Simulations of a Circulating Fluidized Bed Chemical Looping Combustion System Utilizing Gaseous Fuel
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Previous work has shown that acoustic spectra of fluidized bed pressure fluctuations show many useful bed properties [1-3]. This current work further explores the use of acoustic monitors for an 18' diameter, 66-74'' height fluidized bed at >640 deg. C. This process denitrates and agglomerates an injected sodium/aluminum nitrate aqueous simulant and produces at steady-state a denitrated product of 200-300 micron sodium carbonate/aluminate particles. The fluidized bed shows characteristic acoustic resonances around 1-2 Hz in the FFT (Fast Fourier Transform) of pressure fluctuations for each of three taps at fluidized bed heights of 12'', 39'', and 58''. The acoustic resonance spectra depend on a bed friction that once calibrated, monitors the HMPD (harmonic mass mean particle diameter or Sauter mean diameter) along with other important bed properties. This fluidized bed operates at high temperature with an evolving HMPD that can be steady state with an appropriate superficial spatial velocity (SSV). The acoustic FFT integrated power spectrum, IPS, of pressure fluctuations represents the bed-friction damped RMS (root mean square) pressure fluctuations at each tap. The transition from a static to fluidized bed at each bed height occurs when the damped bed RMS pressure fluctuations are greater than the static head (the FFT zero Hz designated zero Hz proportional to FFT zero Hz) at that bed height. A bed will de-fluidize and become static at a bed height when bed friction completely dampens the RMS pressure fluctuations, which occurs for decreasing particle size among other factors. The ratio IPS/zero Hz then provides a continuous monitor of bed friction damping as well as particle size as the HMPD. Since HMPD and bed friction damping are both very important parameters for fluidized particle beds, the acoustic HMPD and bed friction damping both provide very useful monitors for fluidized bed operation. Such acoustic monitors have shown that they are especially sensitive to the presence of very fine particles in the bed of less than 50 microns diameter. Acoustic monitors for particle size and bed friction damping will be very useful in any fluidized bed, especially fluidized beds where particle size changes. The fluidized bed friction damping depends on many other bed properties besides particle size such as bed height, density, SSV, void fraction, gas viscosity, and fluidization scheme and so acoustic bed friction should also be useful for monitoring other bed properties besides particle size. In fact, the change in the static bed friction slope with SSV upon fluidization follows the Ergun function and reveals a minimum fluidization velocity for each HMPD. (authors)
High-temperature thermal energy storage in oxide particles at temperatures above 600°C can couple concentrated solar energy with high-efficiency thermal power cycles to provide dispatchable solar-driven electricity. Challenges remain in developing cost-effective primary heat exchangers, which require expensive alloys, to extract the high-temperature thermal energy from the particles to power cycle fluids, such as supercritical CO 2 (sCO 2 ) in recuperated Brayton cycles. To explore one pathway for cost-effective, high-temperature particle heat exchangers, the current study demonstrates a shell-and-plate, particle–sCO 2 heat exchanger with narrow- channel fluidized beds coupled with micro-channel sCO 2 flows in the heat exchanger walls. This study evaluates the feasibility of multiple parallel, narrow-channel fluidized beds in shell-and-plate particle–sCO 2 HXs, to achieve high bed-wall heat fluxes at elevated temperatures. A reduced-order model simulates the narrow- channel, fluidized-bed particle–sCO 2 heat exchanger to design the fluidized bed geometry, in terms of depth, height, and number of channels,for a nominal 40-kWth heat exchanger at particle and sCO 2 inlet temperatures up to 600 °C and 400 °C respectively. The resulting shell-and-plate heat exchanger design operates with bubbling fluidization of the downward-flowing oxide particles to enhance bed-wall heat transfer. The heat exchanger core is fabricated with etched sCO 2 micro-channels in thin wall plates that are diffusion bonded to spacer frames to form the shell-and-plate structure with 12 parallel, fluidized bed channels, 10.4 mm deep. The heat exchanger is tested at the National Solar Thermal Test Facility at Sandia National Laboratories with CARBOBEAD HSP particles at design particle flow rates of 0.20 kg s –1 and inlet temperatures up to 525 °C. Results show that fluidization across multiple parallel channel beds can maintain uniform particle inventory with a common freeboard zone above the heat exchanger core. Bubbling fluidization improves particle–wall heat transfer coefficients but also increases axial dispersion of particle thermal energy, which lowers the log- mean temperature difference such that total heat transfer remains relatively constant to within ±10% over a broad range of fluidization gas velocities. The axial dispersion required particle and sCO 2 flow rates to be increased by 25% over model-designed conditions to achieve the targeted 40 kWth, which indicates the importance of incorporating axial dispersion into heat exchanger design models and of deploying bed structures to suppress it. Furthermore, this study demonstrates the feasibility and preferred fluidizing gas conditions for particle heat exchangers for releasing high-temperature thermal energy storage systems.
The Integrated Waste Treatment Unit (IWTU) has been tasked with using steam reforming technology to treat 3.4 million liters of radioactive sodium-bearing waste (SBW) at the INL. Progress in developing steam reforming for SBW treatment has been hampered by numerous processing issues associated with the existing process equipment during simulant testing. The primary issue was high differential temperatures that developed in the fluidized bed of the denitration mineralization reformer (DMR). Based on technical evaluations and computer modeling, it was determined that the primary cause of poor fluidization in the DMR was the existing fluidized gas distributor. This distributor consisted of a combination of a ring header and four removable fluidizing gas rails. The combined ring header/rail system was unable to effectively fluidize the bed at the bottom of the DMR (around and below the ring header). As a result, a decision was made to design and test a new fluidized gas distributor. Conceptual designs focused on three different distributors: a modified design of the current system; a flat plate with bubble caps; and a conical bottom with dual plena. After testing the conceptual prototypes at Hazen Research Inc., the conical bottom distributor was chosen. A 30-day test with simulant SBW feed was then performed with the new distributor. During testing, a temperature differential of less than 2 deg. C was maintained in the DMR fluidized bed. The results supported the conclusion that poor fluidized gas distribution was the primary cause of high temperature differentials in the DMR fluidized bed. (authors)
One of the largest challenges for 21st century is to fulfill global energy demand while also reducing detrimental impacts of energy generation and use on the environment. Gasification is a promising technology to meet the requirement of reduced emissions without compromising performance. Coal gasification is not an incinerating process; rather than burning coal completely a partial combustion takes place in the presence of steam and limited amounts of oxygen. In this controlled environment, a chemical reaction takes place to produce a mixture of clean synthetic gas. Gas-solid fluidized bed is one such type of gasification technology. During gasification, the mixing behavior of solid (coal) and gas and their flow patterns can be very complicated to understand. Many attempts have taken place in laboratory scale to understand bed hydrodynamics with spherical particles though in actual applications with coal, the particles are non-spherical. This issue drove the documented attempt presented here to investigate fluidized bed behavior using different ranges of non-spherical particles, as well as spherical. For this investigation, various parameters are controlled that included particle size, bed height, bed diameter and particle shape. Particles ranged from 355 µm to 1180 µm, bed diameter varied from 2 cm to 7 cm, two fluidized beds with diameters of 3.4 cm and 12.4 cm, for the spherical and non-spherical shaped particles that were taken into consideration. Pressure drop was measured with increasing superficial gas velocity. The velocity required in order to start to fluidize the particle is called the minimum fluidization velocity, which is one of the most important parameters to design and optimize within a gas-solid fluidized bed. This minimum fluidization velocity was monitored during investigation while observing variables factors and their effect on this velocity. From our investigation, it has been found that minimum fluidization velocity is independent of bed height for both spherical and non-spherical particles. Further, it decrease with decreasing particle size and decreases with decreasing bed diameter. Shadow sizing, a non-intrusive imaging and diagnostic technology, was also used to visualize flow fields inside fluidized beds for both spherical and non- spherical particles and to detect the particle sizes.
Robust metal oxide particles can provide low-cost and stable thermal energy storage (TES) to temperatures up to 1200 °C or higher. The transfer of heat into and out of the particles in cost-effective high-temperature particle heat exchangers remains a principal challenge to implementing particle-based TES. The present work expands on prior studies of particle-wall heat transfer in narrow-channel fluidized beds operated in the bubbling fluidization regime. Batch-mode experiments with various oxide particles over a range of temperatures and airflow rates indicate that particle-wall heat transfer increases with higher bed temperature and decreasing particle size. Measured particle-wall heat transfer coefficients in a 12 mm deep channel are fit to a Nusselt number correlation proportional to a non-monotonic function of excess fluidization velocity. Particle-wall heat transfer coefficients rise rapidly with excess fluidization velocities until reaching a maximum at intermediate air velocities due to a trade-off between enhanced transverse particle mixing and decreasing particle volume fraction with increased fluidization velocity. The heat transfer coefficient reaches a maximum of ≈ 400% of values without fluidization for oxide particles ranging in diameter d p from 159 to 408 μm. For the smallest particles tested, composed of olivine sand, particle-wall heat transfer coefficients peak above 1100 Wm –2 K –1 at 450 °C. 100-h tests at 500 °C and near-optimal heat transfer fluidization velocities indicated minimal wall wear or oxide scaling. Furthermore, high particle-wall heat transfer coefficients suggest narrow channel fluidized beds as a potential pathway for reducing the required surface area and cost of high-temperature particle heat exchangers, as needed in large-scale thermal energy storage applications.
Coarse-grid two-fluid simulation of gas-solid fluidized bed reactors based on the kinetic theory of granular flow exhibits a significant dependence on drag models, especially for Geldart A particles. Many drag models are available in the literature, which have been reported to work for different systems. This work focused on the evaluation of an enhanced filtered drag model along with other different drag models derived from different methods for three-dimensional two-fluid model simulations of gas-solid fluidized beds of Geldart A particles covering a broad range of fluidization regimes, including bubbling fluidization, turbulent fluidization, fast fluidization, and dilute phase transport regimes. Eight drag models were selected, which included five heterogeneous drag models and three homogeneous drag models. Comparison with the available experimental data demonstrates the need for modification of homogeneous drag models to account for the effect of mesoscale structures (i.e., bubbles and clusters). The enhanced filtered drag model and energy-minimization multi-scale (EMMS) drag models were found to achieve superior predictions in all fluidization regimes, while the other drag models were only capable of predicting certain fluidization regimes. Finally, the results of this work provide a guideline for choosing appropriate drag models for simulating Geldart A particles and suggestions on developing more reliable and general drag models applicable in all flow regimes.
Here, the spout-bed fluidization behavior of nonspherical, 140 μm SiC feedstock was quantified via particle image velocimetry for varying gas distributor geometries. A bench-scale, room-temperature fluidization setup was assembled to model a 50 mm fluidized bed chemical vapor deposition (FB-CVD) system, and fluidized bed motion was captured using a high-speed camera. Modular tips with varying inlet geometries were 3D printed and tested on the bench-scale rig using identical feedstock and gas flow rates in the range of 3.0–9.0 L/min. Fluidization behavior was quantified by extracting parameters of the bed velocity, frequency, dead time, and other measurements, which were ranked for each inlet geometry configuration tested. The results from this work demonstrate that changing the path of inlet gas flow can significantly change the hydrodynamics within a spout-fluidized bed under identical feedstock, loading, and flow rate conditions, potentially enabling experimental control of particle fluidization behavior for a given condition. Moreover, composite rankings of fluidization behavior for unique distributor geometries hold potential to guide the design of FB-CVD experiments for various engineering and scientific applications.
Colorado School of Mines (Mines) led this program in collaboration with Sandia National Laboratories (Sandia) to characterize narrow-channel fluidized beds of aluminosilicate particles – supplied by Carbo Ceramics – as a means for releasing high-temperature thermal energy in particle heat exchangers and for capturing concentrated solar energy in indirect particle receivers. Single-channel, heat transfer experiments at Mines and reduced-order 1-D models and 3-D two-fluid, CFD models explored many aspects of counterflow, bubbling fluidized beds (net downward particle flow and upward gas flow) for enhancing particle-wall heat transfer at elevated temperatures. Results at Mines on single-channel test sections consistently showed that mild bubbling fluidization increases particle-wall heat transfer coefficients (h T,w ) regularly by more than 4.0x over h T,w values without fluidization at similar conditions (mean particle diameter d p , bed depth Δz b , and bed particle temperatures T p ). Insights from lab-scale tests and modeling studies provided Nusselt number correlations for h T,w and informed the design and fabrication (by Vacuum Process Engineering) of a nominal 40-kWth, particle-sCO 2 plate heat exchanger (HX) with 12 parallel narrow-channel, fluidized beds bounded by stainless-steel walls with embedded microchannels for high-pressure sCO 2 flows. Tests of the 40-kW th HX at the particle-sCO 2 HX test stand at Sandia's National Solar Thermal Test Facility (NSTTF) were limited, due to HX design, to particle inlet temperatures T p,in ≤ 520°C with maximum sCO 2 outlet temperatures T sCO2,out ≈ 440°C, which are well below design conditions for a primary HX in a sCO 2 power cycle for a Gen-3 concentrating solar power (CSP) plant. Total heat transfer $\dot{Q}_{HX}$ remains relatively constant with increased fluidization for fixed particle and sCO 2 inlet conditions because higher h T,w due to fluidization is offset by increased axial dispersion, which suppresses temperature differences between the particles and sCO 2 in the counterflow configuration. The axial dispersion reduces the effective overall heat transfer coefficient U based on T p,in to values around 200 W m -2 K -1 .
This study evaluated the influence of diameter and grain size on the initiation and continuation phase of piping erosion. Twelve tests were performed in a laboratory setting in which sand was fluidized in a controlled setting and hydraulic gradients within the sand, flow rates through the sand, and expansion of the sand columns were measured as the sand was fluidized. This study was conducted to improve the understanding of the resistance a vertical column of sand offers to piping erosion. From the fluidization tests conducted in two permeameters with different diameters, it cannot be concluded that permeameter diameter has a significant influence on a specimen’s resistance to piping erosion. Although one test conducted in the smaller diameter permeameter did record hydraulic gradients lower than those recorded in tests conducted in the larger diameter permeameter, this was not a consistent observation for all tests run in the smaller diameter permeameter. Further analysis ought to involve more tests run in each permeameter as well as incorporating additional permeameters with both larger and smaller diameters than those used in this study. From the fluidization tests conducted using the well-graded, coarse-, medium-, and fine-grained sands, it appears that resistance to piping is dependent on grain size and grain size distribution. The coarse-grained sand offered the most resistance to piping, the fine-grained sand offered the least, and the medium-grained and well-graded sands offered similar resistances between those of the coarse-grained and fine-grained sands. Gradients at which sand boils were observed, maximum gradients reached before the sand fluidized, and the minimum gradients reached at the conclusion of each test also appear to be influenced by grain size and grain size distribution. Tests conducted on the coarse-grained sand recorded the highest and most closely spaced sand boil, maximum, and minimum gradients, indicating that it offered the highest and most constant resistance to piping, while the fine-grained sand tests recorded the lowest sand boil, maximum, and minimum gradients, indicating that it offered the least resistance to piping and that resistance decreased as the tests progressed. The medium-grained sand tests recorded sand boil, maximum, and minimum gradients between those of the coarse-grained and fine-grained sands. The well-graded sand tests recorded the lowest sand boil gradient, which could be indicative of the occurrence of suffusion erosion occurring in conjunction with piping erosion, whereby the finer particles were washed out of the sand matrix at relatively low gradients, forming sand boils while the relatively coarser matrix remained resistant to piping. All tests recorded maximum gradients that were lower than the theoretical critical gradients calculated using Equation 4. This is likely due to the changes in the internal configuration of the sand as the piping process 33 initiates. In order to better understand the influence of gradation on resistance to piping, more sand gradations should be tested in future work. Measured hydraulic gradients in the lower portion of the fluidized sands were higher than those measured in higher portions. This could be explained if the density of the fluidized sand was not uniform, with more material near the base of the column than near the top, which is contrary to the findings of Sellmeijer. Furthermore, the tests were terminated when the maximum height of the upstream reservoir was reached but did not give any evidence that gradients had leveled off to a uniform “final gradient”. It is likely that gradients would have continued to dissipate had more hydraulic head been applied to the upstream reservoir. In order to better understand this, additional testing should be conducted using an upstream reservoir capable of simulating higher hydraulic heads.
Fast pyrolysis of biomass in a fluidized bed reactor is typically conducted in a nitrogen gas environment. Recycling product gas can improve the economics of operating such a system by reducing reliance on pure process streams, but much less is known about how recycling pyrolysis product gas may affect fluidization behavior and pyrolysis kinetics. Therefore, gas effects in a fluidized bed biomass pyrolysis reactor were investigated using engineering correlations, low-order models, and CFD simulations for N 2 , H 2 , CO, CO 2 , and CH 4 carrier gas mixtures. Here, our findings reveal viscosity of a gas mixture can be significantly underestimated depending on the model and correlation. Furthermore, fluidization characteristics such as U mf and gas-solid convective heat transfer can be greatly affected by the gas properties. By utilizing H 2 as the fluidizing gas (instead of N 2 ), while maintaining a constant fluidization ratio (U s /U mf ), the bio-oil yields can be increased ~5%. This is due to the lower density H 2 producing similar hydrodynamics as N 2 at higher gas flow rates. These higher flow rates result in shorter gas residence times, and as a result, less secondary reactions that convert bio-oil to light gases and char. Model results also suggest that bio-oil yield is not significantly affected by the type of carrier gas used, with bio-oil yield varying by ~2% across different gas mixtures while maintaining constant flow rate. In conclusion, this indicates that recycled pyrolytic gas can be used as the carrier gas for biomass pyrolysis.
A fluidized bed coupled rotary reactor has been designed for coating on nanoparticles (NPs) via atomic layer deposition. It consists of five major parts: reaction chamber, dosing and fluidizing section, pumping section, rotary manipulator components, as well as a double-layer cartridge for the storage of particles. In the deposition procedure, continuous fluidization of particles enlarges and homogenizes the void fraction in the particle bed, while rotation enhances the gas-solid interactions to stabilize fluidization. The particle cartridge presented here enables both the fluidization and rotation acting on the particle bed, demonstrated by the analysis of pressure drop. Moreover, enlarged interstitials and intense gas–solid contact under sufficient fluidizing velocity and proper rotation speed facilitate the precursor delivery throughout the particle bed and consequently provide a fast coating process. The cartridge can ensure precursors flowing through the particle bed exclusively to achieve high utilization without static exposure operation. By optimizing superficial gas velocities and rotation speeds, minimum pulse time for complete coating has been shortened in experiment, and in situ mass spectrometry showed the precursor usage can reach 90%. Inductively coupled plasma-optical emission spectroscopy results suggested a saturated growth of nanoscale Al{sub 2}O{sub 3} films on spherical SiO{sub 2} NPs. Finally, the uniformity and composition of the shells were characterized by high angle annular dark field-transmission electron microscopy and energy dispersive X-ray spectroscopy.
Polyethylene is one of the most widely used plastics, and over 60 million tons are produced worldwide every year. Polyethylene is obtained by the catalytic polymerization of ethylene in gas and liquid phase reactors. The gas phase processes are more advantageous, and use fluidized-bed reactors for production of polyethylene. Since they operate so close to the melting point of the polymer, agglomeration is an operational concern in all slurry and gas polymerization processes. Electrostatics and hot spot formation are the main factors that contribute to agglomeration in gas-phase processes. Electrostatic charges in gas phase polymerization fluidized bed reactors are known to influence the bed hydrodynamics, particle elutriation, bubble size, bubble shape etc. Accumulation of electrostatic charges in the fluidized-bed can lead to operational issues. In this work a first-principles electrostatic model is developed and coupled with a multi-fluid computational fluid dynamic (CFD) model to understand the effect of electrostatics on the dynamics of a fluidized-bed. The multi-fluid CFD model for gas-particle flow is based on the kinetic theory of granular flows closures. The electrostatic model is developed based on a fixed, size-dependent charge for each type of particle (catalyst, polymer, polymer fines) phase. The combined CFD model is first verified using simple test cases, validated with experiments and applied to a pilot-scale polymerization fluidized-bed reactor. The CFD model reproduced qualitative trends in particle segregation and entrainment due to electrostatic charges observed in experiments. For the scale up of fluidized bed reactor, filtered models are developed and implemented on pilot scale reactor.
The design of fuel feed ports in a large-scale fluidized bed combustor depends on the fuel characteristics and lateral solids mixing. However, the reported values of the effective lateral solids dispersion coefficient (D{sub sr}) are scattered in the broad range of 0.0001-0.1 m{sup 2}/s. With the aim of predicting D{sub sr} in wider fluidized beds which is difficult to measure directly or deduce from experimental results in lab-scale facilities, a computational method is proposed. It combines the Eulerian-Granular simulation and fictitious particle tracing technique. The value of D{sub sr} is calculated based on the movement of the tracers. The effect on D{sub sr} of bed width (W) ranging from 0.4 m up to 12.8 m at different levels of superficial gas velocity (U{sub 0}) is investigated. It is found that increasing W whilst maintaining U{sub 0}, D{sub sr} initially increases markedly, then its increase rate declines, and finally it stays around a constant value. The computed values of D{sub sr} are examined quantitatively and compared with a thorough list of the measured D{sub sr} in the literature since 1980s. Agreed with the measurements performed in the pilot-scale fluidized beds, the value of D{sub sr} in wider facilities at higher fluidizing velocities is predicted to be around the order of magnitude of 0.1 m{sup 2}/s, much higher than that in lab-scale beds. Finally, the effect of D{sub sr} on the distribution of fuel particles over the cross section in fluidized beds with the specified layout of feed ports is discussed. (author)
The design of spout-fluidized bed (SFB) coating systems for nuclear particle fuels typically relies on trial-and-error processes, comprising iterative and time-consuming coating deposition experiments and post-deposition characterization. At an engineering scale, this approach to guided SFB system design is inefficient, highlighting the need for streamlined experimental methodologies which can correlate fluidization conditions to downstream coating outcomes. In this study, we combine time-resolved particle image velocimetry (PIV) with CFD–DEM simulations to benchmark hydrodynamic behavior in a 3D spout-fluidized bed. By exploiting easily accessible optical measurements of particle motion at the bed wall and within the spouting region, we obtain quantitative velocity fields that can be directly compared with model predictions of the occluded bed region, without resorting to complex imaging and characterization techniques such as X-ray or magnetic resonance tomography. Experimental benchmarking reveals strong agreement between CFD–DEM and PIV in the spout and annulus regions, while discrepancies near the wall highlight areas for future model development. Here, the proposed integrated experimental–numerical framework will enable a direct connection between measured variables and numerically predicted fluidization performance of dense, surrogate nuclear particle fuel feedstock such that experimental SFB component design can be rapidly evaluated, informing design decisions for nozzle geometry and operating conditions. Future work will extend this framework by correlating quantified fluidization metrics across nozzle geometries and operating conditions with the resulting coating morphology, microstructure, and uniformity. Establishing these correlations will enable predictive links between hydrodynamic performance and coating quality, providing a rational, scalable basis for optimizing SFB design prior to coating deposition.
Abstract: Experiments of CO{sub 2} capture and sorbent regeneration characteristics of limestone, dolomite, and CaO/Ca{sub 1}2Al{sub 14}O{sub 3}3 at high temperature were investigated in a thermogravimetric analyzer (TGA) and a fluidized bed reactor. The effect of reactivity decay of limestone, dolomite, and CaO/Ca{sub 12}Al{sub 14}O{sub 3}3 sorbents on CO{sub 2} capture and sorbent regeneration processes was studied. The experimental results indicated that the operation time of high efficient CO{sub 2} capture stage declined continuously with increasing of the cyclic number due to the loss of the sorbent activity, and the final CO{sub 2} capture efficiency would remain nearly constant, due to the sorbent already reaching the final residual capture capacity. After the CO{sub 2} capture step, the Ca-based sorbents need to be regenerated to be used for a subsequent cycle, and the multiple calcination processes of Ca-based sorbent under different calcination conditions are studied and discussed. Reactivity loss of limestone, dolomite and CaO/Ca{sub 12}Al{sub 14}O{sub 3}3 sorbents from a fluidized bed reactor at both mild and severe calcination conditions was compared with the TGA data. At mild calcination conditions, TGA results of sorbent reactivity loss were similar to the experimental results of fluidized bed reactor for three sorbents at 850 degrees C calcination temperature, and this indicated that TGA experimental results can be used as a reference to predict sorbent reactivity loss behavior in fluidized bed reactor. At severe calcination condition, sorbent reactivity loss behavior for limestone and dolomite from TGA compare well with the result from a fluidized bed reactor.
Particle fluidized beds have the potential to improve the efficiency of heat transfer in concentrated solar receiver furnace for use in next generation concentrated solar power (CSP) plants. This study presents an experimental investigation on the flow characterization of vertically downward moving packed bed with counter fluidization through an array of jets. To control the bubble size and its distribution in the bubbling fluidized bed, an array of cylindrical pin fins was arranged uniformly across the test article. The flow visualization was performed on the surface of transparent glass coated with electrically conductive materials for electrostatic dissipation purposes. The image acquisition was carried out via high-speed camera at a frequency of ~ 1kHz. The acquired images were analyzed in pairs with the help of a modern optical flow algorithm capable of calculating the movement of dense particle flow in the fluidized bed by tracking the light intensity of each predefined window of the frames. A comparison of fluidized beds with plane and pin-finned channels revealed distinct bubble behavior. Pin-finned channels were found to produce a larger number of small-sized bubbles, while plane channels generated fewer but larger bubbles at any given instant. The presence of pin fins was observed to reduce bubble size by preventing bubble merging and splitting larger bubbles when they encountered a pin.
Experiments were conducted to investigate pattern formation during the defluidization of a partially fluidized bimodal granular mixture. Partial fluidization occurs when the system is driven at gas velocities that are insufficient to fluidize all of the constituent particles. Over time, the granular mixture evolves into a variety of patterns depending on the concentrations of large and small particles and the gas velocity. We show how vertically oriented pipes, containing large particles, grow at the interface between the fluidized and static zones. The heterogeneities in the permeability field focus the flow, causing localized fluidization, which in turn localizes the sedimentation of the large particles segregating the system. We discuss how the interplay between heterogeneities in material properties, fluid flow and fluid induced deformation may be relevant to a variety of geological processes.