranes. Electrospun membranes showed higher porosities (68 to 80 %) and water permeance values (9,000 to 10,000 LMH/bar) relative to that for the commercially available PAN membrane (44 % and 8,800 LMH/bar). All electrospun membranes provided superior performance characteristics when treating the emulsions and PW relative to the commercial membrane. Furthermore, the PANI integrated membrane demonstrated the greatest resistance to oil/solvent emulsion fouling and comparable performance to the RGO and PAN membrane treating the PW.

03 NATURAL GAS↗

Direct Measurement of EGR Cooler Deposit Thermal Properties for Improved Understanding of Cooler Fouling

Exhaust gas recirculation (EGR) cooler fouling has become a significant issue for compliance with NOx emissions standards. This paper reports results of a study of fundamental aspects of EGR cooler fouling. An apparatus and procedure were developed to allow surrogate EGR cooler tubes to be exposed to diesel engine exhaust under controlled conditions. The resulting fouled tubes were removed and analyzed. Volatile and non-volatile deposit mass was measured for each tube. Thermal diffusivity of the deposited soot cake was measured by milling a window into the tube and using the Xenon flash lamp method. The heat capacity of the deposit was measured at temperatures up to 430°C and was slightly higher than graphite, presumably due to the presence of hydrocarbons. These measurements were combined to allow calculation of the deposit thermal conductivity, which was determined to be 0.041 W/mK, only ~1.5 times that of air and much lower than the 304 stainless steel tube (14.7 W/mK). The main determinant of the deposit thermal conductivity is density, which was measured to be just 2% that of the density of the primary soot particles (or 98% porous). The deposit layer thermal resistance was calculated and compared with estimates of the thermal resistance calculated from gas temperature data during the experiment. The deposit properties were also used to further analyze the temperature data collected during the experiment.

33 ADVANCED PROPULSION SYSTEMS↗

Numerical Modeling and Experimental Investigations of EGR Cooler Fouling in a Diesel Engine

EGR coolers are mainly used on diesel engines to reduce intake charge temperature and thus reduce emissions of NOx and PM. Soot and hydrocarbon deposition in the EGR cooler reduces heat transfer efficiency of the cooler and increases emissions and pressure drop across the cooler. They may also be acidic and corrosive. Fouling has been always treated as an approximate factor in heat exchanger designs and it has not been modeled in detail. The aim of this paper is to look into fouling formation in an EGR cooler of a diesel engine. A 1-D model is developed to predict and calculate EGR cooler fouling amount and distribution across a concentric tube heat exchanger with a constant wall temperature. The model is compared to an experiment that is designed for correlation of the model. Effectiveness, mass deposition, and pressure drop are the parameters that have been compared. The results of the model are in a good agreement with the experimental data.

33 ADVANCED PROPULSION SYSTEMS↗

Effect of makeup water properties on the condenser fouling in power planr cooling system

The thermoelectric power industry in the U.S. uses a large amount of fresh water. As available freshwater for use in thermoelectric power production becomes increasingly limited, use of nontraditional water sources is of growing interest. Utilization of nontraditional water, in cooling systems increases the potential for mineral precipitation on heat exchanger surfaces. In that regard, predicting the accelerated rate of scaling and fouling in condenser is crucial to evaluate the condenser performance. To achieve this goal, water chemistry should be incorporated in cooling system modeling and simulation. This paper addresses the effects of various makeup water properties on the cooling system, namely pH and aqueous speciation, both of which are important factors affecting the fouling rate in the main condenser. Detailed modeling of the volatile species desorption (i.e. CO{sub 2} and NH{sub 3}), the formation of scale in the recirculating system, and the relationship between water quality and the corresponding fouling rates is presented.

97 MATHEMATICS AND COMPUTING↗

Investigations of ash fouling with cattle wastes as reburn fuel in a small-scale boiler burner under transient conditions

Fouling behavior under reburn conditions was investigated with cattle wastes (termed as feedlot biomass, FB) and coal as reburn fuels under a transient condition and short-time operation. A small-scale (30 kW or 100,000 Btu/hr) boiler burner research facility was used for the reburn experiments. The fuels considered for these experiments were natural gas (NG) for the ashless case, pure coal, pure FB, and blends of coal and FB. Two parameters that were used to characterize the ash 'fouling' were (1) the overall heat-transfer coefficient (OHTC) when burning NG and solid fuels as reburn fuels, and (2) the combustible loss through ash deposited on the surfaces of heat exchanger tubes and the bottom ash in the ash port. A new methodology is presented for determining ash fouling behavior under transient conditions. Results on the OHTCs for solid reburn fuels are compared with the OHTCs for NG. It was found that the growth of the layer of ash depositions over longer periods typically lowers OHTC, and the increased concentration of ash in gas phase promotes radiation in high-temperature zones during initial periods while decreasing the heat transfer in low-temperature zones. The ash analyses indicated that the bottom ash in the ash port contained a smaller percentage of combustibles with a higher FB percentage in the fuels, indicating better performance compared with coal because small particles in FB burn faster and the FB has higher volatile matter on a dry ash-free basis promoting more burn out. 16 refs., 12 figs., 6 tabs.

01 COAL, LIGNITE, AND PEAT↗

Application of electrodialysis pretreatment to enhance boron removal and reduce fouling during desalination by nanofiltration/reverse osmosis

we report membranes have emerged as promising technologies for treatment of non-traditional waters, but fouling and poor rejection of small, neutral solutes (e.g., boric acid) impede their further implementation for water purification. Boron rejection is increased by raising the pH to convert boric acid to borate ion, but this change often leads to calcite supersaturation. This study investigated the use of a hybrid electrodialysis-nanofiltration/reverse osmosis (ED-NF/RO) system to reduce fouling from calcite precipitation and calcium-polysaccharide sorption to NF/RO membranes. Also, the study examined the potential of the hybrid process to increase permeate flux and boron rejection during NF/RO of synthetic saline water. ED pretreatment reduced calcite oversaturation and reduced flux decline during NF/RO. Low alginate concentrations (25 mg/L) limited NF/RO fouling, but high concentrations (100 mg/L) appeared to promote calcite scaling. ED pretreatment reduced the osmotic pressure of the NF/RO feed water, enabling lower operating pressures or greater permeate water fluxes. Boron rejection during NF/RO increased with ED pretreatment, probably due to stronger electrostatic repulsion and an increase in the fraction of total boron present as B(OH)4- following ED. This hybrid ED-NF/RO system shows promise as a novel approach to enhancing the performance of current membrane systems for treating complex feed waters.

alginate↗

Molecular fouling resistance of zwitterionic and amphiphilic initiated chemically vapor-deposited (iCVD) thin films

Biofouling is a universal problem in various applications ranging from water purification to implantable biomedical devices. Recent advances in surface modification have created a rich library of antifouling surface chemistries, many of which can be categorized into one of the two groups: hydrophilic surfaces or amphiphilic surfaces. We report the straightforward preparation of antifouling thin film coatings in both categories via initiated chemical vapor deposition. A molecular force spectroscopy-based method is demonstrated as a rapid and quantitative assessment tool for comparing the differences in antifouling characteristics. The fouling propensity of single molecules, as opposed to bulk protein solution or bacterial culture, is assessed. This method allows for the interrogation of molecular interaction without the complication resulted from protein conformational change or micro-organism group interactions. The molecular interaction follows the same trend as bacterial adhesion results obtained previously, demonstrating that molecular force probe is a valid method for the quantification and mechanistic examination of fouling. In addition, the molecular force spectroscopy-based method is able to distinguish differences in antifouling capability that is not resolvable by traditional static protein adsorption tests. To lend further insight into the intrinsic fouling resistance of zwitterionic and amphiphilic surface chemistries, Fourier transform infrared spectroscopy, X-ray photoelectron spectroscopy, advancing and receding water contact angles, and atomic force microscopy are used to elucidate the film properties that are relevant to their antifouling capabilities.

Yang, R↗

Jupyter notebooks for analyzing transmission SAXS/WAXS from beamline 7.3.3 during operando membrane fouling experiments v1.0

This software consists of python-based Jupyter Notebooks for processing transmission x-ray scattering images collected at beamline 7.3.3 at the Advanced Light Source. The measurements considered in these analyses are collected during membrane fouling experiments, where contaminants in the water deposit on/attach to the membrane surface. This software is used to elucidate the mechanisms of membrane fouling that occur during these operando membrane fouling experiments, but the analyses provided in these scripts can be extended to other scientific cases.

Landsman, Matthew [Lawrence Berkeley National Labo↗